860 resultados para Knowledge Technologies and Applications
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT This thesis describes a detailed study of advanced optical fibre sensors based on fibre Bragg grating (FBG), tilted fibre Bragg grating (TFBG) and long-period grating (LPG) and their applications in optical communications and sensing. The major contributions presented in this thesis are summarised below.The most important contribution from the research work presented in this thesis is the implementation of in-fibre grating based refractive index (RI) sensors, which could be the good candidates for optical biochemical sensing. Several fibre grating based RI sensors have been proposed and demonstrated by exploring novel grating structures and different fibre types, and employing efficient hydrofluoric acid etching technique to enhance the RI sensitivity. All the RI devices discussed in this thesis have been used to measure the concentration of sugar solution to simulate the chemical sensing. Efforts have also been made to overcome the RI-temperature cross-sensitivity for practical application. The demonstrated in-fibre grating based RI sensors could be further implemented as potential optical biosensors by applying bioactive coatings to realise high bio-sensitivity and bio-selectivity.Another major contribution of this thesis is the application of TFBGs. A prototype interrogation system by the use of TFBG with CCD-array was implemented to perform wavelength division multiplexing (WDM) interrogation around 800nm wavelength region with the advantages of compact size, fast detection speed and low-cost. As a high light, a novel in-fibre twist sensors utilising strong polarisation dependant coupling behaviour of an 81°-TFBG was presented to demonstrate the high torsion sensitivity and capability of direction recognition.
Resumo:
We contend that powerful group studies can be conducted using magnetoencephalography (MEG), which can provide useful insights into the approximate distribution of the neural activity detected with MEG without requiring magnetic resonance imaging (MRI) for each participant. Instead, a participant's MRI is approximated with one chosen as a best match on the basis of the scalp surface from a database of available MRIs. Because large inter-individual variability in sulcal and gyral patterns is an inherent source of blurring in studies using grouped functional activity, the additional error introduced by this approximation procedure has little effect on the group results, and offers a sufficiently close approximation to that of the participants to yield a good indication of the true distribution of the grouped neural activity. T1-weighted MRIs of 28 adults were acquired in a variety of MR systems. An artificial functional image was prepared for each person in which eight 5 × 5 × 5 mm regions of brain activation were simulated. Spatial normalisation was applied to each image using transformations calculated using SPM99 with (1) the participant's actual MRI, and (2) the best matched MRI substituted from those of the other 27 participants. The distribution of distances between the locations of points using real and substituted MRIs had a modal value of 6 mm with 90% of cases falling below 12.5 mm. The effects of this -approach on real grouped SAM source imaging of MEG data in a verbal fluency task are also shown. The distribution of MEG activity in the estimated average response is very similar to that produced when using the real MRIs. © 2003 Wiley-Liss, Inc.
Resumo:
Aromatic and aliphatic diacid chlorides were used to condense naturally occurring diamino acids and their esterified derivatives. It was anticipated the resulting functional polyamides would biodegrade to physiologically acceptable compounds and show pH dependant solubility could be used for biomedical applications ranging from enteric coatings to hydrosoluble drug delivery vehicles capable of targeting areas of low physiological pH. With these applications in mind the polymers were characterised by infra red spectroscopy, gel permeation chromatography and in the case of aqueous soluble polymers by potentiometric titration. Thin films of poly (lysine ethyl ester isophthalamide) plasticised with poly (caprolactone) were cast from DMSO/chloroform solutions and their mechanical properties measured on a Hounsfield Hti tensiometer. Interfacial synthesis was investigated as a synthetic route for the production of linear functional polyamides. High molecular weight polymer was obtained only when esterified diamino acids were condensed with aromatic diacid chlorides. The method was unsuitable for the production of copolymers of free and esterified amino acids with a diacid chloride. A novel miscible mixed solvent single phase reaction was investigated for production of copolymers of esterified and non-esterified amino acids with diacid chlorides. Aliphatic diacid chlorides were unsuitable for condensing diamino acids using this technique because of high rates of hydrolysis. The technique gave high molecular weight homopolymers from esterified diamino acids and aromatic diacid chlorides.
Resumo:
The objective of the research carried out in this report was to observe the first ever in-situ sonochemical reaction in the NMR Spectrometer in the megahertz region of ultrasound. Several reactions were investigated as potential systems for a sonochemical reaction followed by NMR spectroscopy. The primary problem to resolve when applying ultrasound to a chemical reaction is that of heating. Ultrasound causes the liquid to move and produces 'hot spots' resulting in an increase in sample temperature. The problem was confronted by producing a device that would counteract this effect and so remove the need to account for heating. However, the design of the device limited the length of time during which it would function. Longer reaction times were required to enable observations to be carried out in the NMR spectrometer. The fIrst and most obvious reactions attempted were those of the well-known ultrasonic dosimeter. Such a reaction would, theoretically, enable the author to simultaneously observe a reaction and determine the exact power entering the system for direct comparison of results. Unfortunately, in order to monitor the reactions in the NMR spectrometer the reactant concentrations had to be signifIcantly increased, which resulted in a notable increase in reaction time, making the experiment too lengthy to follow in the time allocated. The Diels-Alder Reaction is probably one of the most highly investigated reaction systems in the field of chemistry and it was this to which the author turned her attention. Previous authors have carried out ultrasonic investigations, with considerable success, for the reaction of anthracene with maleic anhydride. It was this reaction in particular that was next attempted. The first ever sonochemically enhanced reaction using a frequency of ultrasound in the megahertz (MHz) region was successfully carried out as bench experiments. Due to the complexity of the component reactants the product would precipitate from the solution and because the reaction could only be monitored by its formation, it was not possible to observe the reaction in the NMR spectrometer. The solvolysis of 2-chloro-2-methylpropane was examined in various solvent systems; the most suitable of which was determined to be aqueous 2-methylpropan-2-ol. The experiment was successfully enhanced by the application of ultrasound and monitored in-situ in the NMR spectrometer. The increase in product formation of an ultrasonic reaction over that of a traditional thermal reaction occurred. A range of 1.4 to 2.9 fold improvement was noted, dependent upon the reaction conditions investigated. An investigation into the effect of sonication upon a large biological molecule, in this case aqueous lysozyme, was carried out. An easily observed effect upon the sample was noted but no explanation for the observed effects could be established.
Resumo:
Recent advances in technology have produced a significant increase in the availability of free sensor data over the Internet. With affordable weather monitoring stations now available to individual meteorology enthusiasts a reservoir of real time data such as temperature, rainfall and wind speed can now be obtained for most of the United States and Europe. Despite the abundance of available data, obtaining useable information about the weather in your local neighbourhood requires complex processing that poses several challenges. This paper discusses a collection of technologies and applications that harvest, refine and process this data, culminating in information that has been tailored toward the user. In this case we are particularly interested in allowing a user to make direct queries about the weather at any location, even when this is not directly instrumented, using interpolation methods. We also consider how the uncertainty that the interpolation introduces can then be communicated to the user of the system, using UncertML, a developing standard for uncertainty representation.
Resumo:
The deposition efficiencies of a number of electroless nickel and cobalt plating solutions were studied and in the case of nickel compared with a commercial plating solution Nifoss 80. At the optimum plating conditions (92ºC and pH 4.5) Nifoss 80 produced nickel layers most efficiently, the alkaline cobalt solution operated most efficiently at 90ºC and pH 9. The methods of producing compostte layers containing 2-3 µm carbide particles and chromium powder is described. Nickel and cobalt layers containing approximately 27% carbide particles, or 40% (Ni) and 30% (Co) chromium particles by volume were obtained. This value is independent of the particle concentration in the plating solution within the range (20~200 g/l). Hardness of the nickel. as deposited was 515 Hv, this was increased to a maximum of 1155 Hv by heat treatment at 200ºC for 5 hours in vacuum. Incorporation. of .chromium carbide particles resulted in a maximum hardness of 1225 Hv after heating at 500ºC for 5 hours in vacuum and chromium particles resulted in a maximum hardness of 16S0 Hv after heat treatment at 400ºC for 2 hours in vacuum. Similarly the hardness of cobalt as deposited was 600 Hv, this was increased to a maximum of 1300 Hv after heat treatment at 400ºC for 1 hour. Incorporation of chromium carbide particles resulted jn a maximum hardness of 1405 Hv after heating at 400ºC for 5 hours in vacuum and chromium particles resulted in a maximum hardness of 1440 Hv after. heat treating for 2 hours at 400ºC in vacuum. The structure of the deposits was studied by optical and scanning electron microscopy. The wear rate and coefficient of friction was determined by a pin and disc method. Wear rate and coefficient of friction decreased with increase in hardness. The wear resistance of the materials was also determined using a simulated forging test. Dies made of standard die steel were coated and the wear rates of the layers as deposited and after heat treatment were compared with those of uncoated tools. The wear resistance generally increased with hardness, it was 50-75% more than the uncoated die steel. Acetic acid salt spray test and outdoor exposure for six months was used to study the corrosion behaviour of the deposits and potentiodynamic curves plotted to find their corrosion potential. Nickel deposit exhibited less staining than carbide composite deposits and nickel-chromium deposits had the most noble corrosion potential.
Resumo:
Regenerative medicine technologies have the potential to revolutionise human healthcare. However, whilst science has revealed the potential, and early products have shown the power of such therapies, there is now a need for the long-term supply of human stem cells in sufficient numbers to create reproducible and cost effective therapeutic products. The industrial platforms to be developed for human cell culture are in some ways analogous to those already developed for biopharmaceutical production using mammalian cells at large scales. However, there are a number of unique challenges that need to be addressed, largely because the quality of the cell is paramount, rather than the proteins that they express. © 2013 Elsevier Ltd.
Resumo:
In this paper we report a comparative analysis of the factors which contribute to the innovation performance of manufacturing firms in the US state of Georgia, and three European regions, the UK regions of Wales and the West Midlands, and the Spanish region of Catalonia. We consider the factors which shape firms’ ability to generate new products and processes and undertake various forms of organisational and structural change. We are particularly concerned with how firms collect the knowledge on which they base their innovation and their effectiveness in translating that knowledge into new innovations. Three main empirical conclusions result. First, US firms have more widespread links to external knowledge sources than those in Europe and notably the universities make a greater contribution to innovation in the US than in Europe. Second, UK firms prove more effective at capturing synergies between their innovation activities than US and Catalan firms. Third, firms’ operating environment proves more conducive to innovation in the US than in either the UK regions or Catalonia. Our results suggest the potential for mutual learning. For the UK there are lessons in terms of the way in which the universities in Georgia are supporting innovation. For firms in Georgia and in Catalonia the potential lessons are more strategic or organisational and relate to how they can better capture potential synergies between their innovation activities.
Resumo:
Recent advances in technology have produced a significant increase in the availability of free sensor data over the Internet. With affordable weather monitoring stations now available to individual meteorology enthusiasts a reservoir of real time data such as temperature, rainfall and wind speed can now be obtained for most of the United States and Europe. Despite the abundance of available data, obtaining useable information about the weather in your local neighbourhood requires complex processing that poses several challenges. This paper discusses a collection of technologies and applications that harvest, refine and process this data, culminating in information that has been tailored toward the user. In this case we are particularly interested in allowing a user to make direct queries about the weather at any location, even when this is not directly instrumented, using interpolation methods. We also consider how the uncertainty that the interpolation introduces can then be communicated to the user of the system, using UncertML, a developing standard for uncertainty representation.
Resumo:
We have UV-inscribed and theoretically and experimentally analyzed fiber gratings with the structure tilted at 45° and implemented this type of devices as an in-fiber polarizer. A systematic investigation has been carried out on the characterization of 45° tilted fiber gratings (45° TFGs) in terms of the polarization-dependant loss (PDL) and thermal response. The detailed theoretical modeling has revealed a linear correlation between the grating length and the PDL, which has been proved by the experimental results. For the first time, we have examined the UV beam diffraction from a tilted phase mask and designed the UV-inscription system to suit the 45° TFG fabrication. Experimentally, a 24 mm long 45° TFG UV-inscribed in standard telecom single-mode fiber exhibited around 25 dB PDL at 1530 nm and an over ~300 nm bandwidth of PDL spectrum. By the concatenation method, a 44 mm long grating showed a PDL as high as 40 dB that is close to the high polarization extinction ratio of commercial products. Moreover, we have revealed that the PDL of 45° TFGs has low thermal influence, which is desirable for real application devices. Finally, we experimentally demonstrated an all-fiber twist sensor system based on a 45° and an 81° TFG.
Resumo:
The energy consumption and the energy efficiency have become very important issue in optimizing the current as well as in designing the future telecommunications networks. The energy and power metrics are being introduced in order to enable assessment and comparison of the energy consumption and power efficiency of the telecommunications networks and other transmission equipment. The standardization of the energy and power metrics is a significant ongoing activity aiming to define the baseline energy and power metrics for the telecommunications systems. This article provides an up-to-date overview of the energy and power metrics being proposed by the various standardization bodies and subsequently adopted worldwide by the equipment manufacturers and the network operators. © Institut Télécom and Springer-Verlag 2012.and Springer-Verlag 2012.