898 resultados para esophagus stenosis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Applications of diffusion-weighted (DW) magnetic resonance (MR) imaging outside the brain have gained increasing importance in recent years. Owing to technical improvements in MR imaging units and faster sequences, the need for noninvasive imaging without contrast medium administration, mainly in patients with renal insufficiency, can be met successfully by applying this technique. DW MR imaging is quantified by the apparent diffusion coefficient (ADC), which provides information on diffusion and perfusion simultaneously. By using a biexponential fitting process of the DW MR imaging data, these two entities can be separated, because this type of fitting process can serve as an estimate of both the perfusion fraction and the true diffusion coefficient. DW MR imaging can be applied for functional evaluation of the kidneys in patients with acute or chronic renal failure. Impairment of renal function is accompanied by a decreased ADC. Acute ureteral obstruction leads to perfusion and diffusion changes in the affected kidney, and renal artery stenosis results in a decreased ADC. In patients with pyelonephritis, diffuse or focal changes in signal intensity are seen on the high-b-value images, with increased signal intensity corresponding to low signal intensity on the ADC map. The feasibility and reproducibility of DW MR imaging in patients with transplanted kidneys have already been demonstrated, and initial results seem to be promising for the assessment of allograft deterioration. Overall, performance of renal DW MR imaging, presuming that measurements are of high quality, will further boost this modality, particularly for early detection of diffuse renal conditions, as well as more accurate characterization of focal renal lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to review the results and clinical outcome of patients with surgically treated lesions within the trigone of the lateral ventricle. This is a retrospective case series of 20 (eight male, 12 female) patients with lesions of the trigone of the lateral ventricle operated between 1998 and 2008. All lesions were removed via the transcortical temporal and transcortical parietal route. Surgical complications and outcome were assessed using the modified Rankin Scale (mRS). There were four children and 16 adults with a mean age of 42?±?22 years (min?=?1, max?=?74). Eight (40%) lesions grew within the trigone of the dominant hemisphere. In 17 cases, the lesion was purely intraventricular, and in three cases, a slight paraventricular extension was seen. The mean size was 4.5 cm of maximal diameter. Surgical removal was achieved via the transcortical parietal route in 13 cases (65%) and the transcortical temporal route in seven cases (35%). In all cases, complete resection was possible. According to the mRS, 13 patients improved, five remained the same, and two were lost to follow-up. One patient had an increased visual field deficit postoperatively and new hemiparesis and aphasia, but returned to the preoperative level within a few weeks. In one patient, an acute myocardial infarction occurred due to previous cardiac stent placement and in-stent stenosis. Even large trigonal lesions can be resected with low morbidity using a transcortical approach depending on the peritrigonal extension of the tumor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites. Methods A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route. Results Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m2) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium–combined safety end point (OR 3.3, 95% CI 1.5-7.1). Conclusion A heart team–based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium–combined safety end point.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carotid endarterectomy (CEA) reduces the risk of stroke in patients with symptomatic (>50%) and asymptomatic (>60%) carotid artery stenosis. Here we report the midterm results of a microsurgical non-patch technique and compare these findings to those in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The perioperative risk for redo surgical aortic valve replacement (S-AVR) in patients with severe aortic stenosis and prior coronary artery bypass grafting (CABG) is increased. Transcatheter aortic valve implantation (TAVI) represents an alternative. We assessed the perioperative and mid-term clinical outcome of patients undergoing S-AVR or TAVI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is rapidly evolving as an alternative treatment option for elderly patients with severe symptomatic aortic stenosis and excessive risk for surgical intervention. Transcatheter valve-in-valve implantation is an alternative approach to redo-surgery for patients with degeneration of a bioprosthetic valve. Herein are reported three cases of successful transcatheter aortic valve-in-valve implantation for severely regurgitant bioprosthetic valves with a clinical follow up of more than 12 months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two healthy cats underwent elective surgical procedures under general anesthesia. One developed severe esophagitis leading to esophageal rupture, mediastinitis, and pyothorax. The other cat developed esophageal stricture, diverticulum formation, and suspected iatrogenic perforation. Both cats had signs of dysphagia and regurgitation beginning a few days after anesthesia. The first cat also had severe dyspnea due to septic pleural effusion and pneumomediastinum. In the second cat, endoscopy revealed diffuse esophagitis, an esophageal stricture, and a large esophageal diverticulum. Rupture of the esophageal wall occurred while inflating the esophagus for inspection. Due to the poor prognosis, both cats were euthanized. Necropsy revealed severe esophageal changes. Postanesthetic esophagitis has been previously described in dogs and cats; however, severe life-threatening esophageal injuries rarely occur as a sequel to general anesthesia. To the authors' knowledge, esophageal rupture secondary to perianesthetic reflux has never been reported in cats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three horses (age 17 - 23 years) were referred to the equine clinic of the University of Berne due to colic, fever, tachycardia and tachypnea. All horses showed pleural effusion. Clinical findings in 2 of the horses were highly suggestive of an intra-thoracic esophageal perforation. Severe septic pleuropneumonia without suspicion of an esophageal lesion was diagnosed in the 3rd horse. In addition, an 11 year old stallion was referred to the equine clinic for treatment of a presumptive large colon impaction. The horse was given laxatives after nasogastric intubation. Subsequent dramatic clinical deterioration and signs consistent with severe pleuropneumonia suggest that esophageal perforation had occurred when passing the nasogastric tube. All 4 horses were euthanized due to a poor prognosis. Esophageal perforation was diagnosed or confirmed post mortem in all cases. A hypertrophy of the tunica muscularis of the intra-thoracic esophagus was found in 3 of 4 horses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Neoadjuvant treatment is an accepted standard approach for treating locally advanced esophago-gastric adenocarcinomas. Despite a response of the primary tumor, a significant percentage dies from tumor recurrence. The aim of this retrospective exploratory study from two academic centers was to identify predictors of survival and recurrence in histopathologically responding patients. METHODS: Two hundred thirty one patients with adenocarcinomas (esophagus: n = 185, stomach: n = 46, cT3/4, cN0/+, cM0) treated with preoperative chemotherapy (n = 212) or chemoradiotherapy (n = 19) followed by resection achieved a histopathological response (regression 1a: no residual tumor (n = 58), and regression 1b < 10 % residual tumor (n = 173)). RESULTS: The estimated median overall survival was 92.4 months (5-year survival, 56.6 %) for all patients. For patients with regression 1a, median survival is not reached (5-year survival, 71.6 %) compared to patients with regression 1b with 75.3 months median (5-year survival, 52.2 %) (p = 0.031). Patients with a regression 1a had lymph node metastases in 19.0 versus 33.7 % in regression 1b. The ypT-category (p < 0.001), the M-category (p = 0.005), and the type of treatment (p = 0.04) were found to be independent prognostic factors in R0-resected patients. The recurrence rate was 31.7 % (n = 66) (local, 39.4 %; peritoneal carcinomatosis, 25.7 %; distant metastases, 50 %). Recurrence was predicted by female gender (p = 0.013), ypT-category (p = 0.007), and M-category (p = 0.003) in multivariate analysis. CONCLUSION: Response of the primary tumor does not guarantee recurrence-free long-term survival, but histopathological complete responders have better prognosis compared to partial responders. Established prognostic factors strongly influence the outcome, which could, in the future, be used for stratification of adjuvant treatment approaches. Increasing the rate of histopathological complete responders is a valid endpoint for future clinical trials investigating new drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The breadth of material found in surgical pathology services in African countries differs from the common spectrum of "the West". We report our experience of a voluntary work in the pathology departments of Blantyre and Lilongwe, Malawi. During a 6-week period, 405 cases (378 histology and 27 cytology cases) were processed. The vast majority showed significant pathological findings (n = 369; 91.1 %): 175 cases (47.4 %) were non-tumoral conditions with predominance of inflammatory lesions, e.g., schistosomiasis (n = 11) and tuberculosis (n = 11). There were 39 (10.6 %) benign tumors or tumor-like lesions. Intraepithelial neoplasia of the cervix uteri dominated among premalignant conditions (n = 15; 4.1 %). The large group of malignancies (n = 140; 37.9 %) comprised 11 pediatric tumors (e.g., rhabdomyosarcoma, small blue round cell tumors) and 129 adult tumors. Among women (n = 76), squamous cell carcinomas (SCCs) of the cervix uteri predominated (n = 25; 32.9 %), followed by breast carcinomas (n = 12; 15.8 %) and esophageal SCC (n = 9; 11.8 %). Males (n = 53) most often showed SCC of the esophagus (n = 9; 17.0 %) and of the urinary bladder (n = 7; 13.2 %). Lymphomas (n = 7) and Kaposi's sarcomas (n = 6) were less frequent. Differences compared to the western world include the character of the conditions in general, the spectrum of inflammatory lesions, and the young age of adult tumor patients (median 45 years; range 18-87 years). Providing pathology service in a low-resource country may be handicapped by lack of personnel, inadequate material resources, or insufficient infrastructure. Rotating volunteers offer a bridge for capacity building of both personnel and the local medical service; in addition, the volunteer's horizons are broadened professionally and personally.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In clinical diagnostics, it is of outmost importance to correctly identify the source of a metastatic tumor, especially if no apparent primary tumor is present. Tissue-based proteomics might allow correct tumor classification. As a result, we performed MALDI imaging to generate proteomic signatures for different tumors. These signatures were used to classify common cancer types. At first, a cohort comprised of tissue samples from six adenocarcinoma entities located at different organ sites (esophagus, breast, colon, liver, stomach, thyroid gland, n = 171) was classified using two algorithms for a training and test set. For the test set, Support Vector Machine and Random Forest yielded overall accuracies of 82.74 and 81.18%, respectively. Then, colon cancer liver metastasis samples (n = 19) were introduced into the classification. The liver metastasis samples could be discriminated with high accuracy from primary tumors of colon cancer and hepatocellular carcinoma. Additionally, colon cancer liver metastasis samples could be successfully classified by using colon cancer primary tumor samples for the training of the classifier. These findings demonstrate that MALDI imaging-derived proteomic classifiers can discriminate between different tumor types at different organ sites and in the same site.