886 resultados para 030106 Quality Assurance Chemometrics Traceability and Metrological Chemistry
Resumo:
Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.
Resumo:
We recently reported on the Multi Wave Animator (MWA), a novel open-source tool with capability of recreating continuous physiologic signals from archived numerical data and presenting them as they appeared on the patient monitor. In this report, we demonstrate for the first time the power of this technology in a real clinical case, an intraoperative cardiopulmonary arrest following reperfusion of a liver transplant graft. Using the MWA, we animated hemodynamic and ventilator data acquired before, during, and after cardiac arrest and resuscitation. This report is accompanied by an online video that shows the most critical phases of the cardiac arrest and resuscitation and provides a basis for analysis and discussion. This video is extracted from a 33-min, uninterrupted video of cardiac arrest and resuscitation, which is available online. The unique strength of MWA, its capability to accurately present discrete and continuous data in a format familiar to clinicians, allowed us this rare glimpse into events leading to an intraoperative cardiac arrest. Because of the ability to recreate and replay clinical events, this tool should be of great interest to medical educators, researchers, and clinicians involved in quality assurance and patient safety.
Resumo:
The purpose of this article is to compare quality of life (QOL) and menopausal symptoms among premenopausal patients with lymph node-negative breast cancer receiving chemotherapy, goserelin, or their sequential combination, and to investigate differential effects by age.
Resumo:
Point-of-care testing (POCT) remains under scrutiny by healthcare professionals because of its ill-tried, young history. POCT methods are being developed by a few major equipment companies based on rapid progress in informatics and nanotechnology. Issues as POCT quality control, comparability with standard laboratory procedures, standardisation, traceability and round robin testing are being left to hospitals. As a result, the clinical and operational benefits of POCT were first evident for patients on the operating table. For the management of cardiovascular surgery patients, POCT technology is an indispensable aid. Improvement of the technology has meant that clinical laboratory pathologists now recognise the need for POCT beyond their high-throughput areas.
Resumo:
In climate research the interest on carbonaceous particles has increased over the last years because of their influence on the radiation balance of the earth. Nevertheless, there is a paucity of available data regarding their concentrations and sources in the past. Such data would be important for a better understanding of their effects and for estimating their influence on future climate. Here, a technique is described to extract carbonaceous particles from ice core samples with subsequent separation of the two main constituents into organic carbon (OC) and elemental carbon (EC) for analysis of their concentrations in the past. This is combined with further analysis of OC and EC 14C/12C ratios by accelerator mass spectrometry (AMS), what can be used for source apportionment studies of past emissions. We further present how 14C analysis of the OC fraction could be used in the future to date any ice core extracted from a high-elevation glacier. Described sample preparation steps to final analysis include the combustion of micrograms of water–insoluble carbonaceous particles, primary collected by filtration of melted ice samples, the graphitisation of the obtained CO2 to solid AMS target material and final AMS measurements. Possible fractionation processes were investigated for quality assurance. Procedural blanks were reproducible and resulted in carbon masses of 1.3 ± 0.6 μg OC and 0.3 ± 0.1 μg EC per filter. The determined fraction of modern carbon (fM) for the OC blank was 0.61 ± 0.13. The analysis of processed IAEA-C6 and IAEA-C7 reference material resulted in fM = 1.521 ± 0.011 and δ13C = −10.85 ± 0.19‰, and fM = 0.505 ± 0.011 and δ13C = −14.21 ± 0.19‰, respectively, in agreement with consensus values. Initial carbon contents were thereby recovered with an average yield of 93%.
Resumo:
With energy demands and costs growing every day, the need for improving energy efficiency in electrical devices has become very important. Research into various methods of improving efficiency for all electrical components will be a key to meet future energy needs. This report documents the design, construction, and testing of a research quality electric machine dynamometer and test bed. This test cell system can be used for research in several areas including: electric drives systems, electric vehicle propulsion systems, power electronic converters, load/source element in an AC Microgrid, as well as many others. The test cell design criteria, and decisions, will be discussed in reference to user functionality and flexibility. The individual power components will be discussed in detail to how they relate to the project, highlighting any feature used in operation of the test cell. A project timeline will be discussed, clearly stating the work done by the different individuals involved in the project. In addition, the system will be parameterized and benchmark data will be used to provide the functional operation of the system. With energy demands and costs growing every day, the need for improving energy efficiency in electrical devices has become very important. Research into various methods of improving efficiency for all electrical components will be a key to meet future energy needs. This report documents the design, construction, and testing of a research quality electric machine dynamometer and test bed. This test cell system can be used for research in several areas including: electric drives systems, electric vehicle propulsion systems, power electronic converters, load/source element in an AC Microgrid, as well as many others. The test cell design criteria, and decisions, will be discussed in reference to user functionality and flexibility. The individual power components will be discussed in detail to how they relate to the project, highlighting any feature used in operation of the test cell. A project timeline will be discussed, clearly stating the work done by the different individuals involved in the project. In addition, the system will be parameterized and benchmark data will be used to provide the functional operation of the system.
Resumo:
BACKGROUND: Outcome after lung transplantation (LTx) is affected by the onset of bronchiolitis obliterans syndrome (BOS) and lung function decline. Reduced health-related quality of life (HRQL) and physical mobility have been shown in patients developing BOS, but the impact on the capacity to walk is unknown. We aimed to compare the long-term HRQL and 6-minute walk test (6MWT) between lung recipients affected or not by BOS Grade > or =2. METHODS: Fifty-eight patients were prospectively followed for 5.6 +/- 2.9 years after LTx. Assessments included the St George's Respiratory Questionnaire (SGRQ) and the 6MWT, which were performed yearly. Moreover, clinical complications were recorded to estimate the proportion of the follow-up time lived without clinical intercurrences after transplant. Analyses were performed using adjusted linear regression and repeated-measures analysis of variance. RESULTS: BOS was a significant predictor of lower SGRQ scores (p < 0.01) and reduced time free of clinical complications (p = 0.001), but not of 6MWT distance (p = 0.12). At 7 years post-transplant, results were: 69.0 +/- 21.8% vs 86.9 +/- 5.6%, p < 0.05 (SGRQ); 58.5 +/- 21.6% vs 88.7 +/- 11.4%, p < 0.01 (proportion of time lived without clinical complications); and 82.2 +/- 10.9% vs 91.9 +/- 14.2%, p = 0.27 (percent of predicted 6MWT), respectively, for patients with BOS and without BOS. CONCLUSIONS: Despite significantly less time lived without clinical complications and progressive decline of self-reported health status, the capacity to walk of patients affected by BOS remained relatively stable over time. These findings may indicate that the development of moderate to severe BOS does not prevent lung recipients from walking independently and pursuing an autonomous life.
Resumo:
Iron ore is one of the most important ores in the world. Over the past century, most mining of iron ore has been focused on magnetite (Fe3O4). As the name suggests, magnetite is magnetic in nature and is easily separated from gangue (unwanted) minerals through magnetic separation processes. Unfortunately, the magnetite ore bodies are diminishing. Because of this, there has been a recent drive to pursue technology that can economically separate hematite (Fe2O3) from its gangue minerals as hematite is a much more abundant source of iron. Most hematite ore has a very small liberation size that is frequently less than 25μm. Beneficiation of any ore with this fine of a liberation size requires advanced processing methods and is seldom pursued. A single process, known as selective flocculation and dispersion, has been successfully implemented at a plant scale for the beneficiation of fine liberation size hematite ore. Very little is known about this process as it was discovered by the U.S. Bureau of Mines by accident. The process is driven by water chemistry and surface chemistry modifications that enhance the separation of the hematite from its gangue minerals. This dissertation focuses on the role of water chemistry and process reagents in this hematite beneficiation process. It has been shown that certain ions, including calcium and magnesium, play a significant role in the process. These ions have a significant effect on the surface chemistry as reported by zeta potential studies. It was shown that magnesium ions within the process water have a more significant impact on surface chemistry than calcium ions due to steric hindrance effects at the hematite surface. It has also been shown that polyacrylic acid dispersants, if used in the process, can increase product quality (increase iron content, decrease phosphorus content, decrease silica content) substantially. Water, surface and reagent chemistry experiments were performed at a laboratory, pilot, and full plant scale during the course of this work. Many of the conclusions developed in the laboratory and pilot scale were found to be true at the full plant scale as well. These studies are the first published in history to develop theories of water chemistry and surface chemistry interactions at a full plant scale.
Resumo:
BACKGROUND: Psychological distress, poor disease-specific quality of life (QoL), and reduction in vagally mediated early heart rate recovery (HRR) after exercise, all previously predicted morbidity and mortality in patients with chronic heart failure (CHF). We hypothesized lower HRR with greater psychological distress and poorer QoL in CHF. DESIGN: All assessments were made at the beginning of a comprehensive cardiac outpatient rehabilitation intervention program. METHODS: Fifty-six CHF patients (mean 58+/-12 years, 84% men) completed the Hospital Anxiety and Depression Scale and the Minnesota Living With Heart Failure Questionnaire. HRR was determined as the difference between HR at the end of exercise and 1 min after exercise termination (HRR-1). RESULTS: Elevated levels of anxiety symptoms (P=0.005) as well as decreased levels of the Minnesota Living With Heart Failure Questionnaire total (P = 0.025), physical (P=0.026), and emotional (P=0.017) QoL were independently associated with blunted HRR-1. Anxiety, total, physical, and emotional QoL explained 11.4, 8, 7.8, and 9.0%, respectively, of the variance after controlling for covariates. Depressed mood was not associated with HRR-1 (P=0.20). CONCLUSION: Increased psychological distress with regard to elevated anxiety symptoms and impaired QoL were independent correlates of reduced HRR-1 in patients with CHF. Reduced vagal tone might explain part of the adverse clinical outcome previously observed in CHF patients in relation to psychological distress and poor disease-specific QoL.
Resumo:
The feature of this paper is a critical assessment of the current discourses about quality of life (QoL) and their implications for Social Work. At first it pictures some major historical backgrounds of the discussion on the improvement of life quality as an aim of societal development. In particular three crucial shifts in the politics of QoL - its 'individualisation', its 'informalisation' and its 'culturalisation' - and their implications for Social Work are critically examined theoretically and empirically referring to the results of an own community-study. The paper concludes with an alternative suggestion reflecting the idea of an 'autonomy-based' approach of democratic equality.
Resumo:
Screening for malignant disease aims to reduce the population risk of impaired health due to the tumor in question. Screening does not only entail testing but covers all steps required to achieve the intended reduction in risk, from the appropriate information of the population to a suitable therapy. Screening tests are performed in individuals free or unaware of any symptoms associated with the tumor. An essential condition is a recognizable pathological abnormality, which occurs without symptoms and represents a pre-clinical, early stage of the tumor. Overdiagnosis and overtreatment have only recently been recognized as important problems of screening for malignant disease. Overdiagnosis is defined as a screening-detected tumor that would never have led to symptoms. In prostate-specific antigen (PSA) screening for prostate cancer 50 % - 70 % of screening-detected cancers represent such overdiagnoses. Similarly, in the case of mammography screening 20 % - 30 % of screening-detected breast cancers are overdiagnoses. The evaluation of screening interventions is often affected by biases such as healthy screenee effects or length and lead time bias. Randomized controlled trials are therefore needed to examine the efficacy and effectiveness of screening interventions and to define the rate of adverse outcomes such as unnecessary diagnostic evaluations, overdiagnosis and overtreatment. Unfortunately there is no independent Swiss body comparable to the National Screening Committee in the United Kingdom or the United States Preventive Services Task Force, which examines screening tests and programs and develops recommendations. Clearly defined goals, a central organization responsible for inviting eligible individuals, documentation and quality assurance and balanced information of the public are important attributes of successful screening programs. In Switzerland the establishment of such programs is hampered by the highly fragmented, Federal health system which allows patients to access specialists directly.
Resumo:
Wireless mobile sensor networks are enlarging the Internet of Things (IoT) portfolio with a huge number of multimedia services for smart cities. Safety and environmental monitoring multimedia applications will be part of the Smart IoT systems, which aim to reduce emergency response time, while also predicting hazardous events. In these mobile and dynamic (possible disaster) scenarios, opportunistic routing allows routing decisions in a completely distributed manner, by using a hop- by-hop route decision based on protocol-specific characteristics, and a predefined end-to-end path is not a reliable solution. This enables the transmission of video flows of a monitored area/object with Quality of Experience (QoE) support to users, headquarters or IoT platforms. However, existing approaches rely on a single metric to make the candidate selection rule, including link quality or geographic information, which causes a high packet loss rate, and reduces the video perception from the human standpoint. This article proposes a cross-layer Link quality and Geographical-aware Opportunistic routing protocol (LinGO), which is designed for video dissemination in mobile multimedia IoT environments. LinGO improves routing decisions using multiple metrics, including link quality, geographic loca- tion, and energy. The simulation results show the benefits of LinGO compared with well-known routing solutions for video transmission with QoE support in mobile scenarios.
Resumo:
Radiocarbon analysis of the carbonaceous aerosol allows an apportionment of fossil and non-fossil sources of airborne particulate matter (PM). A chemical separation of total carbon (TC) into its subfractions organic carbon (OC) and elemental carbon (EC) refines this powerful technique, as OC and EC originate from different sources and undergo different processes in the atmosphere. Although C-14 analysis of TC, EC, and OC has recently gained increasing attention, interlaboratory quality assurance measures have largely been missing, especially for the isolation of EC and OC. In this work, we present results from an intercomparison of 9 laboratories for C-14 analysis of carbonaceous aerosol samples on quartz fiber filters. Two ambient PM samples and 1 reference material (RM 8785) were provided with representative filter blanks. All laboratories performed C-14 determinations of TC and a subset of isolated EC and OC for isotopic measurement. In general, C-14 measurements of TC and OC agreed acceptably well between the laboratories, i.e. for TC within 0.015-0.025 (FC)-C-14 for the ambient filters and within 0.041 (FC)-C-14 for RM 8785. Due to inhomogeneous filter loading, RM 8785 demonstrated only limited applicability as a reference material for C-14 analysis of carbonaceous aerosols. C-14 analysis of EC revealed a large deviation between the laboratories of 28-79 as a consequence of different separation techniques. This result indicates a need for further discussion on optimal methods of EC isolation for C-14 analysis and a second stage of this intercomparison.
Resumo:
The RPC developed a new phantom to ensure comparable and consistent radiation administration in spinal radiosurgery clinical trials. This study assessed the phantom’s dosimetric and anatomic utility. The ‘spine phantom’ is a water filled thorax with anatomy encountered in spinal radiosurgery: target volume, vertebral column, spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. Four irradiations were administered: a four angle box plan, a seven angle conformal plan, a seven angle IMRT plan, and a nine angle IMRT plan (denoted as IMRT plan #1 and plan #2, respectively). In each plan, at least 95% of the defined tumor volume received 8 Gy. For each irradiation the planned and administered dose distributions were registered via pinpricks, and compared using point dose measurements, dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in the qualitative assessments and exceeded the 95% passing rate at the 5% / 3 mm criteria, except IMRT plan #1, which was determined to have been poorly localized during treatment administration. The measured and planned dose distributions demonstrated acceptable agreement at the 5% / 3 mm criteria, and the spine phantom was determined to be a useful tool for the remote assessment of an institution’s treatment planning and dose delivery regimen.