960 resultados para Tyson, Ty
Resumo:
In2O3 is a promising partner of InN to form InN/In2O3 heterosystems. The valence band offset (VBO) of wurtzite InN/cubic In2O3 heterojunction is determined by x-ray photoemission spectroscopy. The valence band of In2O3 is found to be 1.47 +/- 0.11 eV below that of InN, and a type-I heterojunction with a conduction band offset (CBO) of 0.49-0.99 eV is found. The accurate determination of the VBO and CBO is important for use of InN/In2O3 based electronic devices.
Resumo:
Single crystalline ternary ZnxCd1-xS nanocombs, which have 'comb' shaped' teeth on one side, have been synthesized by a one-step metallo-organic chemical vapor deposition process at a low temperature of 420 degrees C. The asymmetric, growth behavior of the nanocombs is likely to be induced by the polarization of the c-ptane. Because of the uniform structure and perfect geometrical shape, the nanoteeth could be potentially useful as nanocantilever arrays for nanosensors and, nanotweezers. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Solutions for fiber-optical parametric amplifiers (FOPAs) with dispersion fluctuations are derived using matrix operators. On the basis of the propagation matrix product and the hybrid genetic algorithm, we have optimized and compared single- and dual-pump FOPAs with zero-dispersion-wavelength variations. The simulations prove that the design of FOPAs involves multimodal function optimization problems. The numerical results show that dual-pump FOPAs are highly sensitive to dispersion fluctuations whereas dispersion variations have less impact on the gain of single-pump FOPAs. To increase signal gain and reduce ripple, dual-pump FOPAs, instead of single-pump FOPAs, have to be carefully optimized with a suitable multisegment fiber structure rather than a one-segment fiber structure. The different combinations of multisegment fibers can provide highly different gain properties. The increase in gain is at the cost of the ripple.
Resumo:
The optical absorption of a GaAs/AlGaAs quantum dot superlattice nanoring (QDSLNR) under a lateral dc electric field and with magnetic flux threading the ring is investigated. This structure and configuration provides a unique opportunity to study the optical response of a superlattice under an inhomogeneous electric field, which is not easily realized for general quantum well superlattices (QWSLs) but naturally realized for QDSLNRs under a homogeneous lateral electric field. It has been shown that a lateral dc electric field gives rise to a substantial change of the optical absorption spectra. Under a low field, the excitonic optical absorption is dominated by a 1s exciton. And with the electric field increasing, the optical absorption undergoes a transition from 1s excitonic absorption to 0 excitronic WSL absorption. (The number of 0, and -1 and +1 below are WSLs index.) The -1 and the +1 WSLs corresponding to the maximum effective field can also be identified. Due to the inhomogeneity of the electric field, the peaks of the -1 and the +1 WSLs are diminished and between them there exist rich and complicated structures. This is in contrast to the general QWSLs under a homogenous electric field. The complicated structures can be understood by considering the inhomogeneity of the electric field along the ring, which results in the nearest-neighbor transition, the next-nearest-neighbor transition, etc., have a different value repectively, at different sites along the ring. This may give rise to multiple WSLs. We have also shown that the line shape of the optical absorption is not sensitive to the threading magnetic flux. The threading magnetic flux only gives rise to a slight diamagnetic shift. Thus the enhancement of the sensitivity to the flux allowing for observation of the excitonic Aharanov-Bohm effect in the plain nanoring is not expected in QDSLNRs.
Resumo:
An indentation simulation of the crystal Ni is carried out by a molecular dynamics technique (MD) to study the mechanical behavior at nanometer scales. Indenter tips with both sphere shape and conical shape with 60 cone angle are used, and simulation samples with different crystal orientations are adopted. Some defects such as dislocations and point defects are observed. It is found that nucleated defects (dislocations, amorphous atoms) are from the local region near the pin tip or the sample surface. The temperature distribution of the local region is analyzed and it can explain our MD simulation results.
Resumo:
A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.
Resumo:
根据苜蓿根瘤菌(Sinorhizobiummeliloti )Rm1021基因组中与RalstoniaeutrophaphaZ基因同源部分序列设计1对引物,从S.meliloti基因组中用PCR扩增出835bpphbD 基因片段并克隆到载体pGEM-TEasy上;通过在phbD基因内插入ΩSmSp和基因置换构建了phbD突变体。该突变体可积累比野生型菌株多1.0~2.6倍的聚羟丁酶(PHB)。在YMA和TY平板上形成非粘液型菌落,而在以乙酰乙酸或3-羟丁酸为唯一碳源的M9基本培养基(M9-AA,M9-HB)上形成粘液型菌落。碱性磷酸酶测定结果表明,通过接合引入phbD突变体菌株中的exoF-phoA融合基因在YMB培养基中低量表达,而在M9-AA和M9-HB中高量表达。
Constructing a raster-based spatio-temporal hierarchical data model for marine risheries application
Resumo:
Phenothiazine drugs, chlorpromazine hydrochloride (CPZ) and promethazine hydrochloride (PMZ), were determined with Ru(bpy)(3)(2+) electrochemiluminescene by the capillary electrophoresis (CE-ECL). It was found that both CPZ and PMZ could produce an intermediate that acted as coreactants to react with Ru(bpy)(3)(2+) to produce excited states which were capable of emitting light. This CE-ECL detection method had high sensitivity, good selectivity and reproducibility for CPZ and PMZ determination.
Resumo:
A novel ion-bonded discotic complex was prepared from 2,3,6,7,10,11-hexakis(N,N-dimethylaminopropylaminocarbonylmethoxy)triphenylene (HDTP) and 4'-dodecyloxybiphenyl-4-carboxylic acid (DBC) by ionic self-assembly (ISA) route and characterized by Fourier transform infrared (FTIR) spectrum. We found that the complex can self-assemble into stable gels in aromatic hydrocarbons. Nanofibers with diameters of 50-130 nm were observed in the gels by transmission electron micrograph (TEM).