975 resultados para Temperaturas do ar máxima e mínima
Resumo:
Directionally solidified zirconia-based eutectic (DSE) fibres were obtained using the laser floating zone (LFZ) method. Two systems were investigated: zirconia-barium zirconate and zirconia-mullite. The purpose was to take advantage of zirconia properties, particularly as an ionic conductor and a mechanical rein-forcement phase. The influence of processing conditions in the structural and microstructural characteristics and their consequences on the electrical and mechanical behaviour were the focus of this thesis. The novel zirconia-barium zirconate eutectic materials were developed in order to combine oxygen ionic conduction through zirconia with protonic conduction from barium zirconate, promoting mixed ionic conduction behaviour. The mi-crostructure of the fibres comprises two alternated regions: bands having coarser zirconia-rich microstructure; and inter-band regions changing from a homogeneous coupled eutectic, at the lowest pulling rate, to columnar colony microstructure, for the faster grown fibres. The bands inter-distance increases with the growth rate and, at 300 mm/h, zirconia dendrites develop enclosed in a fine-interpenetrated network of 50 vol.% ZrO2-50 vol.% BaZrO3. Both phases display contiguity without interphase boundaries, according to impedance spec-troscopy data. Yttria-rich compositions were considered in order to promote the yttrium incorporation in both phases, as revealed by Raman spectroscopy and corroborated by the elemental chemical analysis in energy dispersive spectros-copy. This is a mandatory condition to attain simultaneous contribution to the mixed ionic conduction. Such results are supported by impedance spectrosco-py measurements, which clearly disclose an increase of total ionic conduction for lower temperatures in wet/reduction atmospheres (activation energies of 35 kJ/mol in N2+H2 and 48 kJ/mol in air, in the range of 320-500 ºC) compared to the dry/oxidizing conditions (attaining values close to 90 kJ/mol, above 500 ºC). At high temperatures, the proton incorporation into the barium zirconate is un-favourable, so oxygen ion conduction through zirconia prevails, in dry and oxi-dizing environments, reaching a maximum of 1.3x10-2 S/cm in dry air, at ~1000 ºC. The ionic conduction of zirconia was alternatively combined with another high temperature oxygen ion conductor, as mullite, in order to obtain a broad elec-trolytic domain. The growth rate has a huge influence in the amount of phases and microstructure of the directionally solidified zirconia-mullite fibres. Their microstructure changes from planar coupled eutectic to dendritic eutectic mor-phology, when the growth rate rises from 1 to 500 mm/h, along with an incre-ment of tetragonal zirconia content. Furthermore, high growth rates lead to the development of Al-Si-Y glassy phase, and thus less mullite amount, which is found to considerably reduce the total ionic conduction of as-grown fibres. The reduction of the glassy phase content after annealing (10h; 1400 ºC) promotes an increase of the total ionic conduction (≥0.01 S/cm at 1370 °C), raising the mullite and tetragonal zirconia contents and leading to microstructural differ-ences, namely the distribution and size of the zirconia constituent. This has important consequences in conductivity by improving the percolation pathways. A notable increase in hardness is observed from 11.3 GPa for the 10 mm/h pulled fibre to 21.2 GPa for the fibre grown at 500 mm/h. The ultra-fine eutectic morphology of the 500 mm/h fibres results in a maximum value of 534 MPa for room temperature bending strength, which decreases to about one-fourth of this value at high temperature testing (1400 ºC) due to the soft nature of the glassy-matrix.
Resumo:
Dissertação mest., Engenharia Biológica, Universidade do Algarve, 2009
Resumo:
Dissertação de Mestrado, Biologia Marinha, Faculdade de Ciências do Mar e do Ambiente, Universidade do Algarve, 2007
Resumo:
Dissertação mest., Gestão Sustentável de Espaços Rurais, Universidade do Algarve, 2009
Resumo:
Tese de dout., Bioquímica (Biologia Celular e Molecular), Faculdade de Ciências e Tecnologia, Univ. do Algarve, 2010
Resumo:
Dissertação de mest, Tecnologia de Alimentos, Instituto Superior de Engenharia, Univ. do Algarve, 2013
Resumo:
A presença de cianobactérias em reservatórios utilizados para produção de água para consumo humano representa um elevado risco para a saúde pública. Estes organismos contribuem para a redução da qualidade da água e têm a capacidade de produzir cianotoxinas que podem afectar a saúde humana e animal. Existem casos em todo o mundo de intoxicação letal de diversos animais por consumo de água de lagos contaminados com cianobactérias, e mesmo casos de morte de humanos, atribuídas à exposição de cianotoxinas. De modo a fazer face a este crescente problema é necessário desenvolver e implementar tecnologias de tratamento de água nas ETA que permitam fazer face a uma florescência de cianobactérias num reservatório de água destinado ao abastecimento humano. Neste trabalho avaliou-se a capacidade do processo C/F/DAF na remoção cianobactérias de diferentes morfologias, células e colónias de M. aeruginosa e filamentos de P. rubescens, em águas sintéticas hidrofóbicas e hidrofílicas, com concentração de DOC moderada e moderada/elevada. Assim como da sequência C/F/DAF→NF na remoção de células e de toxinas de cianobactérias. A remoção de NOM e o seu efeito na remoção de cianobactérias foram também avaliados. Concluiu-se que o processo C/F/DAF é eficiente na remoção de cianobactérias de diferentes morfologias, com remoções entre 78 e 100% de MC intra. No entanto, a morfologia que apresentou remoções mais elevadas foram os filamentos, enquanto as colónias apresentaram valores mais baixos. Globalmente, verificou-se que o aumento da concentração de NOM facilita a remoção de cianobactérias, sendo que as águas hidrofóbicas apresentaram-se mais fáceis de tratar por C/F/DAF. Por sua vez, o tratamento C/F/DAF→NF, é uma opção eficiente para fazer face a um eventual bloom de cianobactérias em ETA, uma vez que a remoção de cianobactérias (em MC intra e chl_a) foi de 100% e a remoção de microcistina extracelular de 95%, aproximadamente.
Resumo:
Thermal degradation and gaseous products evolving from the pyrolysis of sewage sludge, aimed at agricultural soil amendment, were investigated using Thermogravimetric Analysis in conjunction with Fourier Transform Infrared Analysis (TG-FTIR). The materials were studied in temperatures ranging from 30 to 800 ºC. Furthermore infrared spectra of sewage sludge samples were performed as a complementary technique. In parallel the sewage sludge was spiked with ibuprofen in order to test whether the mentioned techniques are able to detect the drug. Thermal analysis showed the range of 200-400ºC as the most characteristic for weight loss, corresponding with the organic matter volatilization, while the range of 500-800ºC was also characteristic and due to the volatilization of carbonates. On the other hand, ibuprofen-spiking tests identified at temperature range (150-250ºC) where the compound totally volatilizes, therefore, in this work, the detection of ibuprofen by TGA was established for concentrations higher than 0.5 g/kg sludge, concentration 102 times higher than the concentrations measured by other authors in regular sewage sludge (Martín, et al., 2010). A correlation has been found between the ibuprofen concentrations in the sludge and the intensity of the absorption bands, both for FT-IR spectra at the maximum emission temperature for ibuprofen (232ºC) as for the FT-IR spectra of the non-pyrolyzed samples.
Resumo:
Neste trabalho é desenvolvido um estudo comparativo de vários sistemas de ventilação, baseados em jactos localizados. Foram avaliados, para cada um deles, o nível da qualidade do ar interior, conforto térmico, desconforto térmico local (risco de resfriamento) a que os ocupantes estão sujeitos e o índice ADI (Air Distribution Index). O estudo foi efectuado numericamente, a partir de dois softwares acoplados, e experimentalmente, a partir de uma sala de aula desenvolvida a escala real. Nesta sala de aulas, equipada com 6 ou 12 ocupantes e com 6 secretárias, foram analisados sistemas de ventilação com jactos verticais descendentes, localizados em cima (mais afastado e mais próximo do nível da cabeça dos ocupantes) e à frente dos ocupantes, e com jactos horizontais, localizados em frente dos ocupantes, em cima e em baixo da secretária. O estudo numérico, da interacção do escoamento com os ocupantes, foi efectuado a partir do acoplamento de um software que simula a resposta térmica dos ocupantes (Human Thermal Comfort) e um que simula o escoamento tridimensional em espaços ocupados (Virtual Air Flow - 3D), utilizando o modelo de turbulência RNG. Foi utilizada uma malha não uniforme, com um maior refinamento junto dos obstáculos e nas entradas e saídas de ar. No estudo do projecto do sistema de ventilação baseado em jactos verticais descendentes localizados em cima e mais afastado do nível da cabeça dos ocupantes, foram efectuadas medições experimentais de forma a validar os softwares acoplados e um modelo desenvolvido para calcular o escoamento unidireccional no interior de condutas. Neste estudo foi ainda utilizado um modelo de cálculo das temperaturas das superfícies. Por fim foi realizada uma simulação num contexto mais real, com 6 ocupantes sentados e um ocupante em pé, simulando 6 alunos e um professor, onde foi utilizado o acoplamento dos modelos Human Thermal Comfort e Virtual Air Flow - 3D, o modelo numérico de escoamentos unidireccionais no interior de condutas e o modelo de cálculo das temperaturas das superfícies. São ainda feitas sugestões para a partir deste trabalho, se efectuarem estudos em geometrias mais complexas.
Resumo:
Dissertação de mestrado, Hortofruticultura, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2014
Resumo:
Dissertação de Mestrado, Ciências da Educação, Escola Superior de Educação, Universidade do Algarve, 1998
Resumo:
Tese de doutoramento, Ciências Geofísicas e da Geoinformação (Oceanografia), Universidade de Lisboa, Faculdade de Ciências, 2014
Resumo:
Senior thesis written for Oceanography 445
Resumo:
Este estudo pretende analisar a influência do caudal de ar novo insuflado num edifício administrativo no desempenho energético do seu sistema AVAC. O RSECE determina os caudais mínimos de AN para renovação do ar interior e qualidade do ar aceitável em espaços em que não haja fontes atípicas de poluentes e sem fumadores. Existe uma tendência para se projectar sistemas AVAC insuflando o caudal mínimo de AN, para assim se poupar no consumo de energia. No entanto, em determinadas situações, com esse procedimento está-se a fazer precisamente o contrário. Nessas situações não se está a aproveitar a oportunidade de aumentar a QAI e, simultaneamente, reduzir o consumo de energia. Neste estudo calculou-se o consumo energético do sistema AVAC do edifício, inicialmente insuflando o caudal mínimo de AN, e depois repetiu-se o cálculo várias vezes aumentando esse mesmo caudal progressivamente. Este cálculo foi feito para dois tipos de sistemas de ar, CAV e VAV, e para três localizações diferentes do mesmo edifício. Foi também estudada a possibilidade do sistema funcionar em regime de “free cooling”, e também foram feitos cálculos para diferentes temperaturas de insuflação em situação de arrefecimento. Concluiu-se que, para as localizações do edifício em que este apresenta necessidades de arrefecimento anuais superiores às de aquecimento, o caudal de AN responsável pelo menor consumo energético do seu sistema AVAC é superior ao mínimo imposto pelo RSECE. Observou-se também que, quando se insufla no edifício o caudal mínimo de AN e o sistema está preparado para funcionar em regime de “free cooling”, conseguem-se poupanças no consumo energético anual do sistema bastante relevantes, independentemente do balanço entre as necessidades de aquecimento e arrefecimento anuais que o edifício apresenta. Em relação aos dois sistemas de ar estudados concluiu-se que, em qualquer das situações estudadas, o sistema VAV apresenta consumos energéticos inferiores.
Resumo:
O controlo ambiental deverá garantir a adequada qualidade microbiológica do ar e superfícies nas unidades de saúde possibilitando a redução das infecções associadas, tanto nos utentes como nos colaboradores. A presente comunicação refere as principais fontes de contaminação ambiental a considerar, a metodologia de avaliação de risco e o estabelecimento de valores guia para os controlos do ar e superfícies.