923 resultados para Caesium 137, standard deviation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Absolute magnitude (H) of an asteroid is a fundamental parameter describing the size and the apparent brightness of the body. Because of its surface shape, properties and changing illumination, the brightness changes with the geometry and is described by the phase function governed by the slope parameter (G). Although many years have been spent on detailed observations of individual asteroids to provide H and G, vast majority of minor planets have H based on assumed G and due to the input photometry from multiple sources the errors of these values are unknown. We compute H of ~ 180 000 and G of few thousands asteroids observed with the Pan-STARRS PS1 telescope in well defined photometric systems. The mean photometric error is 0.04 mag. Because on average there are only 7 detections per asteroid in our sample, we employed a Monte Carlo (MC) technique to generate clones simulating all possible rotation periods, amplitudes and colors of detected asteroids. Known asteroid colors were taken from the SDSS database. We used debiased spin and amplitude distributions dependent on size, spectral class distributions of asteroids dependent on semi-major axis and starting values of G from previous works. H and G (G12 respectively) were derived by phase functions by Bowell et al. (1989) and Muinonen et al. (2010). We confirmed that there is a positive systematic offset between H based on PS1 asteroids and Minor Planet Center database up to -0.3 mag peaking at 14. Similar offset was first mentioned in the analysis of SDSS asteroids and was believed to be solved by weighting and normalizing magnitudes by observatory codes. MC shows that there is only a negligible difference between Bowell's and Muinonen's solution of H. However, Muinonen's phase function provides smaller errors on H. We also derived G and G12 for thousands of asteroids. For known spectral classes, slope parameters agree with the previous work in general, however, the standard deviation of G in our sample is twice as larger, most likely due to sparse phase curve sampling. In the near future we plan to complete the H and G determination for all PS1 asteroids (500,000) and publish H and G values online. This work was supported by NASA grant No. NNX12AR65G.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The impact of bronchiectasis on sedentary behaviour and physical activity is unknown. It is important to explore this to identify the need for physical activity interventions and how to tailor interventions to this patient population. We aimed to explore the patterns and correlates of sedentary behaviour and physical activity in bronchiectasis.

METHODS: Physical activity was assessed in 63 patients with bronchiectasis using an ActiGraph GT3X+ accelerometer over seven days. Patients completed: questionnaires on health-related quality-of-life and attitudes to physical activity (questions based on an adaption of the transtheoretical model (TTM) of behaviour change); spirometry; and the modified shuttle test (MST). Multiple linear regression analysis using forward selection based on likelihood ratio statistics explored the correlates of sedentary behaviour and physical activity dimensions. Between-group analysis using independent sample t-tests were used to explore differences for selected variables.

RESULTS: Fifty-five patients had complete datasets. Average daily time, mean(standard deviation) spent in sedentary behaviour was 634(77)mins, light-lifestyle physical activity was 207(63)mins and moderate-vigorous physical activity (MVPA) was 25(20)mins. Only 11% of patients met recommended guidelines. Forced expiratory volume in one-second percentage predicted (FEV1% predicted) and disease severity were not correlates of sedentary behaviour or physical activity. For sedentary behaviour, decisional balance 'pros' score was the only correlate. Performance on the MST was the strongest correlate of physical activity. In addition to the MST, there were other important correlate variables for MVPA accumulated in ≥10-minute bouts (QOL-B Social Functioning) and for activity energy expenditure (Body Mass Index and QOL-B Respiratory Symptoms).

CONCLUSIONS: Patients with bronchiectasis demonstrated a largely inactive lifestyle and few met the recommended physical activity guidelines. Exercise capacity was the strongest correlate of physical activity, and dimensions of the QOL-B were also important. FEV1% predicted and disease severity were not correlates of sedentary behaviour or physical activity. The inclusion of a range of physical activity dimensions could facilitate in-depth exploration of patterns of physical activity. This study demonstrates the need for interventions targeted at reducing sedentary behaviour and increasing physical activity, and provides information to tailor interventions to the bronchiectasis population.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: In this cohort study, we explored the relationship between fluid balance, intradialytic hypotension and outcomes in critically ill patients with acute kidney injury (AKI) who received renal replacement therapy (RRT).

Methods: We analysed prospectively collected registry data on patients older than 16 years who received RRT for at least two days in an intensive care unit at two university-affiliated hospitals. We used multivariable logistic regression to determine the relationship between mean daily fluid balance and intradialytic hypotension, both over seven days following RRT initiation, and the outcomes of hospital mortality and RRT dependence in survivors.

Results: In total, 492 patients were included (299 male (60.8%), mean (standard deviation (SD)) age 62.9 (16.3) years); 251 (51.0%) died in hospital. Independent risk factors for mortality were mean daily fluid balance (odds ratio (OR) 1.36 per 1000 mL positive (95% confidence interval (CI) 1.18 to 1.57), intradialytic hypotension (OR 1.14 per 10% increase in days with intradialytic hypotension (95% CI 1.06 to 1.23)), age (OR 1.15 per five-year increase (95% CI 1.07 to 1.25)), maximum sequential organ failure assessment score on days 1 to 7 (OR 1.21 (95% CI 1.13 to 1.29)), and Charlson comorbidity index (OR 1.28 (95% CI 1.14 to 1.44)); higher baseline creatinine (OR 0.98 per 10 mu mol/L (95% CI 0.97 to 0.996)) was associated with lower risk of death. Of 241 hospital survivors, 61 (25.3%) were RRT dependent at discharge. The only independent risk factor for RRT dependence was pre-existing heart failure (OR 3.13 (95% CI 1.46 to 6.74)). Neither mean daily fluid balance nor intradialytic hypotension was associated with RRT dependence in survivors. Associations between these exposures and mortality were similar in sensitivity analyses accounting for immortal time bias and dichotomising mean daily fluid balance as positive or negative. In the subgroup of patients with data on pre-RRT fluid balance, fluid overload at RRT initiation did not modify the association of mean daily fluid balance with mortality.

Conclusions: In this cohort of patients with AKI requiring RRT, a more positive mean daily fluid balance and intradialytic hypotension were associated with hospital mortality but not with RRT dependence at hospital discharge in survivors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many AMS systems can measure 14C, 13C and 12C simultaneously thus providing δ13C values which can be used for fractionation normalization without the need for offline 13C /12C measurements on isotope ratio mass spectrometers (IRMS). However AMS δ13C values on our 0.5MV NEC Compact Accelerator often differ from IRMS values on the same material by 4-5‰ or more. It has been postulated that the AMS δ13C values account for the potential graphitization and machine induced fractionation, in addition to natural fractionation, but how much does this affect the 14C ages or F14C? We present an analysis of F14C as a linear least squares fit with AMS δ13C results for several of our secondary standards. While there are samples for which there is an obvious correlation between AMS δ13C and F14C, as quantified with the calculated probability of no correlation, we find that the trend lies within one standard deviation of the variance on our F14C measurements. Our laboratory produces both zinc and hydrogen reduced graphite, and we present our results for each type. Additionally, we show the variance on our AMS δ13C measurements of our secondary standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Catalytic oxidation reaction monitoring has been performed for the first time with a trace gas carbon dioxide analyser based on a continuous wave (cw), thermoelectrically cooled (TEC), distributed feedback (DFB) quantum cascade laser (QCL) operating at around 2307 cm-1. The reaction kinetics for carbon monoxide oxidation over a platinum catalyst supported on yttria-stabilised zirconia were followed by the QCL CO2 analyser and showed that it is a powerful new tool for measuring low reaction rates associated with low surface area model catalysts operating at atmospheric pressures. A detection limit was determined of 40 ppb (1 standard deviation) for a 0.1 s average and a residual absorption standard deviation of 1.9×10-4. © 2012 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pilot study to investigate the effects of mathematics peer tutoring in Irish medium primary schools was undertaken. Five schools and 90 students took part in the pilot. Materials and resources that had previously been shown to work in English medium Scottish schools were translated into Irish by CCEA. Irish medium teachers attended three professional development days. Teachers implemented the peer tutoring techniques during mathematics lessons during a period of 16 weeks. Changes in attainment were measures with an Irish translation of the Scottish Survey of Achievement Mathematics Test. Results were positive. Student attainment was significantly raised during the 16-week implementation period by over one standard deviation. This equated to one-year’s worth of mathematics development during this time period. Results must be treated with caution. No control group was used in the pilot study. However, results are very promising and indicate that reciprocal role peer tutoring may be a useful pedagogy in Irish medium education. Further work would be required to establish this definitively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines the relationship between stature and later life health in 6 emerging economies, each of which are expected to experience significant increases in the mean age of their populations over the coming decades. Using data from the WHO Study on Global Ageing and Adult Health (SAGE) and pilot data from the Longitudinal Ageing Study in India (LASI), I show that various measures of health are associated with height, a commonly used proxy for childhood environment. In the pooled sample, a 10 cm increase in height is associated with between a 2 and 3 percentage point increase in the probability of being in very good or good self-reported health, a 3 percentage point increase in the probability of reporting no difficulties with activities of daily living or instrumental activities of daily living, and between a fifth and a quarter of a standard deviation increase in grip strength and lung function. Adopting a methodology previously used in the research on inequality, I also summarise the height-grip strength gradient for each country using the concentration index, and provide a decomposition analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose
The Strengths and Difficulties Questionnaire (SDQ) is a behavioural screening tool for children. The SDQ is increasingly used as the primary outcome measure in population health interventions involving children, but it is not preference based; therefore, its role in allocative economic evaluation is limited. The Child Health Utility 9D (CHU9D) is a generic preference-based health-related quality of-life measure. This study investigates the applicability of the SDQ outcome measure for use in economic evaluations and examines its relationship with the CHU9D by testing previously published mapping algorithms. The aim of the paper is to explore the feasibility of using the SDQ within economic evaluations of school-based population health interventions.
Methods
Data were available from children participating in a cluster randomised controlled trial of the school-based roots of empathy programme in Northern Ireland. Utility was calculated using the original and alternative CHU9D tariffs along with two SDQ mapping algorithms. t tests were performed for pairwise differences in utility values from the preference-based tariffs and mapping algorithms.
Results
Mean (standard deviation) SDQ total difficulties and prosocial scores were 12 (3.2) and 8.3 (2.1). Utility values obtained from the original tariff, alternative tariff, and mapping algorithms using five and three SDQ subscales were 0.84 (0.11), 0.80 (0.13), 0.84 (0.05), and 0.83 (0.04), respectively. Each method for calculating utility produced statistically significantly different values except the original tariff and five SDQ subscale algorithm.
Conclusion
Initial evidence suggests the SDQ and CHU9D are related in some of their measurement properties. The mapping algorithm using five SDQ subscales was found to be optimal in predicting mean child health utility. Future research valuing changes in the SDQ scores would contribute to this research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To study the effect of multimedia education on acceptance of comprehensive eye examinations (CEEs), critical for detecting glaucoma and diabetic eye disease, among rural Chinese patients using a randomized, controlled design.
METHODS: Patients aged ≥40 years were recruited from 52 routine clinic sessions (26 intervention, 26 control) conducted at seven rural hospitals in Guangdong, China. Subjects answered demographic questionnaires, were tested on knowledge about CEEs and chronic eye disease, and were told the cost of examination (range US$0-8). At intervention sessions, subjects were cluster-randomized to view a 10-minute video on the value of CEEs and retested. Control subjects were not retested. Trial outcomes were acceptance of CEEs (primary outcome) and final knowledge scores (secondary outcome).
RESULTS: At baseline, >70% (p = 0.70) of both intervention (n = 241, 61.2 ± 12.3 years) and control (n = 218, 58.4 ± 11.7 years) subjects answered no knowledge questions correctly, but mean scores on the test (maximum 5 points) increased by 1.39 (standard deviation 0.12) points (p < 0.001) after viewing the video. Intervention (73.0%) and control (72.9%) subjects did not differ in acceptance of CEEs (p > 0.50). In mixed-effect logistic regression models, acceptance of CEEs was associated with availability of free CEEs (odds ratio 18.3, 95% confidence interval 1.32-253.0), but not group assignment or knowledge score. Acceptance was 97.5% (79/81) when free exams were offered.
CONCLUSIONS: Education increased knowledge about but not acceptance of CEEs, which was generally high. Making CEEs free could further increase acceptance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Disordered sleep and myopia are increasingly prevalent among Chinese children. Similar pathways may be involved in regulation of both sleep cycles and eye growth. We therefore sought to examine the association between disordered sleep and myopia in this group. METHODS: Urban primary school children participating in a clinical trial on myopia and outdoor activity underwent automated cycloplegic refraction with subjective refinement. Parents answered questions about children's sleep duration, sleep disorders (Children's Sleep Habits Questionnaire [CSHQ]), near work and time spent outdoors. RESULTS: Among 1970 children, 1902 (96.5%, mean [standard deviation SD] age 9.80 [0.44] years, 53.1% boys) completed refraction and questionnaires. Myopia < = -0.50 Diopters was present in both eyes of 588 (30.9%) children (1329/3804 = 34.9% of eyes) and 1129 children (59.4%) had abnormal CSHQ scores (> 41). In logistic regression models by eye, odds of myopia < = -0.50D increased with worse CSHQ score (Odds Ratio [OR] 1.01 per point, 95% Confidence Interval [CI] [1.001, 1.02], P = 0.014) and more night-time sleep (OR 1.02, 95% CI [1.01, 1.04, P = 0.002], while male sex (OR 0.82, 95% CI [0.70, 0.95], P = 0.008) and time outdoors (OR = 0.97, 95% CI [0.95, 0.99], P = 0.011) were associated with less myopia. The association between sleep duration and myopia was not significant (p = 0.199) for total (night + midday) sleep. CONCLUSIONS: Myopia and disordered sleep were both common in this cohort, but we did not find consistent evidence for an association between the two. TRIAL REGISTRATION: clinicaltrials.gov NCT00848900.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: This study aims to assess the quality of various steps of manual small incision cataract surgery and predictors of quality, using video recordings.
DESIGN: This paper applies a retrospective study.
PARTICIPANTS: Fifty-two trainees participated in a hands-on small incision cataract surgery training programme at rural Chinese hospitals.
METHODS: Trainees provided one video each recorded by a tripod-mounted digital recorder after completing a one-week theoretical course and hands-on training monitored by expert trainers. Videos were graded by two different experts, using a 4-point scale developed by the International Council of Ophthalmology for each of 12 surgical steps and six global factors. Grades ranged from 2 (worst) to 5 (best), with a score of 0 if the step was performed by trainers.
MAIN OUTCOME MEASURES: Mean score for the performance of each cataract surgical step rated by trainers.
RESULTS: Videos and data were available for 49/52 trainees (94.2%, median age 38 years, 16.3% women and 77.5% completing > 50 training cases). The majority (53.1%, 26/49) had performed ≤ 50 cataract surgeries prior to training. Kappa was 0.57∼0.98 for the steps (mean 0.85). Poorest-rated steps were draping the surgical field (mean ± standard deviation = 3.27 ± 0.78), hydro-dissection (3.88 ± 1.22) and wound closure (3.92 ± 1.03), and top-rated steps were insertion of viscoelastic (4.96 ± 0.20) and anterior chamber entry (4.69 ± 0.74). In linear regression models, higher total score was associated with younger age (P = 0.015) and having performed >50 independent manual small incision cases (P = 0.039).
CONCLUSIONS: More training should be given to preoperative draping, which is poorly performed and crucial in preventing infection. Surgical experience improves ratings.© 2015 Royal Australian and New Zealand College of Ophthalmologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE:

We sought to measure the impact of central corneal thickness (CCT), a possible risk factor for glaucoma damage, and corneal hysteresis, a proposed measure of corneal resistance to deformation, on various indicators of glaucoma damage.

DESIGN:

Observational study.

METHODS:

Adult patients of the Wilmer Glaucoma Service underwent measurement of hysteresis on the Reichert Ocular Response Analyzer and measurement of CCT by ultrasonic pachymetry. Two glaucoma specialists (H.A.Q., N.G.C.) reviewed the chart to determine highest known intraocular pressure (IOP), target IOP, diagnosis, years with glaucoma, cup-to-disk ratio (CDR), mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), and presence or absence of visual field progression.

RESULTS:

Among 230 subjects, the mean age was 65 +/- 14 years, 127 (55%) were female, 161 (70%) were white, and 194 (85%) had a diagnosis of primary open-angle glaucoma (POAG) or suspected POAG. In multivariate generalized estimating equation models, lower corneal hysteresis value (P = .03), but not CCT, was associated with visual field progression. When axial length was included in the model, hysteresis was not a significant risk factor (P = .09). A thinner CCT (P = .02), but not hysteresis, was associated with a higher CDR at the most recent examination. Neither CCT nor hysteresis was associated with MD, PSD, or GHT "outside normal limits."

CONCLUSIONS:

Thinner CCT was associated with the state of glaucoma damage as indicated by CDR. Axial length and corneal hysteresis were associated with progressive field worsening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE:

To determine the test-retest variability in perimetric, optic disc, and macular thickness parameters in a cohort of treated patients with established glaucoma.

PATIENTS AND METHODS:

In this cohort study, the authors analyzed the imaging studies and visual field tests at the baseline and 6-month visits of 162 eyes of 162 participant in the Glaucoma Imaging Longitudinal Study (GILS). They assessed the difference, expressed as the standard error of measurement, of Humphrey field analyzer II (HFA) Swedish Interactive Threshold Algorithm fast, Heidelberg retinal tomograph (HRT) II, and retinal thickness analyzer (RTA) parameters between the two visits and assumed that this difference was due to measurement variability, not pathologic change. A statistically significant change was defined as twice the standard error of measurement.

RESULTS:

In this cohort of treated glaucoma patients, it was found that statistically significant changes were 3.2 dB for mean deviation (MD), 2.2 for pattern standard deviation (PSD), 0.12 for cup shape measure, 0.26 mm for rim area, and 32.8 microm and 31.8 microm for superior and inferior macular thickness, respectively. On the basis of these values, it was estimated that the number of potential progression events detectable in this cohort by the parameters of MD, PSD, cup shape measure, rim area, superior macular thickness, and inferior macular thickness was 7.5, 6.0, 2.3, 5.7, 3.1, and 3.4, respectively.

CONCLUSIONS:

The variability of the measurements of MD, PSD, and rim area, relative to the range of possible values, is less than the variability of cup shape measure or macular thickness measurements. Therefore, the former measurements may be more useful global measurements for assessing progressive glaucoma damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. METHODS: Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). RESULTS: The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P < .001). CONCLUSION: Although the pressure phosphene tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children.