959 resultados para Diagnostic Test Accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this in vitro study was to assess the influence of varying examiner's clinical experience on the reproducibility and accuracy of radiographic examination for occlusal caries detection. Standardized bitewing radiographs were obtained from 166 permanent molars. Radiographic examination was performed by final-year dental students from two universities (A, n=5; B, n=5) and by dentists with 5 to 7 years of experience who work in two different countries (C, n=5; D, n=5). All examinations were repeated after 1-week interval. The teeth were histologically prepared and assessed for caries extension. For intraexaminer reproducibility, the unweighted kappa values were: A (0.11-0.40), B (0.12-0.33), C (0.47-0.58), and D (0.42-0.71). Interexaminer reproducibility statistics were computed based on means +/- SD of unweighted kappa values: A (0.07 +/- 0.05), B (0.12 +/- 0.09), C (0.24 +/- 0.08), and D (0.33 +/- 0.10). Sensitivity, specificity, and accuracy were calculated at D(1) and D(3) thresholds and compared by performing McNemar test (p=0.05). D(1) sensitivity ranged between 0.29 and 0.75 and specificity between 0.24 and 0.85. D(3) specificity was moderate to high (between 0.62 and 0.95) for all groups, with statistically significant difference between the dentists groups (C and D). Sensitivity was low to moderate (between 0.21 and 0.57) with statistically significant difference for groups B and D. Accuracy was similar for all groups (0.55). Spearman's correlations were: A (0.12), B (0.24), C (0.30), and D (0.38). In conclusion, the reproducibility of radiographic examination was influenced by the examiner's clinical experience, training, and dental education as well as the accuracy in detecting occlusal caries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução: O exame colpocitológico ou teste de Papanicolaou permite o diagnóstico precoce do câncer de colo do útero. O êxito no rastreamento desta doença dependerá, além de outros fatores, da acuidade diagnóstica do exame colpocitológico. Objetivos: Avaliar a acurácia diagnóstica da citologia cervicovaginal na detecção de lesões cervicais através da comparação citoistopatológica. Material e métodos: Avaliou-se o grau de concordância entre os exames citológico e histopatológico de 373 pacientes atendidas em um hospital universitário no período de 1990 a 1997 e foram calculados os indicadores: sensibilidade, especificidade, valores preditivos positivos e negativos e as taxas de falsos positivos e falsos negativos do exame. Resultados: A taxa bruta de concordância citoistopatológica foi de 65,1%. A sensibilidade do exame foi alta (96,0%), no entanto sua especificidade foi baixa (51,5%), significando a inclusão de muitos resultados falsos positivos. A taxa de falsos positivos foi de 48,4%, enquanto a de falsos negativos foi de 4%. Discussão: Apesar de a sensibilidade do teste ser alta, sua especificidade é baixa, significando que muitas mulheres seriam falsamente diagnosticadas como doentes, levando a um número elevado de resultados falsos positivos e custos desnecessários, além do potencial caráter iatrogênico que esta ação poderia assumir. No entanto, um exame altamente sensível é o teste de escolha para programas de rastreamento de câncer cervical na população feminina. Conclusões: Para garantir a acuidade diagnóstica do teste de Papanicolaou são essenciais atividades de controle de qualidade nos laboratórios, tanto do procedimento colpocitológico quanto do histopatológico, permitindo, assim, o êxito na detecção precoce e no tratamento das lesões cervicais.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Processing efficiency theory predicts that anxiety reduces the processing capacity of working memory and has detrimental effects on performance. When tasks place little demand on working memory, the negative effects of anxiety can be avoided by increasing effort. Although performance efficiency decreases, there is no change in performance effectiveness. When tasks impose a heavy demand on working memory, however, anxiety leads to decrements in efficiency and effectiveness. These presumptions were tested using a modified table tennis task that placed low (LWM) and high (HWM) demands on working memory. Cognitive anxiety was manipulated through a competitive ranking structure and prize money. Participants' accuracy in hitting concentric circle targets in predetermined sequences was taken as a measure of performance effectiveness, while probe reaction time (PRT), perceived mental effort (RSME), visual search data, and arm kinematics were recorded as measures of efficiency. Anxiety had a negative effect on performance effectiveness in both LWM and HWM tasks. There was an increase in frequency of gaze and in PRT and RSME values in both tasks under high vs. low anxiety conditions, implying decrements in performance efficiency. However, participants spent more time tracking the ball in the HWM task and employed a shorter tau margin when anxious. Although anxiety impaired performance effectiveness and efficiency, decrements in efficiency were more pronounced in the HWM task than in the LWM task, providing support for processing efficiency theory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Injection metering systems are an important option for the development of pesticide application equipment, with advantages relating to minimising the need for disposal of unused pesticide, improving the ease of cleaning and optimising the accuracy of chemical application. For all injection systems, characteristics such as the steady-state accuracy of delivered dose, dose stability and the time response for dose step changes are related to the ability of the system to operate with different chemical formulations. A system designed to inject liquids should be able to accommodate changes in viscosity and density. The aim of this study was to develop a methodology for testing chemical injection systems using liquids with different viscosities. The experimental arrangement simulating applications with injection metering systems used dye and salt solutions as tracers. Tests were conducted to analyse the influence of salt on the characteristics of the water and a viscous solution. Results showed that the salt interfered with the dye stability in the water solution. In tests with a viscous test liquid, the salt was introduced at different steps during the mixing process, providing four different liquids to be analysed in terms of viscosity, density and pH. Some differences in liquid characteristics were found which could influence the performance of the injection systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The buffaloes dairy milk production (BDMP) has increased in the last 20 years, mainly for the manufacturing of mozzarella cheese, which is recognized by its high nutritional quality. However, this quality can be affected by several factors i. e. high somatic cells count (SCC) provokes changes in the milk's constituents. As in bovine dairy milk, the SCC is used as diagnostic tool for milk quality; because it enables the diagnosis of sub-clinic mastitis and also allows the selection of individuals genetically resistant to that disease. Based on it, we collected information about SCC and BDMP along the lactation in Murrah breed buffaloes, during the period between 1997 and 2005. Curves were designed to estimate genetic parameters. These parameters were estimated by ordinary test-day models. There were observed variations in the estimated heritability for both characteristics the lowest score for somatic cells count (SSCC) was seen at first month (0.01) and the highest at sixth months (0.29 the genetic correlation between these traits varied from -1 at the 1 and 9(th) months to 0.31 and 0.30 in the2 and 4(th) month of lactation. Phenotypic correlations were all negative (-0.07 in the second month and up to -0.35 in the eighth month of lactation). These results showed that environmental factors are more important than genetics in explain SCC, for this reason, selection for genetic resistance to mastitis in buffalos based in SCC should not be done. In the other hand, negative phenotypic correlations demonstrated that as the SCC increased, the milk production decreased.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A liquid phase blocking ELISA (LPB-ELISA) was adapted for the detection and quantification of antibodies to Newcastle disease virus. Sera from vaccinated and unvaccinated commercial flocks of ostriches (Struthio camelus) and rheas (Rhea americana) were tested. The purified and nonpurified virus used as the antigen and the capture and detector antibodies were prepared and standardized for this purpose. The hemagglutination-inhibition (HI) test was regarded as the reference method, the cutoff point for the LPB-ELISA was determined by a two-graph receiver operating characteristic analysis. The LPB-ELISA titers regressed significantly (P < 0.0001) on the HI titers with a high correlation coefficient (r = 0.875). The two tests showed good agreement ( = 0.82; P < 0.0001), relative sensitivity (90.91%) and specificity (91.18%), and accuracy (91.02%), suggesting that they are interchangeable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two rapid tests evaluated in dogs considered to be of high risk of Infection with the Chagas parasite Trypanosoma cruzi using two immunochromatographic assays. Trypanosoma Detect (TM) for canine, InBios, Seattle, WA and CHAGAS STAT-PAK (TM) assay, Chembio Diagnostic Systems, Medford, NY, in south central Louisiana. For this purpose a serological survey was carried out in a total of 122 dogs and a serum bank was created. These 122 animals were first tested by IFAT that was used as the standard test From the serum bank 50 samples were tested using the two rapid Chagas assays and results compared to the standard test IFAT The serological survey using IFAT showed it prevalence of T cruzi infection in 22.1% of the tested dogs. In the immunochromatographic assays. 13 and 11 animals were positive on rapid assay Trypanosoma Detect (TM) for canine, InBios and CHAGAS STAT-PAK (TM), Chembio Diagnostic Systems, respectively compared to 11 positive by IFAT. These two immunochromatographic tests have shown high susceptibility and specificity compared to our standard method IFAT. The rapid, easy and accurate screening assays used in conjunction with confirmatory tests, would be an excellent tool for veterinarians to diagnose T cruzi infection. Early detection of T cruzi infection may prevent complications through an effective treatment. Greater awareness by veterinarians of the risk. clinical findings, history along with diagnostic methods will contribute greatly to an understanding of the true prevalence of Chagas disease in dogs in Louisiana. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Obstructive sleep apnea (OSA) is a respiratory disease characterized by the collapse of the extrathoracic airway and has important social implications related to accidents and cardiovascular risk. The main objective of the present study was to investigate whether the drop in expiratory flow and the volume expired in 0.2 s during the application of negative expiratory pressure (NEP) are associated with the presence and severity of OSA in a population of professional interstate bus drivers who travel medium and long distances.Methods/Design: An observational, analytic study will be carried out involving adult male subjects of an interstate bus company. Those who agree to participate will undergo a detailed patient history, physical examination involving determination of blood pressure, anthropometric data, circumference measurements (hips, waist and neck), tonsils and Mallampati index. Moreover, specific questionnaires addressing sleep apnea and excessive daytime sleepiness will be administered. Data acquisition will be completely anonymous. Following the medical examination, the participants will perform a spirometry, NEP test and standard overnight polysomnography. The NEP test is performed through the administration of negative pressure at the mouth during expiration. This is a practical test performed while awake and requires little cooperation from the subject. In the absence of expiratory flow limitation, the increase in the pressure gradient between the alveoli and open upper airway caused by NEP results in an increase in expiratory flow.Discussion: Despite the abundance of scientific evidence, OSA is still underdiagnosed in the general population. In addition, diagnostic procedures are expensive, and predictive criteria are still unsatisfactory. Because increased upper airway collapsibility is one of the main determinants of OSA, the response to the application of NEP could be a predictor of this disorder. With the enrollment of this study protocol, the expectation is to encounter predictive NEP values for different degrees of OSA in order to contribute toward an early diagnosis of this condition and reduce its impact and complications among commercial interstate bus drivers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the effectiveness of the Gram stain in the initial diagnosis of the etiologic agent of peritonitis in continuous ambulatory peritoneal dialysis (CAPD). Design: Retrospective study analyzing the sensitivity (S), specificity (SS), positive predictive value (+PV), and negative predictive value (-PV) of the Gram stain relating to the results of cultures in 149 episodes of peritonitis in CAPD. The data were analyzed in two studies. In the first, only the cases with detection of a single agent by Gram stain were taken (Study 1). In the second, only the cases with two agents in Gram stain were evaluated (Study 2). Setting: Dialysis Unit and Laboratory of Microbiology of a tertiary medical center. Patients: Sixty-three patients on regular CAPD who presented one or more episodes of peritonitis from May 1992 to May 1995. Results: The positivity of Gram stain was 93.2% and the sensitivity was 95.7%. The values of S, SS, +PV, and -PV were respectively: 94.9%, 53.5%, 68.3%, and 90.9% for gram-positive cocci and 83.3%, 98.8%, 95.2%, and 95.6% for gram-negative bacilli. The association of gram-positive cocci plus gram-negative bacilli were predictive of growth of both in 6.8%, growth of gram-positive cocci in 13.7%, and growth of gram-negative bacilli in 72.5%. Conclusions: The Gram stain is a method of great value in the initial diagnosis of the etiologic agent of peritonitis in CAPD, especially for gram-negative bacilli.