950 resultados para Prostaglandin E2
Resumo:
BACKGROUND: Open angle glaucoma (OAG) is a common cause of blindness.
OBJECTIVES: To assess the effects of medication compared with initial surgery in adults with OAG.
SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2012), EMBASE (January 1980 to August 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to August 2012), Biosciences Information Service (BIOSIS) (January 1969 to August 2012), Cumulative Index to Nursing and Allied Health Literature (CINAHL) (January 1937 to August 2012), OpenGrey (System for Information on Grey Literature in Europe) (www.opengrey.eu/), Zetoc, the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 1 August 2012. The National Research Register (NRR) was last searched in 2007 after which the database was archived. We also checked the reference lists of articles and contacted researchers in the field.
SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing medications with surgery in adults with OAG.
DATA COLLECTION AND ANALYSIS: Two authors independently assessed trial quality and extracted data. We contacted study authors for missing information.
MAIN RESULTS: Four trials involving 888 participants with previously untreated OAG were included. Surgery was Scheie's procedure in one trial and trabeculectomy in three trials. In three trials, primary medication was usually pilocarpine, in one trial it was a beta-blocker.The most recent trial included participants with on average mild OAG. At five years, the risk of progressive visual field loss, based on a three unit change of a composite visual field score, was not significantly different according to initial medication or initial trabeculectomy (odds ratio (OR) 0.74, 95% confidence interval (CI) 0.54 to 1.01). In an analysis based on mean difference (MD) as a single index of visual field loss, the between treatment group difference in MD was -0.20 decibel (dB) (95% CI -1.31 to 0.91). For a subgroup with more severe glaucoma (MD -10 dB), findings from an exploratory analysis suggest that initial trabeculectomy was associated with marginally less visual field loss at five years than initial medication, (mean difference 0.74 dB (95% CI -0.00 to 1.48). Initial trabeculectomy was associated with lower average intraocular pressure (IOP) (mean difference 2.20 mmHg (95% CI 1.63 to 2.77) but more eye symptoms than medication (P = 0.0053). Beyond five years, visual acuity did not differ according to initial treatment (OR 1.48, 95% CI 0.58 to 3.81).From three trials in more severe OAG, there is some evidence that medication was associated with more progressive visual field loss and 3 to 8 mmHg less IOP lowering than surgery. In the longer-term (two trials) the risk of failure of the randomised treatment was greater with medication than trabeculectomy (OR 3.90, 95% CI 1.60 to 9.53; hazard ratio (HR) 7.27, 95% CI 2.23 to 25.71). Medications and surgery have evolved since these trials were undertaken.In three trials the risk of developing cataract was higher with trabeculectomy (OR 2.69, 95% CI 1.64 to 4.42). Evidence from one trial suggests that, beyond five years, the risk of needing cataract surgery did not differ according to initial treatment policy (OR 0.63, 95% CI 0.15 to 2.62).Methodological weaknesses were identified in all the trials.
AUTHORS' CONCLUSIONS: Primary surgery lowers IOP more than primary medication but is associated with more eye discomfort. One trial suggests that visual field restriction at five years is not significantly different whether initial treatment is medication or trabeculectomy. There is some evidence from two small trials in more severe OAG, that initial medication (pilocarpine, now rarely used as first line medication) is associated with more glaucoma progression than surgery. Beyond five years, there is no evidence of a difference in the need for cataract surgery according to initial treatment.The clinical and cost-effectiveness of contemporary medication (prostaglandin analogues, alpha2-agonists and topical carbonic anhydrase inhibitors) compared with primary surgery is not known.Further RCTs of current medical treatments compared with surgery are required, particularly for people with severe glaucoma and in black ethnic groups. Outcomes should include those reported by patients. Economic evaluations are required to inform treatment policy.
Resumo:
OBJECTIVES: To determine effective and efficient monitoring criteria for ocular hypertension [raised intraocular pressure (IOP)] through (i) identification and validation of glaucoma risk prediction models; and (ii) development of models to determine optimal surveillance pathways.
DESIGN: A discrete event simulation economic modelling evaluation. Data from systematic reviews of risk prediction models and agreement between tonometers, secondary analyses of existing datasets (to validate identified risk models and determine optimal monitoring criteria) and public preferences were used to structure and populate the economic model.
SETTING: Primary and secondary care.
PARTICIPANTS: Adults with ocular hypertension (IOP > 21 mmHg) and the public (surveillance preferences).
INTERVENTIONS: We compared five pathways: two based on National Institute for Health and Clinical Excellence (NICE) guidelines with monitoring interval and treatment depending on initial risk stratification, 'NICE intensive' (4-monthly to annual monitoring) and 'NICE conservative' (6-monthly to biennial monitoring); two pathways, differing in location (hospital and community), with monitoring biennially and treatment initiated for a ≥ 6% 5-year glaucoma risk; and a 'treat all' pathway involving treatment with a prostaglandin analogue if IOP > 21 mmHg and IOP measured annually in the community.
MAIN OUTCOME MEASURES: Glaucoma cases detected; tonometer agreement; public preferences; costs; willingness to pay and quality-adjusted life-years (QALYs).
RESULTS: The best available glaucoma risk prediction model estimated the 5-year risk based on age and ocular predictors (IOP, central corneal thickness, optic nerve damage and index of visual field status). Taking the average of two IOP readings, by tonometry, true change was detected at two years. Sizeable measurement variability was noted between tonometers. There was a general public preference for monitoring; good communication and understanding of the process predicted service value. 'Treat all' was the least costly and 'NICE intensive' the most costly pathway. Biennial monitoring reduced the number of cases of glaucoma conversion compared with a 'treat all' pathway and provided more QALYs, but the incremental cost-effectiveness ratio (ICER) was considerably more than £30,000. The 'NICE intensive' pathway also avoided glaucoma conversion, but NICE-based pathways were either dominated (more costly and less effective) by biennial hospital monitoring or had a ICERs > £30,000. Results were not sensitive to the risk threshold for initiating surveillance but were sensitive to the risk threshold for initiating treatment, NHS costs and treatment adherence.
LIMITATIONS: Optimal monitoring intervals were based on IOP data. There were insufficient data to determine the optimal frequency of measurement of the visual field or optic nerve head for identification of glaucoma. The economic modelling took a 20-year time horizon which may be insufficient to capture long-term benefits. Sensitivity analyses may not fully capture the uncertainty surrounding parameter estimates.
CONCLUSIONS: For confirmed ocular hypertension, findings suggest that there is no clear benefit from intensive monitoring. Consideration of the patient experience is important. A cohort study is recommended to provide data to refine the glaucoma risk prediction model, determine the optimum type and frequency of serial glaucoma tests and estimate costs and patient preferences for monitoring and treatment.
FUNDING: The National Institute for Health Research Health Technology Assessment Programme.
Resumo:
Objective: This study evaluated the changing trends in glaucoma management in Scotland between 1994 and 2004. Methods: A retrospective analysis of national health statistics in Scotland from 1994 to 2004. The Scottish morbidity record was used to collect information on all episodes of trabeculectomy. Data on number of prescriptions were gathered for individual drugs and also for groups of active ingredient. The population likely to have glaucoma (PLG) was calculated from estimates of prevalence in individuals aged 40 years and older, based on published epidemiological studies. The outcome measures were trabeculectomy rates, corrected for population likely to be at risk of glaucoma (PLG), and prescribing volume and cost for glaucoma medications. Results: Trabeculectomy rates have fallen by 67% from 46 per 1000 PLG in 1994 to 15.4 per 1000 PLG in 2004. Over the same time period, the population likely to be at risk of glaucoma (PLG) increased by 16.6%. The cost of prescribing has increased by 122% over 11 years compared with an increase in number of items per 1000 PLG by 27.5%. In 1994, ß-blockers accounted for 65.2% of prescribed drugs but by 2004 this had dropped to 33%. Since their introduction, the prescribing of prostaglandin analogues has increased rapidly and in 2004, they accounted for 39.4% of prescribed drugs. Conclusion: The increasing useof prostaglandin analogues has led to an increase in prescribing rates and a rapid increase in cost. At the same time, prescribing of ß-blockers has declined and trabeculectomy rates have fallen.
Resumo:
BACKGROUND: Open angle glaucoma (OAG) is the commonest cause of irreversible blindness worldwide. OBJECTIVES: To study the relative effects of medical and surgical treatment of OAG. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2005), MEDLINE (1966 to February 2005), EMBASE (1988 to February 2005), and reference lists of articles. We also contacted researchers in the field. SELECTION CRITERIA: Randomised controlled trials comparing medications to surgery in adults. DATA COLLECTION AND ANALYSIS: Two authors independently assessed trial quality and extracted data. We contacted trial investigators for missing information. MAIN RESULTS: Four trials involving 888 participants with previously untreated OAG were included. Surgery was Scheie's procedure in one trial and trabeculectomy in three trials. In three trials, primary medication was usually pilocarpine, in one trial a beta-blocker.In the most recent trial, participants with mild OAG, progressive visual field (VF) loss, after adjustment for cataract surgery, was not significantly different for medications compared to trabeculectomy (Odds ratio (OR) 0.74; 95% CI 0.54 to 1.01). Reduction of vision, with a higher risk of developing cataract (OR 2.69, 95%% CI 1.64 to 4.42), and more patient discomfort was more likely with trabeculectomy than medication.There is some evidence, from three trials, for people with moderately advanced glaucoma that medication is associated with more progressive VF loss and 6 to 8 mmHg less intraocular pressure (IOP) lowering than surgery, either by a Scheie's procedure or trabeculectomy. There was a trend towards an increased risk of failed IOP control over time for initial pilocarpine treatment compared to trabeculectomy. In the longer-term (two trials) the risk of failure was significantly greater with medication than trabeculectomy (OR 3.90, 95% CI 1.60 to 9.53; HR 7.27, 95% CI 2.23 to 25.71). Medicine and surgery have evolved since these trials were undertaken, and additionally the evidence is potentially subject to detection and attrition bias. AUTHORS' CONCLUSIONS: Evidence from one trial suggests, for mild OAG, that VF deterioration up to five-years is not significantly different whether treatment is initiated with medication or trabeculectomy. Reduced vision, cataract and eye discomfort are more likely with trabeculectomy. There is some evidence, for more severe OAG, that initial medication (pilocarpine, now rarely used as first line medication) is associated with greater VF deterioration than surgery. In general, surgery lowers IOP more than medication.There was no evidence to determine the effectiveness of contemporary medication (prostaglandin analogues, alpha2-agonists and topical carbonic anhydrase inhibitors) compared to surgery in severe OAG, and in people of black African ethnic origin who have a greater risk of more severe open angle glaucoma. More research is required.
Resumo:
Elevated intraocular pressure (IOP) is a major risk factor for the deterioration of open-angle glaucoma (OAG); medical IOP reduction is the standard treatment, yet no randomized placebo-controlled study of medical IOP reduction has been undertaken previously. The United Kingdom Glaucoma Treatment Study (UKGTS) tests the hypothesis that treatment with a topical prostaglandin analog, compared with placebo, reduces the frequency of visual field (VF) deterioration events in OAG patients by 50% over a 2-year period.
Resumo:
Objectives: This study sought to investigate the effect of a multiple micronutrient supplement on left ventricular ejection fraction (LVEF) in patients with heart failure. Background: Observational studies suggest that patients with heart failure have reduced intake and lower concentrations of a number of micronutrients. However, there have been very few intervention studies investigating the effect of micronutrient supplementation in patients with heart failure. Methods: This was a randomized, double-blind, placebo-controlled, parallel-group study involving 74 patients with chronic stable heart failure that compared multiple micronutrient supplementation taken once daily versus placebo for 12 months. The primary endpoint was LVEF assessed by cardiovascular magnetic resonance imaging or 3-dimensional echocardiography. Secondary endpoints were Minnesota Living With Heart Failure Questionnaire score, 6-min walk test distance, blood concentrations of N-terminal prohormone of brain natriuretic peptide, C-reactive protein, tumor necrosis factor alpha, interleukin-6, interleukin-10, and urinary levels of 8-iso-prostaglandin F2 alpha. Results: Blood concentrations of a number of micronutrients increased significantly in the micronutrient supplement group, indicating excellent compliance with the intervention. There was no significant difference in mean LVEF at 12 months between treatment groups after adjusting for baseline (mean difference: 1.6%, 95% confidence interval: -2.6 to 5.8, p = 0.441). There was also no significant difference in any of the secondary endpoints at 12 months between treatment groups. Conclusions: This study provides no evidence to support the routine treatment of patients with chronic stable heart failure with a multiple micronutrient supplement. (Micronutrient Supplementation in Patients With Heart Failure [MINT-HF]; NCT01005303).
Resumo:
PURPOSE: To evaluate serum soluble Flt-1 (sFlt-1) in age-related degeneration (AMD) patients.
DESIGN: Case control study.
METHODS: Fifty-six non-AMD participants, fifty-three early AMD patients and ninety-seven neovascular AMD patients from Belfast in Northern Ireland. Serum samples were collected from each patient. Serum sFlt-1 was measured by human sVEGFR1/sFlt-1 ELISA kit. The results were analyzed by Excel and SPSS.
RESULTS: Serum sFlt-1 concentration of non-AMD, early AMD, and neovascular AMD were 90.8±2.9 pg/mL (±SEM), 88.2±2.6 pg/mL and 79.9±2.2 pg/mL. sFlt-1 from neovascular AMD patients was significantly decreased compared to non-AMD and early AMD patients (ANOVA, p<0.01). For each 10 point increase in sFlt-1, the odds for having neovascular AMD compared with non-AMD and neovascular AMD decreases by 27.8% OR=0.722 (95% CI: 0.588-0.888, p=0.002) and 27.0% OR=0.730 (95% CI: 0.594-0.898, p=0.003), respectively. In patients over 73 years of age, serum sFlt-1 <80 pg/mL was associated with a >6-fold higher risk of neovascular AMD.
CONCLUSIONS: Reduced serum sFlt-1 differentiates those patients with neovascular AMD from both early AMD and non-AMD participants. In those aged over 73, serum sFlt <80 pg/mL seems to indicate a particularly high risk of neovascular AMD. Our results indicate serum sFlt-1 could be a biomarker for development of neovascular AMD.
Resumo:
Results for energy levels, radiative rates and electron impact excitation (effective) collision strengths for transitions in Be-like Cl XIV, K XVI and Ge XXIX are reported. For the calculations of energy levels and radiative rates the general-purpose relativistic atomic structure package is adopted, while for determining the collision strengths and subsequently the excitation rates, the Dirac atomic R-matrix code is used. Oscillator strengths, radiative rates and line strengths are listed for all E1, E2, M1 and M2 transitions among the lowest 98 levels of the n ≤ 4 configurations. Furthermore, lifetimes are provided for all levels and comparisons made with available theoretical and experimental results. Resonances in the collision strengths are resolved in a fine energy mesh and averaged over a Maxwellian velocity distribution to obtain the effective collision strengths. Results obtained are listed over a wide temperature range up to 107.8 K, depending on the ion.
Resumo:
Energy levels and radiative rates are reported for transitions in Cl-like W LVIII. Configuration interaction (CI) has been included among 44 configurations (generating 4978 levels) over a wide energy range up to 363 Ryd, and the general-purpose relativistic atomic structure package (grasp) adopted for the calculations. Since no other results of comparable complexity are available, calculations have also been performed with the flexible atomic code (fac), which help in assessing the accuracy of our results. Energies are listed for the lowest 400 levels (with energies up to ~98 Ryd), which mainly belong to the 3s23p5, 3s3p6, 3s23p43d, 3s23p33d2, 3s3p43d2, 3s23p23d3, and 3p63d configurations, and radiative rates are provided for four types of transitions, i.e.E1, E2, M1, and M2. Our energy levels are assessed to be accurate to better than 0.5%, whereas radiative rates (and lifetimes) should be accurate to better than 20% for a majority of the strong transitions.
Resumo:
Energy levels and radiative rates are reported for transitions in Br-like tungsten, W XL, calculated with the general-purpose relativistic atomic structure package (grasp). Configuration interaction (CI) has been included among 46 configurations (generating 4215 levels) over a wide energy range up to 213 Ryd. However, for conciseness results are only listed for the lowest 360 levels (with energies up to ~43 Ryd), which mainly belong to the 4s24p5,4s24p44d,4s24p44f,4s4p6,4p64d,4s4p54d,4s24p34d2, and 4s24p34d4f configurations, and provided for four types of transitions, E1, E2, M1, and M2. Comparisons are made with existing (but limited) results. However, to fully assess the accuracy of our data, analogous calculations have been performed with the flexible atomic code, including an even larger CI than in grasp. Our energy levels are estimated to be accurate to better than 0.02 Ryd, whereas results for radiative rates (and lifetimes) should be accurate to better than 20% for a majority of the strong transitions.
Resumo:
Energy levels, radiative rates and lifetimes are calculated among the lowest 98 levels of the n ≤4 configurations of Be-like Al X. The GRASP (General-purpose Relativistic Atomic Structure Package) is adopted and data are provided for all E1, E2, M1 and M2 transitions. Similar data are also obtained with the FAC (Flexible Atomic Code) to assess the accuracy of the calculations. Based on comparisons between calculations with the two codes as well as with available measurements, our listed energy levels are assessed to be accurate to better than 0.3 per cent. However, the accuracy for radiative rates and lifetimes is estimated to be about 20 per cent. Collision strengths are also calculated for which the DARC (Dirac Atomic R-matrix Code) is used. A wide energy range (up to 380 Ryd) is considered and resonances resolved in a fine energy mesh in the thresholds region. The collision strengths are subsequently averaged over a Maxwellian velocity distribution to determine effective collision strengths up to a temperature of 1.6 × 107 K. Our results are compared with the previous (limited) atomic data and significant differences (up to a factor of 4) are noted for several transitions, particularly those which are not allowed in jj coupling.
Resumo:
Energies for the lowest 56 levels, belonging to the 3s2 3p, 3s 3p2, 3p3, 3s2 3d, 3s 3p 3d, 3s2 4ℓ and 3s2 5ℓ configurations of Si II, are calculated using the General-purpose Relativistic Atomic Structure Package (GRASP) code. Analogous calculations have also been performed (for up to 175 levels) using the FlexibleAtomicCode (FAC). Furthermore, radiative rates are calculated for all E1, E2, M1 and M2 transitions. Extensive comparisons are made with available theoretical and experimental energy levels, and the accuracy of the present results is assessed to be better than 0.1Ryd. Similarly, the accuracy for radiative rates (and subsequently lifetimes) is estimated to be better than 20 per cent for most of the (strong) transitions. Electron impact excitation collision strengths are also calculated, with the Dirac Atomic R-matrix Code (DARC), over a wide energy range up to 13 Ryd. Finally, to determine effective collision strengths, resonances are resolved in a fine energy mesh in the thresholds region. These collision strengths are averaged over a Maxwellian velocity distribution and results listed over a wide range of temperatures, up to 105.5 K. Our data are compared with earlier R-matrix calculations and differences noted, up to a factor of 2, for several transitions. Although scope remains for improvement, the accuracy for our results of collision strengths and effective collision strengths is assessed to be about 20 per cent for a majority of transitions.
Resumo:
We report calculations of energy levels, radiative rates, oscillator strengths and line strengths for transitions among the lowest 231 levels of Ti VII. The general-purpose relativistic atomic structure package and flexible atomic code are adopted for the calculations. Radiative rates, oscillator strengths and line strengths are provided for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2) and magnetic quadrupole (M2) transitions among the 231 levels, although calculations have been performed for a much larger number of levels (159 162). In addition, lifetimes for all 231 levels are listed. Comparisons are made with existing results and the accuracy of the data is assessed. In particular, the most recent calculations reported by Singh et al (2012 Can. J. Phys. 90 833) are found to be unreliable, with discrepancies for energy levels of up to 1 Ryd and for radiative rates of up to five orders of magnitude for several transitions, particularly the weaker ones. Based on several comparisons among a variety of calculations with two independent codes, as well as with the earlier results, our listed energy levels are estimated to be accurate to better than 1% (within 0.1 Ryd), whereas results for radiative rates and other related parameters should be accurate to better than 20%.
Resumo:
We report on calculations of energy levels, radiative rates, oscillator strengths and line strengths for transitions among the lowest 253 levels of the (1s22s22p6 ) 3s23p5 , 3s3p6 , 3s23p43d, 3s3p53d, 3s23p33d2 , 3s23p44s, 3s23p44p and 3s23p44d configurations of Ti VI. The general-purpose relativistic atomic structure package and flexible atomic code are adopted for the calculations. Radiative rates, oscillator strengths and line strengths are reported for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2) and magnetic quadrupole (M2) transitions among the 253 levels, although calculations have been performed for a much larger number of levels. Comparisons are made with existing available results and the accuracy of the data is assessed. Additionally, lifetimes for all 253 levels are listed, although comparisons with other theoretical results are limited to only 88 levels. Our energy levels are estimated to be accurate to better than 1% (within 0.03 Ryd), whereas results for other parameters are probably accurate to better than 20%. A reassessment of the energy level data on the National Institute of Standards and Technology website for Ti VI is suggested.
Resumo:
We report calculations of energy levels, radiative rates, oscillator strengths and line strengths for transitions among the lowest 345 levels of Ti X. These include 146 levels of the n 3 configurations and 86 of 3s 24ℓ, 3s25ℓ and 3s3p4ℓ, plus some of the 3s26ℓ, 3p24ℓ and 3s3p5ℓ levels. The general-purpose relativistic atomic structure package and flexible atomic code are adopted for the calculations. Radiative rates, oscillator strengths and line strengths are provided for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2) and magnetic quadrupole (M2) transitions among the 345 levels, although calculations have been performed for a much larger number of levels. Comparisons are made with existing results and the accuracy of the data is assessed. Additionally, lifetimes for all 345 levels are listed. Extensive comparisons of lifetimes are made for the lowest 40 levels, for which discrepancies with recent theoretical work are up to 30%. Discrepancies in lifetimes are even larger, up to a factor of four, for higher excited levels. Furthermore, the effect of large configuration interaction (CI) is found to be insignificant for both the energies and lifetimes for the lowest 40 levels of Ti X which belong to the 3s23p, 3s3p2, 3s23d, 3p3 and 3s3p3d configurations. However, the contribution of CI is more appreciable for the energy levels and radiative rates among higher excited levels. Our listed energy levels are estimated to be accurate to better than 1% (within 0.1 Ryd), whereas results for other parameters are probably accurate to better than 20%. © 2013 The Royal Swedish Academy of Sciences.