Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement


Autoria(s): Stortecky, Stefan; Heg, Dik; Glökler, Steffen; Wenaweser, Peter Martin; Windecker, Stephan; Büllesfeld, Lutz
Data(s)

20/07/2014

Resumo

Aims: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). Methods and results: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3-D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3-D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3-D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3-D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm). Conclusions: MSCT-based 3-D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.

Formato

application/pdf

Identificador

http://boris.unibe.ch/41943/1/Stortecky%20EuroIntervention%202014.pdf

Stortecky, Stefan; Heg, Dik; Glökler, Steffen; Wenaweser, Peter Martin; Windecker, Stephan; Büllesfeld, Lutz (2014). Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement. EuroIntervention, 10(3), pp. 339-346. Europa Digital & Publishing

doi:10.7892/boris.41943

info:pmid:24273249

urn:issn:1774-024X

Idioma(s)

eng

Publicador

Europa Digital & Publishing

Relação

http://boris.unibe.ch/41943/

Direitos

info:eu-repo/semantics/openAccess

Fonte

Stortecky, Stefan; Heg, Dik; Glökler, Steffen; Wenaweser, Peter Martin; Windecker, Stephan; Büllesfeld, Lutz (2014). Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement. EuroIntervention, 10(3), pp. 339-346. Europa Digital & Publishing

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed