951 resultados para Pharmaceutical Preparations, Dental
Resumo:
Drying is a major step in the manufacturing process in pharmaceutical industries, and the selection of dryer and operating conditions are sometimes a bottleneck. In spite of difficulties, the bottlenecks are taken care of with utmost care due to good manufacturing practices (GMP) and industries' image in the global market. The purpose of this work is to research the use of existing knowledge for the selection of dryer and its operating conditions for drying of pharmaceutical materials with the help of methods like case-based reasoning and decision trees to reduce time and expenditure for research. The work consisted of two major parts as follows: Literature survey on the theories of spray dying, case-based reasoning and decision trees; working part includes data acquisition and testing of the models based on existing and upgraded data. Testing resulted in a combination of two models, case-based reasoning and decision trees, leading to more specific results when compared to conventional methods.
Resumo:
Esta entrega, que forma parte de una serie de Nursing sobre las pruebas complementarias, está dedicada a las técnicas de imagen para la exploración dental. La exploración y el diagnóstico se pueden llevar a cabo mediante diferentes modalidades diagnósticas. Las más habituales son la radiología convencional, la tomografía computarizada (TC) y la resonancia magnética (RM). Para facilitar a los profesionales de enfermería los recursos necesarios para satisfacer las demandas de información de los pacientes, es necesario un recorrido por estas técnicas, habituales en los diferentes ámbitos asistenciales. Desde el punto de vista de atención al paciente es útil poder explicar y despejar las dudas que se pudieran plantear respecto a la preparación, a la dinámica y, en general, al proceso diagnóstico.
Resumo:
Esta entrega, que forma parte de una serie de Nursing sobre las pruebas complementarias, está dedicada a las técnicas de imagen para la exploración dental. La exploración y el diagnóstico se pueden llevar a cabo mediante diferentes modalidades diagnósticas. Las más habituales son la radiología convencional, la tomografía computarizada (TC) y la resonancia magnética (RM). Para facilitar a los profesionales de enfermería los recursos necesarios para satisfacer las demandas de información de los pacientes, es necesario un recorrido por estas técnicas, habituales en los diferentes ámbitos asistenciales. Desde el punto de vista de atención al paciente es útil poder explicar y despejar las dudas que se pudieran plantear respecto a la preparación, a la dinámica y, en general, al proceso diagnóstico.
Resumo:
El patrón de microestriación dentaria depende no solo de la composición de los alimentos ingeridos, sino también de la presencia en ellos de polvo, cenizas u otras partículas abrasivas de origen externo, generalmente incorporadas al alimento durante su preparación. El presente estudio analiza cómo se ve afectado el patrón de microestriación de la superficie vestibular de los dientes por factores independientes a la estructura y composición alimentaria, como son el tamaño de la pieza dentaria y el desgaste oclusal de la misma. Se han analizado moldes dentarios obtenidos de ejemplares originales de colecciones osteológicas de molares de primates Hominoideos, en los que se ha medido el patrón de microestriación dentaria de todos los individuos, así como el tamaño dental (área oclusal total- AOT) y el desgaste oclusal (porcentaje de exposición de dentina- PED) mediante técnicas semiautomáticas de análisis cuantitativo. Los resultados obtenidos indican que el tamaño dentario y el grado de desgaste oclusal de los molares analizados no están correlacionados con el patrón de microdesgaste dental de sus superficies vestibulares. Ello sugiere que las actividades masticatorias asociadas con las superficies oclusales de los molares no están directamente relacionadas con la capacidad abrasiva del alimento, sino con utilización de la superficie occlusal de la dentición en actividades que no repercuten en el patrón de microestriación de las superficies vestibulares de los dientes.
Resumo:
Antimony preparations are the drugs of choice for the treatment of leishmaniasis over 90 years, a disease that currently affects 12 million people worldwide. Its introduction was based on 19th century concepts of therapeutic effects of metal salts as arsenicals and other metals, most of them abandoned due to toxic effects or better drugs. In the last three decades, there was a great improvement in the knowledge of cell biology and immunology of those infections, but chemotherapy has not been improved in the same strength. The structure and mechanism of action of the two pentavalent antimonial drugs of choice, meglumine antimoniate and sodium stibogluconate, are not well known and the contamination of those pharmaceutical by toxic contaminants have been verified.
Resumo:
A multicompartment compliance aid (MCA) is a blister-type repackaging system that aims to facilitate drug administration and thereby increase patient adherence. One of the characteristics of the MCA that should be taken into account is the moisture permeability, since this atmospheric condition is one of the most important factors that can modify the stability of medicines. In the current paper we report the moisture permeability tests performed on a MCA according to the US Pharmacopeia. This information on the suitability of the device will help pharmacists implement a high-quality professional service.
Resumo:
Eighteen circular blocks of resins cured either by a LED or a halogen lamp (20, 40 and 60 s), had their top (T) and bottom (B) surfaces studied using a FT-Raman spectrometer. Systematic changes in the intensity of the methacrylate C=C stretching mode at 1638 cm-1 as a function of exposure duration were observed. The calculated degree of conversion (DC) ranged from 45.0% (B) to 52.0% (T) and from 49.0% (B) to 55.0% (T) for the LED and halogen lamp, respectively. LED and halogen light produced similar DC values with 40 and 60 s of irradiation.
Resumo:
Fast development in the operating environment and fierce competition have driven companies to pursue efficiency and success through lean and global supply chains. At the same time overall uncertainty has increased in the business environment and supply chains have become a priority in risk management since their vulnerability may endanger business continuity. Although risk management should start at procurement strategy development phase, proactive contingency planning is also essential because it enables correct reaction and fast changes in process execution in the case of risk realization. This thesis is a case study conducted in the pharmaceutical industry where purchasing and materials management organizations face a number of challenges and limitations that have to be considered in supply risk management. The goal of the study was to discuss the operating environment, and identify and analyze supply risks and potential risk management practices. The study was concluded with suggestions for purchasing strategy development that take risk management considerations into account. This copy is the public version of the thesis.
Resumo:
A simple, fast and sensitive spectrophotometric method for the determination of cefaclor in pharmaceutical raw and dosage forms based on reaction with ninhydrin is developed, optimized and validated. The purple color (Ruhemenn's purple) that resulted from the reaction was stabilized and measured at 560 nm. Beer's law is obeyed in the concentration range of 4-80 µg mL-1 with molar absorptivity of 1.42 × 10(5) L mole-1 cm-1. All variables including the reagent concentration, heating time, reaction temperature, color stability period, and cefaclor/ninhydrin ratio were studied in order to optimize the reaction conditions. No interference was observed from common pharmaceutical adjuvant. The developed method is easy to use, accurate and highly cost-effective for routine studies relative to HPLC and other techniques.
Resumo:
A flow-injection (FI) spectrophotometric procedure is proposed for tetracycline (TC) and doxycycline (DXC) determination in pharmaceuticals. The method is based on the reaction of oxidation of these drugs by chloramine-T in alkaline medium producing red color products (λmax = 535 and 525 nm). Beer´s law is obeyed in the concentration range from 6.62 x 10-5 to 7.72 x 10-4 mol L-1 and 5.37 x 10-5 to 7.16 x 10-4 mol L-1 for TC and DXC, respectively. The analytical frequency was 50 h"1 and 45 h-1 for TC and DXC, respectively. The results obtained by the proposed method were in good agreement with those obtained by the official method at 95% confidence level.
Resumo:
This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.
Resumo:
A rapid, economical, reproducible, and simple direct spectrophotometric method was developed and validated for the assay of nitazoxanide in pharmaceutical formulations. Nitazoxanide concentration was estimated in water at 345 nm and pH 4.5. The method was suitable and validated for specificity, linearity, precision, and accuracy. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. The proposed method was successfully applied in the determination of nitazoxanide in coated tablets and in powders for oral suspension. This method was compared to a previously developed and validated method for liquid chromatography to the same drug. There was no significative difference between these methods for nitazoxanide quantitation.
Resumo:
An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.
Resumo:
A sensitive RP-HPLC method with UV detection successfully measured phenol(s) in an ointment containing 3% Stryphnodendron adstringens extract. Chromatography used acetonitrile (0.05% trifluoroacetic acid):water (0.05% trifluoroacetic acid) (v/v), flow rate 0.8 mL min-1. Quantitation was accomplished by the external-standard method. Linearity for 2.00 to 16.00 μg mL-1 (gallic acid) and 1.14 to 18.24 μg mL-1 (gallocatechin) was established. Intra- and inter-day precision levels were under 5%. LOD and LOQ were 0.231 and 0.770 μg mL-1 (gallic acid) and 0.151 and 0.504 μg mL-1 (gallocatechin), respectively. Determination of phenols was unaffected by product excipients.
Resumo:
An isocratic reversed phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the simultaneous determination of gemifloxacin and diuretics (hydrochlorothiazide and furosemide) in bulk, dosage formulations and human serum at 232 nm. Chromatographic separation was achieved on Purospher Start C18 (250 mm x 4.6 mm, 5 µm) column using mobile phase, methanol: water: acetonitrile (70:25:5 v/v/v) adjusted to pH 3.0 via phosphoric acid 85% having flow rate of 0.8 mL min -1 at room temperature. Calibration curves were linear over range of 0.5-10 µg mL -1 with a correlation coefficient ± 0.999. LOD and LOQ were in the ranges of 0.75-2.56 µg mL -1. Intra and inter-run precision and accuracy results were 98.26 to 100.9.