840 resultados para operational reliability
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: The aim of this study was to compare pelvic floor muscle (PFM) strength using transvaginal digital palpation in healthy continent women in different age groups, and to compare the inter- and intra-rater reliability of examiners performing anterior and posterior vaginal assessments.Methods: We prospectively studied 150 healthy multiparous women. They were distributed into four different groups, according to age range: G1 (n = 37), 30-40 years-old; G2 (n = 39), 41-50 years-old; G3 (n = 39), 51-60 years-old; and G4 (n = 35), older than 60 years-old. PFM strength was evaluated using transvaginal digital palpation in the anterior and posterior areas, by 3 different examiners, and graded using a 5-point Amaro's scale.Results: There was no statistical difference among the different age ranges, for each grade of PFM strength. There was good intra-rater concordance between anterior and posterior PFM assessment, being 64.7%, 63.3%, and 66.7% for examiners A, B, and C, respectively. The intra-rater concordance level was good for each examiner. However, the inter-rater reliability for two examiners varied from moderate to good.Conclusions: Age has no effect on PFM strength profiles, in multiparous continent women. There is good concordance between anterior and posterior vaginal PFM strength assessments, but only moderate to good inter-rater reliability of the measurements between two examiners.
Resumo:
To date little is known about the reliability of peak oxygen consumption (VO2pEAK) in incremental metronome paced step tests (1ST) and the reliability of on-kinetics VO2 has never been studied. We aimed to study the reliability of both tests. Eleven healthy subjects performed two ISTs until exhaustion. On two different days two duplicate 4 min constant metronome paced step tests (CST) were performed. VO2PEAK, mean response time (MRT) and phase II time constant (tau) were tested for reproducibility using the paired t-tests, in addition to the limits of agreement (LOA) and within subject coefficient of variation (COV). With a 95% LOA of 0.38 to 0.26 L min(-1), -8.7 to 9.1 s and -9.9 to 10.5 s they exhibit a COV of 3%, 4.5% and 6.9% for VO2PEAK, MRT and tau respectively. ST are sufficiently reliable for maximal and submaximal aerobic power assessments in healthy subjects and new studies of oxygen uptake kinetics in selected patient groups are warranted. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
The present work aims at analyzing how the adoption of a proactive environmental management via green operational practices (GOPs) correlates to the Green Performance (GrP) of a given set of ISO 9001-certified firms in Brazil. To this end, we elaborated a conceptual framework about environmental management, GOPs, and GrP Such theoretical foundation supported the development of empirical research through quantitative analysis. For the analysis, 75 questionnaires were collected from ISO 9001 certified companies. Data was analyzed by with statistical tools such as descriptive analysis, correlation analysis, and Structural Equation Modeling (SEM). The results demonstrate that the adoption of GOPs, in fact, exerts a positive impact on the GrP of the firms. This work contributes to a better understanding of green manufacturing in Brazil's industrial sector
Resumo:
Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.
Resumo:
A study was carried out into the use of charcoal as a supplementary fuel in the iron-ore sintering process. The primary fuel was coke breeze and anthracite with 0, 10, 25, 50 and 100% replacement of the energy input with charcoal to produce sinter. This was achieved by considering the carbon content of each fuel and its corresponding participation on fuel blending, in order to have the same carbon input in each test run. An extensive analysis of the environmental impact was carried out regarding the atmospheric pollutants characterization (dust, sulphur dioxide, nitrogen oxides, carbon monoxide, carbon dioxide, methane, total hydrocarbons, and dioxins and furans). Experimental results indicate that fuel blending where 50% of the heat input was provided by charcoal may be comparable with those using 100% coke, under normal sintering conditions, and may result in a 50% reduction on greenhouse gas emission. It was also observed that while dust, methane and hydrocarbons emissions increased, the total dioxins and furans, expressed as polychlorinated dibenzodioxins/furans, decreased approximately 50% when compared with operation with 100% coke.
Resumo:
The use of Information and Communication Technology has grown in most agricultural activities. As a consequence, it has changed the way of thinking and acting of the farmer who wants to establish a more and more competitive market. However, the high costs of acquisition and maintenance of those technologies may be a factor which can inhibit its spread and acceptance, mainly to a large number of small grain Brazilian farmers. In this context, there is a need for innovative solutions that are proper for this universe of farmers. Starting from this premise, this paper presents the development of a low cost prototype to the monitoring process of temperature and humidity values of grains stored in silos, using communication based on wireless technology by radio frequency. Therefore, the economic implications of cost/benefit ratio of innovative application of wireless transmission in the process of thermometry of grains were analysed. The prototype was made of two electronic units, one of acquisition and another one of data reception, as well as computational software, which offered the farmer more precise information for the control of aeration. By means of stability, integrity and reliability tests of data transmission via radio, using low cost electronic components, the development system can be considered as potentially viable. It presented the difference regarding the wireless communication via radio in the process of grains thermometry, providing mobility, reducing cabling costs and maintenance, and also offering an easy system expansion; it was also appropriate to temperature and humidity monitoring in grain silos; and revealed operational viability, besides the low cost development when compared to similar products available in the Brazilian market.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The United States National Ice Center (NIC) provides weekly ice analyses of the Arctic and Antarctic using information from ice reconnaissance, ship reports and high-resolution satellite imagery. In cloud-covered areas and regions lacking imagery, the higher-resolution sources are augmented by ice concentrations derived from Defense Meteorological Satellite Program (DMSP) Special Sensor Microwave/Imager (SSMII) passive-microwave imagery. However, the SSMII-derived ice concentrations are limited by low resolution and uncertainties in thin-ice regions. Ongoing research at NIC is attempting to improve the utility of these SSMII products for operational sea-ice analyses. The refinements of operational algorithms may also aid future scientific studies. Here we discuss an evaluation of the standard operational ice-concentration algorithm, Cal/Val, with a possible alternative, a modified NASA Team algorithm. The modified algorithm compares favorably with CallVal and is a substantial improvement over the standard NASA Team algorithm in thin-ice regions that are of particular interest to operational activities.
Resumo:
The purpose of this study was to examine the reliability, validity and classification accuracy of the South Oaks Gambling Screen (SOGS) in a sample of the Brazilian population. Participants in this study were drawn from three sources: 71 men and women from the general population interviewed at a metropolitan train station; 116 men and women encountered at a bingo venue; and 54 men and women undergoing treatment for gambling. The SOGS and a DSM-IV-based instrument were applied by trained researchers. The internal consistency of the SOGS was 0.75 according to the Cronbach`s alpha model, and construct validity was good. A significant difference among groups was demonstrated by ANOVA (F ((2.238)) = 221.3, P < 0.001). The SOGS items and DSM-IV symptoms were highly correlated (r = 0.854, P < 0.01). The SOGS also presented satisfactory psychometric properties: sensitivity (100), specificity (74.7), positive predictive rate (60.7), negative predictive rate (100) and misclassification rate (0.18). However, a cut-off score of eight improved classification accuracy and reduced the rate of false positives: sensitivity (95.4), specificity (89.8), positive predictive rate (78.5), negative predictive rate (98) and misclassification rate (0.09). Thus, the SOGS was found to be reliable and valid in the Brazilian population.
Resumo:
This paper addresses the functional reliability and the complexity of reconfigurable antennas using graph models. The correlation between complexity and reliability for any given reconfigurable antenna is defined. Two methods are proposed to reduce failures and improve the reliability of reconfigurable antennas. The failures are caused by the reconfiguration technique or by the surrounding environment. These failure reduction methods proposed are tested and examples are given which verify these methods.
Resumo:
The use of patient-orientated questionnaires is of utmost importance in assessing the outcome of spine surgery. Standardisation, using a common set of outcome measures, is essential to aid comparisons across studies/in registries. The Core Outcome Measures Index (COMI) is a short, multidimensional outcome instrument validated for patients with spinal disorders. This study aimed to produce a Brazilian-Portuguese version of the COMI. A cross-cultural adaptation of the COMI into Brazilian-Portuguese was carried out using established guidelines. 104 outpatients with chronic LBP (> 3 months) were recruited from a Public Health Spine Medical Care Centre. They completed a questionnaire booklet containing the newly translated COMI, and other validated symptom-specific questionnaires: Oswestry Disability Index (ODI) and Roland Morris disability scale (RM), and a pain visual analogue scale. All patients completed a second questionnaire within 7-10 days to assess reproducibility. The COMI summary score displayed minimal floor and ceiling effects. On re-test, the responses for each individual domain of the COMI were within 1 category in 98% patients for the domain 'function', 96% for 'symptom-specific well-being', 97% for 'general quality of life', 99% for 'social disability' and 100% for 'work disability'. The intraclass correlation coefficients (ICC2,1) for COMI pain and COMI summary scores were 0.91-0.96, which compared favourably with the corresponding values for the RM (ICC, 0.99) and ODI (ICC, 0.98). The standard error of measurement for the COMI was 0.6, giving a "minimum detectable change" (MDC95%) of approximately 1.7 points i.e., the minimum change to be considered "real change" beyond measurement error. The COMI scores correlated as hypothesised (Rho, 0.4-0.8) with the other symptom-specific questionnaires. The reproducibility of the Brazilian-Portuguese version of the COMI was comparable to that of other language versions. The COMI scores correlated in the expected manner with existing but longer symptom-specific questionnaires suggesting good convergent validity for the COMI. The Brazilian-Portuguese COMI represents a valuable tool for Brazilian study-centres in future multicentre clinical studies and surgical registries.
Resumo:
Background and Purpose: Oropharyngeal dysphagia is a common manifestation in acute stroke. Aspiration resulting from difficulties in swallowing is a symptom that should be considered due to the frequent occurrence of aspiration pneumonia that could influence the patient's recovery as it causes clinical complications and could even lead to the patient's death. The early clinical evaluation of swallowing disorders can help define approaches and avoid oral feeding, which may be detrimental to the patient. This study aimed to create an algorithm to identify patients at risk of developing dysphagia following acute ischemic stroke in order to be able to decide on the safest way of feeding and minimize the complications of stroke using the National Institutes of Health Stroke Scale (NHISS). Methods: Clinical assessment of swallowing was performed in 50 patients admitted to the emergency unit of the University Hospital, Faculty of Medicine of Ribeirao Preto, Sao Paulo, Brazil, with a diagnosis of ischemic stroke, within 48 h after the beginning of symptoms. Patients, 25 females and 25 males with a mean age of 64.90 years (range 26-91 years), were evaluated consecutively. An anamnesis was taken before the patient's participation in the study in order to exclude a prior history of deglutition difficulties. For the functional assessment of swallowing, three food consistencies were used, i.e. pasty, liquid and solid. After clinical evaluation, we concluded whether there was dysphagia. For statistical analysis we used the Fisher exact test, verifying the association between the variables. To assess whether the NIHSS score characterizes a risk factor for dysphagia, a receiver operational characteristics curve was constructed to obtain characteristics for sensitivity and specificity. Results: Dysphagia was present in 32% of the patients. The clinical evaluation is a reliable method of detection of swallowing difficulties. However, the predictors of risk for the swallowing function must be balanced, and the level of consciousness and the presence of preexisting comorbidities should be considered. Gender, age and cerebral hemisphere involved were not significantly associated with the presence of dysphagia. NIHSS, Glasgow Coma Scale, and speech and language changes had a statistically significant predictive value for the presence of dysphagia. Conclusions: The NIHSS is highly sensitive (88%) and specific (85%) in detecting dysphagia; a score of 12 may be considered as the cutoff value. The creation of an algorithm to detect dysphagia in acute ischemic stroke appears to be useful in selecting the optimal feeding route while awaiting a specialized evaluation. Copyright (C) 2012 S. Karger AG, Basel
Resumo:
Synchronous telecommunication networks, distributed control systems and integrated circuits have its accuracy of operation dependent on the existence of a reliable time basis signal extracted from the line data stream and acquirable to each node. In this sense, the existence of a sub-network (inside the main network) dedicated to the distribution of the clock signals is crucially important. There are different solutions for the architecture of the time distribution sub-network and choosing one of them depends on cost, precision, reliability and operational security. In this work we expose: (i) the possible time distribution networks and their usual topologies and arrangements. (ii) How parameters of the network nodes can affect the reachability and stability of the synchronous state of a network. (iii) Optimizations methods for synchronous networks which can provide low cost architectures with operational precision, reliability and security. (C) 2011 Elsevier B. V. All rights reserved.
Resumo:
A power transformer needs continuous monitoring and fast protection as it is a very expensive piece of equipment and an essential element in an electrical power system. The most common protection technique used is the percentage differential logic, which provides discrimination between an internal fault and different operating conditions. Unfortunately, there are some operating conditions of power transformers that can mislead the conventional protection affecting the power system stability negatively. This study proposes the development of a new algorithm to improve the protection performance by using fuzzy logic, artificial neural networks and genetic algorithms. An electrical power system was modelled using Alternative Transients Program software to obtain the operational conditions and fault situations needed to test the algorithm developed, as well as a commercial differential relay. Results show improved reliability, as well as a fast response of the proposed technique when compared with conventional ones.