900 resultados para Difference method for differences
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effect of application methods and dentin hydration on the bond strength of three self-etching adhesives (SEA) were evaluated; 195 extracted bovine incisors were used. The buccal surface was ground in order to expose the dentin, which remained 2-mm minimum thickness, measured by a thickness meter through an opening on the lingual surface. Adper Single Bond 2 (TM) was used for the control group. The SEA were applied following two modes of application: passive or active and two hydration states of the dentin surface-dry and wet. After light-curing, composite buildups were made using Grandio (TM) composite. The specimens were sectioned and tested with a microtensile bond strength test. The application method and the hydration state resulted in statistical differences (p = 0.000) making the values of active application for mu TBS to dentin higher than passive application. The wet surfaces showed higher mu TBS to dentin ratios than dry surfaces. There were no statistical differences in mu TBS among the SEA tested but there were differences regarding to control group.
Resumo:
Purpose: To evaluate the effect of surface hydration state and application method on the microtensile bond strength of one-step self-etching adhesives systems to cut enamel.Materials and Methods: One hundred ninety-five bovine teeth were used. The enamel on the buccal side was flattened with 600-grit SiC paper. For the control group, 15 teeth received Adper Single Bond 2, applied according to manufacturer's recommendations. The other specimens were divided into three groups according to the adhesive system used: Futura Bond M (FM; Voco), Clearfil S-3 Bond (CS; Kuraray), and Optibond All in One (OA; Kerr). For each group, two hydration states were tested: D: blown dry with air; W: the excess of water was removed with absorbent paper. Two application methods were tested: P (passive): the adhesive was simply left on the surface; A (active): the adhesive was rubbed with an applicator point. A coat of Grandio composite resin (Voco) was applied on the surface. The teeth were sectioned to obtain enamel-resin sticks (1 x 1 mm), which underwent microtensile bond testing. The data in MPa were submitted to a three-way ANOVA and Tukey's test (alpha = 5%).Results: The ANOVA showed significant differences for application method and the type of adhesive, but not for hydration state. For the application method, the results of Tukey's test were: P: 31.46 (+/-7.09)a; A: 34.04 (+/-7.19)b. For the type of adhesive, the results were: OA: 31.29 (+/-7.05)a; CS: 32.28 (+/-7.14)a; FM: 34.68 (+/-7.17)b; different lower-case letters indicate statistically significant differences.Conclusion: Active application improved the bond strength to cut enamel. The adhesive Futurabond M showed the highest bond strength to cut enamel.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Influence of particle size on the properties of Pt-Ru/C catalysts prepared by a microemulsion method
Resumo:
Pt-Ru/C nanocatalysts were prepared by a microemulsion method using different values of water/surfactant molar ratio in order to get different particle sizes. Crystallite sizes and structural properties were determined by X-ray diffraction. Particle size and distribution were characterized by transmission electron microscopy and average composition was determined by energy-dispersive X-ray analysis. Thermogravimetric analysis was used to estimate the amount of supported metals. Differential scanning calorimetry measurements indicated the presence of hydrous ruthenium oxides in the as-prepared catalysts. Results for the oxidation of adsorbed CO as well as for methanol oxidation revealed significant differences in the behavior of the prepared catalysts. All together, the results demonstrate that the variation of particle size produces changes in other properties of the Pt-Ru/C catalysts and that to establish direct correlations between electrocatalytic activity and particle size is not possible because the effects of the different parameters cannot be separated. (c) 2007 the Electrochemical Society.
Resumo:
INTRODUÇÃO: A utilização correta de um plasma-controle para a comparação com o plasma do paciente nos testes de coagulação é fundamental para a garantia de um resultado seguro dessas provas laboratoriais. OBJETIVO: O presente estudo analisou a viabilidade do uso de um pool de plasma caseiro, realizado com cinco (P5) e 20 (P20) amostras a partir de pacientes normais, para ser utilizado como controle normal do tempo de tromboplastina parcial (TTP). MATERIAL E MÉTODO: Os dois pools de plasma caseiro foram analisados em relação a um controle normal comercial (AP). Foram 10 dias de experimento e a cada dia os dois pools caseiro eram feitos. Para cada dia foi feito o TTP de P5, P20 e AP. Todos os pacientes com solicitação de TTP, em cada dia do experimento, tiveram a relação de tempos (R) determinada frente a P5, P20 e AP. As ferramentas estatísticas utilizadas foram média (X), análise de variância e teste de Tukey. RESULTADOS: A análise estatística demonstrou que os valores de TTP são significativamente diferentes entre AP e P5 e entre AP e P20, mas não há diferença significativa entre P5 e P20. Quando a relação de tempos foi analisada, não houve diferença significativa entre AP, P5 e P20. CONCLUSÃO: O estudo demonstrou que pode ser utilizado como controle normal um pool de plasma caseiro, feito a partir de cinco ou 20 amostras.
Resumo:
A dispersão da amostra de solo é uma etapa fundamental da análise granulométrica, sendo realizada mediante o uso de dispersantes químicos e agitação mecânica. O objetivo deste trabalho foi avaliar a eficiência de mesa agitadora reciprocante de baixa rotação na dispersão mecânica de amostras de solos de diferentes classes texturais. Foram realizadas análises granulométricas em 61 amostras com quatro repetições, empregando o método da pipeta para determinação da fração argila e tamisagem para determinação das frações areia grossa, areia fina e areia total, sendo o silte determinado por diferença. Na avaliação de desempenho, os resultados obtidos com uso da mesa agitadora reciprocante (MAR) foram comparados com dados disponíveis para as mesmas amostras oriundos de relatórios do Ensaio de Proficiência IAC para Laboratórios de Análises de Solos - Prolab/IAC. Análises de acurácia foram realizadas com base nos valores dos intervalos de confiança definidos para cada fração granulométrica componente de cada amostra ensaiada. Indicadores gráficos também foram utilizados na comparação de dados, por meio de dispersão e ajuste linear. A estatística descritiva indicou preponderância de baixa variabilidade em mais de 90 % dos resultados obtidos para as amostras de texturas arenosa, média e argilosa e em 68 % dos obtidos para as amostras de textura muito argilosa, indicando boa repetibilidade dos resultados obtidos com a MAR. Média variabilidade foi mais frequentemente associada à fração silte, seguida da fração areia fina. Os resultados das análises de sensibilidade indicam acurácia de 100 % nas três frações granulométricas - areia total, silte e argila - para todas as amostras analisadas pertencentes às classes texturais muito argilosa, argilosa e média. Para as nove amostras de textura arenosa, a acurácia média foi de 85,2 %, e os maiores desvios ocorreram em relação à fração silte. Nas aproximações lineares, coeficientes de correlação igual (silte) ou superiores (areia total e argila) a 0,93, bem como diferenças menores do que 0,16 entre os coeficientes angulares das retas e o valor unitário, indicam alta correlação entre os resultados de referência (Prolab/IAC) e os obtidos nos ensaios com a MAR. Conclui-se pelo desempenho satisfatório da mesa agitadora reciprocante de baixa rotação para dispersão mecânica de amostras de solo de diferentes classes texturais para fins de análise granulométrica, permitindo recomendar o uso alternativo do equipamento quando se emprega agitação lenta. As vantagens do uso do equipamento nacional incluem o baixo custo, a possibilidade de análise simultânea de grande número de amostras e o uso de frascos comuns, de vidro ou de plástico, baratos e de fácil reposição.
Neuroethologic differences in sleep deprivation induced by the single- and multiple-platform methods
Resumo:
It has been proposed that the multiple-platform method (MP) for desynchronized sleep (DS) deprivation eliminates the stress induced by social isolation and by the restriction of locomotion in the single-platform (SP) method. MP, however, induces a higher increase in plasma corticosterone and ACTH levels than SP. Since deprivation is of heuristic value to identify the functional role of this state of sleep, the objective of the present study was to determine the behavioral differences exhibited by rats during sleep deprivation induced by these two methods. All behavioral patterns exhibited by a group of 7 albino male Wistar rats submitted to 4 days of sleep deprivation by the MP method (15 platforms, spaced 150 mm apart) and by 7 other rats submitted to sleep deprivation by the SP method were recorded in order to elaborate an ethogram. The behavioral patterns were quantitated in 10 replications by naive observers using other groups of 7 rats each submitted to the same deprivation schedule. Each quantification session lasted 35 min and the behavioral patterns presented by each rat over a period of 5 min were counted. The results obtained were: a) rats submitted to the MP method changed platforms at a mean rate of 2.62 ± 1.17 platforms h-1 animal-1; b) the number of episodes of noninteractive waking patterns for the MP animals was significantly higher than that for SP animals (1077 vs 768); c) additional episodes of waking patterns (26.9 ± 18.9 episodes/session) were promoted by social interaction in MP animals; d) the cumulative number of sleep episodes observed in the MP test (311) was significantly lower (chi-square test, 1 d.f., P<0.05) than that observed in the SP test (534); e) rats submitted to the MP test did not show the well-known increase in ambulatory activity observed after the end of the SP test; f) comparison of 6 MP and 6 SP rats showed a significantly shorter latency to the onset of DS in MP rats (7.8 ± 4.3 and 29.0 ± 25.0 min, respectively; Student t-test, P<0.05). We conclude that the social interaction occurring in the MP test generates additional stress since it increases the time of forced wakefulness and reduces the time of rest promoted by synchronized sleep.
Resumo:
JUSTIFICATIVA E OBJETIVOS: A manutenção de concentração sangüínea alvo-controlada em níveis aproximadamente constantes do propofol é uma técnica que pode ser empregada de modo simplificado na sala de cirurgia. A finalidade desta pesquisa é comparar clínica e laboratorialmente a infusão de propofol em crianças usando os atributos farmacocinéticos de Short e de Marsh. MÉTODO: Foram estudados 41 pacientes com a idade de 4 a 12 anos, de ambos os sexos, estado físico ASA I ou II, distribuídos em dois grupos S (20 pacientes) e M (21 pacientes). No Grupo S utilizaram-se os atributos farmacocinéticos de Short, e no Grupo M, os atributos farmacocinéticos de Marsh. A indução anestésica foi feita com bolus de alfentanil 30 µg.kg-1, propofol 3 mg.kg-1 e pancurônio, 0,08 mg.kg-1 por via venosa. Procedeu-se a intubação traqueal e a manutenção com N2O/O2 (60%) em ventilação controlada mecânica. No grupo S a infusão de propofol foi de 254 (30 min) seguido de 216 µg.kg-1.min-1 por mais 30 min. No grupo M a infusão de propofol foi de 208 (30 min) seguido de 170 µg.kg-1.min-1 por mais 30 min. Através do atributo farmacocinético específico a cada grupo a meta foi a obtenção da concentração-alvo de 4 µg.kg-1 de propofol. Foram colhidas três amostras sangüíneas (aos 20, 40 e 60 minutos) para a dosagem do propofol pelo método da Cromatografia Líquida de Alta Performance. RESULTADOS: Os Grupos S e M foram considerados similares quanto à idade, altura, peso e sexo (p > 0,05). Não houve diferença estatística significativa entre os dois grupos estudados para os parâmetros: PAS, PAD, FC, FiN2O, SpO2 da hemoglobina e P ET CO2 no final da expiração. A comparação entre grupos no número de bolus repetidos de alfentanil não foi estatisticamente significativa. O índice bispectral (BIS) não apresentou diferença estatisticamente significativa entre M0 (vigília) e os demais momentos em ambos os grupos. Os valores Medianos da Performance do Erro (MPE) e os valores Medianos Absolutos da Performance do Erro (MAPE) mostraram diferenças estatísticas significativas entre os grupos no momento 60. Valores medianos da concentração sangüínea de propofol (µg.kg-1) mostraram diferenças estatísticas significativas entre M e S no momento 60 e entre os momentos 40 e 60 no grupo S. CONCLUSÕES: A anestesia com propofol usando os atributos farmacocinéticos de Marsh (Grupo M) apresentou menor erro no cálculo da concentração-alvo de propofol de 4 µg.kg-1. Além disso, utiliza menor quantidade de propofol para obter resultados clínicos semelhantes. Por todas essas qualidades deve ser a preferida para uso em crianças ASA I e com idades entre 4 e 12 anos.
Resumo:
OBJETIVO: Quantificar a dor em cães sob anestesia dissociativa através de estímulo térmico e pressórico e o período hábil de dois analgésicos opióides. MÉTODOS: Empregaram-se 30 cães alocados em três grupos (n=10), onde os animais de GI receberam levomepromazina e midazolam associado na mesma seringa à quetamina. Os animais de GII receberam o mesmo tratamento de GI porém associado ao butorfanol e por fim os animais de GIII receberam o mesmo tratamento de GI associando-se a buprenorfina. Procedeu se a avaliação paramétrica rotineira, empregando-se, entretanto, a termoalgimetria mensurada em °C em média de 52°C e a pressoalgimetria em kg. RESULTADOS: Na termoalgimetria houve diferença significativa em GI nos momentos M0 e M1,e em M4 e M5. em GII houve diferença em M0, M1, M5 e M6. em GIII houve diferença entre momentos M0 e M1. Na pressoalgimetria houveram diferenças em GI em diferentes momentos: M0, M2 e M3. em GII observaram-se diferenças em todos os momentos. em GIII observaram-se diferenças em M0 e M9. Ocorreram diferenças entre os grupos, sendo o M2 de GII menor que GI e GIII. Já em M4 e M5 de GIII demonstrou-se maior que GI e GII. E na avaliação dos períodos observou-se um período de latência significativamente maior em GI, porém com período hábil e de recuperação menor em relação à GII e GIII. Já a recuperação do tônus postural foi maior em GIII seguido de GII e finalmente de GI. CONCLUSÃO: O método empregado para mensuração do estímulo álgico foi eficiente, observando-se um período hábil analgésico de 3 horas para o butorfanol e de 6 horas para a buprenorfina.
Resumo:
RESUMO - O objetivo deste trabalho foi comparar o sistema de monitoramento computadorizado da produção de gás in vitro com os métodos in vivo e in situ. Nas comparações, foram utilizadas silagens de milho com alto/baixo teores de matéria seca, com/sem inoculante. A digestibilidade das silagens com alto teor de matéria seca (MS), com/sem inoculação, não apresentou diferenças entre os métodos analisados. Quando avaliadas separadamente do efeito do inóculo, essas silagens diferiram nos métodos in vitro/gás e in situ, mas não no in vivo. Entretanto, quando analisadas somente sob efeito do inoculante, apenas no método in situ houve diferença. Não foram encontradas diferenças na digestibilidade da fibra em detergente neutro (FDN) das silagens com alta ou baixa MS, inoculadas ou não, bem como em relação ao pH ao final da digestão. em conclusão, o desaparecimento da MS e FDN quantificada pelo resíduo no sistema in vitro/gás foi semelhante aos demais métodos avaliados.
Resumo:
Objetivou-se com este estudo a identificação de alguns fatores protéicos envolvidos na qualidade funcional dos espermatozóides epididimais (SPZEP) e ejaculados (SPZEJ) de bovinos. Foram avaliadas as características morfofisiológicas e analisado o conteúdo peptídico destas estruturas de 11 animais mestiços Nelore, de 24 a 30 meses de idade. As avaliações morfofisiológicas foram motilidade progressiva (MOT, %), vigor, patologias espermáticas, integridade acrossômica e da cromatina. Foi observado que, os SPZEJ, na média, apresentaram MOT maior do que os SPZEP, 72,3 e 46,4%, respectivamente. Considerando as patologias espermáticas, taxas de defeitos maiores (DEFMAI), menores (DEFMEN) e totais (DEFTOT), houve diferença significativa entre as taxas dos DEFMEN e DEFTOT dos SPZEP e SPZEJ, sendo, em média, 91,1 e 8,5% e 95,4 e 11,8%, respectivamente. As taxas dos DEFMEN e DEFTOT dos SPZEP foram maiores em função da presença de espermatozóides com gotas citoplasmáticas distais. A análise das protéinas dos SPZEP e SPZEJ foi realizada por espectrometria de massa, método MALDI-TOF (matrix -assisted laser desorption/ionization - time of flight), e revelou presença de peptídeos de massa molecular variando de 1,1 a 26,3 kDa nos SPZEJ e de 1,1 a 11,6 kDa nos SPZEP. Foram identificados peptídeos de 10,6 e 13,4 kDa somente nos SPZEJ e de 6,8 kDa somente nos SPZEP. Foi observada relação do peptídeo de massa molecular de 7,4 kDa dos SPZEP e de 4,7 kDa dos SPZEJ, com a MOT Ê 80%, destas estruturas. Os resultados sugerem o envolvimento destes peptídeos nos processos funcionais das células espermáticas do epidídimo e ejaculado. O estudo utilizou o método MALDI/TOF para espectrômetro de massa, para identificar peptídeos em espermatozóides do epidídimo de bovinos, pela primeira vez no País.
Resumo:
The analgesic response was evaluated by the tail immersion test in adult male (N = 30), female (N = 21) and androgenized female Wistar rats (N = 15). The reaction time for tail withdrawal from the hot water bath was faster for male than for female rats (3.48 +/- 0.12 vs 6.46 +/- 0.42 s). The reaction time of androgenized female rats was similar to that of male rats (3.08 +/- 0.16 s). Blockade of opiate receptors with naloxone (2 mg/kg, ip) decreased the sensitivity to the noxious stimuli in males (4.08 +/- 0.10 s) and in androgenized females (3.69 +/- 0.19 s) but increased it in female rats (5.01 +/- 0.41 s). These data show sex-related differences in the analgesic response evaluated by the tail immersion test and indicate that administration of androgens to newborn female rats affects their pain sensitivity.
Resumo:
The glycoprotein gp43 from Paracoccidioides brasiliensis is the main antigenic component in paracoccidioidomycosis (PCM) because it is recognized by 100% of PCM patients. It has also been shown that different fungal strains produce gp43 with at least four isoform profiles. In this study, different isoform profiles from gp43, with pIs ranging from 5.8 to 8.5, were affinity purified from various P. brasiliensis (B-339, S.S., 1925 and I-9) exoantigens. Because of the isoform heterogeneity, we questioned whether those isoform profiles could be similarly recognized by acute or chronic PCM patients. By using a specific and sensitive method for detection of human IgG anti-gp43 antibodies, the monoclonal antibody capture immunoassay, we report that not all gp43 isoform profiles are equally recognized in PCM sera when anti-gp43 MAb 17c was employed as capturing antibody. Our result showed that recognition of pI 8.5 gp43 isoform was significantly lower for both acute (56%) and chronic patients (71%), compared with gp43 isoforms from the standard strain B-339. on the other hand, when anti-gp43 MAb 8a, which recognizes a different antigenic epitope was used to capture the different gp43 isoform profiles, all patient's sera reacted similarly. The results described suggest that not all the antigenic epitopes expressed by gp43 are equally present in all P. brasiliensis strains.
Resumo:
Sticholysins I and II (St I and St II) are cytolysins produced by the sea anemone Stichodactyla helianthus. In spite of their 93% sequence homology, St II is more hemolytic against human erythrocytes than St 1. In order to establish the possible causes of this difference, we studied the hemolytic activity of synthetic peptides containing sequences from the N-termini of both proteins. The results demonstrated that the differences in hemolytic activity of the toxins could be ascribed at least partly to differences in their N-termini. (c) 2007 Elsevier Ltd. All rights reserved.