840 resultados para external beam radiotherapy
Resumo:
BACKGROUND: To compare the prognostic value of different anatomical and functional metabolic parameters determined using [(18)F]FDG-PET/CT with other clinical and pathological prognostic parameters in cervical cancer (CC). METHODS: Thirty-eight patients treated with standard curative doses of chemo-radiotherapy (CRT) underwent pre- and post-therapy [(18)F]FDG-PET/CT. [(18)F]FDG-PET/CT parameters including mean tumor standardized uptake values (SUV), metabolic tumor volume (MTV) and tumor glycolytic volume (TGV) were measured before the start of CRT. The post-treatment tumor metabolic response was evaluated. These parameters were compared to other clinical prognostic factors. Survival curves were estimated by using the Kaplan-Meier method. Cox regression analysis was performed to determine the independent contribution of each prognostic factor. RESULTS: After 37 months of median follow-up (range, 12-106), overall survival (OS) was 71 % [95 % confidence interval (CI), 54-88], disease-free survival (DFS) 61 % [95 % CI, 44-78] and loco-regional control (LRC) 76 % [95 % CI, 62-90]. In univariate analyses the [(18)F]FDG-PET/CT parameters unfavorably influencing OS, DFS and LRC were pre-treatment TGV-cutoff ≥562 (37 vs. 76 %, p = 0.01; 33 vs. 70 %, p = 0.002; and 55 vs. 83 %, p = 0.005, respectively), mean pre-treatment tumor SUV cutoff ≥5 (57 vs. 86 %, p = 0.03; 36 vs. 88 %, p = 0.004; 65 vs. 88 %, p = 0.04, respectively) and a partial tumor metabolic response after treatment (9 vs. 29 %, p = 0.0008; 0 vs. 83 %, p < 0.0001; 22 vs. 96 %, p < 0.0001, respectively). After multivariate analyses a partial tumor metabolic response after treatment remained as an independent prognostic factor unfavorably influencing DFS and LRC (RR 1:7.7, p < 0.0001, and RR 1:22.6, p = 0.0003, respectively) while the pre-treatment TGV-cutoff ≥562 negatively influenced OS and DFS (RR 1:2, p = 0.03, and RR 1:2.75, p = 0.05). CONCLUSIONS: Parameters capturing the pre-treatment glycolytic volume and metabolic activity of [(18)F]FDG-positive disease provide important prognostic information in patients with CC treated with CRT. The post-therapy [(18)F]FDG-PET/CT uptake (partial tumor metabolic response) is predictive of disease outcome.
Resumo:
Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037). A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.
Resumo:
Abstract Objective: To determine whether low-level laser therapy can prevent salivary hypofunction after radiotherapy and chemotherapy in head and neck cancer patients. Materials and Methods: We evaluated 23 head and neck cancer patients, of whom 13 received laser therapy and 10 received clinical care only. An InGaAlP laser was used intra-orally (at 660 nm and 40 mW) at a mean dose of 10.0 J/cm2 and extra-orally (at 780 nm and 15 mW) at a mean dose of 3.7 J/cm2, three times per week, on alternate days. Stimulated and unstimulated sialometry tests were performed before the first radiotherapy and chemotherapy sessions (N0) and at 30 days after the end of treatment (N30). Results: At N30, the mean salivary flow rates were significantly higher among the laser therapy patients than among the patients who received clinical care only, in the stimulated and unstimulated sialometry tests (p = 0.0131 and p = 0.0143, respectively). Conclusion: Low-level laser therapy, administered concomitantly with radiotherapy and chemotherapy, appears to mitigate treatment-induced salivary hypofunction in patients with head and neck cancer.
Resumo:
Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.
Resumo:
Due to source contamination and wearing of instrument components problems caused by the direct insertion probe technique, a new way of introduction of low volatile compounds into mass spectrometer was tested. This new scheme comprises the introduction of the low volatile compounds solutions via a six port valve connected to a particle beam interface. Solutions of isatin were injected into this system and the best results were obtained with CH2Cl2, CH3OH and CH3CN. The solution inlet system has shown to be advantageous over the conventional way of direct insertion probe introduction.
Resumo:
Background and purpose: In planning to meet evidence based needs for radiotherapy, guidelines for the provision of capital and human resources are central if access, quality and safety are not to be compromised. A component of the ESTRO-HERO (Health Economics in Radiation Oncology) project is to document the current availability and content of guidelines for radiotherapy in Europe. Materials and methods: An 84 part questionnaire was distributed to the European countries through their national scientific and professional radiotherapy societies with 30 items relating to the availability of guidelines for equipment and staffing and selected operational issues. Twenty-nine countries provided full or partial evaluable responses. Results: The availability of guidelines across Europe is far from uniform. The metrics used for capital and human resources are variable. There seem to have been no major changes in the availability or specifics of guidelines over the ten-year period since the QUARTS study with the exception of the recent expansion of RTT staffing models. Where comparison is possible it appears that staffing for radiation oncologists, medical physicists and particularly RTTs tend to exceed guidelines suggesting developments in clinical radiotherapy are moving faster than guideline updating. Conclusion: The efficient provision of safe, high quality radiotherapy services would benefit from the availability of well-structured guidelines for capital and human resources, based on agreed upon metrics, which could be linked to detailed estimates of need
Resumo:
Background: Documenting the distribution of radiotherapy departments and the availability of radiotherapy equipment in the European countries is an important part of HERO the ESTRO Health Economics in Radiation Oncology project. HERO has the overall aim to develop a knowledge base of the provision of radiotherapy in Europe and build a model for health economic evaluation of radiation treatments at the European level. The aim of the current report is to describe the distribution of radiotherapy equipment in European countries. Methods: An 84-item questionnaire was sent out to European countries, principally through their national societies. The current report includes a detailed analysis of radiotherapy departments and equipment (questionnaire items 2629), analyzed in relation to the annual number of treatment courses and the socio-economic status of the countries. The analysis is based on validated responses from 28 of the 40 European countries defined by the European Cancer Observatory (ECO). Results: A large variation between countries was found for most parameters studied. There were 2192 linear accelerators, 96 dedicated stereotactic machines, and 77 cobalt machines reported in the 27 countries where this information was available. A total of 12 countries had at least one cobalt machine in use. There was a median of 0.5 simulator per MV unit (range 0.31.5) and 1.4 (range 0.44.4) simulators per department. Of the 874 simulators, a total of 654 (75%) were capable of 3D imaging (CT-scanner or CBCToption). The number of MV machines (cobalt, linear accelerators, and dedicated stereotactic machines) per million inhabitants ranged from 1.4 to 9.5 (median 5.3) and the average number of MV machines per department from 0.9 to 8.2 (median 2.6). The average number of treatment courses per year per MV machine varied from 262 to 1061 (median 419). While 69% of MV units were capable of IMRT only 49% were equipped for image guidance (IGRT). There was a clear relation between socio-economic status, as measured by GNI per capita, and availability of radiotherapy equipment in the countries. In many low income countries in Southern and Central-Eastern Europe there was very limited access to radiotherapy and especially to equipment for IMRT or IGRT. Conclusions: The European average number of MV machines per million inhabitants and per department is now better in line with QUARTS recommendations from 2005, but the survey also showed a significant heterogeneity in the access to modern radiotherapy equipment in Europe. High income countries especially in Northern-Western Europe are well-served with radiotherapy resources, other countries are facing important shortages of both equipment in general and especially machines capable of delivering high precision conformal treatments (IMRT, IGRT)
Resumo:
Background: The ESTRO Health Economics in Radiation Oncology (HERO) project has the overall aim to develop a knowledge base of the provision of radiotherapy in Europe and build a model for health economic evaluation of radiation treatments at the European level. The first milestone was to assess the availability of radiotherapy resources within Europe. This paper presents the personnel data collected in the ESTRO HERO database. Materials and methods: An 84-item questionnaire was sent out to European countries, through their national scientific and professional radiotherapy societies. The current report includes a detailed analysis of radiotherapy staffing (questionnaire items 4760), analysed in relation to the annual number of treatment courses and the socio-economic status of the countries. The analysis was conducted between February and July 2014, and is based on validated responses from 24 of the 40 European countries defined by the European Cancer Observatory (ECO). Results: A large variation between countries was found for most parameters studied. Averages and ranges for personnel numbers per million inhabitants are 12.8 (2.530.9) for radiation oncologists, 7.6 (019.7) for medical physicists, 3.5 (012.6) for dosimetrists, 26.6 (1.978) for RTTs and 14.8 (0.461.0) for radiotherapy nurses. The combined average for physicists and dosimetrists is 9.8 per million inhabitants and 36.9 for RTT and nurses. Radiation oncologists on average treat 208.9 courses per year (range: 99.9348.8), physicists and dosimetrists conjointly treat 303.3 courses (range: 85757.7) and RTT and nurses 76.8 (range: 25.7156.8). In countries with higher GNI per capita, all personnel categories treat fewer courses per annum than in less affluent countries. This relationship is most evident for RTTs and nurses. Different clusters of countries can be distinguished on the basis of available personnel resources and socio-economic status. Conclusions: The average personnel figures in Europe are now consistent with, or even more favourable than the QUARTS recommendations, probably reflecting a combination of better availability as such, in parallel with the current use of more complex treatments than a decade ago. A considerable variation in available personnel and delivered courses per year however persists among the highest and lowest staffing levels. This not only reflects the variation in cancer incidence and socio-economic determinants, but also the stage in technology adoption along with treatment complexity and the different professional roles and responsibilities within each country. Our data underpin the need for accurate prediction models and long-term education and training programmes
Resumo:
In this paper we model the multicointegration relation, allowing for one structural break. Since multicointegration is a particular case of polynomial or I(2) cointegration, our proposal can also be applied in these cases. The paper proposes the use of a residualbased Dickey-Fuller class of statistic that accounts for one known or unknown structural break. Finite sample performance of the proposed statistic is investigated by using Monte Carlo simulations, which reveals that the statistic shows good properties in terms of empirical size and power. We complete the study with an empirical application of the sustainability of the US external deficit. Contrary to existing evidence, the consideration of one structural break leads to conclude in favour of the sustainability of the US external deficit.
Resumo:
Quickremovalofbiosolidsinaquaculturefacilities,andspeciallyinrecirculatingaquaculturesystems(RAS),isoneofthemostimportantstepinwastemanagement.Sedimentationdynamicsofbiosolidsinanaquaculturetankwilldeterminetheiraccumulationatthebottomofthetank.
Resumo:
The focus of this dissertation is to develop finite elements based on the absolute nodal coordinate formulation. The absolute nodal coordinate formulation is a nonlinear finite element formulation, which is introduced for special requirements in the field of flexible multibody dynamics. In this formulation, a special definition for the rotation of elements is employed to ensure the formulation will not suffer from singularities due to large rotations. The absolute nodal coordinate formulation can be used for analyzing the dynamics of beam, plate and shell type structures. The improvements of the formulation are mainly concentrated towards the description of transverse shear deformation. Additionally, the formulation is verified by using conventional iso-parametric solid finite element and geometrically exact beam theory. Previous claims about especially high eigenfrequencies are studied by introducing beam elements based on the absolute nodal coordinate formulation in the framework of the large rotation vector approach. Additionally, the same high eigenfrequency problem is studied by using constraints for transverse deformation. It was determined that the improvements for shear deformation in the transverse direction lead to clear improvements in computational efficiency. This was especially true when comparative stress must be defined, for example when using elasto-plastic material. Furthermore, the developed plate element can be used to avoid certain numerical problems, such as shear and curvature lockings. In addition, it was shown that when compared to conventional solid elements, or elements based on nonlinear beam theory, elements based on the absolute nodal coordinate formulation do not lead to an especially stiff system for the equations of motion.
Resumo:
The main objective of this thesis is to show that plate strips subjected to transverse line loads can be analysed by using the beam on elastic foundation (BEF) approach. It is shown that the elastic behaviour of both the centre line section of a semi infinite plate supported along two edges, and the free edge of a cantilever plate strip can be accurately predicted by calculations based on the two parameter BEF theory. The transverse bending stiffness of the plate strip forms the foundation. The foundation modulus is shown, mathematically and physically, to be the zero order term of the fourth order differential equation governing the behaviour of BEF, whereas the torsion rigidity of the plate acts like pre tension in the second order term. Direct equivalence is obtained for harmonic line loading by comparing the differential equations of Levy's method (a simply supported plate) with the BEF method. By equating the second and zero order terms of the semi infinite BEF model for each harmonic component, two parameters are obtained for a simply supported plate of width B: the characteristic length, 1/ λ, and the normalized sum, n, being the effect of axial loading and stiffening resulting from the torsion stiffness, nlin. This procedure gives the following result for the first mode when a uniaxial stress field was assumed (ν = 0): 1/λ = √2B/π and nlin = 1. For constant line loading, which is the superimposition of harmonic components, slightly differing foundation parameters are obtained when the maximum deflection and bending moment values of the theoretical plate, with v = 0, and BEF analysis solutions are equated: 1 /λ= 1.47B/π and nlin. = 0.59 for a simply supported plate; and 1/λ = 0.99B/π and nlin = 0.25 for a fixed plate. The BEF parameters of the plate strip with a free edge are determined based solely on finite element analysis (FEA) results: 1/λ = 1.29B/π and nlin. = 0.65, where B is the double width of the cantilever plate strip. The stress biaxial, v > 0, is shown not to affect the values of the BEF parameters significantly the result of the geometric nonlinearity caused by in plane, axial and biaxial loading is studied theoretically by comparing the differential equations of Levy's method with the BEF approach. The BEF model is generalised to take into account the elastic rotation stiffness of the longitudinal edges. Finally, formulae are presented that take into account the effect of Poisson's ratio, and geometric non linearity, on bending behaviour resulting from axial and transverse inplane loading. It is also shown that the BEF parameters of the semi infinite model are valid for linear elastic analysis of a plate strip of finite length. The BEF model was verified by applying it to the analysis of bending stresses caused by misalignments in a laboratory test panel. In summary, it can be concluded that the advantages of the BEF theory are that it is a simple tool, and that it is accurate enough for specific stress analysis of semi infinite and finite plate bending problems.
Resumo:
Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.