809 resultados para strain-compensation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recent trend in networked control systems (NCSs) is the use of wireless networks enabling interoperability between existing wired and wireless systems. One of the major challenges in these wireless NCSs (WNCSs) is to overcome the impact of the message loss that degrades the performance and stability of these systems. Moreover, this impact is greater when dealing with burst or successive message losses. This paper discusses and presents the experimental results of a compensation strategy to deal with this burst message loss problem in which a NCS mathematical model runs in parallel with the physical process, providing sensor virtual data in case of packet losses. Running in real-time inside the controller, the mathematical model is updated online with real control signals sent to the actuator, which provides better reliability for the estimated sensor feedback (virtual data) transmitted to the controller each time a message loss occurs. In order to verify the advantages of applying this model-based compensation strategy for burst message losses in WNCSs, the control performance of a motor control system using CAN and ZigBee networks is analyzed. Experimental results led to the conclusion that the developed compensation strategy provided robustness and could maintain the control performance of the WNCS against different message loss scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Lewis histo-blood group system is characterized by the expression of the Lea and Le(b) antigens in the gastrointestinal tract, whose synthesis results in interactions between alpha 2-L-fucosyltransferase (FUTII) and alpha 3/4-L-fucosyltransferase (FUTIII) enzymes coded by the FUT2 (19q. 13.3) and FUT3 (19p13.3) genes. FUTII and FUTIII fucosylate the type 1 oligosaccharide precursor (Gal beta 1 -> 3NAcGlc beta 1 -> 3-R) at distinct positions to form H type 1 (Fuc alpha 1. 2Gal beta 1. 3NAcGlc beta 1 -> 3-R) and Le(a) (Gal beta 1 -> 3[Fuc alpha 1 -> 4] NAcGlc beta 1 -> 3-R) antigens, respectively. The fucosylation of H type 1 antigens by FUTIII results in the Leb antigen (Fuc alpha 1. 2Gal beta 1. 3[Fuca1. 4] NAcGlc beta 1. 3-R). Thus, the presence of the FUTII and FUTIII enzymes leads to the expression of the Le(a+b+) phenotype, while the presence of only FUTIII allows the expression of the Le(a+b-) phenotype. The absence of the FUTIII enzyme leads to the expression of the Le(a-b-) phenotype, independent of the presence or absence of FUTII. Point mutations in FUT2 and FUT3 genes change the activity of these enzymes, impair the synthesis of Le(a) and Le(b) antigens, and contribute to the variability of Lewis phenotypes in the gastrointestinal tract. Toxoplasma gondii, an apicomplexan parasite that infects a large proportion of the world's population, utilizes the gastrointestinal tract as an infection route and seems to adhere to glycosylated molecules to invade human cells. These apparently independent events may be related. The aim of this study was to test the hypothesis that there is an association between the Lewis histo-blood group system and infection by T. gondii. Two hundred and nine serum samples collected from pregnant women were submitted to screening tests to detect anti-T. gondii antibodies, employing the indirect hemagglutination method. ELISA was utilized to identify IgG class anti-T. gondii antibodies specific for the RH strain. A hundred and ninety-five samples with concordant results for both methods were selected to form two groups: seropositive (G1) and seronegative (G2). The G428A mutation of the FUT2 gene, and T202C and C314T of the FUT3 gene, which allow inference of the gastrointestinal tract Lewis phenotypes, were identified using PCR-RFLP and PCR-SSP methods, respectively. Among the 195 samples selected, 116 (59.5%) were seropositive and 79 (40.5%) were seronegative. In G1, 68 (58.6%) were classified as Le(a+b+), 30 (25.9%) as Le(a+b-), and 18 (15.5%) as Le(a-b-), and in G2, 67 (84.8%) were classified as Le(a+b+), 12 (15.2%) as Le(a+b-), and 0 (0%) as Le(a-b-) (P < 0.0001). The Le(a-b-) phenotype is associated with a high risk of RH strain T. gondii infection when compared with the Le(a+b+) [P = 0.0001; OR = 36,460; 95%CI = 2.152-617,680] and Le(a+b-) phenotypes [P = 0.0118; OR = 15,165; 95%CI = 0.8463-271,710]. The Le(a+b-) phenotype showed a higher risk compared to the Le(a+b+) phenotype [P = 0.0206; OR = 2463; 95%CI = 2463-5214]. The results suggest that the Le(a-b-) phenotype is strongly associated with a greater risk of infection by the RH strain of T. gondii compared to the other phenotypes. It is possible that the absence of fucosylation of the type 1 oligosaccharide precursor as well as the variations in the structures of the Le(a) and Le(b) antigens influence susceptibility to infection by this parasite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invertases are enzymes which hydrolyze the sucrose and are widely employed in food and pharmaceutical industries. In this work, the screening of autochthonous grape yeasts from Brazil was carried out in order to investigate their invertase production potential. Yeasts belonging to Saccharomyces, Hanseniaspora, Sporidiobolus, Issatchenkia, Candida, Cryptococcus and Pichia genera were analyzed by submerged fermentation (SbmF) using sucrose as substrate. Among them, Candida stellata strain (N5 strain) was selected as the best producer (10.6 U/ml after 48 hours of SbmF). This invertase showed optimal activity at pH 3.0 and 55°C, demonstrating appropriate characters for application in several industrial processes, which includes high temperatures and acid pHs. In addition, this invertase extract presented tolerance to low concentrations of ethanol, suggesting that it could also be suitable for application at the beginning of alcoholic fermentation. These data provide promising prospects of the use of this new invertase in food and ethanol industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The probiotic potential of Leuconostoc mesenteroides subsp. mesenteroides SJRP55 isolated from water buffalo mozzarella cheese was evaluated. The microorganism presented resistance to stressful conditions that simulated the gastrointestinal tract, and to the best of our knowledge Leuconostoc mesenteroides SJRP55 was the first of this species with the ability to deconjugate bile salts. Tolerance to NaCl was temperature dependent, as well the results obtained by aggregation capacity. The strain presented good adhesion properties, β galactosidase activity, viability in fermented milk during storage, non-active against Streptococcus thermophilus and sensible to most of the tested antibiotics. Some analgesic medications inhibited the growth of the strain. Leuconostoc mesenteroides SJRP55 exhibited in vitro probiotic potential, and it can be better characterized through future in vivo tests. This bacterium presents higher functional properties compared to other studied strains, and therefore it is a potential candidate for the application as a probiotic strain, which could be used by industries in the manufacture of functional milk-based products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcific aortic valve disease (CAVD) is a chronic disorder characterized by an abnormal mineralization of the leaflets, which is accelerated in bicuspid aortic valve (BAV). It is suspected that mechanical strain may promote/enhance mineralization of the aortic valve. However, the effect of mechanical strain and the involved pathways during mineralization of the aortic valve remains largely unknown. Valve interstitial cells (VICs) were isolated and studied under strain conditions. Human bicuspid aortic valves were examined as a model relevant to increase mechanical strain. Cyclic strain increased mineralization of VICs by several-fold. Scanning electron microscope (SEM) and energy dispersive X-ray (EDX) analyses revealed that mechanical strain promoted the formation of mineralized spheroid microparticles, which coalesced into larger structure at the surface of apoptotic VICs. Apoptosis and mineralization were closely associated with expression of ENPP1. Inhibition of ENPP1 greatly reduced mineralization of VIC cultures. Through several lines of evidence we showed that mechanical strain promoted the export of ENPP1-containing vesicles to the plasma membrane through a RhoA/ROCK pathway. Studies conducted in human BAV revealed the presence of spheroid mineralized structures along with the expression of ENPP1 in areas of high mechanical strain. Mechanical strain promotes the production and accumulation of spheroid mineralized microparticles by VICs, which may represent one important underlying mechanism involved in aortic valve mineralization. RhoA/ROCK-mediated export of ENPP1 to the plasma membrane promotes strain-induced mineralization of VICs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces. Methods: A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N.mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed. Results: When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 mu m strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 mu m strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws. Conclusions: We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.