893 resultados para ventricular assist device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The mechanism behind early graft failure after right ventricular outflow tract (RVOT) reconstruction is not fully understood. Our aim was to establish a three-dimensional computational fluid dynamics (CFD) model of RVOT to investigate the hemodynamic conditions that may trigger the development of intimal hyperplasia and arteriosclerosis. METHODS: Pressure, flow, and diameter at the RVOT, pulmonary artery (PA), bifurcation of the PA, and left and right PAs were measured in 10 normal pigs with a mean weight of 24.8 ± 0.78 kg. Data obtained from the experimental scenario were used for CFD simulation of pressure, flow, and shear stress profile from the RVOT to the left and right PAs. RESULTS: Using experimental data, a CFD model was obtained for 2.0 and 2.5-L/min pulsatile inflow profiles. In both velocity profiles, time and space averaged in the low-shear stress profile range from 0-6.0 Pa at the pulmonary trunk, its bifurcation, and at the openings of both PAs. These low-shear stress areas were accompanied to high-pressure regions 14.0-20.0 mm Hg (1866.2-2666 Pa). Flow analysis revealed a turbulent flow at the PA bifurcation and ostia of both PAs. CONCLUSIONS: Identified local low-shear stress, high pressure, and turbulent flow correspond to a well-defined trigger pattern for the development of intimal hyperplasia and arteriosclerosis. As such, this real-time three-dimensional CFD model may in the future serve as a tool for the planning of RVOT reconstruction, its analysis, and prediction of outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parastomal hernia (PSH) is the most frequent long-term stoma complication with serious negative effects on quality of life. Surgical revision is often required and has a substantial morbidity and recurrence rate. The development of PSH requires revisional surgery with a substantial perioperative morbidity and high failure rate in the long-term follow-up. Prophylactic parastomal mesh insertion during stoma creation has the potential to reduce the rate of PSH, but carries the risk of early and late mesh-related complications such as infection, fibrosis, mesh shrinkage, and/or bowel erosion. We developed a new stomaplasty ring (KORING), which is easy to implant, avoids potential mesh-related complications, and has a high potential of long-term prevention of PSH. Here we describe the technique and the first use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CORBA (Common Object Request Broker Architecture) on laajalle levinnyt ja teollisuudessa yleisesti käytetty hajautetun tietojenkäsittelyn arkkitehtuuri. CORBA skaalautuu eri kokoisiin tarpeisiin ja sitä voidaan hyödynntää myös sulautetuissa langattomissa laitteissa. Oleellista sulautetussa ympäristössä on rakentaa rajapinnat kevytrakenteisiksi, pysyviksi ja helposti laajennettaviksi ilman että yhteensopivuus aikaisempiin rajapintoihin olisi vaarassa. Langattomissa laitteissa resurssit, kuten muistin määrä ja prosessointiteho, ovat hyvin rajalliset, joten rajapinta tulee suunnitella ja toteuttaa optimaalisesti. Palveluiden tulee ottaa huomioon myös langattomuuden rajoitukset, kuten hitaat tiedonsiirtonopeudet ja tiedonsiirron yhteydettömän luonteen. Työssä suunniteltiin ja toteutettiin CORBA-rajapinta GSM-päätelaitteeseen, jonka on todettu täyttävän sille asetetut tavoitteet. Rajapinta tarjoaa kaikki yleisimmät GSM-terminaalin ominaisuudet ja on laajennettavissa tulevia tuotteita ja verkkotekniikoita varten. Laajennettavuutta saavutetaan esimerkiksi kuvaamalla terminaalin ominaisuudet yleisellä kuvauskielellä, kuten XML:lla (Extensible Markup Language).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The aim of our study was to compare traumatic injuries observed after cardiopulmonary resuscitation (CPR) by means of standard (manual) or assisted (mechanical) chest compression by Lund University Cardiopulmonary Assist System, 2nd generation (LUCAS?2) device. METHODS: A retrospective study was conducted including cases from 2011 to 2013, analysing consecutive autopsy reports in two groups of patients who underwent medicolegal autopsy after unsuccessful CPR. We focused on traumatic injuries from dermal to internal trauma, collecting data according to a standardised protocol. RESULTS: The study group was comprised of 26 cases, while 32 cases were included in the control group. Cardiopulmonary resuscitation performed by LUCAS?2 was longer than manual CPR performed in control cases (study group: mean duration 51.5 min; controls 29.4 min; p = 0.004). Anterior chest lesions (from bruises to abrasions) were described in 18/26 patients in the LUCAS?2 group and in 6/32 of the control group. A mean of 6.6 rib fractures per case was observed in the LUCAS?2 group, but this was only 3.1 in the control group (p = 0.007). Rib fractures were less frequently observed in younger patients. The frequency of sternal factures was similar in both groups. A few trauma injuries to internal organs (mainly cardiac, pulmonary and hepatic bruises), and some petechiae (study 46 %; control 41 %; p = 0.79) were recorded in both groups. CONCLUSION: LUCAS?2-CPR is associated with more rib fractures than standard CPR. Typical round concentric skin lesions were observed in cases of mechanical reanimation. No life-threatening injuries were reported. Petechiae were common findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Repair of the right ventricular outflow tract (RVOT) in paediatric cardiac surgery remains challenging due to the high reoperation rate. Intimal hyperplasia and consequent arteriosclerosis is one of the most important limitation factors for graft durability. Since local shear stress and pressure are predictive elements for intimal hyperplasia and wall degeneration, we sought to determine in an oversized 12-mm RVOT model, with computed fluid dynamics simulation, the local haemodynamical factors that may explain intimal hyperplasia. This was done with the aim of identifying the optimal degree of oversizing for a 12-mm native RVOT. METHODS: Twenty domestic pigs, with a weight of 24.6 ± 0.89 kg and a native RVOT diameter of 12 ± 1.7 mm, had valve conduits of 12, 16, 18 and 20 mm implanted. Pressure and flow were measured at 75, 100 and 125% of normal flow at RVOT at the pulmonary artery, pulmonary artery bifurcation and at the left and right pulmonary arteries. Three-dimensional computed fluid dynamics (CFD) simulation in all four geometries in all flow modalities was performed. Local shear stress and pressure conditions were investigated. RESULTS: Corresponding to 75, 100 and 125% of steady-state flow, three inlet velocity profiles were obtained, 0.2, 0.29 and 0.36 m/s, respectively. At inflow velocity profiles, low shear stress areas, ranged from 0 to 2 Pa, combined with high-pressure areas ranging from 11.5 to 12.1 mmHg that were found at distal anastomosis, at bifurcation and at the ostia of the left and right pulmonary arteries in all geometries. CONCLUSIONS: In all three oversized geometries, the local reparation of shear stress and pressure in the 16-mm model showed a similar local profile as in the native 12 mm RVOT. According to these findings, we suggest oversizing the natural 12-mm RVOT by not more than 4 mm. The elements responsible for wall degeneration and intimal hyperplasia remain very similar to the conditions present in native RVOT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämä diplomityö käsittelee sääntöpohjaisen verkkoon pääsyn hallinnan (NAC) ratkaisuja arkkitehtonisesta näkökulmasta. Työssä käydään läpi Trusted Computing Groupin, Microsoft Corporationin, Juniper Networksin sekä Cisco Systemsin NAC-ratkaisuja. NAC koostuu joukosta uusia sekä jo olemassa olevia teknologioita, jotka auttavat ennalta määriteltyyn sääntökantaan perustuen hallitsemaan suojattuun verkkoon pyrkivien laitteiden tietoliikenneyhteyksiä. Käyttäjän tunnistamisen lisäksi NAC pystyy rajoittamaan verkkoon pääsyä laitekohtaisten ominaisuuksien perusteella, esimerkiksi virustunnisteisiin ja käyttöjärjestelmäpäivityksiin liittyen ja paikkaamaan tietyin rajoituksin näissä esiintyviä puutteita verkkoon pääsyn sallimiseksi. NAC on verraten uusi käsite, jolta puuttuu tarkka määritelmä. Tästä johtuen nykymarkkinoilla myydään ominaisuuksiltaan puutteellisia tuotteita NAC-nimikkeellä. Standardointi eri valmistajien NAC-komponenttien yhteentoimivuuden takaamiseksi on meneillään, minkä perusteella ratkaisut voidaan jakaa joko avoimia standardeja tai valmistajakohtaisia standardeja noudattaviksi. Esitellyt NAC-ratkaisut noudattavat standardeja joko rajoitetusti tai eivät lainkaan. Mikään läpikäydyistä ratkaisuista ei ole täydellinen NAC, mutta Juniper Networksin ratkaisu nousee niistä potentiaalisimmaksi jatkokehityksen ja -tutkimuksen kohteeksi TietoEnator Processing & Networks Oy:lle. Eräs keskeinen ongelma NAC-konseptissa on työaseman tietoverkolle toimittama mahdollisesti valheellinen tietoturvatarkistuksen tulos, minkä perusteella pääsyä osittain hallitaan. Muun muassa tähän ongelmaan ratkaisuna voisi olla jo nykytietokoneista löytyvä TPM-siru, mikä takaa tiedon oikeellisuuden ja koskemattomuuden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We described for the first time the amino acid substitutions conferring rifampicin resistance in eight Propionibacterium acnes strains isolated from patients with biofilm or device-related infections. We identified different mutations in cluster I and one mutation, never reported, in cluster II of the rpoB gene (I480V) associated with the most frequent one in cluster I (S442L). Half of the patients previously received treatment with rifampicin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to measure the psychometric properties of a Catalan translation of the Approaches and Study Skills Inventory for Students (ASSIST), and to analyse the different learning styles used by university students, considering the influence of gender and type of studies. The instrument was administered to 834 students at the University of Girona. The results showed that most students interviewed had a deep approach to learning, although the analysis by gender showed that females tended to use a more strategic approach, while males used a deep approach predominantly. As to whether the type of studies influenced learning styles, a prevalence of deep approach was found among Science and Technology students, while a more strategic approach was found among Humanities and Education students