995 resultados para improving convergence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with a case study of the restoration of submerged macrophytes for improving water quality in a hypertrophic shallow lake, Lake Donghu of Wuhan, Hubei Province, China. Macrophyte restoration experiments were conducted in large-scale enclosures established in three sublakes of different trophic status, and the effectiveness for water quality improvement was tested by using the enclosure experiment in the hypertrophic sublake. Water quality was remarkably improved after the reestablishment of aquatic macrophytes. It is suggested that the submerged vegetation of less polluted sublakes could be capable of recovering spontaneously once the stocking of herbivorous fishes has been ceased, and the K-selected plants such as Potamogeton maackianus should be introduced into these sublakes to enhance the stability of aquatic vegetation. However, it may not be possible and economical to restore the submerged macrophytes in severely polluted basins unless external pollution has been cut off and internal nutrient loadings considerably reduced. In this case, the r-selected submerged plants should be used as the pioneer species for macrophyte recovery. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to effectively improve the classification performance of neural network, first architecture of fuzzy neural network with fuzzy input was proposed. Next a cost function of fuzzy outputs and non-fuzzy targets was defined. Then a learning algorithm from the cost function for adjusting weights was derived. And then the fuzzy neural network was inversed and fuzzified inversion algorithm was proposed. Finally, computer simulations on real-world pattern classification problems examine the effectives of the proposed approach. The experiment results show that the proposed approach has the merits of high learning efficiency, high classification accuracy and high generalization capability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electroabsorption modulator with large optical cavity was designed and fabricated successfully. Both the simulated and experimental results show that, the larger optical cavity structure introduced could obviously improve the optical profile of EA modulator, the traditional elliptical near-field spot becomes more rounded, so it will match better with the optical fiber and is beneficial for raising the coupling efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the simulation of two 2 x 2 electrooptical switches with different modulation area structures in silicon-on-insulator (SOI). A two-dimensional (2D) semiconductor device simulation tool PISCES-II has been used to analyze the dc and transient behaviors of the two devices. The modeling results show that the switch with an N+-I-P+-I-N+ modulation structure has a much faster response speed than the device with a P+-I-N+ modulation structure, although the former requires slightly stronger injection power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the binary exponential backoff mechanism of 802.11 distributed coordination function (DCF), and introduces some methods of modifying the backoff scheme. Then a novel backoff scheme, called Two-step Backoff scheme, is presented and illustrated. The simulation process in OPNET environment has been described also. At last, the analysis and simulation results show that the Two-step backoff scheme can enhance the performance of the IEEE 802.11 DCF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is common that documents are represented by document icon in graphical user interfaces. The document icon facilitates user to retrieve documents, but it is difficult to distinguish the document from a collection of documents that user have accessed to. Our paper presents a document icon on which the users can add some subjective values and mark. Then we describe a system ex-explorer that users can browser and search the extent document icon. We found that it is easy to re-find the document on which users added some annotation or mark by themselves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.