[Book] In recent years "light architecture" has returned as an important component of contemporary architectural design. More and more architects work with lighting designers in order to develop concepts for the nocturnal appearance of their buildings. It is little known that, despite numerous recent technical developments, the vocabulary of today's lighting designers has a long history. The large world fairs of the nineteenth century were the first testing ground for architectural illumination." "This publication juxtaposes historic buildings and architectural visions with recent designs, as well as with contemporary paintings and photographs that reacted to the changing nocturnal skyline. Essays address different aspects of this aspect of architectural history.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the implications of the introduction of electric lighting systems, building technologies, and theories of worker efficiency on the deep spatial and environmental transformations that occurred within the corporate workplace during the twentieth century. Examining the shift from daylighting strategies to largely artificially lit workplace environments, this paper argues that electric lighting significantly contributed to the architectural rationalization of both office work and the modern office environment. Contesting the historical and critical marginalization of lighting within the discourse of the modern built environment, this study calls for a reassessment of the role of artificial lighting in the development of the modern corporate workplace. Keywords: daylighting, fluorescent lighting, rationalization, workplace design

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mr Mehdi Amirkhani presented his research and case studies on improved lighting design in commercial spaces through daylight control and innovative lighting placement. This technical meeting was organised by IESANZ Queensland Chapter on April 7, 2016.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the first half of the twentieth century the dematerializing of boundaries between enclosure and exposure problematized traditional acts of “occupation” and understandings of the domestic environment. As a space of escalating technological control, the modern domestic interior offered new potential to re-define the meaning and means of habitation. This shift is clearly expressed in the transformation of electric lighting technology and applications for the modern interior in the mid-twentieth century. Addressing these issues, this paper examines the critical role of electric lighting in regulating and framing both the public and private occupation of Philip Johnson’s New Canaan estate. Exploring the dialectically paired transparent Glass House and opaque Guest House (both 1949), this study illustrates how Johnson employed artificial light to control the visual environment of the estate as well as to aestheticize the performance of domestic space. Looking closely at the use of artificial light to create emotive effects as well as to intensify the experience of occupation, this revisiting of the iconic Glass House and lesser-known Guest House provides a more complex understanding of Johnson’s work and the means with which he inhabited his own architecture. Calling attention to the importance of Johnson serving as both architect and client, and his particular interest in exploring the new potential of architectural lighting in this period, this paper investigates Johnson’s use of electric light to support architectural narratives, maintain visual order and control, and to suit the nuanced desires of domestic occupation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From 23 August until 2 October 2010, the successful Richard Kelly exhibition and symposium held at the Yale Architecture School in New Haven, US drew attention to the many contributions of this pioneering designer. Luminous opens the debate with five international lighting designers on the role and relevance of Kelly's vocabulary today.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generating a cultural lighting icon on the Manhattan skyline is a big responsibility and there is no second chance to make it right. In addition, we had to balance a classic timeless lighting design for the building while responding to the lighting criteria of the Times Square district – in a time of energy awareness...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Architecture today often is praised for its tectonics, floating volumes, and sensational, gravity-defying stunts of “starchitecture.” Yet, very so often there is a building that inspires descriptions of the sublime, the experiential, and the power of light and architecture to transcend our expectations. The new Meinel Optical Sciences Research Building, designed by Phoenix-based Richärd+Bauer for the University of Arizona, Tucson, is one of these architectural rarities. Already drawing comparisons to Louis Kahn's 1965 Salk Institute for Biological Studies in La Jolla, California, the indescribable quality of light that characterizes the best of Kahn's work also resonates in Richärd+Bauer's new building. Both an expansion and renovation of the existing College of Optical Sciences facilities, the Meinel building includes teaching and research laboratories, six floors of offices, discussion areas, conference rooms, and an auditorium. The new 47,000 square-foot cast-in-place concrete structure, wrapped on three-sides in copper-alloy panels, harmonizes with the largely brick vocabulary of the campus while reflecting the ethereal quality of the wide Arizona sky. The façade, however, is merely a prelude for what awaits inside—where light and architecture seamlessly combine to create moments of pure awe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light is essential to life and vision; without light, nothing exists. It plays a pivotal role in the world of architectural design and is used to generate all manner of perceptions that enhance the designed environment experience. But what are the fundamental elements that designers rely upon to generate light enhanced experiences? How are people’s perceptions influenced by designed light schemas? In this book Dr. Marisha McAuliffe highlights the relationship that exists between light source and surface and how both create quality of effect in the built environment. Concepts relating to architectural lighting design history, theories, research, and generation of lighting design schemes to create optimal experiences in architecture, interior architecture and design are all explored in detail. This book is essential reading for both the student and the professional working in architectural lighting, particularly in terms of qualitative perception oriented lighting design

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies have shown an elevation in the incidence of asthma, allergic symptoms and respiratory infections among people living or working in buildings with moisture and mould problems. Microbial growth is suspected to have a key role, since the severity of microbial contamination and symptoms show a positive correlation, while the removal of contaminated materials relieves the symptoms. However, the cause-and-effect relationship has not been well established and knowledge of the causative agents is incomplete. The present consensus of indoor microbes relies on culture-based methods. Microbial cultivation and identification is known to provide qualitatively and quantitatively biased results, which is suspected to be one of the reasons behind the often inconsistent findings between objectively measured microbiological attributes and health. In the present study the indoor microbial communities were assessed using culture-independent, DNA based methods. Fungal and bacterial diversity was determined by amplifying and sequencing the nucITS- and16S-gene regions, correspondingly. In addition, the cell equivalent numbers of 69 mould species or groups were determined by quantitative PCR (qPCR). The results from molecular analyses were compared with results obtained using traditional plate cultivation for fungi. Using DNA-based tools, the indoor microbial diversity was found to be consistently higher and taxonomically wider than viable diversity. The dominant sequence types of fungi, and also of bacteria were mainly affiliated with well-known microbial species. However, in each building they were accompanied by various rare, uncultivable and unknown species. In both moisture-damaged and undamaged buildings the dominant fungal sequence phylotypes were affiliated with the classes Dothideomycetes (mould-like filamentous ascomycetes); Agaricomycetes (mushroom- and polypore-like filamentous basidiomycetes); Urediniomycetes (rust-like basidiomycetes); Tremellomycetes and the family Malasseziales (both yeast-like basidiomycetes). The most probable source for the majority of fungal types was the outdoor environment. In contrast, the dominant bacterial phylotypes in both damaged and undamaged buildings were affiliated with human-associated members within the phyla Actinobacteria and Firmicutes. Indications of elevated fungal diversity within potentially moisture-damage-associated fungal groups were recorded in two of the damaged buildings, while one of the buildings was characterized by an abundance of members of the Penicillium chrysogenum and P. commune species complexes. However, due to the small sample number and strong normal variation firm conclusions concerning the effect of moisture damage on the species diversity could not be made. The fungal communities in dust samples showed seasonal variation, which reflected the seasonal fluctuation of outdoor fungi. Seasonal variation of bacterial communities was less clear but to some extent attributable to the outdoor sources as well. The comparison of methods showed that clone library sequencing was a feasible method for describing the total microbial diversity, indicated a moderate quantitative correlation between sequencing and qPCR results and confirmed that culture based methods give both a qualitative and quantitative underestimate of microbial diversity in the indoor environment. However, certain important indoor fungi such as Penicillium spp. were clearly underrepresented in the sequence material, probably due to their physiological and genetic properties. Species specific qPCR was a more efficient and sensitive method for detecting and quantitating individual species than sequencing, but in order to exploit the full advantage of the method in building investigations more information is needed about the microbial species growing on damaged materials. In the present study, a new method was also developed for enhanced screening of the marker gene clone libraries. The suitability of the screening method to different kinds of microbial environments including biowaste compost material and indoor settled dusts was evaluated. The usability was found to be restricted to environments that support the growth and subsequent dominance of a small number microbial species, such as compost material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A controlled laboratory experiment was carried out on forty Indian male college students for evaluating the effect of indoor thermal environment on occupants' response and thermal comfort. During experiment, indoor temperature varied from 21 degrees C to 33 degrees C, and the variables like relative humidity, airflow, air temperature and radiant temperature were recorded along with subject's physiological parameters (skin (T-sk) and oral temperature (T-c)) and subjective thermal sensation responses (TSV). From T-sk and T-c, body temperature (T-b) was evaluated. Subjective Thermal Sensation Vote (TSV) was recorded using ASHRAE 7-point scale. In PMV model, Fanger's T-sk equation was used to accommodate adaptive response. Step-wise regression analysis result showed T-b was better predictor of TSV than T-sk and T-c. Regional skin temperature response, suppressed sweating without dipping, lower sweating threshold temperature and higher cutaneous threshold for sweating were observed as thermal adaptive responses. These adaptive responses cannot be considered in PMV model. To incorporate subjective adaptive response, mean skin temperature (T-sk) is considered in dry heat loss calculation. Along with these, PMV-model and other two methodologies are adopted to calculate PMV values and results are compared. However, recent literature is limited to measure the sweat rate in Indians and consideration of constant Ersw in PMV model needs to be corrected. Using measured T-sk in PMV model (Method(1)), thermal comfort zone corresponding to 0.5 <= PMV <= 0.5 was evaluated as (22.46-25.41) degrees C with neutral temperature of 23.91 degrees C, similarly while using TSV response, wider comfort zone was estimated as (23.25-26.32) degrees C with neutral temperature at 24.83 degrees C, which was further increased to with TSV-PPDnew, relation. It was observed that PMV-model overestimated the actual thermal response. Interestingly, these subjects were found to be less sensitive to hot but more sensitive to cold. A new TSV-PPD relation (PPDnew) was obtained from the population distribution of TSV response with an asymmetric distribution of hot-cold thermal sensation response from Indians. The calculations of human thermal stress according to steady state energy balance models used on PMV model seem to be inadequate to evaluate human thermal sensation of Indians. Relevance to industry: The purpose of this paper is to estimate thermal comfort zone and optimum temperature for Indians. It also highlights that PMV model seems to be inadequate to evaluate subjective thermal perception in Indians. These results can be used in feedback control of HVAC systems in residential and industrial buildings. (C) 2014 Elsevier B.V. All rights reserved.