857 resultados para unité sémiotique temporelle
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate the effect of cement shade, light-curing unit, and water storage on tensile bond strength (a) of a feldspathic ceramic resin bonded to dentin.Materials and Methods: The dentin surface of 40 molars was exposed and etched with 37% phosphoric acid, then an adhesive system was applied. Forty blocks of feldspathic ceramic (Vita VM7) were produced. The ceramic surface was etched with 10% hydrofluoric acid for 60 s, followed by the application of a silane agent and a dual-curing resin cement (Variolink II). Ceramic blocks were cemented to the treated dentin using either A3 or transparent (Tr) shade cement that was activated using either halogen or LED light for 40 s. All blocks were stored in 37 degrees C distilled water for 24 h before cutting to obtain non-trimmed bar-shaped specimens (adhesive area = 1 mm(2) +/- 0.1) for the microtensile bond strength test. The specimens were randomly grouped according to the storage time: no storage or stored for 150 days in 37 degrees C distilled water. Eight experimental groups were obtained (n = 30). The specimens were submitted to the tensile bond strength test using a universal testing machine at a crosshead speed of 1 mm/min. The data were statistically analyzed using ANOVA and Tukey's post-hoc tests (alpha = 0.05).Results: The mean bond strength values were significantly lower for the corresponding water stored groups, except for the specimens using A3 resin cement activated by halogen light. There was no significance difference in mean bond strength values among all groups after water storage.Conclusion: Water storage had a detrimental effect under most experimental conditions. For both cement shades investigated (Tr and A3) under the same storage condition, the light-curing units (QTH and LED) did not affect the mean microtensile bond strengths of resin-cemented ceramic to dentin.
Resumo:
In this work a detailed modeling of three-phase distribution transformers aimed at complementing well-known approaches is presented. Thus, incidence of angular displacement and tapping is taken into account in the proposed models, considering both actual values and per unit. The analysis is based on minimal data requirement: solely short-circuit admittance is needed since three-phase transformers are treated as non-magnetically-coupled single-phase transformers. In order to support the proposed methodology, results obtained through laboratory tests are presented.
Resumo:
A colonização de nasofaringe por Staphylococcus aureus, resistente à meticilina (Methicillin-resistant S.aureus - MRSA), é comum em pacientes criticamente doentes, mas seu significado prognóstico não é inteiramente conhecido. Realizou-se estudo de coorte retrospectivo com 122 pacientes de uma unidade de terapia intensiva que realizaram triagem semanal para colonização por MRSA. Os desfechos de interesse foram: mortalidade geral e mortalidade por infecção. Diversas variáveis de exposição (gravidade, procedimentos, intercorrências e colonização nasofaríngea por MRSA) foram analisadas em modelos univariados e multivariados. Fatores significativamente associados à mortalidade geral ou por infecção foram: APACHE II e doença pulmonar. A colonização por MRSA não foi preditora de mortalidade geral (OR=1,02; IC95%=0,35-3; p=0,97) ou por infecção (OR=0,96; IC95%=0,33-2,89; p=0,96). Os resultados sugerem que, na ausência de fatores de gravidade, a colonização por MRSA não caracteriza pior prognóstico.
Resumo:
Nasopharyngeal colonization with methicillin-resistant Staphylococcus aureus (MRSA) often precedes the development of nosocomial infections. In order to identify risk factors for MRSA colonization, we conducted a case-case-control study, enrolling 122 patients admitted to a medical-surgical intensive care unit (ICU). All patients had been screened for nasopharyngeal colonization with S. aureus upon admission and weekly thereafter. Two case-control studies were performed, using as cases patients who acquired colonization with MRSA and methicillin-susceptible S. aureus (MSSA), respectively. For both studies, patients in whom colonization was not detected during ICU stay were selected as control subjects. Several potential risk factors were assessed in univariate and multivariable (logistic regression) analysis. MRSA and MSSA were recovered from nasopharyngeal samples from 27 and 10 patients, respectively. Independent risk factors for MRSA colonization were: length-of-stay in the ICU (Odds Ratio [OR]=1.12, 95%Confidence Interval[CI]=1.06-1.19, p<0.001) and use of ciprofloxacin (OR=5.05, 95%CI=1.38-21.90, p=0.015). The use of levofloxacin had a protective effect (OR=0.08, 95%CI=0.01-0.55, p=0.01). Colonization with MSSA was positively associated with central nervous system disease (OR=7.45, 95%CI=1.33-41.74, p=0.02) and negatively associated with age (OR=0.94, 95%CI=0.90-0.99, p=0.01). In conclusion, our study suggests a role for both cross-transmission and selective pressure of antimicrobials in the spread of MRSA.
Resumo:
CONTEXTO: Embora cerca de 30% a 50% dos pacientes hospitalizados em unidades de terapia intensiva (UTI) recebam algum tipo de sedativo, existe escassez de informações sobre efeitos adversos desta prática, especialmente no Brasil. Estes efeitos podem ser significantes e o uso de sedativos é associado a elevação de infecção e mortalidade, mesmo sendo difícil avaliar o impacto clínico deste procedimento. OBJETIVO: Avaliar o impacto da sedação sobre incidência de complicações e mortalidade em doentes graves durante internação em unidade de terapia intensiva. TIPO DE ESTUDO: Estudo prospectivo. LOCAL: Unidade de Terapia Intensiva Cirúrgica da Universidade Federal de São Paulo (UNIFESP) - Escola Paulista de Medicina. PARTICIPANTES: Após excluídos pacientes que permaneceram menos de 24 horas ou sem exames indispensáveis para o cálculo do índice de gravidade (APACHE II), restaram 307 pacientes. Estes foram divididos em dois grupos: Grupo Sedado e Grupo Não Sedado. Constatada heterogeneidade com relação ao APACHE II, foram pareados 97 sedados e 97 não sedados com idênticos índices de gravidade. VARIÁVEIS ESTUDADAS: Impacto da sedação e das técnicas sobre a mortalidade, tempo de internação, além da incidência de escara de decúbito ou pressão, trombose venosa profunda e infecção. RESULTADOS: Não houve diferença na incidência de trombose venosa profunda, entre os grupos Sedado e Não Sedado, enquanto que escara de decúbito foi significativamente maior nos sedados (p = 0,03). Infecção foi detectada em 45,4% dos pacientes com sedação e em 21,6% dos pacientes sem sedação (p = 0,006). A mortalidade para os pacientes que não receberam qualquer tipo de sedativo foi de 20,6% e, para aqueles que foram sedados durante a internação, foi de 52,6% (p < 0,0001). CONCLUSÕES: Conclui-se que a sedação está associada a maior duração da internação, morbidade e mortalidade significativas. Apesar da intensidade das associações encontradas, não é possível estabelecer relação causal entre sedação e mortalidade.
Resumo:
Resumo:
Reaction of equimolar amounts of [Co-2(CO)(6)(dppm)] and [Cr(eta(6)-C6H5)(C=-CCH2NMe2)(CO)(3)] (1) in benzene gives the novel heterotrimetallic complex [Cr(eta(6)-C6H5){(mu(2)-eta(2)-C=CCH2NMe2)Co-2(CO)(4)(dppm)}(CO)(3)] (2) in 40% yield. The X-ray structure analysis of 2 reveals that the Cr(CO)(3) tripod adopts a nearly anti-eclipsed conformation. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
It can be observed that the number and the complexity of the application's domains, where the Paraconsistent Annotated Logic has been used, have grown a lot in the last decade. This increase in the complexity of the application's domain is an extra challenge for the designers of such systems, once there are not suitable computer hardware to run paraconsistent systems. This work proposes a new hardware architecture for the building Paraconsistent system.
Resumo:
Presented here is a study about the capability of a sensing unit to detect changes in river water quality. In order to determine its accuracy, water quality was monitored at 11 points along the Veado River in Presidente Prudente, Brazil. To have a basis for comparison, a water quality index (WQI) was developed following methods previously applied in different watersheds. Results showed an accurate relationship between WQI and electric impedance readings detected by the sensing unit. Principal components analysis (PCA) was used to derive results in a form that can be correlated with WQI calculated for each sample point, which showed the potential application of this device.