905 resultados para Fpga devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. For accurate resection of nonpalpable malignant breast lesions with a tumor-free resection rim, an exact and stable wire localization is essential. We tested the resistance towards traction force of different localization devices used in our clinic for breast lesions in two types of tissue. Materials and Methods. Eight different commercially available hook-wire devices were examined for resistance towards traction force using an analogue spring scale. Results. Most systems showed a high level of movement already under small traction force. Retractable systems with round hooks such as the Bard DuaLok , the Fil d'Ariane, and the RPLN Breast Localization Device withstood less traction force than the other systems. However, the Bard DuaLok system was very resistant towards a small traction force of 50 g when compared to the other systems. The Ultrawire Breast Localization Device withstood the most traction force in softer tissue and Kopans Breast Lesion Localization Needle withstood the most force in harder tissue. Conclusion. The Ultrawire Breast Localization Device and Kopans Breast Lesion Localization Needle withstood the most traction force. In general retractable systems withstand less traction force than nonretractable systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many end-stage heart failure patients are not eligible to undergo heart transplantation due to organ shortage, and even those under consideration for transplantation might suffer long waiting periods. A better understanding of the hemodynamic impact of left ventricular assist devices (LVAD) on the cardiovascular system is therefore of great interest. Computational fluid dynamics (CFD) simulations give the opportunity to study the hemodynamics in this patient population using clinical imaging data such as computed tomographic angiography. This article reviews a recent study series involving patients with pulsatile and constant-flow LVAD devices in which CFD simulations were used to qualitatively and quantitatively assess blood flow dynamics in the thoracic aorta, demonstrating its potential to enhance the information available from medical imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this open, prospective, randomised, controlled trial we compared three CPR feedback devices (PocketCPR, CPRmeter, iPhone app PocketCPR) with standard BLS without feedback in a simulated scenario. 240 trained medical students performed single rescuer BLS on a manikin for 8min. Effective compression (compressions with correct depth, pressure point and sufficient decompression) as well as compression rate, flow time fraction and ventilation parameters were compared between the four groups. RESULTS Study participants using the PocketCPR performed 17±19% effective compressions compared to 32±28% with CPRmeter, 25±27% with the iPhone app PocketCPR, and 35±30% applying standard BLS (PocketCPR vs. CPRmeter p=0.007, PocketCPR vs. standard BLS p=0.001, others: ns). PocketCPR and CPRmeter prevented a decline in effective compression over time, but overall performance in the PocketCPR group was considerably inferior to standard BLS. Compression depth and rate were within the range recommended in the guidelines in all groups. CONCLUSION While we found differences between the investigated CPR feedback devices, overall BLS quality was suboptimal in all groups. Surprisingly, effective compression was not improved by any CPR feedback device compared to standard BLS. All feedback devices caused substantial delay in starting CPR, which may worsen outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several recent prospective randomized controlled trials of endovascular stroke therapy using latest generation thrombectomy devices, so called stent-retrievers, have shown significantly improved clinical outcome compared to the standard treatment with intra-venous thrombolysis using r-tPA alone. Despite some differences in inclusion criteria between these studies, all required non-invasive vessel imaging to proof occlusion of a major brain supplying vessel. Furthermore, in most studies additional imaging techniques were used to exclude patients with already established large cerebral infarction or unfavorable collateral or penumbral status. Patients with small infarct volume, severe neurological deficits and in whom thrombectomy can be initiated within the first 6 hours after symptom onset seem to benefit the most. Therefore, mechanical thrombectomy using stent-retrievers in addition to intra-venous thrombolysis is recommended for the treatment of acute ischemic stroke with proven major vessel occlusion in the anterior circulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aims of the present study in Swiss dental practices were 1) to provide an update on the prevalence of different magnification devices, 2) to examine the relationship between self-assessed and objectively measured visual acuity, and 3) to evaluate the visual performance of dentists in the individually optimized clinical situation of their respective practices. METHODS AND MATERIALS Sixty-nine dentists from 40 randomly selected private practices (n=20, <40 years; n=49, ≥40 years) participated in the study. A questionnaire was provided to evaluate the self-assessed near visual acuity and the experience with magnification devices. The objective near visual acuity was measured under standardized conditions on a negatoscope. The clinical situation, including the use of habitual optical aids, was evaluated with visual tests on a phantom head. RESULTS A total of 64% of the dentists owned a dental loupe: 45% Galilean loupes, 16% Keplerian loupes, and 3% single lens loupes. In total, 19% of the questioned dentists owned a microscope in addition to the loupes. The correlation between the self-assessed and the objective visual performance of the dentists was weak (Spearman rank correlation coefficient=0.25). In the habitual clinical situation, magnification devices (p=0.03) and the dentist's age (p=0.0012) had a significant influence on the visual performance. CONCLUSIONS Many dentists were not aware of their visual handicaps. Optical aids such as loupes or microscopes should be used early enough to compensate for individual or age-related visual deficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Web surveys are becoming increasingly popular in survey research including stated preference surveys. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. This is the first study that tests whether the use of mobile devices, tablets or smartphones, affects survey characteristics and stated preferences in a web-based choice experiment. The web survey on expanding renewable energy production in Germany was carried out with 3182 respondents, of which 12% used a mobile device. Propensity score matching is used to account for selection bias in the use of mobile devices for survey completion. We find that mobile device users spent more time than desktop/laptop users to answer the survey. Yet, desktop/laptop users and mobile device users do not differ in acquiescence tendency as an indicator of extreme response patterns. For mobile device users only, we find a negative correlation between screen size and interview length and a positive correlation between screen size and acquiescence tendency. In the choice experiment data, we do not find significant differences in the tendency to choose the status quo option and scale between both subsamples. However, some of the estimates of implicit prices differ, albeit not in a unidirectional fashion. Model results for mobile device users indicate a U-shaped relationship between error variance and screen size. Together, the results suggest that using mobile devices is not detrimental to survey quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Birth defects occur in 1 of every 33 babies born in the United States, and are the leading cause of infant death. Mothers using contraceptives that become pregnant may continue to use their contraceptives after their first missed menstrual period, thus exposing their baby in utero to the contraceptive product. Progesterone is also sometimes prescribed during the first trimester of pregnancy to mothers with a history of miscarriages or infertility problems. To ensure the safety of these products, it is important to investigate whether there is an increased occurrence of babies born with birth defects to mothers using various contraceptive methods or progesterone in early pregnancy. Using data from the National Birth Defects Prevention Study (NBDPS), an ongoing multi-state, population based case-control study, this study assessed maternal exposures to IUDs, spermicides, condoms and progesterone in early pregnancy. ^ Progesterone used for threatened miscarriage during the first three months of pregnancy was associated with an increased occurrence of hypoplastic left heart (adjusted odds ratios (OR) 2.24, 95% CI 1.13-4.21), perimembranous ventricular septal defects (OR 1.64, 95% CI 1.10-2.41), septal associations (OR 2.52, 95% CI 1.45-4.24), esophageal atresia (OR 1.82, 95% CI 1.04-3.08), and hypospadias (OR 2.12, 95% CI 1.41-3.18). Mothers using progesterone for injectable contraception had increased (OR > 2.5), but insignificant odds ratios for anencephaly, septal associations, small intestinal atresias and omphalocel. Progesterone used for fertility was not associated with an increased occurrence of any birth defects examined. ^ Mothers using progesterone for fertility assistance and threatened miscarriage were very similar with respect to their demographics and pregnancy history. They also both reported similar types of progesterone. Thus, if progesterone was a causal risk factor for birth defects we would have expected to observe similar increases in risk among mothers using progesterone for both indications. Because we predominantly observed increased associations among mothers using progesterone for threatened miscarriage but not fertility assistance, it is possible the increased associations we observed were confounded by indication (i.e. progesterone was administered for vaginal bleeding which occurred as a sequelae to the formation of a congenital anomaly. ^ No significant increased associations were observed between maternal spermicide use during pregnancy and 26 of 27 types of structural malformations. While multiple statistical tests were performed we observed first trimester maternal spermicide use to be associated with a significant increased occurrence of perimembranous ventricular septal defects (OR 2.21, 95% CI 1.16-4.21). A decreased occurrence (OR < 1.0) was observed for several categories of birth defects among mothers who conceived in the first cycle after discontinuing the use of spermicides (22 of 28) or male condoms (23 of 33). ^ Overall the percent of IUD use was similar between mothers of controls and mothers of all cases in aggregate (crude OR 1.05, 95% CI 0.61-1.84). Power was limited to detect significant associations between IUD use and birth defects, however mothers using an IUD in the month immediately prior to conception or during pregnancy were not associated with an increase of birth defects. Limb defects and amniotic band sequence previously reported to be associated with IUD use during pregnancy were not found to occur among any mothers reporting the use of an IUD during pregnancy.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The number of infections of cardiac implantable electronic devices (CIED) continues to escalate out of proportion to the increase rate of device implantation. Staphylococcal organisms account for 70% to 90% of all CIED infections. However, little is known about non-staphylococcal infections, which have been described only in case reports, small case series or combined in larger studies with staphylococcal CIED infections, thereby diluting their individual impact. ^ Methods. A retrospective review of hospital records of patients admitted with a CIED-related infections were identified within four academic hospitals in Houston, Texas between 2002 and 2009. ^ Results. Of the 504 identified patients with CIED-related infection, 80 (16%) had a non-staphylococcal infection and were the focus of this study. Although the demographics and comorbities of subjects were comparable to other reports, our study illustrates many key points: (a) the microbiologic diversity of non-staphylococcal infections was rather extensive, as it included other Gram-positive bacteria like streptococci and enterococci, a variety of Gram-negative bacteria, atypical bacteria including Nocardia and Mycobacteria, and fungi like Candida and Aspergillus; (b) the duration of CIED insertion prior to non-staphylococcal infection was relatively prolong (mean, 109 ± 27 weeks), of these 44% had their device previously manipulated within a mean of 29.5 ± 6 weeks; (c) non-staphylococcal organisms appear to be less virulent, cause prolonged clinical symptoms prior to admission (mean, 48 ± 12.8 days), and are associated with a lower mortality (4%) than staphylococcal organisms; (d) thirteen patients (16%) presented with CIED-related endocarditis; (e) although not described in prior reports, we identified 3 definite and 2 suspected cases of secondary Gram-negative bacteremia seeding of the CIED; and (f) inappropriate antimicrobial coverage was provided in approximately 50% of patients with non-staphylococcal infections for a mean period of 2.1 days. ^ Conclusions. Non-staphylococcal CIED-related infections are prevalent and diverse with a relatively low virulence and mortality rate. Since non-staphylococcal organisms are capable of secondarily seeding the CIED, a high suspicion for CIED-related infection is warranted in patients with bloodstream infection. Additionally, in patients with suspected CIED infection, adequate Gram positive and -negative antibacterial coverage should be administered until microbiologic data become available.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we propose a method for cleaving silicon-based photonic chips by using a laser based micromachining system, consisting of a ND:YVO4laser emitting at 355 nm in nanosecond pulse regime and a micropositioning system. The laser makes grooved marks placed at the desired locations and directions where cleaves have to be initiated, and after several processing steps, a crack appears and propagate along the crystallographic planes of the silicon wafer. This allows cleavage of the chips automatically and with high positioning accuracy, and provides polished vertical facets with better quality than the obtained with other cleaving process, which eases the optical characterization of photonic devices. This method has been found to be particularly useful when cleaving small-sized chips, where manual cleaving is hard to perform; and also for polymeric waveguides, whose facets get damaged or even destroyed with polishing or manual cleaving processing. Influence of length of the grooved line and speed of processing is studied for a variety of silicon chips. An application for cleaving and characterizing sol–gel waveguides is presented. The total amount of light coupled is higher than when using any other procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid crystal properties make them useful for the development of security devices in applications of authentication and detection of fakes. Induced orientation of liquid crystal molecules and birefringence are the two main properties used in security devices. Employing liquid crystal and dichroic colorants, we have developed devices that show, with the aid of a polarizer, multiple images on each side of the device. Rubbed polyimide is used as alignment layer on each substrate of the LC cell. By rubbing the polyimide in different directions in each substrate it is possible to create any kind of symbols, drawings or motifs with a greyscale; the more complex the created device is, the more difficult is to fake it. To identify the motifs it is necessary to use polarized light. Depending on whether the polarizer is located in front of the LC cell or behind it, different motifs from one or the other substrate are shown. The effect arises from the dopant colour dye added to the liquid crystal, the induced orientation and the twist structure. In practice, a grazing reflection on a dielectric surface is polarized enough to see the effect. Any LC flat panel display can obviously be used as backlight as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this paper is the presentation of modelling solutions off loating devices that can be used for harnessing energy from ocean currents. It has been structured into three main parts. First, the growing current interest in marine renewable energy in general, and in extracting energy from currents in particular, is presented, showing the large number of solutions that are emerging and some of the most significant types. GESMEY generator is presented in second section. It is based on a new concept that has been patented by the Universidad Politécnica de Madrid and which is currently being developed through a collaborative agreement with the SOERMAR Foundation. The main feature of this generator is that on operation is fully submerged, and no other facilities are required to move to floating state for maintenance, which greatly increases its performance. Third part of the article is devoted to present the modelling and simulation challenges that arise in the development of devices for harnessing the energy of marine currents, along with some solutions which have been adopted within the frame of the GESMEY Project, making particular emphasis on the dynamics of the generator and its control