677 resultados para Elastomer rods


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent developments in aerostatic thrust bearings have included: (a) the porous aerostatic thrust bearing containing a porous pad and (b) the inherently compensated compliant surface aerostatic thrust bearing containing a thin elastomer layer. Both these developments have been reported to improve the bearing load capacity compared to conventional aerostatic thrust bearings with rigid surfaces. This development is carried one stage further in a porous and compliant aerostatic thrust bearing incorporating both a porous pad and an opposing compliant surface. The thin elastomer layer forming the compliant surface is bonded to a rigid backing and is of a soft rubber like material. Such a bearing is studied experimentally and theoretically under steady state operating conditions. A mathematical model is presented to predict the bearing performance. In this model is a simplified solution to the elasticity equations for deflections of the compliant surface. Account is also taken of deflections in the porous pad due to the pressure difference across its thickness. The lubrication equations for flow in the porous pad and bearing clearance are solved by numerical finite difference methods. An iteration procedure is used to couple deflections of the compliant surface and porous pad with solutions to the lubrication equations. Comparisons between experimental results and theoretically predicted bearing performance are in good agreement. However these results show that the porous and compliant aerostatic thrust bearing performance is lower than that of a porous aerostatic thrust bearing with a rigid surface in place of the compliant surface. This discovery is accounted to the recess formed in the bearing clearance by deflections of the compliant surface and its effect on flow through the porous pad.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present thesis investigates targeted (locally and systemically) delivery of a novel group of inhibitors of enzyme transglutaminases (TGs). TGs are a widely distributed group of enzymes that catalyse the formation of isopeptide bonds between the y-carboxamide group of protein-bound glutamines and the a-amino group of protein-bound lysines or polyamines. The first group of the novel inhibitors tested were the tluorescently labelled inhibitors of Factor XIIIa (FXIIIa). These small, non-toxic inhibitors have the potential to prevent stabilisation of thrombi by FXIIIa and consequently increase the natural rate of thrombolysis, in addition it reduces staphylococcal colonisation of catheters by inhibiting their FXIIIa¬mediated cross-linking to blood clot proteins on the central venous catheter (CVCs) surface. The aim of this work was to incorporate the FXIIIa inhibitor either within coating of polyurethane (PU) catheters or to integrate it into silicone catheters, so as to reduce the incidence of thrombotic occlusion and associated bacterial infection in CVCs. The initial work focused on the incorporation of FXIIIa inhibitors within polymeric coatings of PU catheters. After defining the key characteristics desired for an effective polymeric-coating, polyvinylpyrrolidone (PVP), poly(lactic-co-glycolic acid) (PLGA) or their combination were studies as polymers of choice for coating of the catheters_ The coating was conducted by dip-coating method in a polymer solution containing the inhibitor. Upon incubation of the inhibitor-and polymer-coated strips in buffer, PVP was dissolved instantly, generating fast and significant drug release, whilst PLGA did not dissolve, yielding a slow and an insufficient amount of drug release. Nevertheless, the drug release profile was enhanced upon employing a blend solution of PVP and PLGA. The second part of the study was to incorporate the FXIIIa inhibitor into a silicone elastomer; results demonstrated that FXIIIa inhibitor can be incorporated and released from silicone by using citric acid (CA) and sodium bicarbonate (SB) as additives and the drug release rate can be controlled by the amount of incorporated additives in the silicone matrix. Furthermore, it was deemed that the inhibitor was still biologically active subsequent to being released from the silicone elastomer strips. Morphological analysis confirmed the formation of channels and cracks inside the specimens upon the addition of CA and SB. Nevertheless, the tensile strength, in addition to Young's modulus of silicone elastomer strips, decreased constantly with an increasing amount of amalgamated CA/ SB in the formulations. According to our results, incorporation of FXIIIa inhibitor into catheters and other medical implant devices could offer new perspectives in preventing bio-material associated infections and thrombosis. The use of tissue transglutaminase (T02) inhibitor for treating of liver fibrosis was also investigated. Liver fibrosis is characterized by increased synthesis and decreased degradation of the extracellular matrix (ECM). Transglutaminase-mediated covalent cross-linking is involved in the stabilization of ECM in human liver fibrosis. Thus, TG2 inhibitors may be used to counteract the decreased degradation of the ECM. The potential of a liposome based drug delivery system for site specific delivery of the fluorescent TG2 inhibitor into the liver was investigated; results indicated that the TG2 inhibitor can be successfully integrated into liposomes and delivered to the liver, therefore demonstrating that liposomes can be employed for site-specific delivery of TG2 inhibitors into the liver and TG2 inhibitor incorporating liposomes could offer a new approach in treating liver fibrosis and its end stage disease cirrhosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The wear behaviour of a series of chromium containing white irons has been investigated under conditions of high stress grinding abrasion using a specimen on track abrasion testing machine. The measured abrasion resistance of the irons has been explained in terms of microstructure and hardness and with respect to the wear damage observed at and beneath abraded surfaces. During abrasion material removal occurred by cracking and detachment from the matrix of eutectic carbides as well as by penetration and micromachining effects of the abrasive grits being crushed at the wearing surface. Under the particular test conditions used martensitic matrix structures gave higher resistance to abrasion than austenitic or pearlitic. However, no simple relationship was found between general hardness or matrix microhardness at wear surfaces and abrasion resistance, and the test yielded pessimistic results for austenitic irons. The fine structures of the 15% Cr and 30% Cr alloys were studied by thin foil transmission electron microscopy. It was found that both the matrix and carbide constituents could be thinned for examination at 100 Kv using conventional dishing followed by ion beam thinning. Flany of the rodlike eutectic N7C3 carbides were seen to consist of clusters of scalier rods with individual 117C3 crystals quite often containing central cores of matrix constituent. 3oth eutectic and secondary N7C3 carbides were found to contain stacking faults on planes normal to the basal plane. In the eutectic carbides in the 30A Cr iron there was evidence of an in-situ PI7C3 C. transition which had taken place during the hardening heat treatment of this alloy. In the as-cast austenitic matrix iron strain induced martensite was produced at the wear surface contributing to work hardening. The significance of these findings have been discussed in relation to wear performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study measured and compared the pharmacokinetics of CMPD167, a small molecule antiretroviral CCR5 inhibitor with potential as an HIV microbicide, following vaginal, rectal and oral administration in rhesus macaques. Methods: Avaginal hydroxyethylcellulose (HEC) gel, a rectal HEC gel, a silicone elastomer matrix-type vaginal ring and an oral solution, each containing CMPD167, were prepared and administered to rhesus macaques pretreated with Depo-Provera. CMPD167 concentrations in vaginal fluid, vaginal tissue (ring only), rectal fluid and blood plasma were quantified by HPLC-mass spectrometry. Results: CMPD167 concentrations measured in rectal fluid, vaginal fluid and blood plasma were highly dependent on both the route of administration and the formulation type. Although rectal and vaginal fluid concentrations were highest when CMPD167 was administered locally (via either gel or ring), lower concentrations of the drug were also measured in these compartments following administration at the remote mucosal site or orally. CMPD167 levels in the vaginal and rectal fluid following oral administration were relatively low compared with local administration. Conclusions: The study provides clear evidence for vaginal-rectal and rectal-vaginal drug transfer pathways and suggests that oral pre-exposure prophylaxis with CMPD167 may be less efficacious at preventing sexual transmission of HIV-1 than topically applied products. ©The Author 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High quality CuS and CuS/ZnS core/shell nanocrystals (NCs) were synthesized in a large quantity using a facile hydrothermal method at low temperatures of 60 C and evaluated in the photodegradation of Rhodamine B (RhB) under visible light irradiation. Synthesis time plays an important role in controlling the morphology, size and photocatalytic activity of both CuS and CuS/ZnS core/shell NCs which evolve from spherical shaped particles to form rods with increasing reaction time, and after 5 h resemble "flower" shaped morphologies in which each "flower" is composed of many NCs. Photocatalytic activity originates from photo-generated holes in the narrow bandgap CuS, with encapsulation by large bandgap ZnS layers used to form the core/shell structure that improves the resistance of CuS towards photocorrosion. Such CuS/ZnS core/shell structures exhibit much higher photocatalytic activity than CuS or ZnS NCs alone under visible light illumination, and is attributed to higher charge separation rates for the photo-generated carriers in the core/shell structure. © 2013 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poly(l-lactide) (PLL) has been blended with a polycaprolactone-based thermoplastic polyurethane (TPU) elastomer as a toughening agent and a poly(l-lactide-co-caprolactone) (PLLCL) copolymer as a compatibilizer. Both 2-component (PLL/TPU) and 3-component (PLL/TPU/PLLCL) blends were prepared by melt mixing, characterized, hot-pressed into thin sheets and their tensile properties tested. The results showed that, although the TPU could toughen the PLL, the blends were largely immiscible leading to phase separation. However, addition of the PLLCL copolymer improved blend compatibility. The best all-round properties were found for the 3-component blend of composition PLL/TPU/PLLCL = 90/10/10 parts by weight.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Heterosexual HIV transmission continues to spread worldwide. Intravaginal rings (IVRs) formulated with antiretroviral drugs hold great promise for HIV prevention in women. IVRs provide the benefit of being coitally-independent and coitally-covert for an extended period. As a proof-of-concept, we tested the in vivo release of progesterone from a silicone elastomer vaginal ring device. Methods: Six female pig-tailed macaques were treated with a GnRH agonist (Lupron) prior to ring placement. Four macaques received a progesterone-loaded silicone ring, and two macaques received a blank silicone ring. Blood, vaginal swabs, CVL, and/or biopsies were collected during ring placement, and after ring removal. Results: The median plasma progesterone levels for macaques with a progesterone IVR were 13,973 pg/ml (day 3), 12,342 pg/ml (day 7), 10,112 pg/ml (day 14), 8445 pg/ml (day 21) and 8061 pg/ml (day 28), with a significant decrease from day 14 to day 21 (P = 0.0286). The median plasma progesterone levels for macaques with a blank IVR were 221±±± ±±88 pg/ml. Macaques with a progesterone IVR had CVL progesterone levels of 20,935 pg/ml (day 7), 6892 pg/ml (day 21) and 11,515 pg/ml (day 28). Macaques with a blank IVR had CVL progesterone levels of 29 �± 13 pg/ml. There were no disturbances to the normal vaginal microflora, and plasma and CVL cytokine analysis did not indicate a proinflammatory response due to ring placement. The vaginal biopsies did not display any pathology following ring removal. Overall, the IVRs were well tolerated without any indication of inflammation or significant changes in the vaginal compartment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microtubes and rods with nanopipes of transparent conductive oxides (TCO), such as SnO_2, TiO_2, ZnO and In_2O_3, have been fabricated following a vapor-solid method which avoids the use of catalyst or templates. The morphology of the as-grown tubular structures varies as a function of the precursor powder and the parameters employed during the thermal treatments carried out under a controlled argon flow. These materials have been also doped with different elements of technological interest (Cr, Er, Li, Zn, Sn). Energy Dispersive X-ray Spectroscopy (EDS) measurements show that the concentration of the dopants achieved by the vapor-solid method ranges from 0.5 to _3 at.%. Luminescence of the tubes has been analyzed, with special attention paid to the influence of the dopants on their optical properties. In this work, we summarize and discuss some of the processes involved not only in the anisotropic growth of these hollow micro and nanostructures, but also in their doping.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chapter 2 - Cystatin C is a cationic protein is not glycosylated, produced a steady state for all nucleated and present in biological fluids cells being freely filtered by the glomeruli and almost completely catabolized in the proximal tubule, it is a promising early renal dysfunction marker. This study aimed to determine and compare the serum concentration of cystatin C biomarker in 86 dogs. The animals were divided into four groups according to serum creatinine levels: G1 - up. 1.4 mg / dL (23 animals), G2 - 1.5-2.0 mg / dL (16 animals), G3 - 2.1 to 5.0 mg / dL (24 animals) and G4 - above 5.1 mg / dL (23 animals). There was the measurement of the parameters used in the clinical routine of small animals such as urea, urinary gamma glutamyl transferase, proteinuria, alkaline phosphatase, sodium, potassium, chloride, calcium, phosphorus, calcium/phosphorus ratio and cystatin C. There was no statistical difference for urea, proteinuria, phosphorus, calcium/phosphorus, potassium and cystatin C, however, the other showed no statistical difference. Based on the results we can infer that cystatin C was not a good early indicator of kidney disease in dogs. Chapter 3 - This study aimed to determine the hematological and urinalysis elements such as density, proteinuria, cylinders and pH in 86 dogs The animals were divided into four stages according to serum creatinine levels: I - up to 1.4 mg/dL (23 animals), II - 1.5-2.0 mg/dL (16 animals), III from 2.1 to 5.0 mg/dL (24 animals) and IV - above 5.1 mg/dL (23 animals). In stage III, IV there was anemia normocytic normochromic type. Stage II had a leukocytosis frame by neutrophilia with a regenerative left shift and stage III and IV detour degenerative left. The density remained within the reference values all stages. Proteinuria showed statistical significance for the classification 2+ (1.0 g/L), between stage I and II, II and IV. Only the cylinder granular statistical difference in the classification 2+ between stage II and III, and 3+ between stage I and III. The prevailing pH was acid. The haematological values compared to serum creatinine stages showed the changes in hemoglobin and packed cell volume erythrocytes become more pronounced as serum creatinine values rise , this is also the behavior of neutrophils rods and proteinuria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biofouling, the accumulation of biomolecules, cells, organisms and their deposits on submerged and implanted surfaces, is a ubiquitous problem across various human endeavors including maritime operations, medicine, food industries and biotechnology. Since several decades, there have been substantial research efforts towards developing various types of antifouling and fouling release approaches to control bioaccumulation on man-made surfaces. In this work we hypothesized, investigated and developed dynamic change of the surface area and topology of elastomers as a general approach for biofouling management. Further, we combined dynamic surface deformation of elastomers with other existing antifouling and fouling-release approaches to develop multifunctional, pro-active biofouling control strategies.

This research work was focused on developing fundamental, new and environment-friendly approaches for biofouling management with emphasis on marine model systems and applications, but which also provided fundamental insights into the control of infectious biofilms on biomedical devices. We used different methods (mechanical stretching, electrical-actuation and pneumatic-actuation) to generate dynamic deformation of elastomer surfaces. Our initial studies showed that dynamic surface deformation methods are effective in detaching laboratory grown bacterial biofilms and barnacles. Further systematic studies revealed that a threshold critical surface strain is required to debond a biofilm from the surface, and this critical strain is dependent on the biofilm mechanical properties including adhesion energy, thickness and modulus. To test the dynamic surface deformation approach in natural environment, we conducted field studies (at Beaufort, NC) in natural seawater using pneumatic-actuation of silicone elastomer. The field studies also confirmed that a critical substrate strain is needed to detach natural biofilm accumulated in seawater. Additionally, the results from the field studies suggested that substrate modulus also affect the critical strain needed to debond biofilms. To sum up, both the laboratory and the field studies proved that dynamic surface deformation approach can effectively detach various biofilms and barnacles, and therefore offers a non-toxic and environmental friendly approach for biofouling management.

Deformable elastomer systems used in our studies are easy to fabricate and can be used as complementary approach for existing commercial strategies for biofouling control. To this end, we aimed towards developed proactive multifunctional surfaces and proposed two different approaches: (i) modification of elastomers with antifouling polymers to produce multifunctional, and (ii) incorporation of silicone-oil additives into the elastomer to enhance fouling-release performance.

In approach (i), we modified poly(vinylmethylsiloxane) elastomer surfaces with zwitterionic polymers using thiol-ene click chemistry and controlled free radical polymerization. These surfaces exhibited both fouling resistance and triggered fouling-release functionalities. The zwitterionic polymers exhibited fouling resistance over short-term (∼hours) exposure to bacteria and barnacle cyprids. The biofilms that eventually accumulated over prolonged-exposure (∼days) were easily detached by applying mechanical strain to the elastomer substrate. In approach (ii), we incorporated silicone-oil additives in deformable elastomer and studied synergistic effect of silicone-oils and surface strain on barnacle detachment. We hypothesized that incorporation of silicone-oil additive reduces the amount of surface strain needed to detach barnacles. Our experimental results supported the above hypothesis and suggested that surface-action of silicone-oils plays a major role in decreasing the strain needed to detach barnacles. Further, we also examined the effect of change in substrate modulus and showed that stiffer substrates require lower amount of strain to detach barnacles.

In summary, this study shows that (1) dynamic surface deformation can be used as an effective, environmental friendly approach for biofouling control (2) stretchable elastomer surfaces modified with anti-fouling polymers provides a pro-active, dual-mode approach for biofouling control, and (3) incorporation of silicone-oils additives into stretchable elastomers improves the fouling-release performance of dynamic surface deformation technology. Dynamic surface deformation by itself and as a supplementary approach can be utilized biofouling management in biomedical, industrial and marine applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les polygones à coin de glace sont très répandus dans la zone du pergélisol continu. Lorsque le ruissellement d’eau de fonte nivale s’infiltre de façon concentrée dans une cavité, il peut initier le processus de thermo-érosion du pergélisol (notamment des coins de glace) pouvant mener à la formation de ravins. Dans la vallée de Qalikturvik sur l’Ile Bylot (NU, Canada), le développement de ravins de thermo-érosion dans un milieu de polygones à coins de glace entraîne comme impact : i. la réorganisation des réseaux de drainage impliquant un assèchement des milieux humides en marge des chenaux d’érosion, ii. des variations dans le régime thermique et de l’humidité de proche-surface et iii. la prise en charge et le déplacement des sédiments vers l’extérieur du bassin-versant. L’objectif de cette thèse vise à approfondir les connaissances géomorphologiques propres au ravinement par thermo-érosion, d’examiner, caractériser et quantifier les impacts du ravinement (tel que sus-mentionné en i. ii. iii.) et le rôle de celui-ci dans une optique d’évolution du paysage périglaciaire à l’échelle temporelle de l’année à la décennie. Les ravins sont dynamiques : un ravin en particulier déclenché en 1999 et étudié depuis s’érodait à une vitesse de 38 à 50 m/a durant sa première décennie d’existence, pour atteindre une longueur totale de ~750 m et une surface érodée de ~25 000 m² en 2009. Des puits sont localisés près des zones de ravinement actives ; des levées alluviale, mares et polygones effondrés dans les zones stabilisées post-perturbation. Sur la terrasse de polygones recouvrant le plancher de la vallée au site à l’étude, 35 ravins furent identifiés et 1401 polygones furent perturbés avec 200 000 m³ de sols transportés. Une amélioration du drainage, une dégradation de la capacité de rétention de l’humidité, une transition d’un écoulement de ruissellement vers un écoulement canalisé caractérise les aires ravinées et leurs environs. Les polygones intacts sont homogènes d’un à l’autre et dans leurs centres ; les polygones perturbés ont une réponse hétérogène (flore, humidité et régime thermique). Les milieux érodés hétérogènes succèdent aux milieux homogènes et deviennent le nouvel état d’équilibre pour plusieurs décennies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le site routier expérimental de Beaver Creek (62º 20’ 20’’ N – 140º 50’ 10’’ O) est sis sur la moraine de Beaver Creek pré datant le Dernier Maximum Glaciaire. Dans un périmètre d’un kilomètre carré, son relief, sa végétation, son sol et sa cryostratigraphie ont été étudiés avec une perspective géosystémique, afin d’en détailler la catena et sa structure. Ensuite, la cryostratigraphie a été interprétée pour suggérer un modèle d’évolution du paysage. Enfin, les changements récents y ont été intégrés en vue d’actualiser la tendance évolutive du géosystème. Il ressort de cet ouvrage que la durabilité du pergélisol est fortement appuyée par la présence des milieux humides dans les replats. Quelques affleurements de la moraine sont toujours visibles, quoique faiblement exprimés. Ils contiennent peu de glace et leur teneur en matière organique est mince. Quant aux dépressions, elles sont peu profondes et étendues. Non seulement elles ont hérité des sédiments érodés des crêtes, mais elles ont aussi fixé une quantité importante de glace et de matière organique par le truchement d’un pergélisol syngénétique (>15 m) généré par le climat et protégé par l’écosystème. Au moins un évènement de thermo-érosion est survenu avant le dernier stade d’aggradation syngénétique (Holocène), mais il n’a été que partiel. L’actuel réchauffement climatique menace d’engager un autre épisode de dégradation à l’échelle du bassin versant. Contrairement au changement climatique, l’utilisation du territoire provoque déjà la dégradation du pergélisol, mais de manière localisée seulement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reduction in global ocean pH due to the uptake of increased atmospheric CO2 is expected to negatively affect calcifying organisms, including the planktonic larval stages of many marine invertebrates. Planktonic larvae play crucial roles in the benthic-pelagic life cycle of marine organisms by connecting and sustaining existing populations and colonizing new habitats. Calcified larvae are typically denser than seawater and rely on swimming to navigate vertically structured water columns. Larval sand dollars Dendraster excentricus have calcified skeletal rods supporting their bodies, and propel themselves with ciliated bands looped around projections called arms. Ciliated bands are also used in food capture, and filtration rate is correlated with band length. As a result, swimming and feeding performance are highly sensitive to morphological changes. When reared at an elevated PCO2 level (1000 ppm), larval sand dollars developed significantly narrower bodies at four and six-arm stages. Morphological changes also varied between four observed maternal lineages, suggesting within-population variation in sensitivity to changes in PCO2 level. Despite these morphological changes, PCO2 concentration alone had no significant effect on swimming speeds. However, acidified larvae had significantly smaller larval stomachs and bodies, suggesting reduced feeding performance. Adjustments to larval morphologies in response to ocean acidification may prioritize swimming over feeding, implying that negative consequences of ocean acidification are carried over to later developmental stages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The deposition of stiff and strong coatings onto porous templates offers a novel strategy for fabricating macroscale materials with controlled architectures at the micro- and nanoscale. Here, layer-by-layer assembly is utilized to fabricate nanocomposite-coated foams with highly customizable properties by depositing polymer–nanoclay coatings onto open-cell foam templates. The compressive mechanical behavior of these materials evolves in a predictable manner that is qualitatively captured by scaling laws for the mechanical properties of cellular materials. The observed and predicted properties span a remarkable range of density-stiffness space, extending from regions of very soft elastomer foams to very stiff, lightweight honeycomb and lattice materials.