985 resultados para 3D point
Resumo:
This is the weekly e-Newsletter called “The OCBI Tipping Point.” We hope that you find it very informative as we explore all possibilities to keep our constituency and the general public informed about all matters that affect Blacks in the state of Iowa.
Resumo:
This is the weekly e-Newsletter called “The OCBI Tipping Point.” We hope that you find it very informative as we explore all possibilities to keep our constituency and the general public informed about all matters that affect Blacks in the state of Iowa.
Resumo:
This is the weekly e-Newsletter called “The OCBI Tipping Point.” We hope that you find it very informative as we explore all possibilities to keep our constituency and the general public informed about all matters that affect Blacks in the state of Iowa.
Resumo:
This study aims to provide a passive sampling approach which can be routinely used to investigate polychlorinated biphenyl (PCB) sources in rivers. The approach consists of deploying low density polyethylene (LDPE) strips downstream and upstream of potential PCB sources as well as in their water discharges. Concentrations of indicator PCBs (iPCBs) absorbed in samplers (Cs) from upstream and downstream sites are compared with each other to reveal increases of PCB levels. Cs measured in water discharges are used to determine if released amounts of PCBs are compatible with increases revealed in the river. As water velocity can greatly vary along a river stretch and influences the uptake at each site in a different way, differences in velocity have to be taken into account to correctly interpret Cs. LDPE strips were exposed to velocities between 1.6 and 37 cm s−1 using a channel system built in the field. Relationships between velocity and Cs were established for each iPCB to determine the expected change in Cs due to velocity variations. For PCBs 28 and 52, this change does not exceed a factor 2 for velocity variations in the range from 1.6 to 100 cm s−1 (extrapolated data above 37 cm s−1). For PCBs 101, 138, 153 and 180, this change only exceeds a factor 2 in the case of large velocity variations. The approach was applied in the Swiss river Venoge to first conduct a primary investigation of potential PCB sources and then conduct thorough investigations of two suspected sources.
Resumo:
P130 A HIGH-RESOLUTION 2D/3D SEISMIC STUDY OF A THRUST FAULT ZONE IN LAKE GENEVA SWITZERLAND M. SCHEIDHAUER M. BERES D. DUPUY and F. MARILLIER Institute of Geophysics University of Lausanne 1015 Lausanne, Switzerland Summary A high-resolution three-dimensional (3D) seismic reflection survey has been conducted in Lake Geneva near the city of Lausanne Switzerland where the faulted molasse basement (Tertiary sandstones) is overlain by complex Quaternary sedimentary structures. Using a single 48-channel streamer an area of 1200 m x 600 m was surveyed in 10 days. With a 5-m shot spacing and a receiver spacing of 2.5 m in the inline direction and 7.5 m in the crossline direction, a 12-fold data coverage was achieved. A maximum penetration depth of ~150 m was achieved with a 15 cu. in. water gun operated at 140 bars. The multi-channel data allow the determination of an accurate velocity field for 3D processing, and they show particularly clean images of the fault zone and the overlying sediments in horizontal and vertical sections. In order to compare different sources, inline 55 was repeated with a 30/30 and a 15/15 cu. in. double-chamber air gun (Mini GI) operated at 100 and 80 bars, respectively. A maximum penetration depth of ~450 m was achieved with this source.
Resumo:
Computed Tomography (CT) represents the standard imaging modality for tumor volume delineation for radiotherapy treatment planning of retinoblastoma despite some inherent limitations. CT scan is very useful in providing information on physical density for dose calculation and morphological volumetric information but presents a low sensitivity in assessing the tumor viability. On the other hand, 3D ultrasound (US) allows a highly accurate definition of the tumor volume thanks to its high spatial resolution but it is not currently integrated in the treatment planning but used only for diagnosis and follow-up. Our ultimate goal is an automatic segmentation of gross tumor volume (GTV) in the 3D US, the segmentation of the organs at risk (OAR) in the CT and the registration of both modalities. In this paper, we present some preliminary results in this direction. We present 3D active contour-based segmentation of the eye ball and the lens in CT images; the presented approach incorporates the prior knowledge of the anatomy by using a 3D geometrical eye model. The automated segmentation results are validated by comparing with manual segmentations. Then, we present two approaches for the fusion of 3D CT and US images: (i) landmark-based transformation, and (ii) object-based transformation that makes use of eye ball contour information on CT and US images.
Resumo:
We review methods to estimate the average crystal (grain) size and the crystal (grain) size distribution in solid rocks. Average grain sizes often provide the base for stress estimates or rheological calculations requiring the quantification of grain sizes in a rock's microstructure. The primary data for grain size data are either 1D (i.e. line intercept methods), 2D (area analysis) or 3D (e.g., computed tomography, serial sectioning). These data have been used for different data treatments over the years, whereas several studies assume a certain probability function (e.g., logarithm, square root) to calculate statistical parameters as the mean, median, mode or the skewness of a crystal size distribution. The finally calculated average grain sizes have to be compatible between the different grain size estimation approaches in order to be properly applied, for example, in paleo-piezometers or grain size sensitive flow laws. Such compatibility is tested for different data treatments using one- and two-dimensional measurements. We propose an empirical conversion matrix for different datasets. These conversion factors provide the option to make different datasets compatible with each other, although the primary calculations were obtained in different ways. In order to present an average grain size, we propose to use the area-weighted and volume-weighted mean in the case of unimodal grain size distributions, respectively, for 2D and 3D measurements. The shape of the crystal size distribution is important for studies of nucleation and growth of minerals. The shape of the crystal size distribution of garnet populations is compared between different 2D and 3D measurements, which are serial sectioning and computed tomography. The comparison of different direct measured 3D data; stereological data and direct presented 20 data show the problems of the quality of the smallest grain sizes and the overestimation of small grain sizes in stereological tools, depending on the type of CSD. (C) 2011 Published by Elsevier Ltd.
Resumo:
Pd1-xInx thin films (0.4 < x < 0.56) were prepared by radio frequency sputtering from a multi-zone target. The properties of these Hume-Rothery alloys were studied by X-ray diffractometry, electron probe microanalysis and scanning tunneling microscopy. The diffraction spectra were analyzed to obtain the intensity ratio of the (100) superlattice line to the (200) normal line, together with the variations of the lattice constant. The results ape explained quantitatively by a model based on point defects, i.e. Pd vacancies in In-rich films and Pd antisite atoms in Pd-rich films. In-rich films grow preferentially in the [100] direction while Pd-rich films grow preferentially in the [110] direction. The grains in indium-rich sputtered films appear to be enclosed in an atomically thick, indium-rich layer. The role of texture and the influence of point defects on electrical resistivity is also reported. (C) 1996 Elsevier Science Limited.