999 resultados para industrial chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas chromatography-mass spectrometry method is presented which allows the simultaneous determination of the plasma concentrations of the selective serotonin reuptake inhibitors citalopram, paroxetine, sertraline, and their pharmacologically active N-demethylated metabolites (desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline) after derivatization with the reagent N-methyl-bis(trifluoroacetamide). No interferences from endogenous compounds are observed following the extraction of plasma samples from six different human subjects. The standard curves are linear over a working range of 10-500 ng/mL for citalopram, 10-300 ng/mL for desmethylcitalopram, 5-60 ng/mL for didesmethylcitalopram, 20-400 ng/mL for sertraline and desmethylsertraline, and 10-200 ng/mL for paroxetine. Recoveries measured at three concentrations range from 81 to 118% for the tertiary amines (citalopram and the internal standard methylmaprotiline), 73 to 95% for the secondary amines (desmethylcitalopram, paroxetine and sertraline), and 39 to 66% for the primary amines (didesmethylcitalopram and desmethylsertraline). Intra- and interday coefficients of variation determined at three concentrations range from 3 to 11% for citalopram and its metabolites, 4 to 15% for paroxetine, and 5 to 13% for sertraline and desmethylsertraline. The limits of quantitation of the method are 2 ng/mL for citalopram and paroxetine, 1 ng/mL for sertraline, and 0.5 ng/mL for desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline. No interferences are noted from 20 other psychotropic drugs. This sensitive and specific method can be used for single-dose pharmacokinetics. It is also useful for therapeutic drug monitoring of these three drugs and could possibly be adapted for the quantitation of the two other selective serotonin reuptake inhibitors on the market, namely fluoxetine and fluvoxamine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report on America’s Agricultural Industrial Heritage Landscape, Inc., d/b/a Silos and Smokestacks National Heritage Area and Silos and Smokestacks Natural Heritage Area Foundation in Waterloo, Iowa for the years ended December 31, 2015 and 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi selecionar clones de batata para processamento industrial, cultivados em condições de clima subtropical e temperado do Sul do Brasil. Foram avaliados 30 clones avançados e três cultivares (testemunhas), na primavera de 2007 e 2008, e no outono de 2008, em Júlio de Castilhos, RS (condição de clima subtropical), e no verão de 2008 e 2009, em São Joaquim, SC (condição de clima temperado). Utilizou-se o delineamento experimental de blocos ao acaso, em arranjo fatorial (33 clones em 5 ambientes), com duas ou três repetições de dez covas. Foram avaliados: a produção por cova, a aparência, a cor de chips e os teores de matéria seca e de açúcares redutores dos tubérculos. Houve interação significativa entre clones e ambientes para todas as características avaliadas, exceto quanto à cor de chips. A produção por cova e o teor de matéria seca dos tubérculos foram maiores no cultivo de verão. As condições ambientais de cultivo afetaram todos os caracteres avaliados. As condições de cultivo do Sul do Brasil possibilitam a seleção de clones de batata, com suficiente teor de matéria seca, para atender às exigências da indústria de processamento de batata.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The screening of testosterone (T) misuse for doping control is based on the urinary steroid profile, including T, its precursors and metabolites. Modifications of individual levels and ratio between those metabolites are indicators of T misuse. In the context of screening analysis, the most discriminant criterion known to date is based on the T glucuronide (TG) to epitestosterone glucuronide (EG) ratio (TG/EG). Following the World Anti-Doping Agency (WADA) recommendations, there is suspicion of T misuse when the ratio reaches 4 or beyond. While this marker remains very sensitive and specific, it suffers from large inter-individual variability, with important influence of enzyme polymorphisms. Moreover, use of low dose or topical administration forms makes the screening of endogenous steroids difficult while the detection window no longer suits the doping habit. As reference limits are estimated on the basis of population studies, which encompass inter-individual and inter-ethnic variability, new strategies including individual threshold monitoring and alternative biomarkers were proposed to detect T misuse. The purpose of this study was to evaluate the potential of ultra-high pressure liquid chromatography (UHPLC) coupled with a new generation high resolution quadrupole time-of-flight mass spectrometer (QTOF-MS) to investigate the steroid metabolism after transdermal and oral T administration. An approach was developed to quantify 12 targeted urinary steroids as direct glucuro- and sulfo-conjugated metabolites, allowing the conservation of the phase II metabolism information, reflecting genetic and environmental influences. The UHPLC-QTOF-MS(E) platform was applied to clinical study samples from 19 healthy male volunteers, having different genotypes for the UGT2B17 enzyme responsible for the glucuroconjugation of T. Based on reference population ranges, none of the traditional markers of T misuse could detect doping after topical administration of T, while the detection window was short after oral TU ingestion. The detection ability of the 12 targeted steroids was thus evaluated by using individual thresholds following both transdermal and oral administration. Other relevant biomarkers and minor metabolites were studied for complementary information to the steroid profile, including sulfoconjugated analytes and hydroxy forms of glucuroconjugated metabolites. While sulfoconjugated steroids may provide helpful screening information for individuals with homozygotous UGT2B17 deletion, hydroxy-glucuroconjugated analytes could enhance the detection window of oral T undecanoate (TU) doping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative HS-GC/MS method applicable to the routine determination of butane concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature concerning butane measurement was the absence of a specific butane internal standard necessary to perform quantification. Because no stable isotope of butane is commercially available, it is essential to develop a new approach by an in situ generation of standards. To avoid the manipulation of a stable isotope-labelled gas, we have chosen to generate in situ an internal labelled standard gas (C(4)H(9)D) following the basis of the stoichiometric formation of butane by the reaction of deuterated water (D(2)O) with Grignard reagent butylmagnesium chloride (C(4)H(9)MgCl). This method allows a precise measurement of butane concentration and therefore, a full validation by accuracy profile was presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conditions for the analysis of selected doping substances by UHPSFC-MS/MS were optimized to ensure suitable peak shapes and maximized MS responses. A representative mixture of 31 acidic and basic doping agents was analyzed, in both ESI+ and ESI- modes. The best compromise for all compounds in terms of MS sensitivity and chromatographic performance was obtained when adding 2% water and 10mM ammonium formate in the CO2/MeOH mobile phase. Beside mobile phase, the nature of the make-up solvent added for interfacing UHPSFC with MS was also evaluated. Ethanol was found to be the best candidate as it was able to compensate for the negative effect of 2% water addition in ESI- mode and provided a suitable MS response for all doping agents. Sensitivity of the optimized UHPSFC-MS/MS method was finally assessed and compared to the results obtained in conventional UHPLC-MS/MS. Sensitivity was improved by 5-100-fold in UHPSFC-MS/MS vs. UHPLC-MS/MS for 56% of compounds, while only one compound (bumetanide) offered a significantly higher MS response (4-fold) under UHPLC-MS/MS conditions. In the second paper of this series, the optimal conditions for UHPSFC-MS/MS analysis will be employed to screen >100 doping agents in urine matrix and results will be compared to those obtained by conventional UHPLC-MS/MS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines the job prospects of displaced industrial workers in Switzerland. Based on a survey of 1,203 workers who were dismissed after their manufacturing plants closed down, we analyse the determinants of re-employment, the sector of re-employment and the change in wages. Two years after displacement, a majority of workers were back in employment: 69% were re-employed, 17% un-employed and 11% retired. Amongst re-employed workers, two thirds found a job in manufacturing and one third in services. Contrary to a common belief, low-end services are not the collecting vessel of redundant industrial workers. Displaced workers aged 55 and older seem particularly vulnerable after a plant closes down: over 30% were long-term unemployed, and those older workers who found a new job suffered disproportionate wage losses. Advanced age-and not low education-appears as the primary handicap after mass redundancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Granular flow phenomena are frequently encountered in the design of process and industrial plants in the traditional fields of the chemical, nuclear and oil industries as well as in other activities such as food and materials handling. Multi-phase flow is one important branch of the granular flow. Granular materials have unusual kinds of behavior compared to normal materials, either solids or fluids. Although some of the characteristics are still not well-known yet, one thing is confirmed: the particle-particle interaction plays a key role in the dynamics of granular materials, especially for dense granular materials. At the beginning of this thesis, detailed illustration of developing two models for describing the interaction based on the results of finite-element simulation, dimension analysis and numerical simulation is presented. The first model is used to describing the normal collision of viscoelastic particles. Based on some existent models, more parameters are added to this model, which make the model predict the experimental results more accurately. The second model is used for oblique collision, which include the effects from tangential velocity, angular velocity and surface friction based on Coulomb's law. The theoretical predictions of this model are in agreement with those by finite-element simulation. I n the latter chapters of this thesis, the models are used to predict industrial granular flow and the agreement between the simulations and experiments also shows the validation of the new model. The first case presents the simulation of granular flow passing over a circular obstacle. The simulations successfully predict the existence of a parabolic steady layer and show how the characteristics of the particles, such as coefficients of restitution and surface friction affect the separation results. The second case is a spinning container filled with granular material. Employing the previous models, the simulation could also reproduce experimentally observed phenomena, such as a depression in the center of a high frequency rotation. The third application is about gas-solid mixed flow in a vertically vibrated device. Gas phase motion is added to coherence with the particle motion. The governing equations of the gas phase are solved by using the Large eddy simulation (LES) and particle motion is predicted by using the Lagrangian method. The simulation predicted some pattern formation reported by experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Verkostoitunut kansainvälinen tuotekehitys on tärkeä osa menestystä nykypäivän muuttuvassa yritysmaailmassa. Toimintojen tehostamiseksi myös projektitoiminnot on sopeutettava kansainväliseen toimintaympäristöön. Kilpailukyvyn säilyttämiseksi projektitoimintoja on lisäksi jatkuvasti tehostettava. Yhtenäkeinona nähdään projektioppiminen, jota voidaan edistää monin eri tavoin. Tässätyössä keskitytään projektitiedonhallinnan kehittämisen tuomiin oppimismahdollisuuksiin. Kirjallisuudessa kerrotaan, että projektitiedon jakaminen ja sen hyödyntäminen seuraavissa projekteissa on eräs projektioppimisen edellytyksistä. Tämäon otettu keskeiseksi näkökulmaksi tässä tutkimuksessa. Lisäksi tutkimusalueen rajaamiseksi työ tarkastelee erityisesti projektioppimista kansainvälisten tuotekehitysprojektien välillä. Työn tavoitteena on esitellä keskeisiä projektioppimisen haasteita ja etsiä konkreettinen ratkaisu vastaamaan näihin haasteisiin. Tuotekehitystoiminnot ja kansainvälinen hajautettu projektiorganisaatio kohtaavat lisäksi erityisiä haasteita, kuten tiedon hajautuneisuus, projektihenkilöstön vaihtuvuus, tiedon luottamuksellisuus ja maantieteelliset haasteet (esim. aikavyöhykkeet ja toimipisteen sijainti). Nämä erityishaasteet on otettu huomioon ratkaisua etsittäessä. Haasteisiin päädyttiin vastaamaan tietotekniikkapohjaisella ratkaisulla, joka suunniteltiin erityisesti huomioiden esimerkkiorganisaation tarpeet ja haasteet. Työssä tarkastellaan suunnitellun ratkaisun vaikutusta projektioppimiseen ja kuinka se vastaa havaittuihin haasteisiin. Tuloksissa huomattiin, että projektioppimista tapahtui, vaikka oppimista oli vaikea suoranaisesti huomata tutkimusorganisaation jäsenten keskuudessa. Projektioppimista voidaan kuitenkin sanoa tapahtuvan, jos projektitieto on helposti koko projektiryhmän saatavilla ja se on hyvin järjesteltyä. Muun muassa nämä ehdot täyttyivät. Projektioppiminen nähdään yleisesti haastavana kehitysalueena esimerkkiorganisaatiossa. Suuri osa tietämyksestä on niin sanottua hiljaistatietoa, jota on hankala tai mahdoton saattaa kirjalliseen muotoon. Näin olleen tiedon siirtäminen jää suurelta osin henkilökohtaisen vuorovaikutuksen varaan. Siitä huolimatta projektioppimista on mahdollista kehittää erilaisin toimintamallein ja menetelmin. Kehitys vaatii kuitenkin resursseja, pitkäjänteisyyttä ja aikaa. Monet muutokset voivat vaatia myös organisaatiokulttuurin muutoksen ja vaikuttamista organisaation jäseniin. Motivaatio, positiiviset mielikuvat ja selkeät strategiset tavoitteet luovat vakaan pohjan projektioppimisen kehittämiselle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of buprenorphine and its major metabolite norbuprenorphine in human plasma. In order to speed up the process and decrease costs, sample preparation was performed by simple protein precipitation with acetonitrile. To the best of our knowledge, this is the first application of this extraction technique for the quantification of buprenorphine in plasma. Matrix effects were strongly reduced and selectivity increased by using an efficient chromatographic separation on a sub-2μm column (Acquity UPLC BEH C18 1.7μm, 2.1×50mm) in 5min with a gradient of ammonium formate 20mM pH 3.05 and acetonitrile as mobile phase at a flow rate of 0.4ml/min. Detection was made using a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The procedure was fully validated according to the latest Food and Drug Administration guidelines and the Société Française des Sciences et Techniques Pharmaceutiques. Very good results were obtained by using a stable isotope-labeled internal standard for each analyte, to compensate for the variability due to the extraction and ionization steps. The method was very sensitive with lower limits of quantification of 0.1ng/ml for buprenorphine and 0.25ng/ml for norbuprenorphine. The upper limit of quantification was 250ng/ml for both drugs. Trueness (98.4-113.7%), repeatability (1.9-7.7%), intermediate precision (2.6-7.9%) and internal standard-normalized matrix effects (94-101%) were in accordance with international recommendations. The procedure was successfully used to quantify plasma samples from patients included in a clinical pharmacogenetic study and can be transferred for routine therapeutic drug monitoring in clinical laboratories without further development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nicotine in a smoky indoor air environment can be determined using graphitized carbon black as a solid sorbent in quartz tubes. The temperature stability, high purity, and heat absorption characteristics of the sorbent, as well as the permeability of the quartz tubes to microwaves, enable the thermal desorption by means of microwaves after active sampling. Permeation and dynamic dilution procedures for the generation of nicotine in the vapor phase at low and high concentrations are used to evaluate the performances of the sampler. Tube preparation is described and the microwave desorption temperature is measured. Breakthrough volume is determined to allow sampling at 0.1-1 L/min for definite periods of time. The procedure is tested for the determination of gas and paticulate phase nicotine in sidestream smoke produced in an experimental chamber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes a fast gas chromatography/negative-ion chemical ionization tandem mass spectrometric assay (Fast GC/NICI-MS/MS) for analysis of tetrahydrocannabinol (THC), 11-hydroxy-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in whole blood. The cannabinoids were extracted from 500 microL of whole blood by a simple liquid-liquid extraction (LLE) and then derivatized by using trifluoroacetic anhydride (TFAA) and hexafluoro-2-propanol (HFIP) as fluorinated agents. Mass spectrometric detection of the analytes was performed in the selected reaction-monitoring mode on a triple quadrupole instrument after negative-ion chemical ionization. The assay was found to be linear in the concentration range of 0.5-20 ng/mL for THC and THC-OH, and of 2.5-100 ng/mL for THC-COOH. Repeatability and intermediate precision were found less than 12% for all concentrations tested. Under standard chromatographic conditions, the run cycle time would have been 15 min. By using fast conditions of separation, the assay analysis time has been reduced to 5 min, without compromising the chromatographic resolution. Finally, a simple approach for estimating the uncertainty measurement is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’objectiu d’aquest treball de recerca és el d’establir una “Ruta sobre el Patrimoni Industrial de la Garrotxa” amb la finalitat de potenciar el patrimoni industrial de la comarca; fomentar la seva protecció, rehabilitació i preservació; així com també fer accessible aquest patrimoni als visitants i habitants donant a conèixer diferents tipus d’accés a la ruta: a peu, amb bicicleta o amb cotxe