946 resultados para mesh opening rigidity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Climate models predict more frequent and more severe extreme events (e.g. heat waves, extended drought periods) in Europe during the next decades. The response of plants to elevated temperature is a key issue in this context. Stomatal regulation is not only relevant for the diffusion of CO2 from the ambient air into the leaves, but it plays also an important role for the control of transpiration and leaf cooling. The regulation of stomatal aperture by the water status (hydroactive and hydropassive feed-back) and by internal CO2 availability (CO2 feed-back) are well documented in the literature, while the response of the stomates to elevated temperature was far less considered in the past. Photosynthesis is negatively affected by elevated temperature, but the water loss via transpiration may still be high. In the experiments reported here, bean leaf segments were incubated in darkness floating on water in the range from 20 to 50°C and then analyzed immediately by taking a photograph with a digital microscope. Stomatal aperture was measured on these pictures in order to quantify stomatal opening. After the incubation for 30 min, the opening was 0.66, 2.76 and 4.28 μm at 23, 30 and 35°C respectively. This opening at elevated temperature was fully reversible. Abscisic acid (0.1 μM) in the incubation medium shifted the temperature for stomatal opening to higher values. It can be concluded that elevated temperature stimulates stomatal opening regardless of the CO2 assimilation status and that there is a trade-off between leaf cooling on one hand and limiting water loss during drought periods on the other hand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five cats with large, distal extremity abrasion wounds were treated with an autogenous, full-thickness, mesh skin graft. Survival of the mesh grafts in all five cats was considered between 90 and 100%. Successful grafting requires asepsis, an adequately prepared recipient bed consisting of healthy granulation tissue, proper harvesting and preparation of the graft, meticulous surgical technique and strict postoperative care. Factors that are essential for the survival of skin grafts include good contact between the graft and the recipient bed, normal tension on the sutured graft, strict immobilization after grafting and prevention of accumulation of blood or serum under the graft. Meshing the graft provides more graft flexibility over uneven surfaces and allows adequate drainage. In contrast to previous proposals, the authors recommend no bandage change before the fourth day after grafting. Full-thickness mesh skin grafting can be used to successfully treat large distal skin wounds in cats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Medial open wedge high tibial osteotomy is a well-established procedure for the treatment of unicompartmental osteoarthritis and symptomatic varus malalignment. We hypothesized that different fixation devices generate different fixation stability profiles for the various wedge sizes in a finite element (FE) analysis. METHODS Four types of fixation were compared: 1) first and 2) second generation Puddu plates, and 3) TomoFix plate with and 4) without bone graft. Cortical and cancellous bone was modelled and five different opening wedge sizes were studied for each model. Outcome measures included: 1) stresses in bone, 2) relative displacement of the proximal and distal tibial fragments, 3) stresses in the plates, 4) stresses on the upper and lower screw surfaces in the screw channels. RESULTS The highest load for all fixation types occurred in the plate axis. For the vast majority of the wedge sizes and fixation types the shear stress (von Mises stress) was dominating in the bone independent of fixation type. The relative displacements of the tibial fragments were low (in μm range). With an increasing wedge size this displacement tended to increase for both Puddu plates and the TomoFix plate with bone graft. For the TomoFix plate without bone graft a rather opposite trend was observed.For all fixation types the occurring stresses at the screw-bone contact areas pulled at the screws and exceeded the allowable threshold of 1.2 MPa for at least one screw surface. Of the six screw surfaces that were studied, the TomoFix plate with bone graft showed a stress excess of one out of twelve and without bone graft, five out of twelve. With the Puddu plates, an excess stress occurred in the majority of screw surfaces. CONCLUSIONS The different fixation devices generate different fixation stability profiles for different opening wedge sizes. Based on the computational simulations, none of the studied osteosynthesis fixation types warranted an intransigent full weight bearing per se. The highest fixation stability was observed for the TomoFix plates and the lowest for the first generation Puddu plate. These findings were revealed in theoretical models and need to be validated in controlled clinical settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statistical appearance models have recently been introduced in bone mechanics to investigate bone geometry and mechanical properties in population studies. The establishment of accurate anatomical correspondences is a critical aspect for the construction of reliable models. Depending on the representation of a bone as an image or a mesh, correspondences are detected using image registration or mesh morphing. The objective of this study was to compare image-based and mesh-based statistical appearance models of the femur for finite element (FE) simulations. To this aim, (i) we compared correspondence detection methods on bone surface and in bone volume; (ii) we created an image-based and a mesh-based statistical appearance models from 130 images, which we validated using compactness, representation and generalization, and we analyzed the FE results on 50 recreated bones vs. original bones; (iii) we created 1000 new instances, and we compared the quality of the FE meshes. Results showed that the image-based approach was more accurate in volume correspondence detection and quality of FE meshes, whereas the mesh-based approach was more accurate for surface correspondence detection and model compactness. Based on our results, we recommend the use of image-based statistical appearance models for FE simulations of the femur.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the minor products from the previously described peripheral -methylation of a magnesium()-20-methyl--pyrrocorphinate is a C-19-methylated 19,20-seco-corphinoid derivative which, on complexation with nickel() acetate, recyclizes to a nickel()-tetradehydro-corrinate.