1000 resultados para Acanthocyclops americanus, copepodites, mass
Resumo:
SUMMARY : Peroxisome proliferator-activated receptor ß/δ protects against obesity by reducing dyslipidemia and insulin resistance via effects in various organs, including muscle, adipose tissue and liver. However, nothing is known about the function of PPARß in pancreas, a prime organ in the control of glucose homeostasis. To gain insight into so far hypothetical functions of this PPAR isotype in ß-cell function, we specifically ablated Pparß in the whole epithelial compartment of the pancreas. The mutated mice presented expanded ß-cell mass, possibly, this is due to increased burst of ß-cell proliferation at 2 weeks of age. These PPARß null pancreas mice exhibit hyperinsulinemia-hypoglycaemia starting at 4 weeks of age, due to hyperfunctionality of ß-cell. Gene expression profiling indicated a broad repressive function of PPARß impacting the vesicular and granular compartment, actin cytoskeleton, and metabolism of glucose and fatty acids. Analyses of insulin release from isolated islets revealed accelerated second-phase of glucose-stimulated insulin secretion. Higher levels of PKD and PKCS in mutated animals, in concert with F-actin disassembly, lead to an increased insulin secretion and its associated systemic effects. Enhanced palmitate potentiation of glucose-stimulated insulin secretion in PPARß mutant islets, suggests an important role of this receptor in lipid/glucose metabolism in ß-cell. Taken together, these results provide evidence for PPARß playing a repressive role on ß-cell growth and insulin exocytosis, and shed new light on its metabolic .action. RESUME : Le récepteur nucléaire PPARß (Peroxisome proliferator-activated receptor ß/δ) protège contre l'obésité en réduisant la dyslipidémie et la résistance à l'insuline dans différents organes, comme le muscle, le tissue adipeux et le foie. Cependant, il y a, à ce jour, très peu de connaissance par rapport au rôle de PPARß dans le pancréas, qui est un organe très important dans le contrôle homéostatique du glucose. Afin de comprendre le rôle de cet isotype de PPAR dans le fonctionnement des cellules beta du pancréas, nous avons invalidé le gène Pparß dans tout le compartiment pancréatique de la souris. Ces souris mutantes présentent une augmentation de la masse totale de cellules beta; Cela serait dû à une intense prolifération des cellules beta à 2 semaines après la naissance. Également, ces souris présentent une hyperinsulinémie et une hypoglycémie qui commencent à l'âge de 4 semaines; la raison de ce phénotype serait une hyperactivité des cellules beta. Le profil d'expression génique indique une fonction répressive globale de PPARß en se référant aux compartiments vésiculaire et granulaire, au cytosquelette d'actine, et au métabolisme du glucose et des acides gras. L'analyse de la sécrétion d'insuline par les cellules beta a démontré que la deuxième phase de sécrétion d'insuline après stimulation au glucose est augmentée. Les niveaux élevés de PKD et PKCS dans les îlots pancréatiques de souris mutantes, ainsi qu'une augmentation de la dépolymérisation des filaments d'active génèrent un surplus de sécrétion d'insuline après stimulation au glucose. Les îlots pancréatiques des souris mutantes secrètent plus d'insuline après stimulation au glucose et au palmitate que les îlots de souris contrôles. Ceci suggère un rôle important de PPARß dans le métabolisme des lipides et du glucose des cellules beta. En résumé, ces résultats mettent en évidence un rôle répressif de PPARß dans la croissance des cellules beta et dans l'exocytose d'insuline.
Resumo:
A highly sensitive ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of buprenorphine and its major metabolite norbuprenorphine in human plasma. In order to speed up the process and decrease costs, sample preparation was performed by simple protein precipitation with acetonitrile. To the best of our knowledge, this is the first application of this extraction technique for the quantification of buprenorphine in plasma. Matrix effects were strongly reduced and selectivity increased by using an efficient chromatographic separation on a sub-2μm column (Acquity UPLC BEH C18 1.7μm, 2.1×50mm) in 5min with a gradient of ammonium formate 20mM pH 3.05 and acetonitrile as mobile phase at a flow rate of 0.4ml/min. Detection was made using a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The procedure was fully validated according to the latest Food and Drug Administration guidelines and the Société Française des Sciences et Techniques Pharmaceutiques. Very good results were obtained by using a stable isotope-labeled internal standard for each analyte, to compensate for the variability due to the extraction and ionization steps. The method was very sensitive with lower limits of quantification of 0.1ng/ml for buprenorphine and 0.25ng/ml for norbuprenorphine. The upper limit of quantification was 250ng/ml for both drugs. Trueness (98.4-113.7%), repeatability (1.9-7.7%), intermediate precision (2.6-7.9%) and internal standard-normalized matrix effects (94-101%) were in accordance with international recommendations. The procedure was successfully used to quantify plasma samples from patients included in a clinical pharmacogenetic study and can be transferred for routine therapeutic drug monitoring in clinical laboratories without further development.
Resumo:
Common variants at only two loci, FTO and MC4R, have been reproducibly associated with body mass index (BMI) in humans. To identify additional loci, we conducted meta-analysis of 15 genome-wide association studies for BMI (n > 32,000) and followed up top signals in 14 additional cohorts (n > 59,000). We strongly confirm FTO and MC4R and identify six additional loci (P < 5 x 10(-8)): TMEM18, KCTD15, GNPDA2, SH2B1, MTCH2 and NEGR1 (where a 45-kb deletion polymorphism is a candidate causal variant). Several of the likely causal genes are highly expressed or known to act in the central nervous system (CNS), emphasizing, as in rare monogenic forms of obesity, the role of the CNS in predisposition to obesity.
Resumo:
Vaahdonestoaineiden haitallinen vaikutus hapen liukenemisnopeuteen biologisen puhdistamon jätevesissä on yleisesti tunnettua. Aineiden eri vaikutusmekanismien takia on silti vaikea etukäteen arvioida, miten ja kuinka paljon aineensiirto muuttuu. Työn tavoitteena oli saada tietoa vaahdonestoaineiden ja muiden pinta-aktiivisten aineiden vaikutuksesta kuplakokoon, kaasun tilavuusosuuteen ja kaasu-neste aineensiirtoon. Työn teoriaosassa on kuvailtu vaahdon muodostumiseen vaikuttavia tekijöitä sekä eri vaahdonestoaineiden vaikutusmekanismeja sellu- ja paperitehtaan jätevedessä. Edelleen on esitetty useita hapen siirtoa estäviä ja parantavia aineita. Työn kokeellisessa osassa tutkittiin kahdenkymmenenviiden eri pinta-aktiivisen aineen vaikutusta hapen liukenemisnopeuteen yksivaiheisessa kuplakolonnissa. Kokeet tehtiin kahdella pitoisuudella, kahdella eri kaasunjakolaitteella ja kolmella eri kaasun tyhjäputkinopeudella. Aineensiirtokokeiden rinnalla tutkittiin jätevesien laatu- ja fysikaalisiaominaisuuksia, niiden vaikutusta hapen liukenemisnopeuteen sekä testattavien koeaineiden vaikutusta fysikaalisin ominaisuuksiin. Kokeet osoittavat että pinta-aktiivisten aineiden vaikutus hapen aineensiirtoon vaihtelee riippuen kaasunjakolaitteesta ja aineen pitoisuuksista. Testatuista vaahdonestonaineista pienin negatiivinen vaikutus oli aineella AT 35 ja positiivinen vaikutustodettiin olevan vaahdonestoaineiden komponenteilla: P2, S1, F4 ja T9.
Resumo:
Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.
Resumo:
We assessed the association between several cardiometabolic risk factors (CRFs) (blood pressure, LDL-cholesterol, HDL-cholesterol, triglycerides, uric acid, and glucose) in 390 young adults aged 19-20 years in Seychelles (Indian Ocean, Africa) and body mass index (BMI) measured either at the same time (cross-sectional analysis) or at the age of 12-15 years (longitudinal analysis). BMI tracked markedly between age of 12-15 and age of 19-20. BMI was strongly associated with all considered CRFs in both cross-sectional and longitudinal analyses, with some exceptions. Comparing overweight participants with those having a BMI below the age-specific median, the odds ratios for high blood pressure were 5.4/4.7 (male/female) cross-sectionally and 2.5/3.9 longitudinally (P < 0.05). Significant associations were also found for most other CRFs, with some exceptions. In linear regression analysis including both BMI at age of 12-15 and BMI at age of 19-20, only BMI at age of 19-20 remained significantly associated with most CRFs. We conclude that CRFs are predicted strongly by either current or past BMI levels in adolescents and young adults in this population. The observation that only current BMI remained associated with CRFs when including past and current levels together suggests that weight control at a later age may be effective in reducing CRFs in overweight children irrespective of past weight status.
Resumo:
The establishment of legislative rules about explosives in the eighties has reduced the illicit use of military and civilian explosives. However, bomb-makers have rapidly taken advantage of substances easily accessible and intended for licit uses to produce their own explosives. This change in strategy has given rise to an increase of improvised explosive charges, which is moreover assisted by the ease of implementation of the recipes, widely available through open sources. While the nature of the explosive charges has evolved, instrumental methods currently used in routine, although more sensitive than before, have a limited power of discrimination and allow mostly the determination of the chemical nature of the substance. Isotope ratio mass spectrometry (IRMS) has been applied to a wide range of forensic materials. Conclusions drawn from the majority of the studies stress its high power of discrimination. Preliminary studies conducted so far on the isotopic analysis of intact explosives (pre-blast) have shown that samples with the same chemical composition and coming from different sources could be differentiated. The measurement of stable isotope ratios appears therefore as a new and remarkable analytical tool for the discrimination or the identification of a substance with a definite source. However, much research is still needed to assess the validity of the results in order to use them either in an operational prospect or in court. Through the isotopic study of black powders and ammonium nitrates, this research aims at evaluating the contribution of isotope ratio mass spectrometry to the investigation of explosives, both from a pre-blast and from a post-blast approach. More specifically, the goal of the research is to provide additional elements necessary to a valid interpretation of the results, when used in explosives investigation. This work includes a fundamental study on the variability of the isotopic profile of black powder and ammonium nitrate in both space and time. On one hand, the inter-variability between manufacturers and, particularly, the intra-variability within a manufacturer has been studied. On the other hand, the stability of the isotopic profile over time has been evaluated through the aging of these substances exposed to different environmental conditions. The second part of this project considers the applicability of this high-precision technology to traces and residues of explosives, taking account of the characteristics specific to the field, including their sampling, a probable isotopic fractionation during the explosion, and the interferences with the matrix of the site.
Resumo:
The present work describes a fast gas chromatography/negative-ion chemical ionization tandem mass spectrometric assay (Fast GC/NICI-MS/MS) for analysis of tetrahydrocannabinol (THC), 11-hydroxy-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in whole blood. The cannabinoids were extracted from 500 microL of whole blood by a simple liquid-liquid extraction (LLE) and then derivatized by using trifluoroacetic anhydride (TFAA) and hexafluoro-2-propanol (HFIP) as fluorinated agents. Mass spectrometric detection of the analytes was performed in the selected reaction-monitoring mode on a triple quadrupole instrument after negative-ion chemical ionization. The assay was found to be linear in the concentration range of 0.5-20 ng/mL for THC and THC-OH, and of 2.5-100 ng/mL for THC-COOH. Repeatability and intermediate precision were found less than 12% for all concentrations tested. Under standard chromatographic conditions, the run cycle time would have been 15 min. By using fast conditions of separation, the assay analysis time has been reduced to 5 min, without compromising the chromatographic resolution. Finally, a simple approach for estimating the uncertainty measurement is presented.
Resumo:
The studies of flow phenomena, heat and mass transfer in microchannel reactors are beneficial to estimate and evaluate the ability of microchannel reactors to be operated for a given process reaction such as Fischer-Tropsch synthesis. The flow phenomena, for example, the flow regimes and flow patterns in microchannel reactors for both single phase and multiphase flow are affected by the configuration of the flow channel. The reviews of the previous works about the analysis of related parameters that affect the flow phenomena are shown in this report. In order to predict the phenomena of Fischer-Tropsch synthesis in microchannel reactors, the 3-dimensional computational fluid dynamic simulation with commercial software package FLUENT was done to study the flow phenomena and heat transfer for gas phase Fischer-Tropsch products flow in rectangular microchannel with hydraulic diameter 500 ¿m and length 15 cm. Numerical solution with slip boundary condition was used in the simulation and the flowphenomena and heat transfer were determined.
Resumo:
Diplomityön tavoitteena on tutkia mitä uusia tiedonhallinnallisia ongelmia ilmenee, kun massaräätälöidyn tuotteen tuotetieto hallitaan läpi tuotteen elinkaaren, sekä miten nämä ongelmat voitaisiin ratkaista. Ongelmat ja haasteet kerätään kirjallisuuslähteistä ja massaräätälöintiprosessi yhdistetään PLM-vaiheisiin. Ratkaisua tutkitaan testaamalla kuinka standardit STEP ja PLCS sekä standardeja tukeva PLM järjestelmä voisivat tukea massaräätälöidyn tuotteen elinkaaren tiedonhallintaa. MC tuotteiden ongelmia ovat tuoterakenteen monimutkaisuus, jäljitettävyys ja muutosten hallinta läpi elinkaaren. STEP ja PLCS pystyvät kummatkin tahollaan tukemaan tiedonhallintaa. MC-tuotteen geneerinen tuoterakenne on kuitenkin manuaalisesti liittettävä elinkaaritiedon tukemiseen. PLM-järjestelmä pystyy tukemaan MC-tuotteiden elinkaarta, mutta koska toiminto ei ole järjestelmään sisäänrakennettuna, MC-tuotteiden tukemisen parantamisessa on edelleen haasteita.
Resumo:
The ratio of resting metabolic rate (RMR) to fat-free mass (FFM) is often used to compare individuals of different body sizes. Because RMR has not been well described over the full range of FFM, a literature review was conducted among groups with a wide range of FFM. It included 31 data sets comprising a total of 1111 subjects: 118 infants and preschoolers, 323 adolescents, and 670 adults; FFM ranged from 2.8 to 106 kg. The relationship of RMR to FFM was found to be nonlinear and average slopes of the regression equations of the three groups differed significantly (P less than 0.0001). For only the youngest group did the intercept approach zero. The lower slopes of RMR on FFM, at higher measures of FFM, corresponded to relatively greater proportions of less metabolically active muscle mass and to lesser proportions of more metabolically active nonmuscle organ mass. Because the contribution of FFM to RMR is not constant, an arithmetic error is introduced when the ratio of RMR to FFM is used. Hence, alternative methods should be used to compare individuals with markedly different FFM.
Resumo:
FTO is the strongest known genetic susceptibility locus for obesity. Experimental studies in animals suggest the potential roles of FTO in regulating food intake. The interactive relation among FTO variants, dietary intake and body mass index (BMI) is complex and results from previous often small-scale studies in humans are highly inconsistent. We performed large-scale analyses based on data from 177,330 adults (154 439 Whites, 5776 African Americans and 17 115 Asians) from 40 studies to examine: (i) the association between the FTO-rs9939609 variant (or a proxy single-nucleotide polymorphism) and total energy and macronutrient intake and (ii) the interaction between the FTO variant and dietary intake on BMI. The minor allele (A-allele) of the FTO-rs9939609 variant was associated with higher BMI in Whites (effect per allele = 0.34 [0.31, 0.37] kg/m(2), P = 1.9 × 10(-105)), and all participants (0.30 [0.30, 0.35] kg/m(2), P = 3.6 × 10(-107)). The BMI-increasing allele of the FTO variant showed a significant association with higher dietary protein intake (effect per allele = 0.08 [0.06, 0.10] %, P = 2.4 × 10(-16)), and relative weak associations with lower total energy intake (-6.4 [-10.1, -2.6] kcal/day, P = 0.001) and lower dietary carbohydrate intake (-0.07 [-0.11, -0.02] %, P = 0.004). The associations with protein (P = 7.5 × 10(-9)) and total energy (P = 0.002) were attenuated but remained significant after adjustment for BMI. We did not find significant interactions between the FTO variant and dietary intake of total energy, protein, carbohydrate or fat on BMI. Our findings suggest a positive association between the BMI-increasing allele of FTO variant and higher dietary protein intake and offer insight into potential link between FTO, dietary protein intake and adiposity.
Resumo:
Objective: to assess the diagnostic accuracy of different anthropometric markers in defining low aerobic fitness among adolescents. Methods: cross-sectional study on 2,331 boys and 2,366 girls aged 10 - 18 years. Body mass index (BMI) was measured using standardized methods; body fat (BF) was assessed by bioelectrical impedance. Low aerobic fitness was assessed by the 20-meter shuttle run using the FITNESSGRAMR criteria. Waist was measured in a subsample of 1,933 boys and 1,897 girls. Overweight, obesity and excess fat were defined according to the International Obesity Task Force (IOTF) or FITNESSGRAMR criteria. Results: 38.5% of boys and 46.5% of girls were considered as unfit according to the FITNESSGRAMR criteria. In boys, the area under the ROC curve (AUC) and 95% confidence interval were 66.7 (64.1 - 69.3), 67.1 (64.5 - 69.6) and 64.6 (61.9 - 67.2) for BMI, BF and waist, respectively (P<0.02). In girls, the values were 68.3 (65.9 - 70.8), 63.8 (61.3 - 66.3) and 65.9 (63.4 - 68.4), respectively (P<0.001). In boys, the sensitivity and specificity to diagnose low fitness were 13% and 99% for obesity (IOTF); 38% and 86% for overweight + obesity (IOTF); 28% and 94% for obesity (FITNESSGRAMR) and 42% and 81% for excess fat (FITNESSGRAMR). For girls, the values were 9% and 99% for obesity (IOTF); 33% and 82% for overweight + obesity (IOTF); 22% and 94% for obesity (FITNESSGRAMR) and 26% and 90% for excess fat (FITNESSGRAMR). Conclusions: BMI, not body fat or waist, should be used to define low aerobic fitness. The IOTF BMI cut-points to define obesity have a very low screening capacity and should not be used.
Resumo:
A rigorous unit operation model is developed for vapor membrane separation. The new model is able to describe temperature, pressure, and concentration dependent permeation as wellreal fluid effects in vapor and gas separation with hydrocarbon selective rubbery polymeric membranes. The permeation through the membrane is described by a separate treatment of sorption and diffusion within the membrane. The chemical engineering thermodynamics is used to describe the equilibrium sorption of vapors and gases in rubbery membranes with equation of state models for polymeric systems. Also a new modification of the UNIFAC model is proposed for this purpose. Various thermodynamic models are extensively compared in order to verify the models' ability to predict and correlate experimental vapor-liquid equilibrium data. The penetrant transport through the selective layer of the membrane is described with the generalized Maxwell-Stefan equations, which are able to account for thebulk flux contribution as well as the diffusive coupling effect. A method is described to compute and correlate binary penetrant¿membrane diffusion coefficients from the experimental permeability coefficients at different temperatures and pressures. A fluid flow model for spiral-wound modules is derived from the conservation equation of mass, momentum, and energy. The conservation equations are presented in a discretized form by using the control volume approach. A combination of the permeation model and the fluid flow model yields the desired rigorous model for vapor membrane separation. The model is implemented into an inhouse process simulator and so vapor membrane separation may be evaluated as an integralpart of a process flowsheet.
Resumo:
Gas-liquid mass transfer is an important issue in the design and operation of many chemical unit operations. Despite its importance, the evaluation of gas-liquid mass transfer is not straightforward due to the complex nature of the phenomena involved. In this thesis gas-liquid mass transfer was evaluated in three different gas-liquid reactors in a traditional way by measuring the volumetric mass transfer coefficient (kLa). The studied reactors were a bubble column with a T-junction two-phase nozzle for gas dispersion, an industrial scale bubble column reactor for the oxidation of tetrahydroanthrahydroquinone and a concurrent downflow structured bed.The main drawback of this approach is that the obtained correlations give only the average volumetric mass transfer coefficient, which is dependent on average conditions. Moreover, the obtained correlations are valid only for the studied geometry and for the chemical system used in the measurements. In principle, a more fundamental approach is to estimate the interfacial area available for mass transfer from bubble size distributions obtained by solution of population balance equations. This approach has been used in this thesis by developing a population balance model for a bubble column together with phenomenological models for bubble breakage and coalescence. The parameters of the bubble breakage rate and coalescence rate models were estimated by comparing the measured and calculated bubble sizes. The coalescence models always have at least one experimental parameter. This is because the bubble coalescence depends on liquid composition in a way which is difficult to evaluate using known physical properties. The coalescence properties of some model solutions were evaluated by measuring the time that a bubble rests at the free liquid-gas interface before coalescing (the so-calledpersistence time or rest time). The measured persistence times range from 10 msup to 15 s depending on the solution. The coalescence was never found to be instantaneous. The bubble oscillates up and down at the interface at least a coupleof times before coalescence takes place. The measured persistence times were compared to coalescence times obtained by parameter fitting using measured bubble size distributions in a bubble column and a bubble column population balance model. For short persistence times, the persistence and coalescence times are in good agreement. For longer persistence times, however, the persistence times are at least an order of magnitude longer than the corresponding coalescence times from parameter fitting. This discrepancy may be attributed to the uncertainties concerning the estimation of energy dissipation rates, collision rates and mechanisms and contact times of the bubbles.