846 resultados para loss offset


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We predict the loss of superfluidity in a Bose-Einstein condensate in an axially symmetric harmonic trap alone during resonant collective oscillations via a classical dynamical transition. The forced resonant oscillation can be initiated by (a) periodic modulation of the atomic scattering length with a frequency that equals twice the radial trapping frequency or multiples thereof, or by (b) periodic modulation of the radial trapping potential with a frequency that equals the radial trapping frequency or multiples thereof. Suggestion for future experiment is made. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We predict the loss of superfluidity in a Bose-Einstein condensate (BEC) trapped in a combined optical and axially-symmetric harmonic potentials during a resonant collective excitation initiated by a periodic modulation of the atomic scattering length a, when the modulation frequency equals twice the radial trapping frequency or multiples thereof. This classical dynamical transition is marked by a loss of superfluidity in the BEC and a subsequent destruction of the interference pattern upon free expansion. Suggestion for future experiment is made. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a methodology based on geostatistical theory for quantifying the risks associated with heavy-metal contamination in the harbor area of Santana, Amapa State, Northern Brazil. In this area there were activities related to the commercialization of manganese ore from Serra do Navio. Manganese and arsenic concentrations at unsampled sites were estimated by postprocessing results from stochastic annealing simulations; the simulations were used to test different criteria for optimization, including average, median, and quantiles. For classifying areas as contaminated or uncontaminated, estimated quantiles based on functions of asymmetric loss showed better results than did estimates based on symmetric loss, such as the average or the median. The use of specific loss functions in the decision-making process can reduce the costs of remediation and health maintenance. The highest global health costs were observed for manganese. (c) 2008 Elsevier B.V. All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A osteomalacia oncogênica é um diagnóstico clínico desafiador, caracterizado pela perda renal de fosfato e baixos níveis de 1,25-di-hidroxivitamina D3, ocorrendo na presença de um tumor produtor de altos níveis de fator de crescimento de fibroblasto 23. No entanto, é possível que se trate muito mais de uma falha de diagnóstico clínico do que propriamente uma doença rara. Os autores relatam o caso de um homem de 42 anos com histórico de fraqueza muscular progressiva por cinco anos e restrição à cadeira de rodas, sem diagnóstico. Seus exames laboratoriais evidenciavam baixos níveis de fósforo. A remoção cirúrgica de um hemangiopericitoma detectado previamente em cavidade nasal levou à resolução completa dos sintomas. Os autores enfatizam que, mesmo com a etiologia já evidenciada, o paciente consultou diversos clínicos no decorrer dos cinco anos até que fossem instituídos o diagnóstico e o tratamento adequados. Arq Bras Endocrinol Metab. 2012;56(8):570-3

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HfO2-(3-glycidoxipropil)trimethoxisilane (GPTS) planar waveguides were prepared by a sol-gel route. A stable sol of Hafnia nanocrystals was prepared and characterized by photon correlation spectroscopy and high resolution transmission electron microscopy. The suspension was incorporated in GPTS host and the resulting sol was deposited on borosilicate substrates by the spin coating technique. Optical properties such as refractive index, thickness, number of propagating modes, and attenuation coefficient were measured at 632.8, 543.5, and 1550 nm by the prism coupling technique as a function of the HfO2 content. (C) 2000 American Institute of Physics. [S0003-6951(00)03348-9].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaporative water loss (EWL) and oxygen uptake ((V) over dot o(2)) was measured in two species of tree frogs with cranial co-ossification, Aparasphenodon brunoi and Corythomantis greeningi. Both species use their head to seal the entrance of bromeliads, tree holes or rocky crevices used as shelters. EWL was significantly reduced in sheltered individuals of both species as compared with those exposed nude to desiccation. EWL per unit area through the head surface was significantly lower than the body skin for A. brunoi but not for C., greeningi. EWL per unit surface area through C. greeningi body skin was about 50% that of A. brunoi, indicating a less permeable skin in the former species. The relationship between cranial coossification and EWL is discussed. ((V) over dot o(2)) in A. brunoi was comparable with other anurans of similar size, whereas in C. greeningi, it was lower than predicted from body mass. Moreover, ((V) over dot o(2)), in C. greeningi showed less sensitivity to temperature increase than in A. brunoi. C. greeningi occurs in a drier environment than A. brunoi, and this appears to be reflected in their EWL and ((V) over dot o(2)) characteristics. (C) 1997 Elsevier B.V.