998 resultados para Control equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Segurança e Higiene do Trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a distributed model predictive control (DMPC) for indoor thermal comfort that simultaneously optimizes the consumption of a limited shared energy resource. The control objective of each subsystem is to minimize the heating/cooling energy cost while maintaining the indoor temperature and used power inside bounds. In a distributed coordinated environment, the control uses multiple dynamically decoupled agents (one for each subsystem/house) aiming to achieve satisfaction of coupling constraints. According to the hourly power demand profile, each house assigns a priority level that indicates how much is willing to bid in auction for consume the limited clean resource. This procedure allows the bidding value vary hourly and consequently, the agents order to access to the clean energy also varies. Despite of power constraints, all houses have also thermal comfort constraints that must be fulfilled. The system is simulated with several houses in a distributed environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilayered heterostructures based on embedded a-Si:H and a-SiC:H p-i-n filters are analyzed from differential voltage design perspective using short- and long-pass filters. The transfer functions characteristics are presented. A numerical simulation is presented to explain the filtering properties of the photonic devices. Several monochromatic pulsed lights, separately (input channels) or in a polychromatic mixture (multiplexed signal) at different bit rates, illuminated the device. Steady-state optical bias is superimposed from the front and the back side. Results show that depending on the wavelength of the external background and impinging side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. Particular attention is given to the amplification coefficient weights, which allow to take into account the wavelength background effects when a band or frequency needs to be filtered or the gate switch, in which optical active filter gates are used to select and filter input signals to specific output ports in wavelength division multiplexing (WDM) communication systems. This nonlinearity provides the possibility for selective removal or addition of wavelengths. A truth table of an encoder that performs 8-to-1 MUX function exemplifies the optoelectronic conversion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new driving scheme utilizing an in-pixel metal-insulator-semiconductor (MIS) photosensor for luminance control of active-matrix organic light-emitting diode (AMOLED) pixel. The proposed 3-TFT circuit is controlled by an external driver performing the signal readout, processing, and programming operations according to a luminance adjusting algorithm. To maintain the fabrication simplicity, the embedded MIS photosensor shares the same layer stack with pixel TFTs. Performance characteristics of the MIS structure with a nc-Si : H/a-Si : H bilayer absorber were measured and analyzed to prove the concept. The observed transient dark current is associated with charge trapping at the insulator-semiconductor interface that can be largely eliminated by adjusting the bias voltage during the refresh cycle. Other factors limiting the dynamic range and external quantum efficiency are also determined and verified using a small-signal model of the device. Experimental results demonstrate the feasibility of the MIS photosensor for the discussed driving scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the structural and optical properties of Co-doped TiO2 thin films grown onto (0001)Al2O3 substrates by non-reactive pulsed laser deposition (PLD) using argon as buffer gas. It is shown that by keeping constant the substrate temperature at as low as 310 degrees C and varying only the background gas pressure between 7 Pa and 70 Pa, it is possible to grow either epitaxial rutile or pure anatase thin films, as well as films with a mixture of both polymorphs. The optical band gaps of the films are red shifted in comparison with the values usually reported for undoped TiO2, which is consistent with n-type doping of the TiO2 matrix. Such band gap red shift brings the absorption edge of the Co-doped TiO2 films into the visible region, which might favour their photocatalytic activity. Furthermore, the band gap red shift depends on the films' phase composition, increasing with the increase of the Urbach energy for increasing rutile content. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Segurança e Higiene no Trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess risk factors for retreatment of leprosy patients. METHODS: A case-control study with patients from two reference care units in Recife, northeastern Brazil, in 2003. The case group included retreated patients (N=155) and the control group comprised those patients who were not retreated (N=155) matched by year of diagnosis and health care unit. Univariate and multivariate analyses were conducted to test the associations and odds ratios and related 95% confidence intervals were estimated. RESULTS: The following factors were found to be significantly associated (p<0.05) with retreatment: occurrence of adverse immunological reactions after treatment completion (OR=2.3; 95% CI=1.18;4.83), final bacterial index > 1 (OR=6.43; 95% CI=1.67;24.74), therapeutic regimen consisting of sulfone monotherapy (OR=10; 95% CI=0.01;0.78) and reports of household contacts (OR=2.2; 95% CI=0.24;0.85). CONCLUSIONS: The study findings reinforce that the use of dapsone monotherapy should be discontinued, and highlight the need for epidemiological monitoring of specific groups of leprosy patients after treatment completion through periodical clinical and laboratory evaluation. Further studies to explore the association between final bacterial index and retreatment are strongly recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The article had the purpose of commenting on studies on polypharmacy in the elderly, focusing on diagnosis and control. Polypharmacy is defined as the use of a number of medications at the same time and the use of additional drugs to correct drug adverse effects. The fact that the elderly take more medications for the treatment of several diseases makes them more susceptible to the occurrence of adverse reactions. Prophylactic actions such as balanced prescriptions are vital to reduce the incidence of these reactions and prevent longer hospital stay, increased costs and aggravation of the elderly health condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the association between dietary patterns and oral cancer. METHODS: The study, part of a Latin American multicenter hospital-based case-control study, was conducted in São Paulo, Southeastern Brazil, between November 1998 and March 2002 and included 366 incident cases of oral cancer and 469 controls, frequency-matched with cases by sex and age. Dietary data were collected using a food frequency questionnaire. The risk associated with the intake of food groups defined a posteriori, through factor analysis (called factors), was assessed. The first factor, labeled "prudent," was characterized by the intake of vegetables, fruit, cheese, and poultry. The second factor, "traditional," consisted of the intake of rice, pasta, pulses, and meat. The third factor, "snacks," was characterized as the intake of bread, butter, salami, cheese, cakes, and desserts. The fourth, "monotonous," was inversely associated with the intake of fruit, vegetables and most other food items. Factor scores for each component retained were calculated for cases and controls. After categorization of factor scores into tertiles according to the distribution of controls, odds ratios and 95% confidence intervals were calculated using unconditional multiple logistic regression. RESULTS: "Traditional" factor showed an inverse association with cancer (OR=0.51; 95% CI: 0.32; 0.81, p-value for trend 0.14), whereas "monotonous" was positively associated with the outcome (OR=1.78; 95% CI: 1.78; 2.85, p-value for trend <0.001). CONCLUSIONS: The study data suggest that the traditional Brazilian diet, consisting of rice and beans plus moderate amounts of meat, may confer protection against oral cancer, independently of any other risk factors such as alcohol intake and smoking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A calibração e o controlo da qualidade de um acelerador linear são passos muito importantes num serviço de Radioterapia, para garantir a qualidade dos tratamentos prestados. O sector da Física da Unidade de Radioterapia do Hospital Cuf Descobertas implementou um rigoroso Programa de controlo de qualidade ao equipamento produtor de radiação e aos equipamentos medidores de radiação, de acordo com o Dec-Lei 180/2002 e com os protocolos internacionais. Para tal, foram implementados procedimentos, criadas folhas de cálculo, instruções de trabalho e impressos. Foram ainda implementados testes aos equipamentos com periodicidade definida: controlo de qualidade diário e controlo de qualidade após intervenções (manutenções preventivas e correctivas). No decorrer do ano de 2005, o sector da Física colaborou activamente com toda a equipa da Radioterapia na implementação da Norma ISO 9001:2000 no serviço, contribuindo com o seu know how na implementação desta, numa área tão importante como a da garantia da qualidade dos feixes de radiação e das respectivas calibrações em dose. Numa procura de melhoria contínua da qualidade dos serviços prestados aos pacientes, decorre ainda uma auditoria externa da EQUAL-ESTRO*, intercomparação postal com dosímetros termoluminescentes. A qualidade dos feixes de energias utilizados diariamente é analisada, tanto ao nível das calibrações absolutas de cada um dos feixes de fotões e de electrões, como ao nível dos cálculos de dose obtidos com o sistema de planimetria XiO da CMS. Os resultados das duas primeiras fases da intercomparação, relativa aos dois feixes de fotões de 6 MV e 15 MV e feixes de electrões de 4 MeV, 8 MeV e 12 MeV, foram considerados pela EQUAL-ESTRO num nível óptimo (desvio máximo na dose medida em relação à dose de referência |d| ≤ 3%).