939 resultados para Abies, cone scales
Resumo:
AIM: To compare intraoral occlusal (OC) and periapical (PA) radiographs vs. limited cone beam computed tomography (CBCT) in diagnosing root-fractured permanent teeth. MATERIAL AND METHODS: In 38 patients (mean age 24 years, range 8-52 years) with 44 permanent teeth with horizontal root fractures, intraoral radiographs (PA and OC) and limited CBCT were used to evaluate the location (apical, middle, cervical third of the root) and angulation of the fracture line. Furthermore, the conventional radiographs and CBCT images were compared for concordance of fracture location. RESULTS: In the PA and OC radiographs, 28 fractures (63.6%) were located in the middle third of the root, 11 (25.0%) in the apical third and 5 (11.4%) in the cervical third. The PA/OC radiographs and the sagittal CBCT images (facial aspect) yielded the same level of root fracture in 70.5% of cases (31 teeth; 95% CI: 54.1-82.7%). The PA/OC radiographs and sagittal CBCT images (palatal aspect) showed the same level of root fracture in 31.8% of cases. There was a statistically significant association between the angle at which the root fracture line intersected the axis of the tooth and the level of root fracture in the facial aspect of the sagittal CBCT images. CONCLUSIONS: The diagnosis of the location and angulation of root fractures based on limited CBCT imaging differs significantly from diagnostic procedures based on intraoral radiographs (PA/OC) alone. The clinical significance for treatment strategies and for the prognosis of root-fractured teeth has to be addressed in future studies.
Resumo:
The aim of this study was to evaluate whether measurements performed on conventional frontal radiographs are comparable to measurements performed on three-dimensional (3D) models of human skulls derived from cone beam computed tomography (CBCT) scans and if the latter can be used in longitudinal studies. Cone beam computed tomography scans and conventional frontal cephalometric radiographs were made of 40 dry human skulls. From the CBCT scan a 3D model was constructed. Standard cephalometric software was used to identify landmarks and to calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs, and on all images, five times with a time interval of 1 wk. Intra-observer reliability was acceptable for all measurements. There was a statistically significant and clinically relevant difference between measurements performed on conventional frontal radiographs and on 3D CBCT-derived models of the same skull. There was a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements performed on 3D models constructed from CBCT scans. We therefore recommend that 3D models should not be used for longitudinal research in cases where there are only two-dimensional (2D) records from the past.
Resumo:
This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks and calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs on all Images 5 times with a time-interval of 1 week. Intra-observer reliability was acceptable for all measurements. The reproducibility of the measurements on the frontal radiographs obtained from the CBCT scans was higher than those on conventional frontal radiographs. There is a statistically significant and clinically relevant difference between measurements on conventional and constructed frontal radiographs. There is a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements on frontal cephalometric radiographs constructed from CBCT scans, owing to different positioning of patients in both devices. Positioning of the patient in the CBCT device appears to be an important factor in cases where a 2D projection of the 3D scan is made.
Resumo:
Abies alba (fir), a submontane tree from Central European mountains and uplands, is of special interest for palaeoecological and palaeoclimate interpretations due to its sensitivity to air and soil humidity. Its present distribution limit in the uplands of SE Poland is still a matter of debate. In the Holocene fir expanded to Poland very late, but early fir populations are supposed to occur in the Šumava Mts (Czech Republic). The study aims: to estimate pollen thresholds for fir presence/absence in Bohemia (Czech Republic) and Poland on the basis of modified Tauber pollen traps; to use these thresholds for tracing fir presence in two pollen diagrams from Poland (Słone and Bezedna lakes) in the border zone between the Roztocze region (with fir forest stands today) and Polesie (where fir has never played an important role); and to investigate how the percentage presence/absence threshold can be used to trace the occurrence and abundance of fir trees in the Šumava Mts based on the pollen diagrams of Rokytecká slat' and Mrtvý luh. The fir pollen thresholds estimated in terms of PAR (pollen accumulation rates or pollen influx) range from 843 (grains cm− 2 year− 1) (Roztocze) to 61 (Krkonoše) and 49 (Šumava). Percentage thresholds range from 0.3% in Krkonoše where fir trees are not present within 4 km to 22% in fir-dominated woodland of the Roztocze, providing evidence of strong underrepresentation of fir in the pollen deposition. Application of these percentage thresholds to the Słone and Bezedna pollen diagrams indicates that occurrence of fir in the region is possible from 3.5 cal ky BP onwards, though the evidence is not decisive. In the Šumava, a low representation of fir pollen (1–2%) reflecting presence of scattered fir trees was detected as early as ca. 7.0 cal ky BP.
Resumo:
PURPOSE The purpose of the present study was to evaluate the thickness and anatomic characteristics of the sinus membrane using cone beam computed tomography (CBCT) in patients evaluated for implant surgery in the posterior maxilla. MATERIALS AND METHODS The study included 131 consecutive patients referred for dental implant placement in the posterior maxilla. A total of 138 CBCT images was obtained using fields of view of 4 × 4 cm, 6 × 6 cm, or 8 × 8 cm. Reformatted sagittal CBCT slices were analyzed with regard to the thickness and characteristics of the sinus membrane at single-tooth gaps in the posterior maxilla. Factors that might influence the dimensions of the sinus membrane, such as age, sex, endodontic status, and the season, were analyzed. RESULTS The mean thickness of the maxillary sinus mucosa varied between 2.1 and 2.69 mm in the three locations analyzed. Fewer than half of the evaluated sinuses exhibited a healthy mucosa (49 of 138, or 35.51%). Most of the pathologic findings were flat, shallow thickenings (63 of 138, or 45.65%). Sex did not influence the thickness of the sinus membrane at the root tips of the premolars or at single-tooth gaps, but there was a statistically significant correlation in the region of the maxillary molars. No other evaluated factors had a statistically significant effect on the dimensions of the antral mucosa. CONCLUSIONS In the present study, sex was the only factor influencing the dimension of the sinus membrane, whereas patient age, season, and the endodontic status of neighboring teeth had no significant effect on the thickness of the antral mucosa. Future studies should address which types of mucosal thickening require interdisciplinary therapy.
Resumo:
Structural and functional connectivity are intrinsic properties of the human brain and represent the amount of cognitive capacities of individual subjects. These connections are modulated due to development, learning, and disease. Momentary adaptations in functional connectivity alter the structural connections, which in turn affect the functional connectivity. Thus, structural and functional connectivity interact on a broad timescale. In this study, we aimed to explore distinct measures of connectivity assessed by functional magnetic resonance imaging and diffusion tensor imaging and their association to the dominant electroencephalogram oscillatory property at rest: the individual alpha frequency (IAF). We found that in 21 healthy young subjects, small intraindividual temporal IAF fluctuations were correlated to increased blood oxygenation level-dependent signal in brain areas associated to working memory functions and to the modulation of attention. These areas colocalized with functionally connected networks supporting the respective functions. Furthermore, subjects with higher IAF show increased fractional anisotropy values in fascicles connecting the above-mentioned areas and networks. Hence, due to a multimodal approach a consistent functionally and structurally connected network related to IAF was observed.
Resumo:
Delivering cochlear implants through a minimally invasive tunnel (1.8 mm in diameter) from the mastoid surface to the inner ear is referred to as direct cochlear access (DCA). Based on cone beam as well as micro-computed tomography imaging, this in vitro study evaluates the feasibility and efficacy of manual cochlear electrode array insertions via DCA. Free-fitting electrode arrays were inserted in 8 temporal bone specimens with previously drilled DCA tunnels. The insertion depth angle, procedural time, tunnel alignment as well as the inserted scala and intracochlear trauma were assessed. Seven of the 8 insertions were full insertions, with insertion depth angles higher than 520°. Three cases of atraumatic scala tympani insertion, 3 cases of probable basilar membrane rupture and 1 case of dislocation into the scala vestibuli were observed (1 specimen was damaged during extraction). Manual electrode array insertion following a DCA procedure seems to be feasible and safe and is a further step toward clinical application of image-guided otological microsurgery.
Resumo:
The study analyses the location of impacted maxillary canines and factors influencing root resorptions of adjacent teeth using cone-beam computed tomography (CBCT). In addition, the interrater reliability between observers of two different dental specialties for radiographic parameters will be evaluated. CBCT images of patients who were referred for radiographic localization of impacted maxillary canines and/or suspicion of root resorptions of adjacent teeth were included. The study analysed the exact three-dimensional location of the impacted canines in the anterior maxilla, frequency and extent of root resorptions, and potential influencing factors. To assess interrater agreement, Cohen's correlation parameters were calculated. This study comprises 113 patients with CBCT scans, and 134 impacted canines were analysed retrospectively. In the patients evaluated, 69 impacted canines were located palatally (51.49 per cent), 41 labially (30.60 per cent), and 24 (17.91 per cent) in the middle of the alveolar process. Root resorptions were found in 34 lateral incisors (25.37 per cent), 7 central incisors (5.22 per cent), 6 first premolars (4.48 per cent), and 1 second premolar (0.75 per cent). There was a significant correlation between root resorptions on adjacent teeth and localization of the impacted canine in relation to the bone, as well as vertical localization of the canine. Interrater agreement showed values of 0.546-0.877. CBCT provides accurate information about location of the impacted canine and prevalence and degree of root resorption of neighbouring teeth with high interrater correlation. This information is of great importance for surgeons and orthodontists for accurate diagnostics and interdisciplinary treatment planning.
Resumo:
INTRODUCTION The aims of this study were to compare lateral cephalograms with other radiologic methods for diagnosing suspected fusions of the cervical spine and to validate the assessment of congenital fusions and osteoarthritic changes against the anatomic truth. METHODS Four cadaver heads were selected with fusion of vertebrae C2 and C3 seen on a lateral cephalogram. Multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) were performed and assessed by 5 general radiologists and 5 oral radiologists, respectively. Vertebrae C2 and C3 were examined for osseous fusions, and the left and right facet joints were diagnosed for osteoarthritis. Subsequently, the C2 and C3 were macerated and appraised by a pathologist. Descriptive analysis was performed, and interrater agreements between and within the groups were computed. RESULTS All macerated specimens showed osteoarthritic findings of varying degrees, but no congenital bony fusion. All observers agreed that no fusion was found on MDCT or CBCT. They disagreed on the prevalence of osteoarthritic deformities (general radiologists/MDCT, 100%; oral radiologists/CBCT, 93.3%) and joint space assessment in the facet joints (kappa = 0.452). The agreement within the rater groups differed considerably (general radiologists/MDCT, kappa = 0.612; oral radiologists/CBCT, kappa = 0.240). CONCLUSIONS Lateral cephalograms do not provide dependable data to assess the cervical spine for fusions and cause false-positive detections. Both MDCT interpreted by general radiologists and CBCT interpreted by oral radiologists are reliable methods to exclude potential fusions. Degenerative osteoarthritic changes are diagnosed more accurately and consistently by general radiologists evaluating MDCT.
Resumo:
Lucid dream and nightmare frequencies vary greatly between individuals and to assess these differences reliable instruments are needed. The present study aimed to examine the reliability of eight-point scales for measuring lucid dream and nightmare frequencies. The scales were administered twice (with a four-week interval) to 93 sport students. A re-test reliability for the lucid dream frequency was found r=.89 (p<.001) and for the nightmare frequency r=.75 (p<.001). Both eight-point scales appear to be reliable measures for assessing individual differences in lucid dream and nightmare frequencies.
Resumo:
INTRODUCTION The mental foramen (MF) is an important landmark in dentistry. Knowledge of its position is central to perform block anesthesia of the mental nerve or to avoid nerve damage during surgical procedures in the premolar area of the mandible. The present radiographic study aimed at evaluating the location and dimension of the MF and measuring distances to neighboring structures by using limited cone-beam computed tomography (CBCT). METHODS Sagittal, axial, and coronal CBCT images of 142 patients (26 bilateral and 116 unilateral cases) were retrospectively screened to determine the location of the MF with respect to adjacent teeth and to take linear measurements of the size of the MF and its distances to the upper and lower borders of the mandible. In addition, the course and angulation of the mental canal exiting the MF were assessed. RESULTS The majority of MF (56%) were located apically between the 2 premolars, and another 35.7% of MF were positioned below the second premolar. On average, the MF was localized 5.0 mm from the closest root of the adjacent tooth (range, 0.3-9.8 mm). The mean size of the MF showed a height of 3.0 mm and a length of 3.2 mm; however, individual cases showed large differences in height (1.8-5.1 mm) and in length (1.8-5.5 mm). All mental canals exiting the MF demonstrated an upward course in the coronal plane, with 70.1% of the mental canal presenting an anterior loop (AL) in the axial view. The mean extension of AL in cases with an AL was 2.3 mm. CONCLUSIONS This study is consistent with previous radiographic studies regarding size and location of MF and distances between MF and adjacent anatomic structures. The assessed bilateral cases showed a high intraindividual concordance for certain features when comparing right and left sides.
Resumo:
Since the introduction of cone beam computed tomography (CBCT), this 3-dimensional diagnostic imaging technique has been established in a growing number of fields in dental medicine. It has become an important tool for both diagnosis and treatment planning, and is also able to support endodontic treatments. However, the higher effective dose of ionizing radiation compared to conventional 2-dimensional radiographs is not justifiable in every case. CBCT allows for a more precise diagnosis of periapical lesions, root fractures as well as external and internal resorptions. Concerning the utility of CBCT in treatment planning decisions, the gain of information through 3-dimensional imaging for any of these pathologies has to be evaluated carefully on an individual basis. Moreover, radioopaque materials such as root canal filling and posts often create artefacts, which may compromise diagnosis. The aim of this review is to summarize the possibilities and limits of CBCT imaging in endodontology as well as introduce guidelines for daily clinical practice. Furthermore, the article presents possible therapeutic advantages of preexisting CBCT scans for root canal treatments.