960 resultados para Food-specific satiety


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented at Faculdade de Ciências e Tecnologia from Universidade Nova de Lisboa to obtain the degree of Master in Chemical and Biochemical Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The precise microenvironment of Paracoccidioides brasiliensis has not yet been discovered perhaps because the methods used are not sensitive enough. We applied to this purpose the polymerase chain reaction (PCR) using three sets of specific primers corresponding to two P. brasiliensis genes. This fungus as well as several other fungi, were grown and their DNA obtained by mechanical disruption and a phenol chloroform isoamylalcohol-based purification method. The DNA served for a PCR reaction that employed specific primers from two P. brasiliensis genes that codify for antigenic proteins, namely, the 27 kDa and the 43 kDa. The lowest detection range for the 27 kDa gene was 3 pg. The amplification for both genes was positive only with DNA from P. brasiliensis; additionally, the mRNA for the 27 kDa gene was present only in P. brasiliensis, as indicated by the Northern analysis. The standardization of PCR technology permitted the amplification of P. brasiliensis DNA in artificially contaminated soils and in tissues of armadillos naturally infected with the fungus. These results indicate that PCR technology could play an important role in the search for P. brasiliensis’ habitat and could also be used in other ecological studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The circumoval precipitin test (COPT), enzyme-linked immunosorbent assay (ELISA) and the immunoblotting anti-adult worm antigen (AWA) and soluble egg antigen (SEA) tests were applied to 17 chronically schistosome-infected patients for the detection of anti-Schistosoma mansoni antibodies before and on four occasions after oxamniquine administration over a period of six months. Compared to a control group, schistosomiasis patients showed high levels of IgG antibodies in AWA and SEA-ELISA. A decrease in IgG levels was observed six months after treatment, although negative reactions were not obtained. Significant decreases in IgG1, IgG3 and, mainly, IgG4, but not anti-SEA IgG2 levels were observed six months after treatment, again without negativity. Analysis of anti-AWA IgG antibodies by immunoblotting before treatment showed a 31 kDa strand in 14 patients (82%) which disappeared in three cases up to six months after treatment; furthermore, anti-SEA IgG antibodies showed the same band in nine patients (53%) before treatment, which disappeared in only four cases up to six months after treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Coronary artery disease are associated with decreased levels of physical activity, contributing to increases in abdominal fat and consequently the metabolic risk. The use of microcurrents is an innovative and effective method to increase lipolytic rate of abdominal adipocytes. This study aims to investigate the effects of microcurrents with a homebased exercise program on total, subcutaneous and visceral abdominal adipose tissue in subjects with coronary artery disease. Methods: This controlled trial included 44 subjects with myocardial infarction, randomly divided into Intervention Group 1 (IG1; n = 16), Intervention Group 2 (IG2; n = 12) and Control Group (CG; n = 16). IG1 performed a specific exercise program at home during 8 weeks, and IG2 additionally used microcurrents on the abdominal region before the exercise program. All groups were subjected to health education sessions. Computed Tomography was used to evaluate abdominal, subcutaneous and visceral fat, accelerometers to measure habitual physical activity and the semiquantitative Food Frequency Questionnaire for dietary intake. Results: After 8 weeks, IG2 showed a significantly decreased in subcutaneous fat (p ≤ 0.05) when compared to CG. Concerning visceral fat, both intervention groups showed a significant decrease in comparison to the CG (p ≤ 0.05). No significant changes were found between groups on dietary intake and habitual physical activity, except for sedentary activity that decreased significantly in IG2 in comparison with CG (p ≤ 0.05). Conclusions: This specific exercise program showed improvements in visceral fat in individuals with coronary artery disease. Microcurrent therapy associated with a home-based exercise program suggested a decreased in subcutaneous abdominal fat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

272 isolates of Salmonella Enteritidis (111 isolated from frozen broiler chicken carcasses, 126 from human food and other biological materials involved in food poisoning outbreaks and 35 from different poultry materials) were selected for phage typing. From these, 111 were phage typed, 57.65% being classified as phage type 4, 32.43% as phage type 4a, 3.60% as phage type 6a and 0.90% as phage type 7, whereas 5.40% samples were not phage typeable. The predominance of phage type 4 is in agreement with the results published worldwide, and reinforces the need for studies related to the epidemiological meaning of these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - Visa-se explicitar a origem, a razão de ser, a natureza e o que se perspectiva da relação entre a Epidemiologia e a Saúde Pública, através de uma leitura histórica. As duas entidades foram-se definindo e fazendo sentido em conjunto, com sucessos e, também, muita polémica, desde há milénios e até meados do século XIX. Nesta época, uma combinação de circunstâncias proporcionou-lhes uma explosão de crescimento e de definição, de par com várias outras áreas disciplinares. Desde o antigo relato bíblico de como boa alimentação explica o bom estado de saúde, até à valorização científica das condicionantes sociais e económicas da saúde por Marmot e Rose, passando por «miasmas» causando doença e pela deslocação do conceito de risco individual de saúde para o de risco populacional — com as implicações inerentes a essa importante inovação —, este percurso permite identificar as fundações de tão notável simbiose, explicar o estado presente, vê-la evoluir e achar nela o significado do património hoje disponível, e o que ele promete. Algumas discrepâncias quanto à designação dos seus métodos, bem como a contínua discussão quanto à sua verdadeira natureza e orientação futura, atestam a juventude da Epidemiologia como disciplina científica. Entretanto, a Saúde Pública esforça-se por manter a sua essência integradora, à medida que outras disciplinas contribuem mais para que concretize os seus objectivos; é desafiada pela exposição das populações, em larga escala, a factores de doença, por vezes de intensidade mínima, e pelo surgimento de novas doenças ou a ampliação do volume de outras na população, muitas vezes não respeitando fronteiras. A história dessa simbiose mostra bem que conhecer o modo como uma doença se origina permite controlá-la na população, ou mesmo evitá-la, e que é grande o número de problemas que, em sinergia, as duas disciplinas podem clarificar e resolver. Assim, a Epidemiologia oferece à Saúde Pública explicações (olhos, inteligência e linguagem) para os problemas de saúde das populações — o que permite à segunda saber sobre o quê agir —, cenários de possível evolução dos problemas — o que permite aos decisores optarem em função de diferentes pressupostos, sobre como agir — e capacidade de juízo sobre os resultados das acções empreendidas, em simultâneo com a elevação do nível de consciência, de compreensão e de intervenção quanto ao que se está a passar, tanto pelos profissionais, como pela população — transferência do conhecimento. Facilmente se antecipa que a relação entre as duas disciplinas irá evoluir para maior complexidade e, também, solicitação e exigência da Saúde Pública sobre a Epidemiologia, que terá que corresponder em utilidade. E esta, continuando a subespecializar-se e a sofisticar-se tanto nos métodos, como nos enfoques sobre categorias específicas de factores, precisará de progredir muito na gestão da sua consistência enquanto corpo de conhecimento integrado e com peculiaridades metodológicas, à semelhança da Saúde Pública.O modo como evoluirá a relação entre ambas depende ainda da evolução dos próprios problemas, conceitos, teorias e soluções relacionados com a saúde das populações, e ainda do desenvolvimento das demais disciplinas chamadas à integração por ambas, para enfrentarem esses desafios. Nomeadamente, a Epidemiologia terá que gerir com perícia dificuldades já identificadas, como: incorporar métodos qualitativos de investigação na sua fortíssima tradição e cultura quantitativa; operacionalizar satisfatoriamente o conceito de «risco atribuível na população», ao serviço da definição de prioridades de acção dirigida às necessidades de saúde; aperfeiçoar modelos de interpretação causal que respeitem a multicausalidade; aproveitar as técnicas estatísticas de análise multivariada, sem se perder na abstracção dos seus modelos; desenvolver a investigação nas dimensões positivas de saúde, além da doença, para contribuir melhor para a realização da Saúde Pública, sua principal cliente e fornecedora de oportunidades.--------------------------ABSTRACT - The aim of the author is to explicit the origin, the rationale, the nature and the prospects of the relationship between Epidemiology and Public health, through an historic approach. The two entities have been defining and making sense together, by achieving successes, but also with much controversy, since millennia ago, until mid XIX century. A combination of circumstances provided them the opportunity for an explosion of growth and definition, then, alongside several other disciplines. From the ancient biblical report on how good food explains good health, up to the scientific appreciation of both social and economical constraints to health by Marmot and Rose, passing through «miasma» causing disease and through displacing from individual health risk to population risk — with the inherent implications of that important innovation —, this route allows the identification of the foundations of such remarkable symbiosis, the explanation of current status, to see its evolution and find in it the meaning of today’s heritage and what it promises. Some discrepancies on the name of its methods, as well as the continuing discussion about its true nature and future orientation, attest Epidemiology’s youth as a scientific discipline. Meanwhile, Public Health strives to keep its integrating essence, while other disciplines increasingly contribute so that it achieves its objectives; it is challenged by large scale population exposure to disease factors, sometimes with a minimum intensity, and by new diseases emerging in the population or by old ones getting amplified, often not respecting regions boundaries. The history of such a symbiosis shows that knowing the way a disease is generated allows to control it in the population, or even to avoid it, and that the number of problems that the two disciplines are able to clarify and solve together in synergy is considerable. Therefore, Epidemiology offers Public Health explanations (eyes, intelligence and language) for populations’s health problems — allowing that the latter knows on what to act —, scenarios on how problems may tend to evolve — allowing decision-makers to make their choices as a function of different assumptions, on how to act — and judgement capabilities on the results of already undertaken actions, accompanied by the raising of conscience level, understanding and intervention of what is going on by both professionals and the population – knowledge transfer. It is easy to anticipate that the relationship between both disciplines will develop towards increasing complexity and demand from Public Health to Epidemiology, and that this one will have to correspond in usefulness. And the latter, while continuing its subspecialisation and sophistication either in its methods, or in its approaches to specific factor categories, will need to progress in managing its consistency as an integrated body of knowledge having methodological peculiarities, similarly to Public Health. Further, the way the relationship between both will evolve depends on the evolution of the problems themselves, of the concepts, theories and solutions related to the health of populations, and on the development of remaining disciplines called to integration by both, in other to face those problems. Namely, Epidemiology will have to manage with expertise some already known difficulties, as: the inclusion of qualitative research methods in its very strong quantitative tradition and culture; to grant satisfactory operation to the «population attributable risk» concept, in support to the definition of action priorities envisaging health needs; to improve causal interpretation models that comply with multicausality; to take advantage of multivariate statistical techniques, without get

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A serological survey of Toxoplasma gondii infection in blood donors was carried out in order to identify seroprevalence in Recife, Brazil. Sera from 160 individuals (119 male and 41 female) were evaluated by using a Toxoplasma IgG-antibody enzyme immunoassay (Denka Seiken Co., LTD., Tokyo, Japan). The seropositive percentual for males (79.0%) showed to be higher (p < 0.05) than for females (63.4%). This percentage increases with age, ranging from 18.2% to 92.6% for individuals aging under 20 and 40-50 years old, respectively. For women of childbearing age (18-40 years) it was found a prevalence of 51.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the standardization and evaluation of an in-house specific IgG avidity ELISA for distinguishing recent primary from long-term human cytomegalovirus (HCMV) infection. The test was standardized with the commercial kit ETI-CYTOK G Plus (Sorin Biomedica, Italy) using 8 M urea in phosphate-buffered saline to dissociate low-avidity antibodies after the antigen-antibody interaction. The performance of the in-house assay was compared to that of the commercial automated VIDAS CMV IgG avidity test (bioMérieux, France). Forty-nine sera, 24 from patients with a recent primary HCMV infection and 25 from patients with a long-term HCMV infection and a sustained persistence of specific IgM antibodies, were tested. Similar results were obtained with the two avidity methods. All 24 sera from patients with recently acquired infection had avidity indices compatible with acute HCMV infection by the VIDAS method, whereas with the in-house method, one serum sample had an equivocal result. In the 25 sera from patients with long-term infection, identical results were obtained with the two methods, with only one serum sample having an incompatible value. These findings suggest that our in-house avidity test could be a potentially useful tool for the immunodiagnosis of HCMV infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mV/Δlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL−1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ± 0.7%), fast response, good sensitivity (47 mV/Δlog([ENR]/M), wide linear range (1.0 × 10−5–1.0 × 10−3 M), low detection limit (0.9 µg mL−1), and a stable baseline for a 5 × 10−2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.