870 resultados para Arthroplasty, Replacement, Ankle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the influence of three different postmenopausal hormone replacement therapies on levels of serum lipids and lipoprotein(a) [Lp(a)].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmenopausal bone loss can be prevented by continuous or intermittent estradiol (E2) administration. Concomitant progestogen therapy is mandatory in nonhysterectomized women to curtail the risk of endometrial hyperplasia or cancer. However, the recurrence of vaginal bleeding induced by sequential progestogen therapy in addition to continuous estrogen administration is one of the reasons for noncompliance to hormone replacement therapy (HRT). Tibolone, a synthetic steroid with simultaneous weak estrogenic, androgenic, and progestational activity, which does not stimulate endometrial proliferation, has recently been proposed for the treatment of climacteric symptoms. To compare the efficacy of conventional oral and transdermal HRT with that of tibolone in the prevention of postmenopausal bone loss, 140 postmenopausal women (age, 52 +/- 0.6 years; median duration of menopause, 3 years) were enrolled in an open 2-year study. Volunteers had been offered a choice between HRT and no therapy (control group, CO). Patients selecting HRT were randomly allocated to one of the following three treatment groups: TIB, tibolone, 2.5 mg/day continuously, orally; PO, peroral E2, 2 mg/day continuously, plus sequential oral dydrogesterone (DYD), 10 mg/day, for 14 days of a 28-day cycle; TTS, transdermal E2 by patch releasing 50 microg/day, plus DYD as above. Bone densitometry of the lumbar spine, upper femur, and whole body was performed using dual-energy X-ray absorptiometry at baseline, and then 6, 12, 18, and 24 months after initiation of therapy. One hundred and fifteen women (82%) completed the 2 years of the study. The dropout rate was similar in each group. Over 2 years, bone preservation was observed in all three treatment groups as compared with controls, without significant differences among treatment regimens. In conclusion, tibolone can be regarded as an alternative to conventional HRT to prevent postmenopausal bone loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A fixed cavovarus foot deformity can be associated with anteromedial ankle arthrosis due to elevated medial joint contact stresses. Supramalleolar valgus osteotomies (SMOT) and lateralizing calcaneal osteotomies (LCOT) are commonly used to treat symptoms by redistributing joint contact forces. In a cavovarus model, the effects of SMOT and LCOT on the lateralization of the center of force (COF) and reduction of the peak pressure in the ankle joint were compared. METHODS: A previously published cavovarus model with fixed hindfoot varus was simulated in 10 cadaver specimens. Closing wedge supramalleolar valgus osteotomies 3 cm above the ankle joint level (6 and 11 degrees) and lateral sliding calcaneal osteotomies (5 and 10 mm displacement) were analyzed at 300 N axial static load (half body weight). The COF migration and peak pressure decrease in the ankle were recorded using high-resolution TekScan pressure sensors. RESULTS: A significant lateral COF shift was observed for each osteotomy: 2.1 mm for the 6 degrees (P = .014) and 2.3 mm for the 11 degrees SMOT (P = .010). The 5 mm LCOT led to a lateral shift of 2.0 mm (P = .042) and the 10 mm LCOT to a shift of 3.0 mm (P = .006). Comparing the different osteotomies among themselves no significant differences were recorded. No significant anteroposterior COF shift was seen. A significant peak pressure reduction was recorded for each osteotomy: The SMOT led to a reduction of 29% (P = .033) for the 6 degrees and 47% (P = .003) for the 11 degrees osteotomy, and the LCOT to a reduction of 41% (P = .003) for the 5 mm and 49% (P = .002) for the 10 mm osteotomy. Similar to the COF lateralization no significant differences between the osteotomies were seen. CONCLUSION: LCOT and SMOT significantly reduced anteromedial ankle joint contact stresses in this cavovarus model. The unloading effects of both osteotomies were equivalent. More correction did not lead to significantly more lateralization of the COF or more reduction of peak pressure but a trend was seen. CLINICAL RELEVANCE: In patients with fixed cavovarus feet, both SMOT and LCOT provided equally good redistribution of elevated ankle joint contact forces. Increasing the amount of displacement did not seem to equally improve the joint pressures. The site of osteotomy could therefore be chosen on the basis of surgeon's preference, simplicity, or local factors in case of more complex reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finishing yearling steers fed a corn-based diet containing steep liquor had statistically similar live performance as steers fed the control diet. Numerically steers fed the steep containing diet were 6% more efficient. Steers fed steep liquor tended to contain less carcass fat (as measured by intramuscular marbling) less kidney, heart and pelvic fat, and less backfat thickness. When priced at $50/ton adding steep liquor at 10% of diet dry matter reduced feed cost for gain 9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy. BACKGROUND Since its commercialization in 2007, the number of TAVR procedures has grown exponentially. METHODS The adoption of TAVR was investigated in 11 European countries: Germany, France, Italy, United Kingdom, Spain, the Netherlands, Switzerland, Belgium, Portugal, Denmark, and Ireland. Data were collected from 2 sources: 1) lead physicians submitted nation-specific registry data; and 2) an implantation-based TAVR market tracker. Economic indexes such as healthcare expenditure per capita, sources of healthcare funding, and reimbursement strategies were correlated to TAVR use. Furthermore, we assessed the extent to which TAVR has penetrated its potential patient population. RESULTS Between 2007 and 2011, 34,317 patients underwent TAVR. Considerable variation in TAVR use existed across nations. In 2011, the number of TAVR implants per million individuals ranged from 6.1 in Portugal to 88.7 in Germany (33 ± 25). The annual number of TAVR implants performed per center across nations also varied widely (range 10 to 89). The weighted average TAVR penetration rate was low: 17.9%. Significant correlation was found between TAVR use and healthcare spending per capita (r = 0.80; p = 0.005). TAVR-specific reimbursement systems were associated with higher TAVR use than restricted systems (698 ± 232 vs. 213 ± 112 implants/million individuals ≥ 75 years; p = 0.002). CONCLUSIONS The authors' findings indicate that TAVR is underutilized in high and prohibitive surgical risk patients with severe aortic stenosis. National economic indexes and reimbursement strategies are closely linked with TAVR use and help explain the inequitable adoption of this therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). Methods and results: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3-D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3-D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3-D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3-D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm). Conclusions: MSCT-based 3-D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND In Chopart-level amputations the heel often deviates into equinus and varus when, due to the lack of healthy anterior soft tissue, rebalancing tendon transfers to the talar head are not possible. Consequently, anterior and lateral wound dehiscence and ulceration may occur requiring higher-level amputation to achieve wound closure, with considerable loss of function for the patients. METHODS Twenty-four consecutive patients (15 diabetes, 6 trauma, and 3 tumor) had Chopart's amputation and simultaneous or delayed additional ankle dorsiflexion arthrodesis to allow for tension-free wound closure or soft tissue reconstruction, or to treat secondary recurrent ulcerations. Percutaneous Achilles tendon lengthening and subtalar arthrodesis were added as needed. Wound healing problems, time to fusion and full weight-bearing in the prosthesis, complications in the prosthesis, and the ambulatory status were assessed. Satisfaction and function were evaluated by the AmpuPro score and the validated Prosthesis Evaluation Questionnaire scale. RESULTS Five patients had successful soft tissue healing and fusions but died of their underlying disease 2 to 46 months after the operation. Two diabetic patients required a transtibial amputation. The other 17 patients were followed for 27 months (range, 13-63). The average age of the 4 women and 13 men was 53.9 years (range, 16-87). Postoperative complications included minor wound healing problems in 8 patients, wound breakdown requiring revision in 4, phantom pain in 3, residual equinus in 1, and adjacent scar carcinoma in 1 patient. The time to full weight-bearing in the prosthesis ranged from 6 to 24 weeks (mean 10). The mean AmpuPro score was 107 points (of 120), and the mean Prosthesis Evaluation Questionnaire scale was 147 points (of 200). No complications occurred with the prosthesis. Twelve patients lost 1 to 2 mobility classes (mean 0.9). The arthrodeses all healed within 2.5 months (range, 1.5 to 5 months). CONCLUSION Adding an ankle arthrodesis to a Chopart's amputation either immediately or in a delayed fashion to treat anterior soft tissue complications was a successful salvage in most patients at this amputation level. It enabled the patients to preserve the advantages of a full-length limb with terminal weight-bearing. LEVEL OF EVIDENCE Level IV, retrospective case series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Ankle arthrodesis results in measurable improvements in terms of pain and function in patients with end-stage ankle arthritis. Arthroscopic ankle arthrodesis has gained increasing popularity, with reports of shorter hospital stays, shorter time to solid fusion, and equivalent union rates when compared with open arthrodesis. However, there remains a lack of high-quality prospective data. METHODS We evaluated the results of open and arthroscopic ankle arthrodesis in a comparative case series of patients who were managed at two institutions and followed for two years. The primary outcome was the Ankle Osteoarthritis Scale score, and secondary outcomes included the Short Form-36 physical and mental component scores, the length of hospital stay, and radiographic alignment. There were thirty patients in each group. RESULTS Both groups showed significant improvement in the Ankle Osteoarthritis Scale score and the Short Form-36 physical component score at one and two years. There was significantly greater improvement in the Ankle Osteoarthritis Scale score at one year and two years and shorter hospital stay in the arthroscopic arthrodesis group. Complications, surgical time, and radiographic alignment were similar between the two groups. CONCLUSIONS Open and arthroscopic ankle arthrodesis were associated with significant improvement in terms of pain and function as measured with the Ankle Osteoarthritis Scale score. Arthroscopic arthrodesis resulted in a shorter hospital stay and showed better outcomes at one and two years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One Arabian and 5 Hungarian half-bred horses were used to study the macroscopic and microscopic survival of autologous osteochondral grafts in the weight-bearing surface of the medial femoral condyle (MFC). Grafts were harvested from the cranial surface of the medial femoral trochlea (MFT) under arthroscopic control. Three of them were transplanted into the weight-bearing surface of the contralateral MFC using an arthrotomy approach. Three months later this transplantation procedure was repeated on the opposite stifle joints in the same animals, but at that time transplantation was performed arthroscopically. Follow-up arthroscopy was carried out 12 months after the first operations, and biopsies were taken from both the recipient and the donor sites for histological examination. During follow-up arthroscopy, the transplanted areas looked congruent and smooth. Microscopically, the characteristics of hyaline cartilage were present in 5 out of the 10 biopsies examined; however, in the other half of biopsies glycosaminoglycan (GAG) loss and change in the architecture of the transplanted cartilage was observed. In a 16-year-old horse, all grafts broke during harvesting, and thus transplantation was not performed. No radiological signs of osteoarthritic changes were detected 9 to 12 months after the operations in the donor and recipient joints. Clinically, no lameness or effusion was present three months after the transplantations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND While surgical navigation offers the opportunity to accurately place an acetabular component, questions remain as to the best goal for acetabular component positioning in individual patients. Overall functional orientation of the pelvis after surgery is one of the most important variables for the surgeon to consider when determining the proper goal for acetabular component orientation. QUESTIONS/PURPOSES We measured the variation in pelvic tilt in 30 patients before THA and the effect of THA on pelvic tilt in the same patients more than a year after THA. METHODS Each patient had a CT study for CT-based surgical navigation and standing and supine radiographs before and after surgery. Pelvic tilt was calculated for each of the radiographs using a novel and validated two-dimensional/three-dimensional matching technique. RESULTS Mean supine pelvic tilt changed less than 2°, from 4.4° ± 6.4° (range, -7.7° to 20.8°) before THA to 6.3° ± 6.6° (range, -5.7° to 19.6°) after THA. Mean standing pelvic tilt changed less than 1°, from 1.5° ± 7.2° (range, -13.1° to 12.8°) before THA to 2.0° ± 8.3° (range, -12.3° to 16.8°) after THA. Preoperative pelvic tilt correlated with postoperative tilt in both the supine (r(2) = 0.75) and standing (r(2) = 0.87) positions. CONCLUSIONS In this population, pelvic tilt had a small and predictable change after surgery. However, intersubject variability of pelvic tilt was high, suggesting preoperative pelvic tilt should be considered when determining desired acetabular component positioning on a patient-specific basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Marked differences exist between human knee and ankle joints regarding risks and progression of osteoarthritis (OA). Pathomechanisms of degenerative joint disease may therefore differ in these joints, due to differences in tissue structure and function. Focussing on structural issues which are design goals for tissue engineering, we compared cell and matrix morphologies in different anatomical sites of adult human knee and ankle joints. METHODS Osteochondral explants were acquired from knee and ankle joints of deceased persons aged 20 to 40 years and analyzed for cell, matrix and tissue morphology using confocal and electron microscopy and unbiased stereological methods. Variations associated with joint (knee versus ankle) and biomechanical role (convex versus concave articular surfaces) were identified by 2-way analysis of variance and post-hoc analysis. RESULTS Knee cartilage exhibited higher cell densities in the superficial zone than ankle cartilage. In the transitional zone, higher cell densities were observed in association with convex versus concave articular surfaces, without significant differences between knee and ankle cartilage. Highly uniform cell and matrix morphologies were evident throughout the radial zone in the knee and ankle, regardless of tissue biomechanical role. Throughout the knee and ankle cartilage sampled, chondron density was remarkably constant at approximately 4.2×10(6) chondrons/cm(3). CONCLUSION Variation of cartilage cell and matrix morphologies with changing joint and biomechanical environments suggests that tissue structural adaptations are performed primarily by the superficial and transitional zones. Data may aid the development of site-specific cartilage tissue engineering, and help identify conditions where OA is likely to occur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Resternotomy for aortic valve replacement in patients with previous coronary artery bypass grafting and an internal mammary artery graft may be a surgical problem. Thus, we are exploring the effect of using rapid prototyping techniques for surgical planning and intraoperative orientation during aortic valve replacement after previous coronary artery bypass grafting (CABG). DESCRIPTION As a proof of concept, we studied a patient who had undergone CABG 5 years earlier. At that time the patient received a left internal mammary artery graft to the left anterior descending artery and a venous graft to the right coronary artery. Now the patient required aortic valve replacement due to symptomatic aortic valve stenosis. The left internal mammary artery bypass and the right coronary artery bypass were patent and showed good flow in the angiography. The patient was examined by 128-slice computed tomography. The image data were visualized and reconstructed. Afterwards, a replica showing the anatomic structures was fabricated using a rapid prototyping machine. EVALUATION Using data derived from 128-slice computed tomography angiography linked to proprietary software, we were able to create three-dimensional reconstructions of the vascular anatomy after the previous CABG. The models were sterilized and taken to the operating theatre for orientation during the surgical procedure. CONCLUSIONS Stereolithographic replicas are helpful for choosing treatment strategies in surgical planning and for intraoperative orientation during reoperations of patients with previous CABG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The published data on pain and physical function before and after revision of total hip arthroplasty (THA) is scarce. The study reports the course and interrelationships of radiographic loosening, pain and physical function 5 year before and after a first revision THA. Methods: The study was based on the IDES-THA database. All patients with their first THA revision for aseptic loosening and a documented index surgery on the same side and at least one pre-revision and one post-revision follow-up were selected. Only patients with an intact contralateral hip joint (Charnley class-A) were included. Follow-ups within ±5.5 years around the revision time point were analyzed. Annual prevalences of radiographic component loosening and the non-desired outcomes (moderate/severe/intolerable pain, walking <30 minutes, hip flexion range <90°) were calculated. Results: Signs of radiographic component loosening started to increase about 4 years before revision surgery. Two years later, a sharp increase of painful hips from 15% to 80% in the revision year was observed. In the year after revision surgery, this rate dropped back to below 10%. Walking capacity started to noticeably deteriorate 3 years before revision and in the revision year about 65% of patients could not walk longer than 30 minutes. As opposed to pain, walking capacity did not recover to pre-revision levels and the best outcome was only reached two years post-revision. Hip flexion range had the slowest and least extent of deterioration (≈45% flexed <70° in the revision year) but with the best outcomes at only three years after revision surgery it took the longest to recover. Conclusion: Prevalence of radiological loosening signs and/or pain intensity follow an almost parallel course around the first revision of a THA for aseptic component loosening. This process begins about 4 years (radiographic loosening) before the actual revision surgery and intensifies about 2 years later (pain). It also involves walking capacity and hip range of motion. While pain levels go back to levels similar to those after primary surgery, range of motion and even more walking capacity remain moderately compromised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.