951 resultados para cylindrical grinding
Resumo:
This study presents the in-vivo evaluation of Ti-13Nb-13Zr alloy implants obtained by the hydride route via powder metallurgy. The cylindrical implants were processed at different sintering and holding times. The implants` were characterized for density, microstructure (SEM), crystalline phases (XRD), and bulk (EDS) and surface composition (XPS). The implants were then sterilized and surgically placed in the central region of the rabbit`s tibiae. Two double fluorescent markers were applied at 2 and 3 weeks, and 6 and 7 weeks after implantation. After an 8-week healing period, the implants were retrieved, non-decalcified section processed, and evaluated by electron, UV light (fluorescent labeling), and light microscopy (toluidine blue). BSE-SEM showed close contact between bone and implants. Fluorescent labeling assessment showed high bone activity levels at regions close to the implant surface. Toluidine blue staining revealed regions comprising osteoblasts at regions of newly forming/formed bone close to the implant surface. The results obtained in this study support biocompatible and osseoconductive properties of Ti-13Nb-13Zr processed through the hydride powder route. (c) 2007 Published by Elsevier B.V.
Resumo:
The chemical and dimensional stability associated with suitable fracture toughness and propitious tribological characteristics make silicon nitride-based ceramics potential candidates for biomedical applications, mainly as orthopedic implants. Considering this combination of properties, silicon nitride components were investigated in relation to their biocompatibility. For this study, two cylindrical implants were installed in each tibia of five rabbits and were kept in the animals for 8 weeks. During the healing time, tissue tracers were administrated in the animals so as to evaluate the bone growth around the implants. Eight weeks after the surgery, the animals were euthanized and histological analyses were performed. No adverse reactions were observed close to the implant. The osteogenesis process occurred during the entire period defined by the tracers. However, this process occurred more intensely 4 weeks after the surgery. In addition, the histological analyses showed that bone growth occurred preferentially in the cortical areas. Different kinds of tissue were identified on the implant surface, characterized by lamellar bone tissue containing osteocytes and osteons, by a noncalcified matrix containing osteoblasts, or by the presence of collagen III, which may change to collagen I or remain as a fibrous tissue. The results demonstrated that silicon nitride obtained according to the procedure proposed in this research is a biocompatible material. (c) 2007 Wiley Periodicals, Inc.
Resumo:
In this paper, the laminar fluid flow of Newtonian and non-Newtonian of aqueous solutions in a tubular membrane is numerically studied. The mathematical formulation, with associated initial and boundary conditions for cylindrical coordinates, comprises the mass conservation, momentum conservation and mass transfer equations. These equations are discretized by using the finite-difference technique on a staggered grid system. Comparisons of the three upwinding schemes for discretization of the non-linear (convective) terms are presented. The effects of several physical parameters on the concentration profile are investigated. The numerical results compare favorably with experimental data and the analytical solutions. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
The paper by Yu and Saupe on the first biaxial nematic phase created excitement for a number of reasons. Some theories of biaxial phases already existed, but experimental observation was still lacking. The phase was discovered in a lyotropic system with three components, which in theory is difficult. Lyotropic liquid crystals are composed of supramolecular assemblies of amphiphilic molecules, which may change shape and size as a function of concentration and temperature. The experimental phase diagram of the lyotropic biaxial phase was rather complex, with the biaxial region inserted between nematic cylindrical and nematic discotic phases via second-order transitions. In addition, re-entrant behaviour was evident. Saupe investigated further systems experimentally, observing that the biaxial phase might be absent in cases where a direct transition between the cylindrical and discotic phases occurred. He provided a range of theoretical and experimental contributions on the properties of these lyotropics, but was very cautious regarding the detailed amphiphilic assemblies involved. The present paper reviews this area, focusing on proposals for the structure of the micellar assemblies. Emphasis is placed on recent papers which indicate a transformation of the two uniaxial shapes, in mixing conditions, both from the theoretical and the experimental point of view, and to questions still requiring further study.
Resumo:
The objective of this study was to evaluate the stress distribution in the resin in contact with the spirals of cylindrical and conical mini-implants, when submitted to lateral load and insertion torsion. A photoelastic model was fabricated using transparent gelatin to simulate the alveolar bone. The model was observed with a plane polariscope and photographically recorded before and after activation of the two screws with a lateral force and torsion. The lateral force application caused bending moments on both mini-implants, with the uprising of fringes or isochromatics, characteristics of stresses, along the threads of the mini-implants and in the apex. When the torsion was exerted in the mini-implants, a great concentration of stress upraised close to the apex. The conclusion was that, comparing conical with cylindrical mini-implants under lateral load, the stresses were similar on the traction sides. The differences appear (1) on the apex, where the cylindrical mini-implant showed a greater concentration of stress, and (2) along the spirals, in the compression side, where the conical mini-implant showed a greater concentration of stress. The greater part of the stress produced by both mini-implants, after torsion load in insertion, were concentrated on the apex. With the cylindrical mini-implant, the greater concentration of tension was close to the apex, while with the conical one, the stresses were distributed along a greater amount of apical threads.
Resumo:
In this paper an analytical solution of the temperature of an opaque material containing two overlapping and parallel subsurface cylinders, illuminated by a modulated light beam, is presented. The method is based on the expansion of plane and cylindrical thermal waves in series of Bessel and Hankel functions. This model is addressed to the study of heat propagation in composite materials with interconnection between inclusions, as is the case of inverse opals and fiber reinforced composites. Measurements on calibrated samples using lock-in infrared thermography confirm the validity of the model.
Resumo:
In this paper, we propose a new method of measuring the very slow paramagnetic ion diffusion coefficient using a commercial high-resolution spectrometer. If there are distinct paramagnetic ions influencing the hydrogen nuclear magnetic relaxation time differently, their diffusion coefficients can be measured separately. A cylindrical phantom filled with Fricke xylenol gel solution and irradiated with gamma rays was used to validate the method. The Fricke xylenol gel solution was prepared with 270 Bloom porcine gelatin, the phantom was irradiated with gamma rays originated from a (60)Co source and a high-resolution 200 MHz nuclear magnetic resonance (NMR) spectrometer was used to obtain the phantom (1)H profile in the presence of a linear magnetic field gradient. By observing the temporal evolution of the phantom NMR profile, an apparent ferric ion diffusion coefficient of 0.50 mu m(2)/ms due to ferric ions diffusion was obtained. In any medical process where the ionizing radiation is used, the dose planning and the dose delivery are the key elements for the patient safety and success of treatment. These points become even more important in modern conformal radio therapy techniques, such as stereotactic radiosurgery, where the delivered dose in a single session of treatment can be an order of magnitude higher than the regular doses of radiotherapy. Several methods have been proposed to obtain the three-dimensional (3-D) dose distribution. Recently, we proposed an alternative method for the 3-D radiation dose mapping, where the ionizing radiation modifies the local relative concentration of Fe(2+)/Fe(3+) in a phantom containing Fricke gel and this variation is associated to the MR image intensity. The smearing of the intensity gradient is proportional to the diffusion coefficient of the Fe(3+) and Fe(2+) in the phantom. There are several methods for measurement of the ionic diffusion using NMR, however, they are applicable when the diffusion is not very slow.
Resumo:
Evidence of the sorption of the whitening agent sodium 4,4`-distyrylbiphenyl sulfonate in the presence of the anionic surfactant sodium dodecylsulfate or the cationic surfactant dodecyl trimethyl ammonium chloride on regenerated cellulose fibers is given by several microscopy techniques. Scanning electron microscopy provided images of the cylindrical fibers with dimensions of 3.5 cm (length) and 13.3 mu m (thickness), with empty cores of 1 mu m diameter and a smooth surface. Atomic force microscopy showed a fiber surface with disoriented nanometric domains using both tapping-mode height and phase image modes. Atomic force microscopy also showed that the whitening agent and surfactant molecules were sorbed onto the fiber surface, in agreement with the adsolubilization sorption model. Transmission electron microscopy showed fibers with nanometric parallel cylinders, surrounded by holes where the fluorescent whitening molecules accumulated. On the basis of these techniques, we conclude that the sorption process occurs preferentially on the fiber surface in contact with the water solution, and under saturated conditions, the whitening agent penetrates into the pores and are simultaneously sorbed on the pore walls bulk, forming molecular aggregates. (C) 2010 Wiley Periodicals, Inc. J Appl Polym Sci 2321-2327, 2010
Resumo:
The interaction of 4-nerolidylcatechol (4-NRC), a potent antioxidant agent, and 2-hydroxypropyl-beta-cyclodextrin (HP-beta-CD) was investigated by the solubility method using Fourier transform infrared (FTIR) methods in addition to UV-Vis, (1)H-nuclear magnetic resonance (NMR) spectroscopy and molecular modeling. The inclusion complexes were prepared using grinding, kneading and freeze-drying methods. According to phase solubility studies in water a B(S)-type diagram was found, displaying a stoichiometry complexation of 2:1 (drug:host) and stability constant of 6494 +/- A 837 M(-1). Stoichiometry was established by the UV spectrophotometer using Job`s plot method and, also confirmed by molecular modeling. Data from (1)H-NMR, and FTIR, experiments also provided formation evidence of an inclusion complex between 4-NRC and HP-beta-CD. 4-NRC complexation indeed led to higher drug solubility and stability which could probably be useful to improve its biological properties and make it available to oral administration and topical formulations.
Resumo:
In this project forging of aluminum alloy Al 6026 T9 has been performed in the temperature range of 400 °C – 470 °C. The alloy which was in the shape of a cylindrical billet was formed in a press with the aim of analyzing the effect of different forging temperatures and required press load for optimal die filling. The component’s dimensions were later measured and compared to a reference piece. To ease the flow of material a lubricant was used between the billet and the die. This was demonstrated by compressing the billet with and without any lubricant.The performed experiments show that the lubricant reduces friction and makes it easier for the material to flow into the die. Higher billet temperature than 450 °C is deemed unnecessary as it does not give any significant improvement in filling the die. The experiments also conclude that a press load of at least 280 tons is required for these conditions.
Resumo:
In this paper, Finite Element method and full-scale experiments have been used to study a hot forging method for fabri-cation of a spindle using reduced initial stock size. The forging sequence is carried out in two stages. In the first stage, the hot rolled cylindrical billet is pre-formed and pierced in a closed die using a spherical nosed punch to within 20 mm of its base. This process of piercing or impact extrusion leads to high strains within the work piece but requires high press loads. In the second stage, the resulting cylinder is placed in a die with a flange chamber and upset forged to form a flange. The stock mass is optimized for complete die filling. Process parameters such as effective strain distribution, material flow and forging load in different stages of the process are analyzed. It is concluded from the simulations that minor modifications of piercing punch geometry to reduce contact between the punch and emerging vertical walls of the cylinder appreciably reduces the piercing load. In the flange chamber, a die surfaces angle of 52° instead of 45° is pro-posed to ensure effective material flow and exert sufficient tool pressure to achieve complete cavity filling. In order to achieve better compression, it is also proposed to shorten both the length of the inserted punch and the die “tongues” by a few mm.
Resumo:
This licentiate thesis has the main focus on evaluation of the wear of coated and uncoated polycrystalline cubic boron nitride cutting tool used in cutting operations against hardened steel. And to exam the surface finish and integrity of the work material used. Harder work material, higher cutting speed and cost reductions result in the development of harder and more wear resistance cutting tools. Although PCBN cutting tools have been used in over 30 years, little work have been done on PVD coated PCBN cutting tools. Therefore hard turning and hard milling experiments with PVD coated and uncoated cutting tools have been performed and evaluated. The coatings used in the present study are TiSiN and TiAlN. The wear scar and surface integrity have been examined with help of several different characterization techniques, for example scanning electron microscopy and Auger electron spectroscopy. The results showed that the PCBN cutting tools used displayed crater wear, flank wear and edge micro chipping. While the influence of the coating on the crater and flank wear was very small and the coating showed a high tendency to spalling. Scratch testing of coated PCBN showed that, the TiAlN coating resulted in major adhesive fractures. This displays the importance of understanding the effect of different types of lapping/grinding processes in the pre-treatment of hard and super hard substrate materials and the amount and type of damage that they can create. For the cutting tools used in turning, patches of a adhered layer, mainly consisting of FexOy were shown at both the crater and flank. And for the cutting tools used in milling a tribofilm consisting of SixOy covered the crater. A combination of tribochemical reactions, adhesive wear and mild abrasive wear is believed to control the flank and crater wear of the PCBN cutting tools. On a microscopic scale the difference phases of the PCBN cutting tool used in turning showed different wear characteristics. The machined surface of the work material showed a smooth surface with a Ra-value in the range of 100-200 nm for the turned surface and 100-150 nm for the milled surface. With increasing crater and flank wear in combination with edge chipping the machined surface becomes rougher and showed a higher Ra-value. For the cutting tools used in milling the tendency to micro edge chipping was significant higher when milling the tools steels showing a higher hard phase content and a lower heat conductivity resulting in higher mechanical and thermal stresses at the cutting edge.
Resumo:
A geração de resíduos tem se mostrado um problema de preocupação mundial crescente. Muitos rejeitos, sejam industriais ou urbanos, muitas vezes acabam por poluir o meio-ambiente, causando problemas de armazenagem de certos materiais. Além disso, materiais alternativos a partir desses rejeitos podem ser mais baratos, apresentando muitas vezes características de desempenho melhores que os materiais convencionais. As siderúrgicas, em nível mundial, vêm enfrentando um problema comum, que consiste no que fazer para que a totalidade da escória gerada no refino do aço em aciarias elétricas ou à oxigênio tenha uma solução de aproveitamento melhor do que vem sendo feito atualmente. Na fabricação do aço as escorias são geradas em duas etapas: a primeira provém do chamado refino oxidante (forno elétrico a arco ou convertedor à oxigênio) e a segunda do refino redutor em processos de metalurgia na panela (forno-panela). Este trabalho tem como objetivo principal o de apontar potencialidades de uso da escória de aciaria elétrica, com destaque para a proveniente do forno-panela (escória do refino redutor), na indústria da construção civil através de testes em que a escória é utilizada, após moagem, como adição ao cimento Portland comum. Inicialmente foram realizados ensaios de viabilização para se testar a pozolanicidade, resistência à compressão, expansibilidade e profundidade de carbonatação de concretos gerados com diversas adições de escórias de aciaria elétrica. Comprovada a sua viabilidade partiu-se para os ensaios complementares do trabalho utilizando-se somente uma escória do refino redutor. Nesta segunda etapa foram realizados ensaios de caracterização de todos materiais estudados, ensaios de expansibilidade, ensaios mecânicos e de durabilidade dos concretos gerados com esta escória e ensaios de microscopia eletrônica de varredura e de difração de raios X do material. Após o estudo realizado comprovou-se ser perfeitamente viável a utilização de até 10% da escória do refino redutor (forno-panela- FP) como adição ao cimento para produção de concretos. Inclusive, independente do tempo de estocagem da escória, pode-se constatar melhorias no concreto produzido.
Resumo:
Foram estudadas as características de floculação da hidro-xiapatita, calcita e quartzo com poliacrilamidas aniônicas. Tanto as suspensões de hidroxiapatita como a calcita foram completamente floculadas enquanto que o quartzo foi refratário a floculação com esses polimeros. Entretanto, observou-se que a floculação da calcita foi impedida com a utilização de um poliacrilato de sódio, enquanto que a hidroxiapatita continuou a ser floculada pela poliacrilamida num intervalo de concentração de O a 1000 g/ton de poliacrilato. Estes resultados permitiram estabelecer condições para a floculação seletiva de hidroxiapatita em misturas sintéticas com quartzo e calcita. Nestes sistemas foram estudados diversos parâmetros operacionais, tais como tipo de separação, efeito do teor da alimentação, e influência da moagem. Onde a separação estagiada apresentou melhor resultado, uma moagem adicional no sistema não favoreceu a seletividade. Por outro lado, o teor de P205 no concentrado é proporcional ao teor presente na alimentação. A hidroxiapatita, em estudo, de alta pureza (de acordo com técnicas de análise química, espectrofotometria de infravermelho e difração de raios X) apresentou um parto de carga zero em pH 6,77 na presença de diversos eletrólitos. A aplicação do sistema de floculação seletiva a fraçoes ultrafinas industriais foi estudada em detalhe e comparada com processos de flotação e floco-flatação. 0s resultados obtidos mostraram que a floculação seletiva somente foi eficiente nos sistemas sintéticos. A flotação, embora o minério apresente uma granulometria muito fina, foi mais eficiente que a floculação seletiva e a floco-flotação nos sistemas reais, em termos de taxa de enriquecimento e percentual de rejeição de massa. Entretanto com a floco-flotação foi possivel obter altas recuperações(-90%) para os minérios de Araxá e Itataia. Para o minério de Tapira, um aumento do teor de P2O5 foi obtido com a flotação da fração seletivamente floculada. As taxas de enriquecimento obtidas foram baixas (entre 1,35 e 2,101 em função das associações entre a apatita do minério com óxido de ferro e argila, o que revelou a caracterização mineralógica. Conclue-se que a concentração de minerios fosfatados de baixo teor é uma operação onerosa, onde o fator predominante é a absorção seletiva de reagentes e atransferência não específica de material de ganga nos respectivos concentrados.
Resumo:
R.R.M. de Sousa et al. Nitriding in cathodic cage of stainless steel AISI 316: Influence of sample position. Vacuum, [s.l.], n.83, 2009. Disponivel em: