940 resultados para Offshore electric power plants.
Resumo:
Analytical solution is presented to convert a given driving-point impedance function (in s-domain) into a physically realisable ladder network with inductive coupling between any two sections and losses considered. The number of sections in the ladder network can vary, but its topology is assumed fixed. A study of the coefficients of the numerator and denominator polynomials of the driving-point impedance function of the ladder network, for increasing number of sections, led to the identification of certain coefficients, which exhibit very special properties. Generalised expressions for these specific coefficients have also been derived. Exploiting their properties, it is demonstrated that the synthesis method essentially turns out to be an exercise of solving a set of linear, simultaneous, algebraic equations, whose solution directly yields the ladder network elements. The proposed solution is novel, simple and guarantees a unique network. Presently, the formulation can synthesise a unique ladder network up to six sections.
Resumo:
This paper presents a methodology for selection of static VAR compensator location based on static voltage stability analysis of power systems. The analysis presented here uses the L-index of load buses, which includes voltage stability information of a normal load flow and is in the range of 0 (no load of system) to 1 (voltage collapse). An approach has been presented to select a suitable size and location of static VAR compensator in an EHV network for system voltage stability improvement. The proposed approach has been tested under simulated conditions on a few power systems and the results for a sample radial network and a 24-node equivalent EHV power network of a practical system are presented for illustration purposes. © 2000 Published by Elsevier Science S.A. All rights reserved.
Resumo:
Electric power utilities are installing distribution automation systems (DAS) for better management and control of the distribution networks during the recent past. The success of DAS, largely depends on the availability of reliable database of the control centre and thus requires an efficient state estimation (SE) solution technique. This paper presents an efficient and robust three-phase SE algorithm for application to radial distribution networks. This method exploits the radial nature of the network and uses forward and backward propagation scheme to estimate the line flows, node voltage and loads at each node, based on the measured quantities. The SE cannot be executed without adequate number of measurements. The extension of the method to the network observability analysis and bad data detection is also discussed. The proposed method has been tested to analyze several practical distribution networks of various voltage levels and also having high R:X ratio of lines. The results for a typical network are presented for illustration purposes. © 2000 Elsevier Science S.A. All rights reserved.
Resumo:
Electric power systems are exposed to various contingencies. Network contingencies often contribute to over-loading of network branches, unsatisfactory voltages and also leading to problems of stability/voltage collapse. To maintain security of the systems, it is desirable to estimate the effect of contingencies and plan suitable measures to improve system security/stability. This paper presents an approach for selection of unified power flow controller (UPFC) suitable locations considering normal and network contingencies after evaluating the degree of severity of the contingencies. The ranking is evaluated using composite criteria based fuzzy logic for eliminating masking effect. The fuzzy approach, in addition to real power loadings and bus voltage violations, voltage stability indices at the load buses also used as the post-contingent quantities to evaluate the network contingency ranking. The selection of UPFC suitable locations uses the criteria on the basis of improved system security/stability. The proposed approach for selection of UPFC suitable locations has been tested under simulated conditions on a few power systems and the results for a 24-node real-life equivalent EHV power network and 39-node New England (modified) test system are presented for illustration purposes.
Resumo:
This paper proposes a new approach for solving the state estimation problem. The approach is aimed at producing a robust estimator that rejects bad data, even if they are associated with leverage-point measurements. This is achieved by solving a sequence of Linear Programming (LP) problems. Optimization is carried via a new algorithm which is a combination of “upper bound optimization technique" and “an improved algorithm for discrete linear approximation". In this formulation of the LP problem, in addition to the constraints corresponding to the measurement set, constraints corresponding to bounds of state variables are also involved, which enables the LP problem more efficient in rejecting bad data, even if they are associated with leverage-point measurements. Results of the proposed estimator on IEEE 39-bus system and a 24-bus EHV equivalent system of the southern Indian grid are presented for illustrative purpose.
Resumo:
A lightning strike in the neighborhood can induce significant currents in tall down conductors. Though the magnitude of induced current in this case is much smaller than that encountered during a direct strike, the probability of occurrence and the frequency content is higher. In view of this, appropriate knowledge on the characteristics of such induced currents is relevant for the scrutiny of the recorded currents and in the evaluation of interference to the electrical and electronic system in the vicinity. Previously, a study was carried out on characteristics of induced currents assuming ideal conditions, that there were no influencing objects in the vicinity of the down conductor and channel. However, some influencing conducting bodies will always be present, such as trees, electricity and communication towers, buildings, and other elevated objects that can affect the induced currents in a down conductor. The present work is carried out to understand the influence of nearby conducting objects on the characteristics of induced currents due to a strike to ground in the vicinity of a tall down conductor. For the study, an electromagnetic model is employed to model the down conductor, channel, and neighboring conducting objects, and Numerical Electromagnetic Code-2 is used for numerical field computations. Neighboring objects of different heights, of different shapes, and at different locations are considered. It is found that the neighboring objects have significant influence on the magnitude and nature of induced currents in a down conductor when the height of the nearby conducting object is comparable to that of the down conductor.
Resumo:
The Radio Interference (RI) from electric power transmission line hardware, if not controlled, poses serious electromagnetic interference to system in the vicinity. The present work mainly concerns with the RI from the insulator string along with the associated line hardware. The laboratory testing for the RI levels are carried out through the measurement of the conducted radio interference levels. However such measurements do not really locate the coronating point, as well as, the mode of corona. At the same time experience shows that it is rather difficult to locate the coronating points by mere inspection. After a thorough look into the intricacies of the problem, it is ascertained that the measurement of associated ground end currents could give a better picture of the prevailing corona modes and their intensities. A study on the same is attempted in the present work. Various intricacies of the problem,features of ground end current pulses and its correlation with RI are dealt with. Owing to the complexity of such experimental investigations, the study made is not fully complete nevertheless it seems to be first of its kind.
Resumo:
Ionic Polymer Metal Composites (IPMCs) are a class of Electro-Active Polymers (EAPs) consisting of a base polymer (usually Nafion), sandwiched between thin films of electrodes and an electrolyte. Apart from fuel cell like proton exchange process in Nafion, these IPMCs can act both as an actuator and a sensor. Typically, IPMCs have been known for their applications in fuel cell technology and in artificial muscles for robots. However, more recently, sensing properties of IPMC have opened up possibilities of mechanical energy harvesting. In this paper, we consider a bi-layer stack of IPMC membranes where fluid flow induced cyclic oscillation allows collection of electronic charge across a pair of functionalized electrode on the surface of IPMC layers/stacks. IPMCs work well in hydrated environment; more specifically, in presence of an electrolyte, and therefore, have great potential in underwater applications like hydrodynamic energy harvesting. Hydrodynamic forces produce bending deformation, which can induce transport of cations via polymer chains of the base polymer of Nafion or PTFE. In our experimental set-up, the deformation is induced into the array of IPMC membranes immersed in electrolyte by water waves caused by a plunger connected to a stepper motor. The frequency and amplitude of the water waves is controlled by the stepper motor through a micro-controller. The generated electric power is measured across a resistive load. Few orders of magnitude increase in the harvested power density is observed. Analytical modeling approach used for power and efficiency calculations are discussed. The observed electro-mechanical performance promises a host of underwater energy harvesting applications.
Resumo:
Ideally, it is desirable to design and manufacture a transformer winding that can render all its internal resonances non-excitable. This study examines the effectiveness of an interleaved winding in achieving this goal. While investigating its effectiveness, it led to the establishment of a much desired theoretical basis that reinforces the reasons put forward in the literature to explain internal insulation failures observed in interleaved windings used in extra high voltage (EHV) transformers. Numerical calculations along with experimental verification on actual transformer windings are presented. This study reveals that most of the natural frequencies that are normally non-excitable in the line and neutral current responses of an interleaved winding have been rendered excitable in the disk-to-disk voltages, thus, providing favourable conditions for insulation overstress because of resonant overvoltages. Prevalence of such a condition is an inherent characteristic of interleaved windings.
Resumo:
In recent years new emphasis has been placed on problems of the environmental aspects of waste disposal, especially investigating alternatives to landfill, sea dumping and incineration. There is also a strong emphasis on clean, economic and efficient processes for electric power generation. These two topics may at first appear unrelated. Nevertheless, the technological advances are now such that a solution to both can be combined in a novel approach to power generation based on waste-derived fuels, including refuse-derived fuel (RDF) and sludge power (SP) by utilising a slagging gasifier and advance fuel technology (AFT). The most appropriate gasification technique for such waste utilisation is the British Gas/Lurgi (BGL) high pressure, fixed bed slagging gasifier where operation on a range of feedstocks has been well-documented. This gasifier is particularly amenable to briquette fuel feeding and, operating in an integrated gasification combined cycle mode (IGCC), is particularly advantageous. Here, the author details how this technology has been applied to Britain's first AFT-IGCC Power Station which is now under development at Fife Energy Ltd., in Scotland, the former British Gas Westfield Development Centre.
Resumo:
The effect of structure height on the lightning striking distance is estimated using a lightning strike model that takes into account the effect of connecting leaders. According to the results, the lightning striking distance may differ significantly from the values assumed in the IEC standard for structure heights beyond 30m. However, for structure heights smaller than about 30m, the results show that the values assumed by IEC do not differ significantly from the predictions based on a lightning attachment model taking into account the effect of connecting leaders. However, since IEC assumes a smaller striking distance than the ones predicted by the adopted model one can conclude that the safety is not compromised in adhering to the IEC standard. Results obtained from the model are also compared with Collection Volume Method (CVM) and other commonly used lightning attachment models available in the literature. The results show that in the case of CVM the calculated attractive distances are much larger than the ones obtained using the physically based lightning attachment models. This indicates the possibility of compromising the lightning protection procedures when using CVM. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
The DC capacitor is an important component in a voltage source inverter.The RMS current flowing through the capacitor determines the capacitor size and losses. The losses, in turn, influence the capacitor life. This paper proposes a space vector based modulation strategy for reducing the capacitor RMS current in a three-level diode-clamped inverter. An analytical closed-form expression is derived for the DC capacitor RMS current with the proposed PWM strategy. The analytical expression is validated through simulations and also experimentally. Theoretical and experimental results are presented, comparing the proposed strategy with conventional space vector PWM (CSVPWM). It is shown that the proposed strategy reduces the capacitor RMS current significantly at high modulation indices and high power factors. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Developing countries constantly face the challenge of reliably matching electricity supply to increasing consumer demand. The traditional policy decisions of increasing supply and reducing demand centrally, by building new power plants and/or load shedding, have been insufficient. Locally installed microgrids along with consumer demand response can be suitable decentralized options to augment the centralized grid based systems and plug the demand-supply gap. The objectives of this paper are to: (1) develop a framework to identify the appropriate decentralized energy options for demand supply matching within a community, and, (2) determine which of these options can suitably plug the existing demand-supply gap at varying levels of grid unavailability. A scenario analysis framework is developed to identify and assess the impact of different decentralized energy options at a community level and demonstrated for a typical urban residential community Vijayanagar, Bangalore in India. A combination of LPG based CHP microgrid and proactive demand response by the community is the appropriate option that enables the Vijayanagar community to meet its energy needs 24/7 in a reliable, cost-effective manner. The paper concludes with an enumeration of the barriers and feasible strategies for the implementation of community microgrids in India based on stakeholder inputs. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Solar photovoltaic power plants are ideally located in regions with high insolation levels. Photovoltaic performance is affected by high cell temperatures, soiling, mismatch and other balance-of-systems related losses. It is crucial to understand the significance of each of these losses on system performance. Soiling, highly dependent on installation conditions, is a complex performance issue to accurately quantify. The settlement of dust on panel surfaces may or may not be uniform depending on local terrain and environmental factors such as ambient temperature, wind and rainfall. It is essential to investigate the influence of dust settlement on the operating characteristics of photovoltaic systems to better understand losses in performance attributable to soiling. The current voltage (I-V) characteristics of photovoltaic panels reveal extensive information to support degradation analysis of the panels. This paper attempts to understand performance losses due to dust through a dynamic study into the I-V characteristics of panels under varying soiling conditions in an outdoor experimental test-bed. Further, the results of an indoor study simulating the performance of photovoltaic panels under different dust deposition regimes are discussed in this paper. (C) 2014 Monto Mani. Published by Elsevier Ltd. This is all open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
Resumo:
The explanation of resonance given in IEEE Std C57.149-2012 to define resonance during frequency response analysis (FRA) measurements on transformers implicitly uses the conditions prevalent during resonance in a series R-L-C circuit. This dependence is evident from the two assertions made in the definition, viz., resulting in zero net reactive impedance, and, accompanied by a zero value appearing in the phase angle of the frequency response function. These two conditions are satisfied (at resonance) only in a series R-L-C circuit and certainly not in a transformer, as has been assumed in the Standard. This can be proved by considering a ladder-network model. Circuit analysis of this ladder network reveals the origin of this fallacy and proves that, at resonance, neither is the ladder network purely resistive and nor is the phase angle (between input voltage and input current) always zero. Also, during FRA measurements, it is often seen that phase angle does not traverse the conventional cyclic path from +90 degrees to -90 degrees (or vice versa) at all resonant frequencies. This peculiar feature can also be explained using pole-zero maps. Simple derivations, simulations and experimental results on an actual winding are presented. In summary, authors believe that this study dispels existing misconceptions about definition of FRA resonance and provides material for its correction in IEEE Std C57.149-2012. (C) 2014 Elsevier B.V. All rights reserved.