920 resultados para measurement techniques of Aerosoles
Resumo:
The aim of this study was to make the first report on canine heartworm disease in the state of Rondônia and confirm its transmission in this state. Blood samples were randomly collected from 727 dogs in the city of Porto Velho. The samples were analyzed to search for microfilariae and circulating antigens, using three different techniques: optical microscopy on thick blood smears stained with Giemsa; immunochromatography; and PCR. Mosquitoes were collected inside and outside the homes of all the cases of positive dogs and were tested using PCR to search for DNA of Dirofilaria immitis. Ninety-three blood samples out of 727 (12.8%) were positive according to the immunoassay technique and none according to the thick smear method. Among the 93 positive dogs, 89 (95.7%) were born in Porto Velho. No difference in the frequency of infection was observed between dogs raised indoors and in the yard. PCR on the mosquitoes resulted in only one positive pool. This result shows that the transmission of canine heartworm disease is occurring in the city of Porto Velho and that there is moderate prevalence among the dogs. The techniques of immunochromatography and PCR were more effective for detecting canine heartworm than thick blood smears. The confirmation of canine heartworm disease transmission in Porto Velho places this disease in the ranking for differential diagnosis of pulmonary nodules in humans in Rondônia.
Resumo:
The aim of this study was to compare the techniques of indirect immunofluorescence assay (IFA) and flow cytometry to clinical and laboratorial evaluation of patients before and after clinical cure and to evaluate the applicability of flow cytometry in post-therapeutic monitoring of patients with American tegumentary leishmaniasis (ATL). Sera from 14 patients before treatment (BT), 13 patients 1 year after treatment (AT), 10 patients 2 and 5 years AT were evaluated. The results from flow cytometry were expressed as levels of IgG reactivity, based on the percentage of positive fluorescent parasites (PPFP). The 1:256 sample dilution allowed us to differentiate individuals BT and AT. Comparative analysis of IFA and flow cytometry by ROC (receiver operating characteristic curve) showed, respectively, AUC (area under curve) = 0.8 (95% CI = 0.64–0.89) and AUC = 0.90 (95% CI = 0.75–0.95), demonstrating that the flow cytometry had equivalent accuracy. Our data demonstrated that 20% was the best cut-off point identified by the ROC curve for the flow cytometry assay. This test showed a sensitivity of 86% and specificity of 77% while the IFA had a sensitivity of 78% and specificity of 85%. The after-treatment screening, through comparative analysis of the technique performance indexes, 1, 2 and 5 years AT, showed an equal performance of the flow cytometry compared with the IFA. However, flow cytometry shows to be a better diagnostic alternative when applied to the study of ATL in the cure criterion. The information obtained in this work opens perspectives to monitor cure after treatment of ATL.
Resumo:
This thesis presents and uses the techniques of computational chemistry to explore two different processes induced in human skin by ultraviolet light. The first is the transformation of urocanic acid into a immunosuppressing agent, and the other is the enzymatic action of the 8-oxoguanine glycosylase enzyme. The photochemistry of urocanic acid is investigated by time-dependent density functional theory. Vertical absorption spectra of the molecule in different forms and environments is assigned and candidate states for the photochemistry at different wavelengths are identified. Molecular dynamics simulations of urocanic acid in gas phase and aqueous solution reveals considerable flexibility under experimental conditions, particularly for for the cis isomer where competition between intra- and inter-molecular interactions increases flexibility. A model to explain the observed gas phase photochemistry of urocanic acid is developed and it is shown that a reinterpretation in terms of a mixture between isomers significantly enhances the agreement between theory and experiment , and resolves several peculiarities in the spectrum. A model for the photochemistry in the aqueous phase of urocanic acid is then developed, in which two excited states governs the efficiency of photoisomerization. The point of entrance into a conical intersection seam is shown to explain the wavelength dependence of photoisomerization quantum yield. Finally some mechanistic aspects of the DNA repair enzyme 8-oxoguanine glycosylase is investigated with density functional theory. It is found that the critical amino acid of the active site can provide catalytic power in several different manners, and that a recent proposal involving a SN1 type of mechanism seems the most efficient one.
Resumo:
[EN] In the frame of the restoration of natural populations of Cymodocea nodosa of the Canary Islands, seeds are being collected at natural populations where germination is rather scarce and seasonal after dormancy. We have developed techniques of propagation in vitro of collected seeds, consisting in forced seed germination and seedlings propagation to obtain mature 20-30 cm plantlet, which eventually are being used for restoration. In order to improve the developed methodology, several experiments were conducted to adjust conditions for seed storage under different regimes of temperature without loosing germinative potential, fertilize during propagation with controlled released NPK fertilizers, and increase growth by dipping seedlings in solutions of the most common plant hormones.
Resumo:
The study of electrochemiluminescence (ECL) involves photophysical and electrochemical aspects. Excited states are populated by an electrical stimulus. The most important applications are in the diagnostic field where a number of different biologically-relevant molecules (e.g. proteins and nucleic acids) can be recognized and quantified with a sensitivity and specificity previously not reachable. As a matter of fact the electrochemistry, differently to the classic techniques as fluorescence and chemiluminescence, allows to control the excited state generation spatially and temporally. The two research visits into A. J. Bard electrochemistry laboratories were priceless. Dr. Bard has been one of ECL pioneers, the first to introduce the technique and the one who discovered in 1972 the surprising emission of Ru(bpy)3 2+. I consider necessary to thank by now my supervisors Massimo and Francesco for their help and for giving me the great opportunity to know this unique science man that made me feel enthusiastic. I will never be grateful enough… Considering that the experimental techniques of ECL did not changed significantly in these last years the most convenient research direction has been the developing of materials with new or improved properties. In Chapter I the basics concepts and mechanisms of ECL are introduced so that the successive experiments can be easily understood. In the final paragraph the scopes of the thesis are briefly described. In Chapter II by starting from ECL experimental apparatus of Dr. Bard’s laboratories the design, assembly and preliminary tests of the new Bologna instrument are carefully described. The instrument assembly required to work hard but resulted in the introduction of the new technique in our labs by allowing the continuation of the ECL studies began in Texas. In Chapter III are described the results of electrochemical and ECL studies performed on new synthesized Ru(II) complexes containing tetrazolate based ligands. ECL emission has been investigated in solution and in solid thin films. The effect of the chemical protonation of the tetrazolate ring on ECL emission has been also investigated evidencing the possibility of a catalytic effect (generation of molecular hydrogen) of one of the complexes in organic media. Finally, after a series of preliminary studies on ECL emission in acqueous buffers, the direct interaction with calf thymus DNA of some complexes has been tested by ECL and photoluminescence (PL) titration. In Chapter IV different Ir(III) complexes have been characterized electrochemically and photophysically (ECL and PL). Some complexes were already well-known in literature for their high quantum efficiency whereas the remaining were new synthesized compounds containing tetrazolate based ligands analogous to those investigated in Chapt. III. During the tests on a halogenated complex was unexpectedly evidenced the possibility to follow the kinetics of an electro-induced chemical reaction by using ECL signal. In the last chapter (V) the possibility to use mono-use silicon chips electrodes as ECL analitycal devices is under investigation. The chapter begins by describing the chip structure and materials then a signal reproducibility study and geometry optimization is carried on by using two different complexes. In the following paragraphs is reported in detail the synthesis of an ECL label based on Ru(bpy)3 2+ and the chip functionalization by using a lipoic acid SAM and the same label. After some preliminary characterizations (mass spectroscopy TOF) has been demonstrated that by mean of a simple and fast ECL measurement it’s possible to confirm the presence of the coupling product SAM-label into the chip with a very high sensitivity. No signal was detected from the same system by using photoluminescence.
Resumo:
[EN]A solar radiation numerical model is presented. It is intented to be useful for different purposes like the evaluation of the suitability of possible locations for solar power stations. This model allows the user to evaluate the radiation values in any location easily, and estimate the solar power generation taking into account not only the radiation level, but also the terrain surface conditions considering the cast shadows. The solar radiation model is implemented taking into account the terrain surface using 2-D adaptive meshes of triangles, which are constructed using a refinement/derefinement procedure in accordance with the variations of terrain surface and albedo...
Resumo:
Die regionale Bestimmung der Durchblutung (Perfusion) ermöglicht differenzierte Aussagen über den Gesundheitszustand und die Funktionalität der Lunge. Durch neue Messverfahren ermöglicht die Magnetresonanztomographie (MRT) eine nicht-invasive und strahlungsfreie Untersuchung der Perfusion. Obwohl die Machbarkeit qualitativer MRT-Durchblutungsmessungen bereits gezeigt wurde, fehlt bisher eine validierte quantitative Methode. Ziel dieser Arbeit war eine Optimierung der bestehenden Messprotokolle und mathematischen Modelle zur Absolutquantifizierung der Lungenperfusion mit Magnetresonanztomographie. Weiterhin sollte die Methodik durch Vergleich mit einem etablierten Referenzverfahren validiert werden. Durch Simulationen und Phantommessungen konnten optimale MRT-Messparameter und ein standardisiertes Protokoll festgelegt werden. Des Weiteren wurde eine verallgemeinerte Bestimmung der Kontrastmittelkonzentration aus den gemessenen Signalintensitäten vorgestellt, diskutiert und durch Probandenmessungen validiert. Auf der Basis dieser Entwicklungen wurde die MRT-Durchblutungsmessung der Lunge tierexperimentell mit der Positronenemissionstomographie (PET) intraindividuell verglichen und validiert. Die Ergebnisse zeigten nur kleine Abweichungen und eine statistisch hochsignifikante, stark lineare Korrelation. Zusammenfassend war es durch die Entwicklungen der vorgestellten Arbeit möglich, die kontrastmittelgestützte MRT-Durchblutungsmessung der Lunge zu optimieren und erstmals zu validieren.
Resumo:
We have used kinematic models in two Italian regions to reproduce surface interseismic velocities obtained from InSAR and GPS measurements. We have considered a Block modeling, BM, approach to evaluate which fault system is actively accommodating the occurring deformation in both considered areas. We have performed a study for the Umbria-Marche Apennines, obtaining that the tectonic extension observed by GPS measurements is explained by the active contribution of at least two fault systems, one of which is the Alto Tiberina fault, ATF. We have estimated also the interseismic coupling distribution for the ATF using a 3D surface and the result shows an interesting correlation between the microseismicity and the uncoupled fault portions. The second area analyzed concerns the Gargano promontory for which we have used jointly the available InSAR and GPS velocities. Firstly we have attached the two datasets to the same terrestrial reference frame and then using a simple dislocation approach, we have estimated the best fault parameters reproducing the available data, providing a solution corresponding to the Mattinata fault. Subsequently we have considered within a BM analysis both GPS and InSAR datasets in order to evaluate if the Mattinata fault may accommodate the deformation occurring in the central Adriatic due to the relative motion between the North-Adriatic and South-Adriatic plates. We obtain that the deformation occurring in that region should be accommodated by more that one fault system, that is however difficult to detect since the poor coverage of geodetic measurement offshore of the Gargano promontory. Finally we have performed also the estimate of the interseismic coupling distribution for the Mattinata fault, obtaining a shallow coupling pattern. Both of coupling distributions found using the BM approach have been tested by means of resolution checkerboard tests and they demonstrate that the coupling patterns depend on the geodetic data positions.
Resumo:
The interaction between aerosols and sun light plays an important role in the radiative balance of Earth’s atmosphere. This interaction is obtained by measuring the removal (extinction), redistribution (scattering), and transformation into heat (absorption) of light by the aerosols; i.e. their optical properties. Knowledge of these properties is crucial for our understanding of the atmospheric system. rn Light absorption by aerosols is a major contributor to the direct and indirect effects on our climate system, and an accurate and sensitive measurement method is crucial to further our understanding. A homebuilt photoacoustic sensor (PAS), measuring at a 532nm wavelength, was fully characterized and its functionality validated for measurements of absorbing aerosols. The optical absorption cross-sections of absorbing polystyrene latex spheres, to be used as a standard for aerosol absorption measurements, were measured and compared to literature values. Additionally, a calibration method using absorbing aerosol of known complex refractive index was presented.rn A new approach to retrieve the effective broadband refractive indices (mbroad,eff) of aerosol particles by a white light aerosol spectrometer (WELAS) optical particle counter (OPC) was achieved. Using a tandem differential mobility analyzer (DMA)-OPC system, the nbroad,eff are obtained for both laboratory and field applications. This method was tested in the laboratory using substances with a wide range of optical properties and it was used in ambient measurements to retrieve the nbroad,eff of biomass burning aerosols in a nationwide burning event in Israel. The retrieved effective broadband refractive indices for laboratory generated scattering aerosols were: ammonium sulfate (AS), glutaric acid (GA), and sodium chloride, all within 4% of literature values. For absorbing substances, nigrosine and various mixtures of nigrosine with AS and GA were measured, as well as a lightly absorbing substance, Suwannee river fulvic acid (SRFA). For the ambient measurements, the calibration curves generated from this method were to follow the optical evolution of biomass burning (BB) aerosols. A decrease in the overall aerosol absorption and scattering for aged aerosols during the day after the fires compared to the smoldering phase of the fires was found. rn The connection between light extinction of aerosols, their chemical composition and hygroscopicity for particles with different degrees of absorption was studied. The extinction cross-section (σext) at 532nm for different mobility diameters was measured at 80% and 90% relative humidity (RH), and at an RH<10%. The ratio of the humidified aerosols to the dry ones, fRHext(%RH,Dry), is presented. For purely scattering aerosols, fRHext(%RH,Dry) is inversely proportional with size; this dependence was suppressed for lightly absorbing ones. In addition, the validity of the mixing rules for water soluble absorbing aerosols is explored. The difference between the derived and calculated real parts of the complex RIs were less than 5.3% for all substances, wavelengths, and RHs. The obtained imaginary parts for the retrieved and calculated RIs were in good agreement with each other, and well within the measurement errors of retrieval from pulsed CRD spectroscopy measurements. Finally, a core-shell structure model is also used to explore the differences between the models, for substances with low growth factors, under these hydration conditions. It was found that at 80% RH and for size parameters less than 2.5, there is less than a 5 % difference between the extinction efficiencies calculated with both models. This difference is within measurement errors; hence, there is no significant difference between the models in this case. However, for greater size parameters the difference can be up to 10%. For 90% RH the differences below a size parameter of 2.5 were up to 7%.rn Finally, the fully characterized PAS together with a cavity ring down spectrometer (CRD), were used to study the optical properties of soot and secondary organic aerosol (SOA) during the SOOT-11 project in the AIDA chamber in Karlsruhe, Germany. The fresh fractal-like soot particles were allowed to coagulate for 28 hours before stepwise coating them with SOA. The single scattering albedo for fresh fractal-like soot was measured to be 0.2 (±0.03), and after allowing the soot to coagulate for 28 hours and coating it with SOA, it increased to 0.71(±0.01). An absorption enhancement of the coated soot of up to 1.71 (±0.03) times from the non-coated coagulated soot was directly measured with the PAS. Monodisperse measurements of SOA and soot coated with SOA were performed to derive the complex refractive index (m) of both aerosols. A complex refractive index of m = 1.471(±0.008) + i0.0(±0.002) for the SOA-αO3 was retrieved. For the compact coagulated soot a preliminary complex refractive index of m = 2.04(+0.21/-0.14) + i0.34(+0.18/-0.06) with 10nm(+4/-6) coating thickness was retrieved.rn These detail properties can be use by modelers to decrease uncertainties in assessing climatic impacts of the different species and to improve weather forecasting.rn
Resumo:
Als ein vielversprechendes Konzept zur Erhöhung der thermoelektrischen Effizienz wird seit Anfang der 90er Jahre die Nutzung niederdimensionaler Systeme angesehen. Aus theoretischen Arbeiten von Hicks und Dresselhaus folgt, dass in ein- und zweidimensionalen Systemen eine Erhöhung der thermoelektrischen Effizienz möglich ist, die einen Durchbruch für die Anwendung thermoelektrischer Wandler zur Folge haben könnte. Die Realisierung solcher niederdimensionaler Systeme ist in geeigneten Mehrlagenstrukturen und durch Verwendung von Halbleiterverbindungen mit unterschiedlicher Energiebandlücke möglich. Ziel des Verbundprojektes Nitherma war es Mehrfachschichtsysteme mit 2-dimensionalem Transportverhalten aus thermoelektrischen Materialien (Pb1-xSrxTe, Bi2(SexTe1-x)3) herzustellen und auf die erwartete hohe thermoelektrische Effizienz zu untersuchen. Diese wurde messtechnischrndurch die Bestimmung der elektrischen Leitfähigkeit, des Seebeck-Koeffizienten und der Wärmeleitfähigkeit parallel zu den Schichtebenen (in-plane-Transporteigenschaft) ermittelt. Ziel dieser Arbeit war einerseits die Verbesserung der Präparations- und Messtechnik bei der Untersuchung der Wärmeleitfähigkeit von Schichten und Schichtsystemen sowie die Demonstration der Reproduzierbarkeit, andererseits die Interpretation der an niederdimensionalen Strukturen ermittelten Transportmessungen. Um den Einfluß der Niederdimensionalität auf die Wärmeleitfähigkeit zu ermitteln, wurden umfangreiche Messungen an unterschiedlich dimensionierten Übergitter- und Multi-Quantum-Well-Strukturen (MQW-Strukturen) durchgeführt. Die Verifizierung der von den Projektpartnern durchgeführten Transportmessungen wurde durch die Messung des Seebeck-Koeffizienten unterstützt.Neben der Charakterisierung durch Transportmessungen erfolgte die Bestimmung der thermoelektrischen Effizienz.
Resumo:
Das in dieser Arbeit vorgestellte Experiment zur Messung des magnetischen Moments des Protons basiert auf der Messung des Verhältnisses von Zyklotronfrequenz und Larmorfrequenz eines einzelnen, in einer kryogenen Doppel-Penning Falle gespeicherten Protons. In dieser Arbeit konnten erstmalig zwei der drei Bewegungsfrequenzen des Protons gleichzeitig im thermischen Gleichgewicht mit entsprechenden hochsensitiven Nachweissystemen nicht-destruktiv detektiert werden, wodurch die Messzeit zur Bestimmung der Zyklotronfrequenz halbiert werden konnte. Ferner wurden im Rahmen dieser Arbeit erstmalig einzelne Spin-Übergänge eines einzelnen Protons detektiert, wodurch die Bestimmung der Larmorfrequenz ermöglicht wird. Mithilfe des kontinuierlichen Stern-Gerlach Effekts wird durch eine sogenannte magnetische Flasche das magnetische Moment an die axiale Bewegungsmode des Protons gekoppelt. Eine Änderung des Spinzustands verursacht folglich einen Frequenzsprung der axialen Bewegungsfrequenz, welche nicht-destruktiv gemessen werden kann. Erschwert wird die Detektion des Spinzustands dadurch, dass die axiale Frequenz nicht nur vom Spinmoment, sondern auch vom Bahnmoment abhängt. Die große experimentelle Herausforderung besteht also in der Verhinderung von Energieschwankungen in den radialen Bewegungsmoden, um die Detektierbarkeit von Spin-Übergängen zu gewährleisten. Durch systematische Studien zur Stabilität der axialen Frequenz sowie einer kompletten Überarbeitung des experimentellen Aufbaus, konnte dieses Ziel erreicht werden. Erstmalig kann der Spinzustand eines einzelnen Protons mit hoher Zuverlässigkeit bestimmt werden. Somit stellt diese Arbeit einen entscheidenden Schritt auf dem Weg zu einer hochpräzisen Messung des magnetischen Moments des Protons dar.
Resumo:
This thesis regards the study and the development of new cognitive assessment and rehabilitation techniques of subjects with traumatic brain injury (TBI). In particular, this thesis i) provides an overview about the state of art of this new assessment and rehabilitation technologies, ii) suggests new methods for the assessment and rehabilitation and iii) contributes to the explanation of the neurophysiological mechanism that is involved in a rehabilitation treatment. Some chapters provide useful information to contextualize TBI and its outcome; they describe the methods used for its assessment/rehabilitation. The other chapters illustrate a series of experimental studies conducted in healthy subjects and TBI patients that suggest new approaches to assessment and rehabilitation. The new proposed approaches have in common the use of electroencefalografy (EEG). EEG was used in all the experimental studies with a different purpose, such as diagnostic tool, signal to command a BCI-system, outcome measure to evaluate the effects of a treatment, etc. The main achieved results are about: i) the study and the development of a system for the communication with patients with disorders of consciousness. It was possible to identify a paradigm of reliable activation during two imagery task using EEG signal or EEG and NIRS signal; ii) the study of the effects of a neuromodulation technique (tDCS) on EEG pattern. This topic is of great importance and interest. The emerged founding showed that the tDCS can manipulate the cortical network activity and through the research of optimal stimulation parameters, it is possible move the working point of a neural network and bring it in a condition of maximum learning. In this way could be possible improved the performance of a BCI system or to improve the efficacy of a rehabilitation treatment, like neurofeedback.
Resumo:
Diese Arbeit beschreibt die Entwicklung des flugzeuggetragenen Atmosphärischen Ionisations-Massenspektrometers AIMS-H2O zur Messung von Wasserdampf in der oberen Troposphäre und unteren Stratosphäre (UTLS) und erste Flugzeugmessungen mit dem Instrument. Wasserdampf beeinflusst das Klima in der UTLS aufgrund seiner Strahlungseigenschaften und agiert als wichtiger Parameter bei der Bildung von Zirruswolken und Kondensstreifen. Deshalb sind genaue Wasserdampfmessungen für das Verständnis vieler atmosphärischer Prozesse unerlässlich. Instrumentenvergleiche wie sie im SPARC Report No. 2 und dem Bericht der AUQAVIT Kampagne zusammengefasst sind, haben gezeigt, dass große Abweichungen zwischen einzelnen Methoden und Instrumenten bestehen. Diese Unsicherheiten limitieren das Verständnis des Einflusses von Wasserdampf auf die Dynamik und die Strahlungseigenschaften in der UTLS. Die in dieser Arbeit vorgestellte Entwicklung einer neuen Messmethode für Wasserdampf mit dem Massenspektrometer AIMS-H2O ist deshalb auf die genaue Messung niedriger Wasserdampfkonzentrationen in der UTLS fokussiert. Mit AIMS H2O wird Umgebungsluft in einer neu entwickelten Gasentladungsquelle ionisiert. Durch eine Reihe von Ionen-Molekül-Reaktionen entstehen H3O+(H2O) und H3O+(H2O)2 Ionen. Diese Ionen werden genutzt, um die Wasserdampfkonzentration in der Atmosphäre zu bestimmen. Um die erforderliche hohe Genauigkeit zu erzielen, wird AIMS H2O im Flug kalibriert. In dem zu diesem Zweck aufgebauten Kalibrationsmodul wird die katalytische Reaktion von Wasserstoff und Sauerstoff auf einer Platinoberfläche genutzt, um definierte Wasserdampfkonzentrationen für die Kalibration im Flug zu erzeugen. Bei ersten Messungen auf der Falcon während der Kampagne CONCERT 2011 konnte dabei eine Genauigkeit von 8 bis 15% für die Messung der Wasserdampfkonzentration in einem Messbereich von 0,5 bis 250 ppmv erreicht werden. Die Messfrequenz betrug 4 Hz, was einer räumlichen Auflösung von etwa 50 m entspricht. Der Vergleich der Messung des Massenspektrometers mit dem Laserhygrometer Waran zeigt eine sehr gute Übereinstimmung im Rahmen der Unsicherheiten. Anhand zweier Fallstudien werden die Messungen von AIMS H2O während CONCERT 2011 detailliert analysiert. In der ersten Studie werden zwei Flüge in eine stratosphärische Intrusion über Nordeuropa untersucht. In dieser Situation wurde stratosphärische Luft bis hinunter auf 6 km Höhe transportiert und war dadurch mit der Falcon erreichbar. Es konnte gezeigt werden, dass AIMS-H2O sehr gut für die genaue Messung niedriger Wasserdampfkonzentrationen, in diesem Fall bis etwa 3,5 ppmv, geeignet ist. Der Vergleich der Messung mit Analysen des ECMWF Integrated Forecast Systems zeigt eine gute Übereinstimmung der gemessenen Wasserdampfstrukturen mit der dynamischen Tropopause. Unterschiede tauchen dagegen beim Vergleich der Wasserdampfkonzentrationen in der unteren Stratosphäre auf. Hier prognostiziert das Modell deutlich höhere Feuchten. Die zweite Fallstudie beschäftigt sich mit der Verteilung der relativen Feuchte in jungen Kondensstreifen im Vergleich zu ihrer direkten Umgebung. Dabei wurde für drei Messsequenzen im Abgasstrahl von Flugzeugen beobachtet, dass die relative Feuchte innerhalb des Kondensstreifens im Vergleich zur Umgebung sowohl bei unter- als auch übersättigten Umgebungsbedingungen in Richtung Sättigung verschoben ist. Die hohe Anzahl an Eispartikeln und die damit verbundene große Eisoberfläche in jungen Kondensstreifen führt also zu einer schnellen Relaxation von Gasphase und Eis in Richtung Gleichgewicht. In der Zukunft soll AIMS-H2O auch auf HALO für die genaue Messung von Wasserdampf bei ML-CIRRUS und weiteren Kampagnen eingesetzt werden.
Resumo:
Toxicant inputs from agriculture, industry and human settlements have been shown to severely affect freshwater ecosystems. Pollution can lead to changes in population genetic patterns through various genetic and stochastic processes. In my thesis, I investigated the impact of anthropogenic stressors on the population genetics of the zebra mussel Dreissena polymorpha. In order to analyze the genetics of zebra mussel populations, I isolated five new highly polymorphic microsatellite loci. Out of those and other already existing microsatellite markers for this species, I established a robust marker set of six microsatellite loci for D. polymorpha. rnMonitoring the biogeographical background is an important requirement when integrating population genetic measures into ecotoxicological studies. I analyzed the biogeographical background of eleven populations in a section of the River Danube (in Hungary and Croatia) and some of its tributaries, and another population in the River Rhine as genetic outgroup. Moreover, I measured abiotic water parameters at the sampling sites and analyzed if they were correlated with the genetic parameters of the populations. The genetic differentiation was basically consistent with the overall biogeographical history of the populations in the study region. However, the genetic diversity of the populations was not influenced by the geographical distance between the populations, but by the environmental factors oxygen and temperature and also by other unidentified factors. I found strong evidence that genetic adaptation of zebra mussel populations to local habitat conditions had influenced the genetic constitution of the populations. Moreover, by establishing the biogeographical baseline of molecular variance in the study area, I laid the foundation for interpreting population genetic results in ecotoxicological experiments in this region.rnIn a cooperation project with the Department of Zoology of the University of Zagreb, I elaborated an integrated approach in biomonitoring with D. polymorpha by combining the analysis techniques of microsatellite analysis, Comet assay and micronucleus test (MNT). This approach was applied in a case study on freshwater contamination by an effluent of a wastewater treatment plant (WWTP) in the River Drava (Croatia) and a complementary laboratory experiment. I assessed and compared the genetic status of two zebra mussel populations from a contaminated and a reference site. Microsatellite analysis suggested that the contaminated population had undergone a genetic bottleneck, caused by random genetic drift and selection, whereas a bottleneck was not detected in the reference population. The Comet assay did not indicate any difference in DNA damage between the two populations, but MNT revealed that the contaminated population had an increased percentage of micronuclei in hemocytes in comparison to the reference population. The laboratory experiment with mussels exposed to municipal wastewater revealed that mussels from the contaminated site had a lower percentage of tail DNA and a higher percentage of micronuclei than the reference population. These differences between populations were probably caused by an overall decreased fitness of mussels from the contaminated site due to genetic drift and by an enhanced DNA repair mechanism due to adaptation to pollution in the source habitat. Overall, the combination of the three biomarkers provided sufficient information on the impact of both treated and non-treated municipal wastewater on the genetics of zebra mussels at different levels of biological organization.rnIn my thesis, I could show that the newly established marker set of six microsatellite loci provided reliable and informative data for population genetic analyses of D. polymorpha. The adaptation of the analyzed zebra mussel populations to the local conditions of their habitat had a strong influence on their genetic constitution. We found evidence that the different genetic constitutions of two populations had influenced the outcome of our ecotoxicological experiment. Overall, the integrated approach in biomonitoring gave comprehensive information about the impact of both treated and non-treated municipal wastewater on the genetics of zebra mussels at different levels of biological organization and was well practicable in a first case study.
Resumo:
Molecular dynamics simulations of silicate and borate glasses and melts: Structure, diffusion dynamics and vibrational properties. In this work computer simulations of the model glass formers SiO2 and B2O3 are presented, using the techniques of classical molecular dynamics (MD) simulations and quantum mechanical calculations, based on density functional theory (DFT). The latter limits the system size to about 100−200 atoms. SiO2 and B2O3 are the two most important network formers for industrial applications of oxide glasses. Glass samples are generated by means of a quench from the melt with classical MD simulations and a subsequent structural relaxation with DFT forces. In addition, full ab initio quenches are carried out with a significantly faster cooling rate. In principle, the structural properties are in good agreement with experimental results from neutron and X-ray scattering, in all cases. A special focus is on the study of vibrational properties, as they give access to low-temperature thermodynamic properties. The vibrational spectra are calculated by the so-called ”frozen phonon” method. In all cases, the DFT curves show an acceptable agreement with experimental results of inelastic neutron scattering. In case of the model glass former B2O3, a new classical interaction potential is parametrized, based on the liquid trajectory of an ab initio MD simulation at 2300 K. In this course, a structural fitting routine is used. The inclusion of 3-body angular interactions leads to a significantly improved agreement of the liquid properties of the classical MD and ab initio MD simulations. However, the generated glass structures, in all cases, show a significantly lower fraction of 3-membered planar boroxol rings as predicted by experimental results (f=60%-80%). The largest boroxol ring fraction of f=15±5% is observed in the full ab initio quenches from 2300 K. In case of SiO2, the glass structures after the quantum mechanical relaxation are the basis for calculations of the linear thermal expansion coefficient αL(T), employing the quasi-harmonic approximation. The striking observation is a change change of sign of αL(T) going along with a temperature range of negative αL(T) at low temperatures, which is in good agreement with experimental results.