993 resultados para Multi-loop Linkages
Resumo:
This paper uses a database covering the universe of French firms for the period 1990-2007 to provide a forensic account of the role of individual firms in generating aggregatefluctuations. We set up a simple multi-sector model of heterogeneous firms selling tomultiple markets to motivate a theoretically-founded decomposition of firms' annualsales growth rate into different components. We find that the firm-specific componentcontributes substantially to aggregate sales volatility, mattering about as much as thecomponents capturing shocks that are common across firms within a sector or country.We then decompose the firm-specific component to provide evidence on two mechanismsthat generate aggregate fluctuations from microeconomic shocks highlighted in the recentliterature: (i) when the firm size distribution is fat-tailed, idiosyncratic shocks tolarge firms directly contribute to aggregate fluctuations; and (ii) aggregate fluctuationscan arise from idiosyncratic shocks due to input-output linkages across the economy.Firm linkages are approximately three times as important as the direct effect of firmshocks in driving aggregate fluctuations.
Resumo:
The omega-loop gastric bypass (OLGBP), also called "mini-gastric bypass" or "single-anastomosis" gastric bypass is a form of gastric bypass where a long, narrow gastric pouch is created and anastomosed to the jejunum about 200- 250 cm from the angle of Treitz in an omega loop fashion, thereby avoiding a jejuno-jejunostomy.Proponents of the OLGBP claim that it is a safer and simpler operation than the traditional Roux-en-Y gastric bypass (RYGBP), easier to teach, that gives the same results in terms of weight loss than the RYGBP. One randomized study comparing the two techniques showed similar results after five years.The OLGBP is criticized because it creates an anastomosis between the gastric pouch and the jejunum where a large amount of biliopancreatic juices travel, thereby creating a situation where reflux of the latter into the stomach and distal esophagus is likely to develop. Such a situation has clearly been associated, in several animal studies, with an increased incidence of gastric cancer, especially at or close to the gastro-jejunostomy, and with an increased risk of lower esophageal cancer. In clinical practice, omega-loop gastrojejunostomies such as those used for reconstruction after gastric resection for benign disease or distal gastric cancer have been associated with the so called classical anastomotic cancer, linked to biliary reflux into the stomach, despite the fact that epidemiological studies about this do not show uniform results. Although no evidence at the present time links OLGBP to an increased risk of gastric cancer in the human, this possibility raises a concern among many bariatric surgeons, especially in the view that bariatric surgery is performed in relatively young patients with a long life expectancy, hence prone to develop cancer if indeed the risk is increased. Another arguments used against the OLGBP is that the jejuno-jejunostomy in the traditional RYGBP is easy to perform and associated with virtually no complication.Supporters of the OLGBP claim that the liquid that refluxes into the stomach after their procedure is not pure bile and pancreatic juice, but a combination of those with jejunal secretions, and that the latter is not as harmful. We would urge the proponents of the OLGBP to undertake the necessary animal studies to show that their assumption is indeed true before the procedure is performed widely, possibly leading to the development of hundreds of late gastric or esophageal carcinoma in the bariatric population. In the meantime, we strongly believe that RYGBP should remain the gold standard in gastric bypass surgery for morbid obesity.
Resumo:
This letter presents advanced classification methods for very high resolution images. Efficient multisource information, both spectral and spatial, is exploited through the use of composite kernels in support vector machines. Weighted summations of kernels accounting for separate sources of spectral and spatial information are analyzed and compared to classical approaches such as pure spectral classification or stacked approaches using all the features in a single vector. Model selection problems are addressed, as well as the importance of the different kernels in the weighted summation.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.
Resumo:
Amnestic mild cognitive impairment (aMCI) is characterized by memory deficits alone (single-domain, sd-aMCI) or associated with other cognitive disabilities (multi-domain, md-aMCI). The present study assessed the patterns of electroencephalographic (EEG) activity during the encoding and retrieval phases of short-term memory in these two aMCI subtypes, to identify potential functional differences according to the neuropsychological profile. Continuous EEG was recorded in 43 aMCI patients, whose 16 sd-aMCI and 27 md-aMCI, and 36 age-matched controls (EC) during delayed match-to-sample tasks for face and letter stimuli. At encoding, attended stimuli elicited parietal alpha (8-12 Hz) power decrease (desynchronization), whereas distracting stimuli were associated with alpha power increase (synchronization) over right central sites. No difference was observed in parietal alpha desynchronization among the three groups. For attended faces, the alpha synchronization underlying suppression of distracting letters was reduced in both aMCI subgroups, but more severely in md-aMCI cases that differed significantly from EC. At retrieval, the early N250r recognition effect was significantly reduced for faces in md-aMCI as compared to both sd-aMCI and EC. The results suggest a differential alteration of working memory cerebral processes for faces in the two aMCI subtypes, face covert recognition processes being specifically altered in md-aMCI.
Resumo:
Each agency is invited and encouraged to send a representative to a quarterly Department of Administrative Services State Recruitment Coordinating Committee “Committee” meeting. This Committee conducts strategic planning sessions to identify top goals and initiatives for the next 2-3 years.
Resumo:
PURPOSE: Recurrent head and neck cancer is associated to a poor survival prognosis. A high toxicity rate is demonstrated when surgery and/or radiotherapy and/or chemotherapy are combined. Furthermore, the duration of treatment is often not ethically compatible with the expected survival (median survival<1year). Normal tissues tolerance limits the use of reirradiation and stereotactic body radiotherapy (SBRT) could offer precise irradiation while sparing healthy tissues. After completion of a feasibility study, results of a multicentric study (Lille, Nancy & Nice) using SBRT with cetuximab are reported. The aim of the study was to deliver non toxic short course SBRT (2weeks) in order to get the same local control as the one demonstrated with longer protocols. METHODS AND MATERIALS: Patients with inoperable recurrent, or new primary tumor in a previously irradiated area, were included (WHO<3). Reirradiation (RT) dose was 36Gy in six fractions of 6Gy to the 85% isodose line covering 95% of the PTV with 5 injections of concomitant cetuximab (CT). All patients had previous radiotherapy, 85% had previous surgery and 48% previous chemotherapy. RESULTS: Between 11/2007 and 08/2010, 60 were included (46 men and 14 women), 56 received CT+RT, 3 were not treated and 1 received only CT. Median age was 60 (42-87)) and all 56 patients had squamous carcinoma and received concomitant cetuximab. Mean time between previous radiotherapy and the start of SBRT was 38months. Cutaneous toxicity was observed for 41 patients. There was one toxic death from hemorrhage and denutrition. Median follow-up was 11.4months. At 3months, response rate was 58.4% (95% CI: 43.2-72.4%) and disease control rate was 91.7% (95% CI: 80.0-97.7%). The one-year OS rate was 47.5% (95% CI: 30.8-62.4). CONCLUSION: These results suggest that short SBRT with cetuximab is an effective salvage treatment with good response rate in this poor prognosis population with previously irradiated HNC. Treatment is feasible and, with appropriate care to limiting critical structure, acute toxicities are acceptable. This combination may be the reference treatment is this population.
Resumo:
This report proposes, that for certain types of highway construction projects undertaken by the Iowa Department of Transportation, a scheduling technique commonly referred to as linear scheduling may be more effective than the Critical Path Method scheduling technique that is currently being used. The types of projects that appear to be good candidates for the technique are those projects that have a strong linear orientation. Like a bar chart, this technique shows when an activity is scheduled to occur and like a CPM schedule it shows the sequence in which activities are expected to occur. During the 1992 construction season, the authors worked with an inlay project on Interstate 29 to demonstrate the linear scheduling technique to the Construction Office. The as-planned schedule was developed from the CPM schedule that the contractor had developed for the project. Therefore, this schedule represents what a linear representation of a CPM schedule would look like, and not necessarily what a true linear schedule would look like if it had been the only scheduling technique applied to the project. There is a need to expand the current repertoire of scheduling techniques to address those projects for which the bar chart and CPM may not be appropriate either because of the lack of control information or due to overly complex process for the actual project characteristics. The scheduling approaches used today on transportation projects have many shortcomings for properly modeling the real world constraints and conditions which are encountered. Linear project's predilection for activities with variable production rates, a concept very difficult to handle with the CPM, is easily handled and visualized with the linear technique. It is recommended that work proceed with the refinement of the method of linear scheduling described above and the development of a microcomputer based system for use by the Iowa Department of Transportation and contractors for its implementation. The system will be designed to provide the information needed to adjust schedules in a rational understandable method for monitoring progress on the projects and alerting Iowa Department of Transportation personnel when the contractor is deviating from the plan.
Resumo:
OBJECTIVE: To determine whether infusion line compliance contributes to irregular drug delivery during vertical displacement of syringe pumps. DESIGN: Five different commercially available infusion lines were studied at infusion rates of 0.5, 1.0, and 1.5 ml/h. Zero drug delivery time was measured after acute line loop formation (70 cm) using an electronic balance. Compliance of each infusion line was calculated using a pressure transducer and measurement of the occlusion release bolus at 300 mmHg occlusion pressure. Finally, the influence of infusion line compliance on drug delivery during acute lowering of the syringe pump was studied using low- and high-compliance infusion lines. RESULTS: Acute line loop formation resulted in zero drug delivery time from 5.1 +/- 1.5 to 44.0 +/- 6.8 s at flow rates of 0.5 ml/h. Increased flow rates significantly reduced loop-induced flow variability. A close correlation was found between zero drug delivery time and calculated infusion line compliance at 0.5 ml/h (linear regression R2 = 0.79). Lowering of the syringe pump 50 cm prolonged zero drug delivery time from 295.8 +/- 20.7 s with the low-compliance tube to 463.3 +/- 24.0 s with the high-compliance infusion line. CONCLUSIONS: Infusion line compliance contributes to irregular drug delivery associated with vertical displacement of syringe pumps. Siphoning of the infusion line during patient care should be avoided, and flow rates of 1 ml/h or higher are recommended. Low-compliance infusion lines are indicated whenever highly short-acting vasoactive drugs at low delivery rates are administered.
Resumo:
Multi-center studies using magnetic resonance imaging facilitate studying small effect sizes, global population variance and rare diseases. The reliability and sensitivity of these multi-center studies crucially depend on the comparability of the data generated at different sites and time points. The level of inter-site comparability is still controversial for conventional anatomical T1-weighted MRI data. Quantitative multi-parameter mapping (MPM) was designed to provide MR parameter measures that are comparable across sites and time points, i.e., 1 mm high-resolution maps of the longitudinal relaxation rate (R1 = 1/T1), effective proton density (PD(*)), magnetization transfer saturation (MT) and effective transverse relaxation rate (R2(*) = 1/T2(*)). MPM was validated at 3T for use in multi-center studies by scanning five volunteers at three different sites. We determined the inter-site bias, inter-site and intra-site coefficient of variation (CoV) for typical morphometric measures [i.e., gray matter (GM) probability maps used in voxel-based morphometry] and the four quantitative parameters. The inter-site bias and CoV were smaller than 3.1 and 8%, respectively, except for the inter-site CoV of R2(*) (<20%). The GM probability maps based on the MT parameter maps had a 14% higher inter-site reproducibility than maps based on conventional T1-weighted images. The low inter-site bias and variance in the parameters and derived GM probability maps confirm the high comparability of the quantitative maps across sites and time points. The reliability, short acquisition time, high resolution and the detailed insights into the brain microstructure provided by MPM makes it an efficient tool for multi-center imaging studies.
Resumo:
Cases of fatal outcome after surgical intervention are autopsied to determine the cause of death and to investigate whether medical error caused or contributed to the death. For medico-legal purposes, it is imperative that autopsy findings are documented clearly. Modern imaging techniques such as multi-detector computed tomography (MDCT) and postmortem CT angiography, which is used for vascular system imaging, are useful tools for determining cause of death. The aim of this study was to determine the utility of postmortem CT angiography for the medico-legal death investigation. This study investigated 10 medico-legal cases with a fatal outcome after surgical intervention using multi-phase postmortem whole body CT angiography. A native CT scan was performed as well as three angiographic phases (arterial, venous, and dynamic) using a Virtangio((R)) perfusion device and the oily contrast agent, Angiofil((R)). The results of conventional autopsy were compared to those from the radiological investigations. We also investigated whether the radiological findings affected the final interpretation of cause-of-death. Causes of death were hemorrhagic shock, intracerebral hemorrhage, septic shock, and a combination of hemorrhage and blood aspiration. The diagnoses were made by conventional autopsy as well as by postmortem CT angiography. Hemorrhage played an important role in eight of ten cases. The radiological exam revealed the exact source of bleeding in seven of the eight cases, whereas conventional autopsy localized the source of bleeding only generally in five of the seven cases. In one case, neither conventional autopsy nor CT angiography identified the source of hemorrhage. We conclude that postmortem CT angiography is extremely useful for investigating deaths following surgical interventions. This technique helps document autopsy findings and allows a second examination if it is needed; specifically, it detects and visualizes the sources of hemorrhages in detail, which is often of particular interest in such cases.
Resumo:
The effect of motor training using closed loop controlled Functional Electrical Stimulation (FES) on motor performance was studied in 5 spinal cord injured (SCI) volunteers. The subjects trained 2 to 3 times a week during 2 months on a newly developed rehabilitation robot (MotionMaker?). The FES induced muscle force could be adequately adjusted throughout the programmed exercises by the way of a closed loop control of the stimulation currents. The software of the MotionMaker? allowed spasms to be detected accurately and managed in a way to prevent any harm to the SCI persons. Subjects with incomplete SCI reported an increased proprioceptive awareness for motion and were able to achieve a better voluntary activation of their leg muscles during controlled FES. At the end of the training, the voluntary force of the 4 incomplete SCI patients was found increased by 388% on their most affected leg and by 193% on the other leg. Active mobilisation with controlled FES seems to be effective in improving motor function in SCI persons by increasing the sensory input to neuronal circuits involved in motor control as well as by increasing muscle strength.