916 resultados para COATED IMPLANTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cranioplasty is a commonly performed procedure. Outcomes can be improved by the use of patient specific implants, however, high costs limit their accessibility. This paper presents a low cost alternative technique to create patient specific polymethylmethacrylate (PMMA) implants using rapid prototyped mold template. We used available patient's CT-scans, one dataset without craniotomy and one with craniotomy, for computer-assisted design of a 3D mold template, which itself can be brought into the operating room and be used for fast and easy building of a PMMA implant. We applied our solution to three patients with positive outcomes and no complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The temporal pattern of bone-level alterations in conventionally restored implants is dependent upon healing mode (open or submerged). This study examined the influence of healing on marginal bone levels at implants with a medium-rough surface including the implant collar and a clearance-fit implant-abutment connection restored according to a platform-switching concept.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study summarizes the long-term clinical observations of edentulous patients treated with mandibular implant-supported overdentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this review was to compare peri-implant mucositis and gingivitis with respect to the pathogenesis aspects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to use autologous dental progenitor cells (DPCs) to form organized periodontal tissues on titanium implants would be a significant improvement over current implant therapies. Based on prior experimental results, we hypothesized that rat periodontal ligament (PDL)-derived DPCs can be used to bioengineer PDL tissues on titanium implants in a novel, in vivo rat maxillary molar implant model. Analyses of recovered implants revealed organized PDL tissues surrounding titanium implant surfaces in PDL-cell-seeded, and not in unseeded control, implants. Rat PDL DPCs also exhibited differentiative potential characteristic of stem cells. These proof-of-principle findings suggest that PDL DPCs can organize periodontal tissues in the jaw, at the site of previously lost teeth, indicating that this method holds potential as an alternative approach to osseointegrated dental implants. Further refinement of this approach will facilitate the development of clinically relevant methods for autologous PDL regeneration on titanium implants in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A minimal marginal bone loss around implants during early healing has been considered acceptable. However, the preservation of the marginal bone is related to soft tissue stability and esthetics. Implant designs and surfaces were evaluated to determine their impact on the behavior of the crestal bone. The purpose of this study is to evaluate histologic marginal bone level changes around early loaded, chemically modified, sandblasted acid-etched-surfaced implants with a machined collar (MC) or no MC (NMC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown that peri-implant crestal bone reactions are influenced by both a rough-smooth implant border in one-piece, non-submerged, as well as an interface (microgap [MG] between implant/abutment) in two-piece butt-joint, submerged and non-submerged implants being placed at different levels in relation to the crest of the bone. According to standard surgical procedures, the rough-smooth implant border for implants with a smooth collar should be aligned with the crest of the bone exhibiting a smooth collar adjacent to peri-implant soft tissues. No data, however, are available for implants exhibiting a sandblasted, large-grit and acid-etched (SLA) surface all the way to the top of a non-submerged implant. Thus, the purpose of this study is to histometrically examine crestal bone changes around machined versus SLA-surfaced implant collars in a side-by-side comparison.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implants made of commercially pure titanium (cpTi) are widely and successfully used in dentistry. For certain indications, diameter-reduced Ti alloy implants with improved mechanical strength are highly desirable. The aim was to compare the osseointegration of titanium-zirconium (TiZr) and cpTi implants with a modified sandblasted and acid-etched (SLActive) surface and with a Ti6Al4V alloy that was sand-blasted and acid-washed. Cylindrical implants with two, 0.75 mm deep, circumferential grooves were placed in the maxilla of miniature pigs and allowed to heal for 1, 2, 4 and 8 weeks. Undecalcified toluidine blue-stained ground sections were produced. Surface topography, area fraction of tissue components, and bone-to-implant contact (BIC) were determined. All materials showed significantly different surface roughness parameters. The amount of new bone within the implant grooves increased over time, without significant differences between materials. However, BIC values were significantly related to the implant material and the healing period. For TiZr and cpTi implants, the BIC increased over time, reaching values of 59.38 % and 76.15 % after 2 weeks, and 74.50 % and 84.67 % after 8 weeks, respectively. In contrast, the BIC for Ti6Al4V implants peaked with 42.29 % after 2 weeks followed by a decline to 28.60 % at 8 weeks. Significantly more surface was covered by multinucleated giant cells on Ti6Al4V implants after 4 and 8 weeks. In conclusion, TiZr and cpTi implants showed faster osseointegration than Ti6Al4V implants. Both chemistry and surface topography might have influenced the results. The use of diameter-reduced TiZr implants in more challenging clinical situations warrants further documentation in long-term clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Excessive cantilever lengths of fixed implant-supported prostheses may have functional and biomechanical disadvantages. This study reports the clinical outcomes of unconventional implants placed for distal support of a fixed implant-supported prostheses. Seven extraoral implants with intraosseous lengths of 2.5 to 4.0 mm were placed in four patients. Distal cantilevers had a mean length of 29.8 mm (range, 18.6 to 39.3 mm). No bone loss or other adverse events were found. The prosthetic plan was maintained in all patients. Within the limits of the employed research design, this concept seems to be a successful option for fixed complete implant-supported prosthesis treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the patient benefit of the Bone-Anchored Hearing Aid (Baha) Divino and the Baha BP100 sound processors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to assess speech perception and communication skills in adolescents between ages 8 and 18 that received cochlear implants for pre- and peri-lingual deafness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). Background Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. Methods In an assessor-blind noninferiority study, 302 patients undergoing percutaneous coronary intervention were randomized to treatment with TiNO or ZES. The primary endpoint was in-stent late loss at 6 to 8 months, and analysis was by intention to treat. Results Both groups were well balanced with respect to baseline clinical and angiographic characteristics. The TiNO group failed to reach the pre-specified noninferiority margin for the primary endpoint (in-stent late loss: 0.64 ± 0.61 mm vs. 0.47 ± 0.48 mm, difference: 0.16, upper 1-sided 95% confidence interval [CI]: 0.26; pnoninferiority = 0.54), and subsequent superiority testing was in favor of ZES (psuperiority = 0.02). In-segment binary restenosis was lower with ZES (11.1%) than with TiNO (20.5%; psuperiority = 0.04). A stratified analysis of the primary endpoint found particularly pronounced differences between stents among diabetic versus nondiabetic patients (0.90 ± 0.69 mm vs. 0.39 ± 0.38 mm; pinteraction = 0.04). Clinical outcomes showed a similar rate of death (0.7% vs. 0.7%; p = 1.00), myocardial infarction (5.3% vs. 6.7%; p = 0.60), and major adverse cardiac events (21.1% vs. 18.0%, hazard ratio: 1.19, 95% CI: 0.71 to 2.00; p = 0.50) at 1 year. There were no differences in rates of definite or probable stent thrombosis (0.7% vs. 0%; p = 0.51) at 1 year. Conclusions Compared with TiNO, ZES was superior with regard to late loss and binary restenosis. The concept of passive stent coating with TiNO remains inferior to drug-eluting stent technology in reducing restenosis. ([TIDE] Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent: NCT00492908)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas–volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.