936 resultados para low intensity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Stress myocardial contrast echo (MCE) is technically challenging with exercise (Ex) because of cardiacmovementandshort duration ofhyperemia.Vasodilators solve these limitations, but are less potent for inducing abnormal wall motion (WM). We sought whether a combined dipyridamole (DI; 0.56 mg/kg i.v. 4 min) and Ex stress protocol would enable MCE to provide incremental benefit toWManalysis for detection of CAD. Methods. Standard echo images were followed by real time MCE at rest and following stress in 85 pts, 70 undergoing quantitative coronary angiography and 15 low risk pts.WMAfrom standard and LVopacification images, and then myocardial perfusion were assessed sequentially in a blinded fashion. A subgroup of 13 pts also underwent Ex alone, to assess the contribution of DI to quantitative myocardial flow reserve (MFR). Results. Significant (>50%) stenoses were present in 43 pts, involving 69 territories. Addition of MCE improved SE sensitivity for detection of CAD (91% versus 74%, P = 0.02) and better appreciation of disease extent (87% versus 65%territories, P=0.003), with a non-significant reduction in specificity. In 55 territories subtended by a significant stenosis, but with no resting WM abnormality, ability to identify ischemia was also significantly increased by MCE (82% versus 60%, P = 0.002). MFR was less with Ex alone than with DIEx stress (2.4 ± 1.6 versus 4.0 ± 1.9, P = 0.05), suggesting prolongation of hyperaemia with DI may be essential to the results. Conclusions. Dipyridamole-exercise MCE adds significant incremental benefit to standard SE, with improved diagnostic sensitivity and more accurate estimation of extent of CAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Significant facial emotion recognition (FER) deficits have been observed in participants exhibiting high levels of eating psychopathology. The current study aimed to determine if the pattern of FER deficits is influenced by intensity of facial emotion and to establish if eating psychopathology is associated with a specific pattern of emotion recognition errors that is independent of other psychopathological or personality factors. Eighty females, 40 high and 40 low scorers on the Eating Disorders Inventory (EDI) were presented with a series of faces, each featuring one of five emotional expressions at one of four intensities, and were asked to identify the emotion portrayed. Results revealed that, in comparison to Low EDI scorers, high scorers correctly recognised significantly fewer expressions, particularly of fear and anger. There was also a trend for this deficit to be more evident for subtle displays of emotion (50% intensity). Deficits in anger recognition were related specifically to scores on the body dissatisfaction subscale of the EDI. Error analyses revealed that, in comparison to Low EDI scorers, high scorers made significantly more and fear-as-anger errors. Also, a tendency to label anger expressions as sadness was related to body dissatisfaction. Current findings confirm FER deficits in subclinical eating psychopathology and extend these findings to subtle expressions of emotion. Furthermore, this is the first study to establish that these deficits are related to a specific pattern of recognition errors. Impaired FER could disrupt normal social functioning and might represent a risk factor for the development of more severe psychopathology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gamma oscillations have previously been linked to pain perception and it has been hypothesised that they may have a potential role in encoding pain intensity. Stimulus response experiments have reported an increase in activity in the primary somatosensory cortex (SI) with increasing stimulus intensity, but the specific role of oscillatory dynamics in this change in activation remains unclear. In this study, Magnetoencephalography (MEG) was used to investigate the changes in cortical oscillations during 4 different intensities of a train of electrical stimuli to the right index finger, ranging from low sensation to strong pain. In those participants showing changes in evoked oscillatory gamma in SI during stimulation, the strength of the gamma power was found to increase with increasing stimulus intensity at both pain and sub-pain thresholds. These results suggest that evoked gamma oscillations in SI are not specific to pain but may have a role in encoding somatosensory stimulus intensity. © 2013 Rossiter, Worthen, Witton, Hall and Furlong.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The issues involved in employing nonlinear optical loop mirrors (NOLMs) as intensity filters in picosecond soliton transmission were examined in detail. It was shown that inserting NOLMs into a periodically amplified transmission line allowed picosecond solitons to be transmitted under conditions considered infeasible until now. The loop mirrors gave dual function, removing low-power background dispersive waves through saturable absorption and applying a negative feedback mechanism to control the amplitude of the solitons. The stochastic characteristics of the pulses that were due to amplifier spontaneous-emission noise were investigated, and a number of new properties were determined. In addition, the mutual interaction between pulses was also significantly different from that observed for longer-duration solitons. The impact of Raman scattering in the computations was included and it was shown that soliton self-frequency shifts may be eliminated by appropriate bandwidth restrictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To establish the optimal flash settings for retinal vessel oxygen saturation parameters using dual-wavelength imaging in a multiethnic group. METHODS. Twelve healthy young subjects (mean age 32 years [SD 7]; three Mediterranean, two South Asian, and seven Caucasian individuals) underwent retinal vessel oxygen saturation measurements using dual-wavelength oximetry, noncontact tonometry, and manual sphygmomanometry. In order to evaluate the impact of flash intensity, we obtained three images (fundus camera angle 30°, ONH centered) per flash setting. Flash settings of the fundus camera were increased in steps of 2 (initial setting of 6 and the final of 22), which reflect logarithmic increasing intensities from 13.5 to 214 Watt seconds (Ws). RESULTS. Flash settings below 27 Ws were too low to obtain saturation measurements, whereas flash settings of more than 214 Ws resulted in overexposed images. Retinal arteriolar and venular oxygen saturation was comparable at flash settings of 27 to 76 Ws (arterioles' range: 85%-92%; venules' range: 45%-53%). Higher flash settings lead to increased saturation measurements in both retinal arterioles (up to 110%) and venules (up to 92%), with a more pronounced increase in venules. CONCLUSIONS. Flash intensity has a significant impact on retinal vessel oxygen saturation measurements using dual-wavelength retinal oximetry. High flash intensities lead to supranormal oxygen saturation measurements with a magnified effect in retinal venules compared with arteries. In addition to even retinal illumination, the correct flash setting is of paramount importance for clinical acquisition of images in retinal oximetry. We recommend flash settings between 27 to 76 Ws. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work bridges the gap between the remote interrogation of multiple optical sensors and the advantages of using inherently biocompatible low-cost polymer optical fiber (POF)-based photonic sensing. A novel hybrid sensor network combining both silica fiber Bragg gratings (FBG) and polymer FBGs (POFBG) is analyzed. The topology is compatible with WDM networks so multiple remote sensors can be addressed providing high scalability. A central monitoring unit with virtual data processing is implemented, which could be remotely located up to units of km away. The feasibility of the proposed solution for potential medical environments and biomedical applications is shown.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detailed theoretical and numerical investigations of the transmission performance of adaptively modulated optical orthogonal frequency division multiplexed (AMOOFDM) signals are undertaken, for the first time, in optical amplification and chromatic dispersion (CD) compensation free single mode fiber (SMF) intensity-modulated and directdetection (IMDD) systems using two cascaded semiconductor optical amplifiers in a counterpropagating configuration as an intensity modulator (TC-SOA-CC-IM). A theoretical model describing the characteristics of this configuration is developed. Extensive performance comparisons are also made between the TC-SOA-CC and the single SOA intensity modulators. It is shown that, the TC-SOA-CC reaches its strongly saturated region using a lower input optical power much faster than the single SOA resulting in significantly reduced effective carrier lifetime and thus wide TC-SOA-CC bandwidths. It is shown that at low input optical power, we can increase the signal line rate almost 115% which will be more than twice the transmission performance offered by single SOA. In addition, the TCSOA-CC-IM is capable of supporting signal line rates higher than corresponding to the SOA-IM by using 10dB lower input optical powers. For long transmission distance, the TC-SOA-CC-IM has much stronger CD compensation capability compared to the SOA-IM. In addition the use of TC-SOA-CC-IM is more effective regarding the capability to benefit from the CD compensation for shorter distances starting at 60km SMF, whilst for the SOA-IM starting at 90km. © 2014 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent theoretical investigations have demonstrated that the stability of mode-locked solutions of multiple frequency channels depends on the degree of inhomogeneity in gain saturation. In this article, these results are generalized to determine conditions on each of the system parameters necessary for both the stability and the existence of mode-locked pulse solutions for an arbitrary number of frequency channels. In particular, we find that the parameters governing saturable intensity discrimination and gain inhomogeneity in the laser cavity also determine the position of bifurcations of solution types. These bifurcations are completely characterized in terms of these parameters. In addition to influencing the stability of mode-locked solutions, we determine a balance between cubic gain and quintic loss, which is necessary for the existence of solutions as well. Furthermore, we determine the critical degree of inhomogeneous gain broadening required to support pulses in multiple-frequency channels. © 2010 The American Physical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hurricane is one of the most destructive and costly natural hazard to the built environment and its impact on low-rise buildings, particularity, is beyond acceptable. The major objective of this research was to perform a parametric evaluation of internal pressure (IP) for wind-resistant design of low-rise buildings and wind-driven natural ventilation applications. For this purpose, a multi-scale experimental, i.e. full-scale at Wall of Wind (WoW) and small-scale at Boundary Layer Wind Tunnel (BLWT), and a Computational Fluid Dynamics (CFD) approach was adopted. This provided new capability to assess wind pressures realistically on internal volumes ranging from small spaces formed between roof tiles and its deck to attic to room partitions. Effects of sudden breaching, existing dominant openings on building envelopes as well as compartmentalization of building interior on the IP were systematically investigated. Results of this research indicated: (i) for sudden breaching of dominant openings, the transient overshooting response was lower than the subsequent steady state peak IP and internal volume correction for low-wind-speed testing facilities was necessary. For example a building without volume correction experienced a response four times faster and exhibited 30–40% lower mean and peak IP; (ii) for existing openings, vent openings uniformly distributed along the roof alleviated, whereas one sided openings aggravated the IP; (iii) larger dominant openings exhibited a higher IP on the building envelope, and an off-center opening on the wall exhibited (30–40%) higher IP than center located openings; (iv) compartmentalization amplified the intensity of IP and; (v) significant underneath pressure was measured for field tiles, warranting its consideration during net pressure evaluations. The study aimed at wind driven natural ventilation indicated: (i) the IP due to cross ventilation was 1.5 to 2.5 times higher for Ainlet/Aoutlet>1 compared to cases where Ainlet/Aoutlet<1, this in effect reduced the mixing of air inside the building and hence the ventilation effectiveness; (ii) the presence of multi-room partitioning increased the pressure differential and consequently the air exchange rate. Overall good agreement was found between the observed large-scale, small-scale and CFD based IP responses. Comparisons with ASCE 7-10 consistently demonstrated that the code underestimated peak positive and suction IP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among the different possible amplification solutions offered by Raman scattering in optical fibers, ultra-long Raman lasers are particularly promising as they can provide quasi-losless second order amplification with reduced complexity, displaying excellent potential in the design of low-noise long-distance communication systems. Still, some of their advantages can be partially offset by the transfer of relative intensity noise from the pump sources and cavity-generated Stokes to the transmitted signal. In this paper we study the effect of ultra-long cavity design (length, pumping, grating reflectivity) on the transfer of RIN to the signal, demonstrating how the impact of noise can be greatly reduced by carefully choosing appropriate cavity parameters depending on the intended application of the system. © 2010 Copyright SPIE - The International Society for Optical Engineering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The unimodal approach of using pentazocine as post-cesarean section pain relief is inadequate, hence the need for a safer, easily available and more effective multimodal approach. AIM: To evaluate the effectiveness of rectal diclofenac combined with intramuscular pentazocine for postoperative pain following cesarean section. METHODS: In this double blind clinical trial, 130 pregnant women scheduled for cesarean section under spinal anesthesia were randomly assigned to two groups. Group A received 100mg diclofenac suppository and group B received placebo suppository immediately following surgery, 12 and 24h later. Both groups also received intramuscular pentazocine 30mg immediately following surgery and 6 hourly postoperatively in the first 24 h. Postoperative pain was assessed by visual analogue scale at end of surgery and 2, 12 and 24 h after surgery. Patient satisfaction scores were also assessed. RESULTS: One hundred and sixteen patients completed the study. Combining diclofenac and pentazocine had statistically significant reduction in pain intensity at 2, 12, and 24 hours postoperatively compared to pentazocine alone (p <0.05). No significant side effects were noted in both groups. The combined group also had significantly better patient satisfaction scores. CONCLUSION: The addition of diclofenac suppository to intramuscular pentazocine provides better pain relief after cesarean section and increased patient satisfaction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report results from the analysis of intact polar lipids (IPLs) in sediments from Ocean Drilling Program Sites 1257 and 1258. IPLs, constituting the cell membranes of living organisms, were detected in organic-lean sediments but not in underlying organic-rich black shales. Microbial activity in organic-lean sediments is likely due to sulfate-dependent oxidation of methane whereas difficulties detecting IPLs in black shales are interpreted to result from unfavorable signal-to-noise ratios due to low cell concentrations in combination with extremely high analytical noise created by uncharacterized organic matrix. IPLs found are consistent with a low-diversity community of archaea and bacteria. The concentrations of IPLs are more than one order of magnitude lower than those in Neogene deep subsurface sediments at the Peruvian margin, suggestive of significantly lower cell concentrations in Demerara Rise. This finding is consistent with inferred low rates of subsurface microbial activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

International audience