927 resultados para FULL BIODEGRADABLE
Resumo:
Aberrations of the acoustic wave front, caused by spatial variations of the speed-of-sound, are a main limiting factor to the diagnostic power of medical ultrasound imaging. If not accounted for, aberrations result in low resolution and increased side lobe level, over all reducing contrast in deep tissue imaging. Various techniques have been proposed for quantifying aberrations by analysing the arrival time of coherent echoes from so-called guide stars or beacons. In situations where a guide star is missing, aperture-based techniques may give ambiguous results. Moreover, they are conceptually focused on aberrators that can be approximated as a phase screen in front of the probe. We propose a novel technique, where the effect of aberration is detected in the reconstructed image as opposed to the aperture data. The varying local echo phase when changing the transmit beam steering angle directly reflects the varying arrival time of the transmit wave front. This allows sensing the angle-dependent aberration delay in a spatially resolved way, and thus aberration correction for a spatially distributed volume aberrator. In phantoms containing a cylindrical aberrator, we achieved location-independent diffraction-limited resolution as well as accurate display of echo location based on reconstructing the speed-of-sound spatially resolved. First successful volunteer results confirm the clinical potential of the proposed technique.
Resumo:
This study presents static measurements of the Ca isotopic composition of standard reference materials SRM 915 a/b on a Triton Plus™ thermal ionization mass spectrometer with a specially developed Faraday cup array allowing simultaneous measurement of 40Ca and 48Ca. The total amount of Ca in all analyses was kept < 1 µg. With this setup the measurement uncertainties were 0.06 ‰ for 40Ca/44Ca and 0.12 ‰ for 48Ca/40Ca. Measuring all isotopes simultaneously better allows to test the internal consistency of different Ca isotope abundances reported in the literature. The exponential law was observed to correct incompletely instrumental mass fractionation. An improved fractionation correction based on the exponential law is proposed. It changes the 40Ca/44Ca ratio of SRM 915a (corrected relative to 42Ca/44Ca = 0.31221; 48Ca/44Ca = 0.08871) from 47.1635 ± 0.0028 to 47.1649 ± 0.0047. The measurements of SRM 915b were performed with different analytical conditions (runs were prolonged till complete filament load depletion). Even if the 40Ca/44Ca ratio of SRM 915b, when corrected with the simple exponential law, appears different (47.1532 ± 0.0038) from that of SRM 915a, it becomes coincident (47.1613 ± 0.0028) when corrected with a second-order refinement. This supports the use of the improved exponential law to obtain internally consistent Ca isotope ratio for natural samples.
Resumo:
AIMS Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. METHODS AND RESULTS The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. CONCLUSIONS In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.
Resumo:
OBJECTIVE The purpose of this study was to examine the recurrence rate of wound rupture in primary pilonidal sinus disease (PSD) after median closure. SUBJECTS AND METHODS A total of 583 patients from the German military cohort were interviewed. We compared the choice of surgical therapy, wound dehiscence (if present) and long-term recurrence-free survival for patients with primary open treatment, marsupialization and primary median treatment (closed vs. secondary open, respectively). Actuarial recurrence rate was determined using the Kaplan-Meier calculation with a follow-up of up to 20 years after primary PSD surgery. RESULTS Patients with excision followed by primary open wound treatment showed a significantly lower 5- than 10-year recurrence rate (8.3 vs. 11.2%) compared to the patients with primary midline closure (17.4 vs. 20.5%, p = 0.03). The 20-year recurrence rate was 28% in primary open wound treatment versus 44% in primary midline closure without wound rupture. In contrast to these findings, long-term recurrence rates following secondary open wound treatment (12.2% at 5 years vs. 17.1% at 10 years) tended to be higher (although not significantly, p = 0.57) compared to primary open treatment (8.3% at 5 years vs. 11.2% at 10 years). There was no statistical difference in long-term recurrence rates between secondary open and primary midline closure (p = 0.7). Hence, despite only a short wound closure time experienced before wound rupture, the patient does not fully benefit from an open wound treatment in terms of recurrence rate. CONCLUSION The postoperative pilonidal sinus wound rupture of primary midline closures did not significantly increase the 5- and 10-year long-term recurrence rates compared to uneventfully healing primary midline closures.
Resumo:
Purpose: The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). Materials and Methods: 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. Results: The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. Conclusion: The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. Key Points: • The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %.• The diagnostic reference standard MSCT is the preferred and reliable imaging modality.• LS may be valuable for quick detection of extremity fractures. Citation Format: • Jöres APW., Heverhagen JT, Bonél H et al. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. Fortschr Röntgenstr 2016; 188: 163 - 171.
Resumo:
BACKGROUND No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polymer everolimus-eluting stents (DP-EES) in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS A total of 2119 patients with minimal exclusion criteria were assigned to treatment with BP-SES (n=1063) or DP-EES (n=1056). Follow-up at 2 years was available for 2048 patients (97%). The primary end point was target-lesion failure, a composite of cardiac death, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. At 2 years, target-lesion failure occurred in 107 patients (10.5%) in the BP-SES arm and 107 patients (10.4%) in the DP-EES arm (risk ratio [RR] 1.00, 95% CI 0.77-1.31, P=0.979). There were no significant differences between BP-SES and DP-EES with respect to cardiac death (RR 1.01, 95% CI 0.62-1.63, P=0.984), target-vessel myocardial infarction (RR 0.91, 95% CI 0.60-1.39, P=0.669), target-lesion revascularization (RR 1.17, 95% CI 0.81-1.71, P=0.403), and definite stent thrombosis (RR 1.38, 95% CI 0.56-3.44, P=0.485). There were 2 cases (0.2%) of definite very late stent thrombosis in the BP-SES arm and 4 cases (0.4%) in the DP-EES arm (P=0.423). In the prespecified subgroup of patients with ST-segment elevation myocardial infarction, BP-SES was associated with a lower risk of target-lesion failure compared with DP-EES (RR 0.48, 95% CI 0.23-0.99, P=0.043, Pinteraction=0.026). CONCLUSIONS Comparable safety and efficacy profiles of BP-SES and DP-EES were maintained throughout 2 years of follow-up. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.
Resumo:
A human interleukin 4 (hIL-4)-encoding cDNA (hIL4) probe was used to screen a bovine genomic library, and three clones containing sequences with homology to the human and mouse IL4 cDNAs were isolated. Sequence information obtained from one of these genomic clones was used to design an oligodeoxyribonucleotide primer corresponding to the transcription start point region for use in the polymerase chain reaction (PCR). The PCR-RACE protocol, designed for the rapid amplification of cDNA ends, was successfully used to generate a full-length bovine IL4 (bIL4) cDNA clone from polyadenylated RNA isolated from concanavalin A-stimulated bovine lymph node cells. The bIL4 cDNA is 570 bp in length and contains an open reading frame of 405 nucleotides (nt), coding for a 15.1-kDa precursor of 135 amino acids (aa), which should be reduced to 12.6 kDa for unglycosylated bIL4 after cleavage of a putative hydrophobic leader sequence of 24 aa. The aa sequence contains one possible Asn-linked glycosylation site. Bovine IL4 is shorter than mouse (mIL4) and hIL4, because of a 51-nt deletion in the coding region. Comparison of the overall nt and deduced aa sequences shows a greater homology of bIL4 with hIL4 than with mIL4. This homology is not evenly distributed, however, with the nt sequences 5' and 3' of the coding region showing a much greater homology between all three species than the coding sequence.
Resumo:
Introduction. Tissue engineering techniques offer a potential means to develop a tissue engineered construct (TEC) for the treatment of tissue and organ deficiencies. However, a lack of adequate vascularization is a limiting factor in the development of most viable engineered tissues. Vascular endothelial growth factor (VEGF) could aid in the development of a viable vascular network within TECs. The long-term goals of this research are to develop clinically relevant, appropriately vascularized TECs for use in humans. This project tested the hypothesis that the delivery of VEGF via controlled release from biodegradable microspheres would increase the vascular density and rate of angiogenesis within a model TEC. ^ Materials and methods. Biodegradable VEGF-encapsulated microspheres were manufactured using a novel method entitled the Solid Encapsulation/Single Emulsion/Solvent Extraction technique. Using a PLGA/PEG polymer blend, microspheres were manufactured and characterized in vitro. A model TEC using fibrin was designed for in vivo tissue engineering experimentation. At the appropriate timepoint, the TECs were explanted, and stained and quantified for CD31 using a novel semi-automated thresholding technique. ^ Results. In vitro results show the microspheres could be manufactured, stored, degrade, and release biologically active VEGF. The in vivo investigations revealed that skeletal muscle was the optimal implantation site as compared to dermis. In addition, the TECs containing fibrin with VEGF demonstrated significantly more angiogenesis than the controls. The TECs containing VEGF microspheres displayed a significant increase in vascular density by day 10. Furthermore, TECs containing VEGF microspheres had a significantly increased relative rate of angiogenesis from implantation day 5 to day 10. ^ Conclusions. A novel technique for producing microspheres loaded with biologically active proteins was developed. A defined concentration of microspheres can deliver a quantifiable level of VEGF with known release kinetics. A novel model TEC for in vivo tissue engineering investigations was developed. VEGF and VEGF microspheres stimulate angiogenesis within the model TEC. This investigation determined that biodegradable rhVEGF 165-encapsulated microspheres increased the vascular density and relative rate of angiogenesis within a model TEC. Future applications could include the incorporation of microvascular fragments into the model TEC and the incorporation of specific tissues, such as fat or bone. ^
Resumo:
Genetic anticipation is defined as a decrease in age of onset or increase in severity as the disorder is transmitted through subsequent generations. Anticipation has been noted in the literature for over a century. Recently, anticipation in several diseases including Huntington's Disease, Myotonic Dystrophy and Fragile X Syndrome were shown to be caused by expansion of triplet repeats. Anticipation effects have also been observed in numerous mental disorders (e.g. Schizophrenia, Bipolar Disorder), cancers (Li-Fraumeni Syndrome, Leukemia) and other complex diseases. ^ Several statistical methods have been applied to determine whether anticipation is a true phenomenon in a particular disorder, including standard statistical tests and newly developed affected parent/affected child pair methods. These methods have been shown to be inappropriate for assessing anticipation for a variety of reasons, including familial correlation and low power. Therefore, we have developed family-based likelihood modeling approaches to model the underlying transmission of the disease gene and penetrance function and hence detect anticipation. These methods can be applied in extended families, thus improving the power to detect anticipation compared with existing methods based only upon parents and children. The first method we have proposed is based on the regressive logistic hazard model. This approach models anticipation by a generational covariate. The second method allows alleles to mutate as they are transmitted from parents to offspring and is appropriate for modeling the known triplet repeat diseases in which the disease alleles can become more deleterious as they are transmitted across generations. ^ To evaluate the new methods, we performed extensive simulation studies for data simulated under different conditions to evaluate the effectiveness of the algorithms to detect genetic anticipation. Results from analysis by the first method yielded empirical power greater than 87% based on the 5% type I error critical value identified in each simulation depending on the method of data generation and current age criteria. Analysis by the second method was not possible due to the current formulation of the software. The application of this method to Huntington's Disease and Li-Fraumeni Syndrome data sets revealed evidence for a generation effect in both cases. ^
Resumo:
Objective. Although complete blood count (CBC) changes occur with the development of clinical sepsis in newborns, the CBC has not been reported to be a sensitive predictor of sepsis in asymptomatic full-term newborn infants, nor has it been reported to be related to risk factors for sepsis or clinical decisions. The objective of this study was to evaluate the relationship between the WBC/I:T (immature:total neutrophil) ratio and maternal group B streptococcal (GBS) risk factors (rupture of membranes ≥18 hours, maternal temperature ≥100.4°F, maternal age ≤20 years, previous infant with invasive GBS disease, maternal GBS bacteriuria, and black ethnicity); and to evaluate the relationship between the WBC/I:T ratios and providers' clinical decisions (observe versus repeat the CBC or complete sepsis evaluation) in the asymptomatic full-term newborn at risk for early-onset GBS sepsis. ^ Methods. Medical records of infants admitted to the well baby nursery at a tertiary care teaching hospital in Houston, TX between 1/1/99 and 12/31/00 whose gestational ages were ≥35 weeks; who had mothers with GBS positive or unknown culture status and inadequate intrapartum antibiotic prophylaxis; and who had screening CBCs performed in the first 30 hours of life because of GBS risk were reviewed (n = 412). Demographic information, maternal GBS risk factors, CBC results, clinical decisions, and rationales for clinical decisions were collected. ^ Results. With the exception of black ethnicity (p = .0000, odds ratio = 0.213), no statistically significant differences in risk factors between infants with normal and abnormal WBC counts or normal and abnormal I:T ratios were found. Infants with abnormal WBCs had a significantly higher likelihood of having a CBC repeated (p = 0.002 for WBC). Providers documented the CBC result in the rationale for clinical decisions in 62% of the cases. ^ Conclusion. The CBC results were not related to maternal risk factors for GBS except for ethnicity. Black infants had significantly lower WBC levels than infants of other ethnicities, although this difference was clinically insignificant. Infants with abnormal WBCs had a significantly higher likelihood of undergoing repeat CBCs but not sepsis evaluations. Provider rationale was difficult to evaluate due to insufficient documentation. The screening CBC result did not impact the clinicians' decisions to initiate sepsis evaluations in this population. ^
Resumo:
Transglutaminases are a family of enzymes that catalyze the covalent cross-linking of proteins through the formation of $\varepsilon$-($\gamma$-glutaminyl)-lysyl isopeptide bonds. Tissue transglutaminase (Tgase) is an intracellular enzyme which is expressed in terminally differentiated and senescent cells and also in cells undergoing apoptotic cell death. To characterize this enzyme and examine its relationship with other members of the transglutaminase family, cDNAs, the first two exons of the gene and 2 kb of the 5$\sp\prime$ flanking region, including the promoter, were isolated. The full length Tgase transcript consists of 66 bp of 5$\sp\prime$-UTR (untranslated) sequence, an open reading frame which encodes 686 amino acids and 1400 bp of 3$\sp\prime$-UTR sequence. Alignment of the deduced Tgase protein sequence with that of other transglutaminases revealed regions of strong homology, particularly in the active site region.^ The Tgase cDNA was used to isolate and characterize a genomic clone encompassing the 5$\sp\prime$ end of the mouse Tgase gene. The transcription start site was defined using genomic and cDNA clones coupled with S1 protection analysis and anchored PCR. This clone includes 2.3 kb upstream of the transcription start site and two exons that contain the first 256 nucleotides of the mouse Tgase cDNA sequence. The exon intron boundaries have been mapped and compared with the exon intron boundaries of three members of the transglutaminase family: human factor XIIIa, the human keratinocyte transglutaminase and human erythrocyte band 4.1. Tissue Tgase exon II is similar to comparable exons of these genes. However, exon I bears no resemblance with any of the other transglutaminase amino terminus exons.^ Previous work in our laboratory has shown that the transcription of the Tgase gene is directly controlled by retinoic acid and retinoic acid receptors. To identify the region of the Tgase gene responsible for regulating its expression, fragments of the Tgase promoter and 5$\sp\prime$-flanking region were cloned into the chloramphenicol actetyl transferase (CAT) reporter constructs. Transient transfection experiments with these constructs demonstrated that the upstream region of Tgase is a functional promoter which contains a retinoid response element within a 1573 nucleotide region spanning nucleotides $-$252 to $-$1825. ^