874 resultados para fractures fixation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to estimate the hospitalization incidence and the total number of hospital days related to all fractures and osteoporotic fractures in the year 2000 in Switzerland and to compare these with data from other frequent disorders in men and women. The official administrative and medical statistics database of the Swiss Federal Office of Statistics (SFOS) from the year 2000 was used. It covered 81.2% of all registered patient admissions and was considered to be representative of the entire population. We included the ICD-10 codes of 84 diagnoses that were compatible with an underlying osteoporosis and applied the best matching age-specific osteoporosis attribution rates published for the ICD-9 diagnosis codes to the individual ICD-10 codes. To preserve comparability with previously published data from 1992, we grouped the data related to the ICD-10 fracture codes into seven diagnosis pools (fractures of the axial skeleton, fractures of the proximal upper limbs, fractures of the distal upper limbs, fractures of the proximal lower limbs, fractures of the distal lower limbs, multiple fractures, and osteoporosis) and analyzed them separately for women and men by age group. Incidences of hospitalization due to fractures were calculated, and the direct medical costs related to hospitalization were estimated. In addition, we compared the results with those from chronic pulmonary obstructive disease (COPD), stroke, acute myocardial infarction, heart failure, diabetes and breast carcinoma from the same database. In Switzerland during 2000, 62,535 hospitalizations for fractures (35,586 women and 26,949 men) were registered. Fifty-one percent of all fractures in women and 24% in men were considered as osteoporotic. The overall incidences of hospitalization due to fractures were 969 and 768 per 100,000 in women and men, respectively. The hospitalization incidences for fractures of the proximal lower limbs and the axial skeleton increased exponentially after the age of 65 years. The direct medical cost of hospitalization of patients with osteoporosis and/or related fractures was 357 million CHF. Hip fractures accounted for approximately half of these costs in women and men. Among other common diseases in women and men, osteoporosis ranked number 1 in women and number 2 (behind COPD) in men. When compared with data from 1992, the average length of stay had shortened by 8.4 days for women and 4.7 days for men, leading to a decrease of almost 40% in direct medical costs related to acute hospitalizations. This apparent decrease in cost might result from a shift into the ambulatory cost segment, for which the assessment and management tools need to be developed. We conclude that, in 2000, osteoporosis continued to be a heavy burden on the Swiss healthcare system. Lack of awareness of the disease and its consequences prevents widespread use of drugs with anti-fracture efficacy. This limits their potential to reduce costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone ultrasound measures (QUSs) can assess fracture risk in the elderly. We compared three QUSs and their association with nonvertebral fracture history in 7562 Swiss women 70-80 years of age. The association between nonvertebral fracture was higher for heel than phalangeal QUS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pedicle hooks which are used as an anchorage for posterior spinal instrumentation may be subjected to considerable three-dimensional forces. In order to achieve stronger attachment to the implantation site, hooks using screws for additional fixation have been developed. The failure loads and mechanisms of three such devices have been experimentally determined on human thoracic vertebrae: the Universal Spine System (USS) pedicle hook with one screw, a prototype pedicle hook with two screws and the Cotrel-Dubousset (CD) pedicle hook with screw. The USS hooks use 3.2-mm self-tapping fixation screws which pass into the pedicle, whereas the CD hook is stabilised with a 3-mm set screw pressing against the superior part of the facet joint. A clinically established 5-mm pedicle screw was tested for comparison. A matched pair experimental design was implemented to evaluate these implants in constrained (series I) and rotationally unconstrained (series II) posterior pull-out tests. In the constrained tests the pedicle screw was the strongest implant, with an average pull-out force of 1650 N (SD 623 N). The prototype hook was comparable, with an average failure load of 1530 N (SD 414 N). The average pull-out force of the USS hook with one screw was 910 N (SD 243 N), not significantly different to the CD hook's average failure load of 740 N (SD 189 N). The result of the unconstrained tests were similar, with the prototype hook being the strongest device (average 1617 N, SD 652 N). However, in this series the difference in failure load between the USS hook with one screw and the CD hook was significant. Average failure loads of 792 N (SD 184 N) for the USS hook and 464 N (SD 279 N) for the CD hook were measured. A pedicular fracture in the plane of the fixation screw was the most common failure mode for USS hooks.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this retrospective study was to compare patterns of vertebral fractures and luxations in 42 cats and 47 dogs, and to evaluate the impact of species-related differences on clinical outcome. Data regarding aetiology, neurological status, radiographic appearance and follow-up were compared between the groups. The thoracolumbar (Th3-L3) area was the most commonly affected location in both cats (49%) and dogs (58%). No lesions were observed in the cervical vertebral segments in cats, and none of the cats showed any signs of a Schiff-Sherrington syndrome. Vertebral luxations were significantly more frequent in dogs (20%) than in cats (6%), whereas combined fracture-luxations occurred significantly more often in cats (65%) than in dogs (37%). Caudal vertebral segment displacement was mostly dorsal in cats and ventral in dogs, with a significant difference in direction between cats and large dogs. The clinical outcome did not differ significantly between the two populations, and was poor in most cases (cats: 61%; dogs: 56%). The degree of dislocation and axis deviation were both significantly associated with a worse outcome in dogs, but not in cats. Although several differences in vertebral fractures and luxation patterns exist between cats and dogs, these generally do not seem to affect outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visual fixation is employed by humans and some animals to keep a specific 3D location at the center of the visual gaze. Inspired by this phenomenon in nature, this paper explores the idea to transfer this mechanism to the context of video stabilization for a handheld video camera. A novel approach is presented that stabilizes a video by fixating on automatically extracted 3D target points. This approach is different from existing automatic solutions that stabilize the video by smoothing. To determine the 3D target points, the recorded scene is analyzed with a stateof- the-art structure-from-motion algorithm, which estimates camera motion and reconstructs a 3D point cloud of the static scene objects. Special algorithms are presented that search either virtual or real 3D target points, which back-project close to the center of the image for as long a period of time as possible. The stabilization algorithm then transforms the original images of the sequence so that these 3D target points are kept exactly in the center of the image, which, in case of real 3D target points, produces a perfectly stable result at the image center. Furthermore, different methods of additional user interaction are investigated. It is shown that the stabilization process can easily be controlled and that it can be combined with state-of-theart tracking techniques in order to obtain a powerful image stabilization tool. The approach is evaluated on a variety of videos taken with a hand-held camera in natural scenes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minimally invasive vertebral augmentation-based techniques have been used for the treatment of spinal fractures (osteoporotic and malignant) for approximately 25 years. In this review, we try to give an overview of the current spectrum of percutaneous augmentation techniques, safety aspects and indications. Crucial factors for success are careful patient selection, proper technique and choice of the ideal cement augmentation option. Most compression fractures present a favourable natural course, with reduction of pain and regainment of mobility after a few days to several weeks, whereas other patients experience a progressive collapse and persisting pain. In this situation, percutaneous cement augmentation is an effective treatment option with regards to pain and disability reduction, improvement of quality of life and ambulatory and pulmonary function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe the most reliable insertion angle, corridor length and width to place a ventral transarticular atlantoaxial screw in miniature breed dogs. STUDY DESIGN: Retrospective CT imaging study. SAMPLE POPULATION: Cervical CT scans of toy breed dogs (n = 21). METHODS: Dogs were divided into 2 groups--group 1: no atlantoaxial abnormalities; group 2: atlantoaxial instability. Insertion angle in medial to lateral and ventral to dorsal direction was measured in group 1. Corridor length and width were measured in groups 1 and 2. Corridor width was measured at 3 points of the corridor. Each variable was measured 3 times and the mean used for statistical analysis. RESULTS: Mean +/- SD optimal transarticular atlantoaxial insertion angle was determined to be 40 +/- 1 degrees in medial to lateral direction from the midline and 20 +/- 1 degrees in ventral to dorsal direction from the floor of the neural canal of C2. Mean corridor length was 7 mm (range, 4.5-8.0 mm). Significant correlation was found between corridor length, body weight, and age. Mean bone corridor width ranged from 3 to 5 mm. Statistically significant differences were found between individuals, gender and measured side. CONCLUSIONS: Optimal placement of a transarticular screw for atlantoaxial joint stabilization is very demanding because the screw path corridor is very narrow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine C4-C7 cervical spines (n = 9). METHODS: Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while angular motion was measured. Range of motion (ROM) and neutral zone (NZ) were calculated for (1) intact specimens, (2) specimens after discectomy and fixation with a purpose-built intervertebral fusion cage with integrated ventral fixation, and (3) after removal of the device and fixation with a ventral locking plate. RESULTS: Both fixation techniques resulted in a decrease in ROM and NZ (P < .001) compared with the intact segments. There were no significant differences between the anchored spacer and locking plate fixation. CONCLUSION: An anchored spacer appears to provide similar biomechanical stability to that of locking plate fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To biomechanically test the properties of three different Universal Micro External Fixator (UMEX™) configurations with regard to their use in very small animals (<5kg) and compare the UMEX system to the widely used IMEX External Skeletal Fixation (SK™) system in terms of stiffness, space needed for pin placement and weight. METHODS Three different UMEX configurations (type Ia, type Ib, and type II modified) and one SK configuration type Ia were used to stabilize Delrin plastic rods in a 1 cm fracture gap model. These constructs were tested in axial compression, craniocaudal bending, mediolateral bending, and torsion. Testing was conducted within the elastic range and mean stiffness in each mode was determined from the slope of the linear portion of the load-deformation curve. A Kruskal Wallis one-way analysis of variance on ranks test was utilized to assess differences between constructs (p <0.05). RESULTS The UMEX type II modified configuration was significantly stiffer than the other UMEX configurations and the SK type Ia, except in craniocaudal bending, where the SK type Ia configuration was stiffer than all UMEX constructs. The UMEX type Ia configuration was significantly the weakest of those frames. The UMEX constructs were lighter and smaller than the SK, thus facilitating closer pin placement. CONCLUSIONS Results supported previous reports concerning the superiority of more complex constructs regarding stiffness. The UMEX system appears to be a valid alternative for the treatment of long-bone fractures in very small animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors tested an autoclavable external ring retractor, fixed to the operation table, for the endoscopic reconstruction of anterior column injuries of the thoracolumbar junction. It served as a retractor for the diaphragm, and offered a stable support for the scope and other instruments, making an assistant superfluous. Moreover, it allowed bimanual manipulation. Of course, the two-dimensional image, provided by the scope, necessitated proper eye-hand coordination. Twenty-eight consecutive patients underwent either a monosegmental (n = 10) or a bisegmental (n = 18) anterior stabilization in the area Th11L1. Three portals were necessary, but an assistant was not needed. The overall (mean +/- SD) operating time was 196 +/- 56 min, the blood loss was 804 +/- 719 mL. Intraoperatively, one epidural bleeding and a single screw cut-out occurred. All complications were managed endoscopically. Postoperatively, evacuation of a haemothorax (n = 1) was necessary. In all patients, wounds and fractures healed uneventfully. The combination of the endoscopic technique and the retractor system was feasible, successful, safe, and time efficient. Moreover, it allowed for anterior instrumentation of thoracolumbar fractures by a single surgeon. It became the standard approach in the authors' department.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the difference between a 5-day and a 1-day postoperative course of antibiotic on the incidence of infection after mandibular fractures involving the alveolus. Sixty-two patients with fractures of the mandible involving the dentoalveolar region were randomly assigned to 2 groups, both of which were given amoxicillin/clavulanic acid 1.2 g intravenously every 8 h from admission until 24 h postoperatively. The 5-day group were then given amoxicillin/clavulanic acid 625 mg orally every 8 h for another 4 days. The 1-day group was given an oral placebo at the same intervals. Follow-up appointments were 1, 2, 4, 6, 12 weeks and 6 months postoperatively. Development of an infection was the primary end point. Fifty-nine of the 62 patients completed this study. Six of the 30 patients in the 5-day group (20%) and 6 out of the 29 in the 1-day group (21%) developed local wound infections. Three of the 6 in the 1-day group developed purulent discharge and swelling. One patient in the 5-day group developed a rash on the trunk. There were no significant differences in the incidence of infection or side effects between the groups. In fractures of the mandible involving the alveolus, a 1-day postoperative course of antibiotic is as effective in preventing infective complications as a 5-day regimen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The goal of this study was to evaluate the influence of the duration of postoperative antibiotics (1 day vs. ≥ 5 days) on wound infections following surgical treatment of facial fractures. METHODS Three hundred thirty-nine patient case histories with a total of 498 fractures were reviewed retrospectively with regard to infections occurring within a 6-month period following surgical management. Patients were divided into two groups based on the duration of postoperative antibiotics administered. Group A consisted of 125 patients who had 1 day of postoperative antibiotics, whereas Group B consisted of 214 patients who had five or more days of postoperative antibiotics. Statistical analysis was conducted to assess for possible differences in the rate of postoperative infections. RESULTS Five patients in Group A (4%) and seven patients in Group B (3.27%) developed infections within the follow-up period. Of these 12 patients, seven had sustained multiple facial bone fractures. Eleven infections occurred in patients with mandibular fractures and one in a midfacial fracture. Statistical analysis using Fisher's exact test showed no significant difference (p = 0.77) in the incidence of infection between Groups A and B. CONCLUSION In this retrospective study, the use of prolonged postoperative antibiotics in uncomplicated mandibular and midfacial fractures had no significant benefit in reducing the incidence of infections. LEVEL OF EVIDENCE Therapeutic study, level IV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.