990 resultados para immediate implantation
Resumo:
Aims: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. Methods and results: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm2) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). Conclusions: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.
Resumo:
OBJECTIVES This study sought to determine the effect of rotational atherectomy (RA) on drug-eluting stent (DES) effectiveness. BACKGROUND DES are frequently used in complex lesions, including calcified stenoses, which may challenge DES delivery, expansion, and effectiveness. RA can adequately modify calcified plaques and facilitate stent delivery and expansion. Its impact on DES effectiveness is widely unknown. METHODS The ROTAXUS (Rotational Atherectomy Prior to TAXUS Stent Treatment for Complex Native Coronary Artery Disease) study randomly assigned 240 patients with complex calcified native coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120, standard therapy group). Stenting was performed using a polymer-based slow-release paclitaxel-eluting stent. The primary endpoint was in-stent late lumen loss at 9 months. Secondary endpoints included angiographic and strategy success, binary restenosis, definite stent thrombosis, and major adverse cardiac events at 9 months. RESULTS Despite similar baseline characteristics, significantly more patients in the standard therapy group were crossed over (12.5% vs. 4.2%, p = 0.02), resulting in higher strategy success in the rotablation group (92.5% vs. 83.3%, p = 0.03). At 9 months, in-stent late lumen loss was higher in the rotablation group (0.44 ± 0.58 vs. 0.31 ± 0.52, p = 0.04), despite an initially higher acute lumen gain (1.56 ± 0.43 vs. 1.44 ± 0.49 mm, p = 0.01). In-stent binary restenosis (11.4% vs. 10.6%, p = 0.71), target lesion revascularization (11.7% vs. 12.5%, p = 0.84), definite stent thrombosis (0.8% vs. 0%, p = 1.0), and major adverse cardiac events (24.2% vs. 28.3%, p = 0.46) were similar in both groups. CONCLUSIONS Routine lesion preparation using RA did not reduce late lumen loss of DES at 9 months. Balloon dilation with only provisional rotablation remains the default strategy for complex calcified lesions before DES implantation.
Resumo:
Background Atrioventricular (AV) conduction disturbances requiring permanent pacemaker (PPM) implantation may complicate transcatheter aortic valve replacement (TAVR). Available evidence on predictors of PPM is sparse and derived from small studies. Objectives The objective of this study was to provide summary effect estimates for clinically useful predictors of PPM implantation after TAVR. Methods We performed a systematic search for studies that reported the incidence of PPM implantation after TAVR and that provided raw data for the predictors of interest. Data on study, patient, and procedural characteristics were abstracted. Crude risk ratios (RRs) and 95% confidence intervals for each predictor were calculated by use of random effects models. Stratified analyses by type of implanted valve were performed. Results We obtained data from 41 studies that included 11,210 TAVR patients, of whom 17% required PPM implantation after intervention. The rate of PPM ranged from 2% to 51% in individual studies (with a median of 28% for the Medtronic CoreValve Revalving System [MCRS] and 6% for the Edwards SAPIEN valve [ESV]). The summary estimates indicated increased risk of PPM after TAVR for men (RR: 1.23; p < 0.01); for patients with first-degree AV block (RR: 1.52; p < 0.01), left anterior hemiblock (RR: 1.62; p < 0.01), or right bundle branch block (RR: 2.89; p < 0.01) at baseline; and for patients with intraprocedural AV block (RR: 3.49; p < 0.01). These variables remained significant predictors when only patients treated with the MCRS bioprosthesis were considered. The data for ESV were limited. Unadjusted estimates indicated a 2.5-fold higher risk for PPM implantation for patients who received the MCRS than for those who received the ESV. Conclusions Male sex, baseline conduction disturbances, and intraprocedural AV block emerged as predictors of PPM implantation after TAVR. This study provides useful tools to identify high-risk patients and to guide clinical decision making before and after intervention.
Resumo:
BACKGROUND: Little is known on the "very" long-term incidence of major adverse cardiac events (MACE), target-lesion revascularization (TLR), target-vessel revascularization and stent thrombosis after sirolimus-eluting stent (SES) implantation. We present the first study to provide a 10-year clinical follow-up in an unselected patient population who underwent SES implantation. METHODS AND RESULTS: We ran a systematic 10-year clinical follow-up in a series of 200 consecutive patients treated with unrestricted SES implantation between April 2002 and April 2003 in two Swiss hospitals. Outcomes and follow-up were obtained in all 200 patients. The cumulative 10-year MACE rate was 47% with all-cause death of 20%, cardiac death of 9%, myocardial infarction of 7%, TLR and target-vessel revascularization of 8% and 11% respectively. Academic Research Consortium-defined "definite and probable" stent thrombosis-rate was 2.5%. TLR risk was maximal between 3 to 6 years. New lesion revascularization increased throughout the study period. CONCLUSION: Incidence of TLR was maximal 3 to 6 years after SES implantation and decreased thereafter. MACE and non-TLR revascularization rates steadily increased during the complete follow-up underlining the progression of coronary artery disease.
Resumo:
INTRODUCTION Though developed for thoracic insufficiency syndrome, the spinal growth-stimulating potential and the ease of placement of vertical expandable titanium ribs (VEPTRs) has resulted in their widespread use for early-onset spine deformity. Observation of implant-related ossifications warrants further assessment, since they may be detrimental to the function-preserving non-fusion strategy. PATIENTS AND METHODS Radiographs (obtained pre and post index procedure, and at 4-year follow-up) and the records of 65 VEPTR patients from four paediatric spine centres were analysed. Ossifications were classified as type I (at anchor points), type II (along the central part) or type III (re-ossification after thoracostomy). RESULTS The average age at the index procedure was 6.5 years (min 1, max 13.7). The most prevalent spine problem was congenital scoliosis (37) with rib fusions (34), followed by neuromuscular and syndromic deformities (13 and 8, respectively). Idiopathic and secondary scoliosis (e.g. after thoracotomy) were less frequent (3 and 4, respectively). Forty-two of the 65 (65 %) patients showed ossifications, half of which were around the anchors. Forty-five percent (15/33) without pre-existing rib fusions developed a type II ossification along the implant. Re-ossifications of thoracostomies were less frequent (5/34, 15 %). The occurrence of ossifications was not associated with patient-specific factors. CONCLUSIONS Implant-related ossifications around VEPTR are common. In contrast to harmless bone formation around anchors, ossifications around the telescopic part and the rod section are troublesome in view of their possible negative impact on chest cage compliance and spinal mobility. This potential side effect needs to be considered during implant selection, particularly in patients with originally normal thoracic and spinal anatomy.
Resumo:
PURPOSE The objectives of this systematic review are (1) to quantitatively estimate the esthetic outcomes of implants placed in postextraction sites, and (2) to evaluate the influence of simultaneous bone augmentation procedures on these outcomes. MATERIALS AND METHODS Electronic and manual searches of the dental literature were performed to collect information on esthetic outcomes based on objective criteria with implants placed after extraction of maxillary anterior and premolar teeth. All levels of evidence were accepted (case series studies required a minimum of 5 cases). RESULTS From 1,686 titles, 114 full-text articles were evaluated and 50 records included for data extraction. The included studies reported on single-tooth implants adjacent to natural teeth, with no studies on multiple missing teeth identified (6 randomized controlled trials, 6 cohort studies, 5 cross-sectional studies, and 33 case series studies). Considerable heterogeneity in study design was found. A meta-analysis of controlled studies was not possible. The available evidence suggests that esthetic outcomes, determined by esthetic indices (predominantly the pink esthetic score) and positional changes of the peri-implant mucosa, may be achieved for single-tooth implants placed after tooth extraction. Immediate (type 1) implant placement, however, is associated with a greater variability in outcomes and a higher frequency of recession of > 1 mm of the midfacial mucosa (eight studies; range 9% to 41% and median 26% of sites, 1 to 3 years after placement) compared to early (type 2 and type 3) implant placement (2 studies; no sites with recession > 1 mm). In two retrospective studies of immediate (type 1) implant placement with bone graft, the facial bone wall was not detectable on cone beam CT in 36% and 57% of sites. These sites had more recession of the midfacial mucosa compared to sites with detectable facial bone. Two studies of early implant placement (types 2 and 3) combined with simultaneous bone augmentation with GBR (contour augmentation) demonstrated a high frequency (above 90%) of facial bone wall visible on CBCT. Recent studies of immediate (type 1) placement imposed specific selection criteria, including thick tissue biotype and an intact facial socket wall, to reduce esthetic risk. There were no specific selection criteria for early (type 2 and type 3) implant placement. CONCLUSIONS Acceptable esthetic outcomes may be achieved with implants placed after extraction of teeth in the maxillary anterior and premolar areas of the dentition. Recession of the midfacial mucosa is a risk with immediate (type 1) placement. Further research is needed to investigate the most suitable biomaterials to reconstruct the facial bone and the relationship between long-term mucosal stability and presence/absence of the facial bone, the thickness of the facial bone, and the position of the facial bone crest.
Resumo:
Owing to its single surgical intervention, immediate implant placement has the advantage of shortening treatment time, and thus positively affects patient morbidity. According to the bone resorption pattern after tooth extraction, bone loss should be anticipated if immediate implant placement is considered. The present case report aims to present a possible treatment option and to demonstrate that a partially edentulous arch may be rehabilitated esthetically by immediate implant placement and by corresponding anticipatory measures.
Resumo:
OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).
Resumo:
BACKGROUND There is great variability for the type of anaesthesia used during TAVI, with no clear consensus coming from comparative studies or guidelines. We sought to detect regional differences in the anaesthetic management of patients undergoing transcatheter aortic valve implantation (TAVI) in Europe and to evaluate the relationship between type of anaesthesia and in-hospital and 1year outcome. METHODS Between January 2011 and May 2012 the Sentinel European TAVI Pilot Registry enrolled 2807 patients treated via a transfemoral approach using either local (LA-group, 1095 patients, 39%) or general anaesthesia (GA-group, 1712 patients, 61%). RESULTS A wide variation in LA use was evident amongst the 10 participating countries. The use of LA has increased over time (from a mean of 37.5% of procedures in the first year, to 57% in last 6months, p<0.01). MI, major stroke as well as in-hospital death rate (7.0% LA vs 5.3% GA, p=0.053) had a similar incidence between groups, confirmed in multivariate regression analysis after adjusting for confounders. Dividing our population in tertiles according to the Log-EuroSCORE we found similar mortality under LA, whilst mortality was higher in the highest risk tertile under GA. Survival at 1year, compared by Kaplan-Meier analysis, was similar between groups (log-rank: p=0.1505). CONCLUSIONS Selection of anaesthesia appears to be more influenced by national practice and operator preference than patient characteristics. In the absence of an observed difference in outcomes for either approach, there is no compelling argument to suggest that operators and centres should change their anaesthetic practice.
Resumo:
Transapical transcatheter aortic valve implantation (TA-TAVI) is the recognized first choice surgical TAVI access. Expansion of this well-established treatment modality with subsequent broader patient inclusion has accelerated development of second-generation TA-TAVI devices. The Swiss ACURATE TA Symetis valve allows for excellent anatomical positioning, resulting in a very low incidence of paravalvular leaks. The self-expanding stent features an hourglass shape to wedge the native aortic valve annulus. A specially designed delivery system facilitates controlled release aided by tactile operator feedback. The ACURATE TA valve made of three native porcine non-coronary leaflets has received CE approval in September 2011. Since then, this valve is the third most frequently implanted TAVI device with over 1200 implants in Europe and South America. Results from the Symetis ACURATE TA™ Valve Implantation ('SAVI') Registry showed a procedural success rate of 98.0% and a survival rate of 93.2% at 30 days. This presentation provides technical considerations and detailed procedural aspects of device implantation.
Resumo:
Transcatheter aortic valve implantation (TAVI) has demonstrated the feasibility of treating valvular heart disease with transcatheter therapy. On the back of this success, various transcatheter concepts are being evaluated to treat other valvular disease, especially mitral regurgitation (MR). The concepts currently approved to treat MR replicate surgical mitral valve repair. However, most of them cannot eliminate MR completely. Similar to TAVI, a transcatheter mitral valve implantation may provide a valuable alternative. The FORTIS transcatheter mitral valve (Edwards Lifesciences, Irvine, CA, USA) is a self-expanding device implanted via a transapical approach. We describe our experience and early results in the first five patients treated on compassionate grounds. We also describe the details of the device, selection criteria and technical details of implantation.
Resumo:
This article provides an overview on procedure-related issues and uncertainties in outcomes after transcatheter aortic valve implantation (TAVI). The different access sites and how to select them in an individual patient are discussed. Also, the occurrence and potential predictors of aortic regurgitation (AR) after TAVI are addressed. The different methods to quantify AR are reviewed, and it appears that accurate and reproducible quantification is suboptimal. Complications such as prosthesis-patient mismatch and conduction abnormalities (and need for permanent pacemaker) are discussed, as well as cerebrovascular events, which emphasize the development of optimal anti-coagulative strategies. Finally, recent registries have shown the adoption of TAVI in the real world, but longer follow-up studies are needed to evaluate the outcome (but also prosthesis durability). Additionally, future studies are briefly discussed, which will address the use of TAVI in pure AR and lower-risk patients.
Resumo:
An exponential increase in the use of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis has been witnessed over the recent years. The current article reviews different areas of uncertainty related to patient selection. The use and limitations of risk scores are addressed, followed by an extensive discussion on the value of three-dimensional imaging for prosthesis sizing and the assessment of complex valve anatomy such as degenerated bicuspid valves. The uncertainty about valvular stenosis severity in patients with a mismatch between the transvalvular gradient and the aortic valve area, and how integrated use of echocardiography and computed tomographic imaging may help, is also addressed. Finally, patients referred for TAVI may have concomitant mitral regurgitation and/or coronary artery disease and the management of these patients is discussed.
Resumo:
IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.