832 resultados para high-intensity femtosecond laser pulse
Resumo:
The inscription of low insertion loss and negligibly polarization dependent fiber Bragg gratings inscribed using a femtosecond laser system is reported. Insertion losses were <0.4dB/20mm and polarization wavelength shift of <5pm, with transmission changes <0.1dB. © 2010 Optical Society of America.
Resumo:
The V˙O2 slow component (V˙O2sc) that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre-fatigue condition) or rest for 33 min (control condition) according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-s maximal sprints at a fixed pedaling cadence of 90 rev·min−1. Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE) were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and V˙O2max determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue (P = 0.03), the V˙O2sc was not significantly different between the pre-fatigue (464 ± 301 mL·min−1) and the control (556 ± 223 mL·min−1) condition (P = 0.50). Blood lactate response was not significantly different between conditions (P = 0.48) but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition (P < 0.01) suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the V˙O2 kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the V˙O2sc is strongly associated with locomotor muscle fatigue.
Resumo:
It has been established that Wingate-based high-intensity training (HIT) consisting of 4 to 6 x 30-s all-out sprints interspersed with 4-min recovery is an effective training paradigm. Despite the increased utilisation of Wingate-based HIT to bring about training adaptations, the majority of previous studies have been conducted over a relatively short timeframe (2 to 6 weeks). However, activity during recovery period, intervention duration or sprint length have been overlooked. In study 1, the dose response of recovery intensity on performance during typical Wingate-based HIT (4 x 30-s cycle all-out sprints separated by 4-min recovery) was examined and active recovery (cycling at 20 to 40% of V̇O2peak) has been shown to improve sprint performance with successive sprints by 6 to 12% compared to passive recovery (remained still), while increasing aerobic contribution to sprint performance by ~15%. In the following study, 5 to 7% greater endurance performance adaptations were achieved with active recovery (40%V̇O2peak) following 2 weeks of Wingate-based HIT. In the final study, shorter sprint protocol (4 to 6 x 15-s sprints interspersed with 2 min of recovery) has been shown to be as effective as typical 30-s Wingate-based HIT in improving cardiorespiratory function and endurance performance over 9 weeks with the improvements in V̇O2peak being completed within 3 weeks, whereas exercise capacity (time to exhaustion) being increased throughout 9 weeks. In conclusion, the studies demonstrate that active recovery at 40% V̇O2peak significantly enhances endurance adaptations to HIT. Further, the duration of the sprint does not seem to be a driving factor in the magnitude of change with 15 sec sprints providing similar adaptations to 30 sec sprints. Taken together, this suggests that the arrangement of recovery mode should be considered to ensure maximal adaptation to HIT, and the practicality of the training would be enhanced via the reduction in sprint duration without diminishing overall training adaptations.
Resumo:
High intensity leg cycle ergometry is a widely used method of measuring muscular performance during maximal exercise. Until recently, it was deemed to be a predominantly lower body activity; however, there is now evidence to suggest that the upper body could be making a significant contribution to power output, as demonstrated by the intense electrical activity of the forearm musculature. As high intensity cycle ergometry often is used to measure performance in untrained cyclists it is important they are given at least two familiarisation trials to ensure results are both reliable and reproducible. In addition, diurnal variations exist during a single high intensity bout of exercise. It is likely these daily fluctuations are influenced by a number of biochemical and physiological variables. The purpose of this article is to outline factors that contribute to our interpretation of data following high intensity cycle ergometry.
Resumo:
We propose and demonstrate a switchable dual-wavelength erbium-doped fibre ring laser. Competition between the lasing wavelengths in erbium-doped fibre laser at room temperature is suppressed by incorporating a two-channel fibre Bragg grating (TC-FBG), which consists of two highly localized sub-gratings fabricated by femtosecond laser in single mode fibre. Wavelengths and polarization states of the lasing lines are selected by the TC-FBG. Laser output can be switched between single- and dual-wavelength operations by simply adjusting the polarization controller. Stable dual-wavelength output is verified at room temperature with a power fluctuation less than 0.27 dB, and wavelength fluctuation less than 0.004 nm.
Resumo:
The phenomenon post activation potentiation (PAP) can be defined as an increase in muscle performance following a heavy contraction of a movement that utilizes the same muscle group (i.e. improved 20m sprint following a high intensity squat). However, research has yet to examine if heavy squats elicit PAP on the squat itself. Further, past studies have not yet analyzed if PAP is elicited at a moderate intensity (i.e. 60% one-repetition maximum-1RM).
Resumo:
The purpose of this study was to quantify the metabolic equivalents (METs) of resistance exercise in obese patients with type 2 diabetes (T2DM) and healthy young subjects and to evaluate whether there were differences between sessions executed at low- versus high-intensity resistance exercise. Twenty obese patients with T2DM (62.9±6.1 years) and 22 young subjects (22.6±1.9 years) performed two training sessions: one at vigorous intensity (80% of 1-repetition maximum (1RM)) and one at moderate intensity (60% of 1RM). Both groups carried out three strength exercises with a 2-day recovery between sessions. Oxygen consumption was continuously measured 15 min before, during and after each training session. Obese T2DM patients showed lower METs values compared with young healthy participants at the baseline phase (F= 2043.86; P<0.01), during training (F=1140.59; P<0.01) and in the post-exercise phase (F=1012.71; P<0.01). No effects were detected in the group x intensity analysis of covariance. In this study, at both light-moderate and vigorous resistance exercise intensities, the METs value that best represented both sessions was 3 METs for the obese elderly T2DM patients and 5 METs for young subjects.
Resumo:
利用800nm抽运和400nm探针技术,测量了CaF2和MgO的时间分辨反射率,研究了材料的电子激发和弛豫超快动力学过程。采用耦合动力学模型,探讨了飞秒激光对透明介质材料的激发,以及材料的激发对抽运激光在材料中的传输、分布和反射特性的影响。根据这个理论模型计算了时间分辨反射率的演化,计算结果和实验结果相吻合。研究表明,多光子电离(MPI)和碰撞电离(II)在介质材料的导带电子激发中起着重要的作用。
Resumo:
通过数值求解三维电场传播方程,理论模拟了飞秒强激光脉冲(50fs,10^16w/cm^2)在氩气和中等尺寸氩团簇中的传播效应.结果表明,飞秒强激光脉冲经氩气传播将发生频谱蓝移展宽和光束发散;而经中等尺寸氩团簇传播,则存在一定程度的自聚焦效应.
Resumo:
Experimental investigation of Talbot self-imaging effect of an amplitude grating under illumination of femtosecond laser pulse -- the FemtoTalbot effect is reported. Theoretical analyzed results show that Talbot images under illumination of femtosecond laser pulses are not the same as that under continuous wave illumination. Experimental results are in good agreement with the theoretical analysis. We believe that the experimental investigation of the FemtoTalbot effect is highly interesting for the enormous potential applications of Talbot effect.
Resumo:
阐述了频率分辨光学开关法测量飞秒脉冲的原理,详细分析了模式尺寸效应和非线性效应对飞秒脉冲测量的影响。构建了一台用于飞秒脉冲测量的二次谐波-频率分辨光学开关装置,利用该装置对谐振腔输出的飞秒脉冲及压缩后的脉冲进行了测量。得到了飞秒脉冲的时间宽度及光谱宽度、电场及其相位在时域和频域的详细信息。谐振腔直接输出脉冲的时间宽度为56 fs,光谱宽度为27 nm,时间带宽积为0.686,算法中的最小误差为0.001792。脉冲压缩后的测量结果为27 fs,光谱宽度为92 nm,时间带宽积为1.27,算法误差为0.00
Resumo:
采用反射式达曼光栅对飞秒激光进行分束,可以避免材料色散的影响。搭建了利用反射式1×2达曼光栅为基础的频率分辨光学开关(FROG)装置,并把测量结果与传统多发频率分辨光学开关装置的测量结果进行了对比。理论和实验结果表明,当输入脉冲宽度大于50 fs时,用达曼光栅作为分光器和使用分光镜分光的效果是一样的;当输入脉冲的宽度小于50 fs时,用达曼光栅作为分光器引入的展宽量明显小于分光镜引入的展宽量,尤其是当输入脉冲的宽度小于20 fs时用达曼光栅作为分光器的效果更为突出。