868 resultados para fast scan voltammetric determinations
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The electrochemical oxidation of 3,4-dihydroxycinnamic acid, caffeic acid, leads to a stable electroactive poly(caffeic acid) thin film containing quinone moiety on a preactivated glassy polymeric carbon electrode. The properties of the deposited films as well as the stability study under different experimental conditions were investigated. Taking advantage of the electrochemical behavior, an analytical method based on differential pulse voltammetry for determination of caffeic acid in red wine was proposed.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O macaco-prego, Cebus apella, é muito difundido no norte e sul da Amazônia Legal Brasileira e no Cerrado. Estes animais encontram-se rotineiramente submetidos à caça predatória, aumentando assim a necessidade de preservação desta espécie silvestre. Realizou-se um estudo ultra-sonográfico de 10 macacos-prego como forma de descrever a anatomia ultra-sonográfica normal de sua cavidade abdominal. A vesícula urinária apresentou parede com espessura média 0,2cm e em posição anatômica cuja topografia permitiu contato com as paredes do corpo do útero e cólon descendente. À varredura abdominal caudal foi visualizada a aorta, veia cava caudal e veia ilíaca direita. O fígado foi visto em varredura sagital e transversal, possibilitando a observação da vesícula biliar e vasos hepáticos. A varredura renal demonstrou com precisão a pelve, seio renal e relação cortico-medular. O comprimento médio de ambos os rins foi de 6,24±0,31cm, não existindo diferença estatística entre o rim direito e esquerdo (Teste t de Student e ANOVA). O volume renal foi 2,37±0,18cm³. Os coeficientes de Correlação de Pearson entre os comprimentos renais direito e esquerdo e entre volumes renais direito e esquerdo foram dispostos como r = 0,74 e 0,51. As espessuras médias para a região cortical e medular foram 0,75±0,11cm e 0,39±0,06cm, respectivamente. O coeficiente de correlação para a relação cortico-medular entre os rins direito e esquerdo foi de r = 0,19. O exame ultrasonográfico mostrou-se como uma técnica eficiente, nãoinvasiva, rápida e reprodutível, que provê dados importantes aos profissionais da área de clínica e cirurgia de animais silvestres.
Resumo:
A gestão colaborativa é, atualmente, um elemento-chave no contexto da gestão da cadeia de suprimentos. Neste artigo, o tema é abordado mediante a análise de um caso real, em que uma grande rede mundial de fast-food e seu prestador de serviço logístico (PSL) trabalharam conjuntamente no Brasil em um projeto-piloto para a implementação de um collaborative planning, forecasting, and replenishment (CPFR). O trabalho faz uso de uma metodologia de pesquisa-ação e apresenta as principais variáveis que influenciaram o projeto, abordando os processos necessários para a implementação e os pontos que favorecem o CPFR. Com base no caso estudado, o trabalho apresenta um conjunto de propostas sobre o papel dos agentes da cadeia em projetos dessa natureza. A gestão da cadeia de suprimentos por intermédio da coordenação direta de um PSL também permite demonstrar as possibilidades e dificuldades desse sistema, contribuindo com a visão colaborativa na cadeia de suprimentos a partir da relação entre seus agentes.
Resumo:
Objetivou-se avaliar os efeitos dos aditivos própolis verde, própolis marrom e monensina sódica sobre as características de carcaça, avaliadas por ultra-som e pós-abate, os componentes corporais e o rendimento de cortes de cordeiros terminados em confinamento. Foram utilizados 32 cordeiros machos, com oito animais por tratamento, mantidos em confinamento por 64 dias. Os animais receberam dieta com relação volumoso:concentrado de 50:50, à base de feno de capim-tifton 85 (Cynodon spp.) e concentrado comercial. O delineamento experimental foi o de blocos ao acaso, com oito animais por dieta, distribuídos aleatoriamente de acordo com o peso: controle, dieta sem aditivo, própolis verde, própolis marrom e monensina sódica. Os rendimentos de carcaça (verdadeiro, quente e comercial) não diferiram entre os aditivos, com médias de 54,97; 44,89 e 41,81%, respectivamente. Os componentes corporais e rendimento de cortes comerciais não foram influenciados pelos aditivos utilizados nas dietas. A metodologia utilizada na determinação teve efeito nas medidas de área de olho-de-lombo (AOL) e espessura de gordura subcutânea (EGS), de modo que, pelo método tradicional, com medidas na carcaça, foram obtidas as maiores médias para AOL (12,14 vs. 9,08 cm²) e as menores para EGS (2,42 vs. 2,69 mm). A correlação entre as medidas de área de olho-de-lombo (AOL) da carcaça e aquelas obtidas por ultra-sonografia foi de 0,8597. Os aditivos não influenciaram as características de carcaça, os componentes corporais e o rendimento de cortes de ovinos terminados em confinamento. A realização de medidas ultra-sonográficas de AOL e marmoreio pode ser utilizada na avaliação de carcaça in vivo em ovinos.
Resumo:
A method was developed for the differential-pulse cathodic stripping voltammetric determination of ceftazidime with a hanging mercury drop electrode using its reduction peak at -0.43 V in Britton-Robinson buffer pH 4.0. The optimum accumulation potential and time were -0.15 V and up to 60 s, respectively. Linear calibration graphs were obtained from 1 x 10(-8) M and 1.5 x 10(-7) M. The limit of determination was calculated to be 5 x 10(-9) M. The coefficient of variation was 4% (n = 7) at 1 x 10(-7) M ceftazidime. The effect of various components of urine on the voltammetric response was studied, and creatinine, uric acid, urea, and glucose were shown to interfere in the method. Ceftazidime bound to human albumin gives a unique stripping peak at -0.48 V. Recoveries of 87% +/- 2% of the ceftazidime (n = 5) were obtained from urine spiked with 1.27 mu g ml(-1) using C-18 solid phase extraction cartridges. (C) 1997 Academic Press.
Resumo:
Procion red HE-3B (RR120) is an example of dye currently used in affinity purification. A method is described for determining trace amounts of RR120 dye contaminant in human serum albumin by cathodic stripping voltammetry. The method is based on a measure of a well-defined peak at -0.58 V, obtained when samples of HSA protein (0.01-2% w/v) containing dye concentrations are submitted to a heating time of 330 min at 80degreesC in NaOH, pH 12.0 and the samples are removed to a solution containing Britton-Robinson buffer, pH 4.0. Using an optimum accumulation potential and tune of 0 V and 240 s, respectively, linear calibration curves were obtained from 1.0 X 10(-9) to 1.0 X 10(-8) mol 1(-1) for RR120 dye. Leakage/hydrolysis of reactive red 120 from an agarose support (e.g. at pH 2 or 12) can also be conveniently determined at very low levels (sub-mug ml(-1)) by means of cathodic stripping voltammetry, which involves adsorptive accumulation of the dye onto the hanging mercury-drop electrode. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
At accumulation potentials close to +0.1 V at a hanging mercury drop electrode, ceftazidime is accumulated at pH 9.5, probably in a hydrolysed or otherwise chemically altered form, in an anodic process to give an adsorbed mercury salt. The accumulation of this mercury salt allows the indirect cathodic-stripping voltammetric determination of ceftazidime using the reduction peak of the mercury salt at -0.70 V. The high sensitivity of the method coupled with high sample dilution allows ceftazidime to be determined in milk samples at the 28 mu g ml(-1) level without prior separation. In order to determine lower levels of ceftazidime in milk (ca. 10 ng ml(-1)) a separation process would be required. (C) 1998 Elsevier B.V. B.V. All rights reserved.
Resumo:
Ceftazidime is hydrolysed only slowly at pH 10 at room temperature. This is indicated by a small cathodic stripping voltammetric peak obtained at pH 10 at a hanging mercury drop electrode at about -0.6 V which corresponds to the reduction of the hydrolysis product. This peak is enhanced more than tenfold by the addition of poly-L-lysine (PLL) to the electrolyte solution. The optimum accumulation potential is between 0 and -0.1 V: the size of the peak decreases steadily, however, as the accumulation potential is moved to more negative potentials and is about one-sixth the size for accumulation at -0.4 V. Existing knowledge of the organic chemistry of cephalosporins indicates that the accumulation must involve an aminolysis reaction of the unprotonated PLL with the beta-lactam ring of the ceftazidime. The limit of detection (3 sigma) in standard solutions was calculated to be 1 x 10(-10) mol l(-1). The detection limit in buffer solution containing 1% of urine was calculated to be 5 x 10(-9) mol l(-1), i.e. 5 x 10(-6) mol l(-1) in the urine. (C) 1999 Elsevier B.V. B.V. AU rights reserved.
Resumo:
A new, versatile, and simple method for quantitative analysis of zinc, copper, lead, and cadmium in fuel ethanol by anodic stripping voltammetry is described. These metals can be quantified by direct dissolution of fuel ethanol in water and subsequent voltammetric measurement after the accumulation step. A maximum limit of 20% (v/v) ethanol in water solution was obtained for voltammetric measurements without loss of sensitivity for metal species. Chemical and operational optimum conditions were analyzed in this study; the values obtained were pH 2.9, a 4.7-mum thickness mercury film, a 1,000-rpm rotation frequency of the working electrode, and a 600-s pre-concentration time. Voltammetric measurements were obtained using linear scan (LSV), differential pulse (DPV), and square wave (SWV) modes and detection limits were in the range 10(-9)-10(-8) mol L-1 for these metal species. The proposed method was compared with a traditional analytical technique, flame atomic absorption spectrometry (FAAS), for quantification of these metal species in commercial fuel ethanol samples.