999 resultados para SPE-HLLME-GS-MS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution mass spectrometry (HRMS) has been associated with qualitative and research analysis and QQQ-MS with quantitative and routine analysis. This view is now challenged and for this reason, we have evaluated the quantitative LC-MS performance of a new high-resolution mass spectrometer (HRMS), a Q-orbitrap-MS, and compared the results obtained with a recent triple-quadrupole MS (QQQ-MS). High-resolution full-scan (HR-FS) and MS/MS acquisitions have been tested with real plasma extracts or pure standards. Limits of detection, dynamic range, mass accuracy and false positive or false negative detections have been determined or investigated with protease inhibitors, tyrosine kinase inhibitors, steroids and metanephrines. Our quantitative results show that today's available HRMS are reliable and sensitive quantitative instruments and comparable to QQQ-MS quantitative performance. Taking into account their versatility, user-friendliness and robustness, we believe that HRMS should be seen more and more as key instruments in quantitative LC-MS analyses. In this scenario, most targeted LC-HRMS analyses should be performed by HR-FS recording virtually "all" ions. In addition to absolute quantifications, HR-FS will allow the relative quantifications of hundreds of metabolites in plasma revealing individual's metabolome and exposome. This phenotyping of known metabolites should promote HRMS in clinical environment. A few other LC-HRMS analyses should be performed in single-ion-monitoring or MS/MS mode when increased sensitivity and/or detection selectivity will be necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest treball pretén analitzar l’oferta cultural al municipi de Palafrugell i la seva projecció turística, per tal de formular propostes de millora i contribuir així a augmentar la presència turística en aquest tipus de recursos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hexafluoroacetylaceton derivatives of some synthesized components of the guazatine fungicide were prepared, and their separation and identification performed through gas chromatography and gas chromatography-mass spectrometry. The chromatogram obtained from hexafluoroacetylacetone derivative of the commercial guazatine presented 14 major peaks, and 9 of them were identified through both techniques mentioned above.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquesta és la primera guia d'identificació de la col∙lecció i es dedica als Efemeròpters (INSECTA: EPHEMEROPTERA). Els gèneres i grups d’espècies inclosos a la guia són aquells que de forma més freqüent hem trobat ens els estudis que realitzem en el marc del programa “Estudis de la Qualitat Ecològica dels Rius de la Província de Barcelona”. Aquest programa fou una iniciativa promoguda per la Diputació de Barcelona mitjançant la seva Oficina Tècnica d'Acció Territorial de l'Àrea de Territori i Sostenibilitat. La major part de les fotografies corresponen exemplars recol∙lectats el 2012 a les parts altes del riu Llobregat i els seus afluents pels membres del nostre grup de recerca, tot i que en alguns casos s’han examinat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquesta és la segona guia d'identificació de la col•lecció i es dedica als Plecòpters (INSECTA: PLECOPTERA). Els gèneres i grups d’espècies inclosos a la guia són aquells que de forma més freqüent hem trobat ens els estudis que realitzem en el marc del programa “Estudis de la Qualitat Ecològica dels Rius de la Província de Barcelona”. Aquest programa fou una iniciativa promoguda per la Diputació de Barcelona mitjançant la seva Oficina Tècnica d'Acció Territorial de l'Àrea de Territori i Sostenibilitat. La major part de les fotografies corresponen exemplars recol•lectats el 2013 a les parts altes del riu Llobregat i els seus afluents pels membres del nostre grup de recerca, tot i que en alguns casos s’han examinat les mostres històriques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquesta és la primera guia d'identificació de la col∙lecció i es dedica als Efemeròpters (INSECTA: EPHEMEROPTERA). Els gèneres i grups d’espècies inclosos a la guia són aquells que de forma més freqüent hem trobat ens els estudis que realitzem en el marc del programa “Estudis de la Qualitat Ecològica dels Rius de la Província de Barcelona”. Aquest programa fou una iniciativa promoguda per la Diputació de Barcelona mitjançant la seva Oficina Tècnica d'Acció Territorial de l'Àrea de Territori i Sostenibilitat. La major part de les fotografies corresponen exemplars recol∙lectats el 2012 a les parts altes del riu Llobregat i els seus afluents pels membres del nostre grup de recerca, tot i que en alguns casos s’han examinat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquesta és la segona guia d'identificació de la col•lecció i es dedica als Plecòpters (INSECTA: PLECOPTERA). Els gèneres i grups d’espècies inclosos a la guia són aquells que de forma més freqüent hem trobat ens els estudis que realitzem en el marc del programa “Estudis de la Qualitat Ecològica dels Rius de la Província de Barcelona”. Aquest programa fou una iniciativa promoguda per la Diputació de Barcelona mitjançant la seva Oficina Tècnica d'Acció Territorial de l'Àrea de Territori i Sostenibilitat. La major part de les fotografies corresponen exemplars recol•lectats el 2013 a les parts altes del riu Llobregat i els seus afluents pels membres del nostre grup de recerca, tot i que en alguns casos s’han examinat les mostres històriques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A piezoelectric detector based on a commercial quartz crystal of 3.57MHz is shown. A PTFE cell attached to the GC-column outlet holds the polymer-coated crystal, whose terminals were removed. Two TTL oscillators (reference and sensor) are used and the beating of their frequencies is monitored through a home-made counter card inserted in a microcomputer. The original thermal conductivity detector was also interfaced, but through a 12-bit analog-to-digital converter. In spite of the well-known fact that QCM has low sensitivity at high temperatures, results show significant peak deformation for low temperatures. In addition, the phenomenon is also dependent on the chemical composition of the absorbent film besides instantaneous partial pressure and chemical composition of the analyte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[spa] En el presente artículo se presentan los tres grandes ámbitos en los que se desarrolla la investigación arqueométrica sobre cerámicas: la identificación de los materiales, la proveniencia de los artefactos y la tecnología en la que se inscriben. El artículo hace una incidencia especial en aquello que se entiende por tecnología, indicando que la tecnología de producción es únicamente una parte de la misma, y que el concepto básico es el de diseño, que debe adecuarse a una multiplicidad de características de desempeño, explicadas por la cadena conductual en la cual transcurre la vida de los artefactos. Dado que las culturas se expresan por medio de artefactos, la vertiente material de éstos refleja, aunque sólo sea en parte, los compromisos que dichos artefactos tienen en las culturas en estudio. La arqueometría, con un cuerpo teórico y metodológico adaptado a la investigación de esta vertiente natural de los artefactos, aparece así como una forma complementaria de hacer arqueología y no como un campo de estudio diferenciado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo pretende ser una herramienta que aporte información relativa a los usos de diez de los primeros verbos más frecuentes del español comparados con los usos que se encuentran en amazigh y que pueda servir como complemento en la prevención de posibles errores durante el proceso de aprendizaje del español por parte de estudiantes hablantes de amazigh

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE) and solid phase microextraction (SPME). The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD). Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The word gas was coined by the "chemical philosopher" Joan Baptista Van Helmont (1579 -- 1644) to name a very broad concept in his chemico-medical system. Eventually, some physicians who followed Helmontian ideas adopted the concept. The present paper aims to analyze the reception of the original idea of gas by an English Helmontian physician, George Thomson (1619 -- 1677). Thomson wrote that the "material cause" of the plague was a gas, and compared it to the "Gas of sulphur". He also related the human archeus to a gas, and explained some observations in the laboratory in terms of production of gases. We observe, however, that Thomson was not as interested as Van Helmont in discussing details about the structure of the matter. Thus, gas did not have the same relevance in Thomson's work as it had in Van Helmont's.