940 resultados para correlation coefficient analysis
Resumo:
INTRODUCTION: Self-reported weight and height were compared with direct measurements in order to evaluate the agreement between the two sources. METHOD: Data were obtained from a cross-sectional study on health status from a probabilistic sample of 1,183 employees of a bank, in Rio de Janeiro State, Brazil. Direct measurements were made of 322 employees. Differences between the two sources were evaluated using mean differences, limits of agreement and intraclass correlation coefficient (ICC). RESULTS AND CONCLUSIONS: Men and women tended to underestimate their weight while differences between self-reported and measured height were insignificant. Body mass index (BMI) mean differences were smaller than those observed for weight. ICC was over 0.98 for weight and 0.95 for BMI, expressing close agreement. Combining a graphical method with ICC may be useful in pilot studies to detect populational groups capable of providing reliable information on weight and height, thus minimizing resources needed for field work.
Resumo:
OBJECTIVE: To evaluate the reliability and validity of the Portuguese version of the Women's Health Questionnaire. METHODS: In order to evaluate the Women's Health Questionnaire (WHQ), an analytical cross-sectional study was carried out at the women's menopause outpatient clinic of a university hospital in São Paulo, Brazil. There were studied 87 women in perimenopause or menopause, defined as experiencing at least one year's absence of menstrual flow. The following variables were collected: demographic data, clinical variables (Kupperman index and correlate numeric scale) and quality of life indexes (SF-36 and utility). RESULTS: The WHQ proved to be a questionnaire easily translated into Portuguese and well-adjusted to Brazilian women. The internal consistency of the overall WHQ was excellent (Cronbach alpha =0.83; 95% CI: 0.71-0.91). Test-retest reliability was also excellent (intraclass correlation coefficient [ICC]=0.92; 95% IC: 0.86-0.96) and had good absolute agreement (0.84; 95% CI: 0.71-0.92). A satisfactory clinical validity was observed. The construct validity was corroborated by clear associations with others scales. A good index of responsiveness after the intervention was reached. CONCLUSIONS: The Portuguese version of the WHQ is of easy and fast administration and understanding. Its measuring properties were related, allowing its use in the evaluation of Brazilian climacteric women's quality of life for various purposes.
Resumo:
Introdução – A cintigrafia de perfusão do miocárdio (CPM) é um dos exames complementares de diagnóstico mais indicados na patologia cardiovascular. A atividade extramiocárdica é um problema recorrente na aquisição e avaliação da imagem. Parâmetros como o radiofármaco (RF) administrado, o tipo de esforço, a ingestão de alimentos, o posicionamento e o processamento de imagem influenciam a atividade extramiocárdica na CPM. O objetivo deste estudo é identificar o protocolo da CPM a nível nacional e avaliar a percentagem de repetições das aquisições provocadas por este problema. Metodologia – Para a realização deste estudo, a população selecionada foram os Serviços de Medicina Nuclear (SMN) em Portugal Continental. Foram analisados 15 questionários, respondidos pelos Técnicos Coordenadores dos vários SMN. Foi realizada a associação do comportamento das variáveis, através da estatística descritiva e do Coeficiente de Correlação de Spearman. Resultados – A percentagem de repetições é menor com o uso da 99mTecnécio(Tc)-Tetrofosmina, aquisição de imagens tardias, ingestão de diversos alimentos (água, leite, sumo, pão com manteiga) e com a correção de atenuação. Conclusão – Os resultados obtidos demonstram que a maioria das soluções aplicadas nos SMN resultam numa diminuição das repetições.
Resumo:
OBJECTIVE: To assess the relationship between locus of control and knowledge, attitude and practice regarding pill and condom use among university students. METHODS: The inquiry was developed in Campinas, a city in Southeastern Brazil, in 2006. A total of 295 adolescent newcomers to a public university answered a structured questionnaire and Levenson's multidimensional locus of control scale. The scores of the dimensions of locus of control were calculated and Spearman's correlation coefficient was used to assess their correlation with knowledge and practice concerning pill and condom use. In order to assess the relationship between the dimensions of locus of control and sociodemographic variables and variables related to the individuals' sex life, Kruskal-Wallis and Mann-Whitney tests were used. RESULTS: Male adolescents had higher scores of powerful others externality when compared to female adolescents (p=0.01). Students living alone had lower internality (p=0.01). When locus of control was compared to condom use in the first intercourse, considering only the 102 students who informed the age of the beginning of sexual activity, greater internality was found among male adolescents who did not use condoms (p<0.05). When the locus of control scores were correlated with contraceptive knowledge and practice, it was found that the higher the powerful others externality locus, the lower the adequate use of contraceptive methods (r = -0.22, p=0.03). CONCLUSIONS: The powerful others externality locus influences the practice of contraceptive use in this group of adolescents.
Resumo:
OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.
Resumo:
ABSTRACT OBJECTIVE : To evaluate the validity and reliability of the Questionnaire for Compliance with Standard Precaution for nurses. METHODS : This methodological study was conducted with 121 nurses from health care facilities in Sao Paulo's countryside, who were represented by two high-complexity and by three average-complexity health care facilities. Internal consistency was calculated using Cronbach's alpha and stability was calculated by the intraclass correlation coefficient, through test-retest. Convergent, discriminant, and known-groups construct validity techniques were conducted. RESULTS : The questionnaire was found to be reliable (Cronbach's alpha: 0.80; intraclass correlation coefficient: (0.97) In regards to the convergent and discriminant construct validity, strong correlation was found between compliance to standard precautions, the perception of a safe environment, and the smaller perception of obstacles to follow such precautions (r = 0.614 and r = 0.537, respectively). The nurses who were trained on the standard precautions and worked on the health care facilities of higher complexity were shown to comply more (p = 0.028 and p = 0.006, respectively). CONCLUSIONS : The Brazilian version of the Questionnaire for Compliance with Standard Precaution was shown to be valid and reliable. Further investigation must be conducted with nurse samples that are more representative of the Brazilian reality. The use of the questionnaire may support the creation of educational measures considering the possible gaps that can be identified, focusing on the workers' health and on the patients' safety.
Resumo:
ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2) for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.
Resumo:
Thirty-two patients bitten by venomous snakes sixteen by Bothrops spp. and sixteen by Crotalus durissus terrificus were studied. The group comprised thirty males and two females, aged eight to sixty-three years (mean 33±15). Bromsulphalein tests were increased in the majority of patients bitten by Crotalus durissus terrificus. The correlation coefficient of Spearman was positive between bromsulphalein tests and alanine aminotransferase levels, and between alanine aminotransferase and aspartate aminotransferase levels only in the Crotalus group. The only patient who died was bitten by Crotalus durissus terrificus and showed hydropic degeneration and mitochondrial injury in the liver. It was concluded that the hepatic damage might have been caused by at least two possible mechanisms: venom effect on liver mitochondria and cytokine effects on hepatocyte, specially interleukin-6.
Resumo:
A simple method of rubella antigen production by treatment with sodium desoxycholate for use in enzyme immunoassay (IMT-ELISA) is presented. When this assay was compared with a commercial test (Enzygnost-Rubella, Behring), in the study of 108 sera and 118 filter paper blood samples, 96.9% (219/226) overall agreement and correlation coefficient of 0.90 between absorbances were observed. Seven samples showed discordant results, negative by the commercial kit and positive by our test. Four of those 7 samples were available, being 3 positive by HI.
Resumo:
O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.
Resumo:
Purpose: This exploratory research evaluates if there is a relationship between the number of years since an organization has achieved ISO 9001 certification and the highest level of recognition received by the same organization with the EFQM Business Excellence Model. Methodology/Approach: After state of the art review a detailed comparison between both models was made. Fifty two Portuguese organizations were considered and Correlation coefficient Spearman Rho was used to investigate the possible relationships. Findings: Conclusion is that there is indeed a moderate positive correlation between these two variables, the higher the number of years of ISO 9001 certification, the higher the results of the organization EFQM model evaluation and recognition. This supports the assumption that ISO 9001 International Standard by incorporating many of the principles present in the EFQM Business Excellence Model is consistent with this model and can be considered as a step towards that direction. Research Limitation/implication: Due to the dynamic nature of these models that might change over time and the possible time delays between implementation and results, more in-depth studies like experimental design or a longitudinal quasi-experimental design could be used to confirm the results of this investigation. Originality/Value of paper: This research gives additional insights on conjunct studies of both models. The use of external evaluation results carried out by the independent EFQM assessors minimizes the possible bias of previous studies accessing the value of ISO 9001 certification.
Resumo:
Dissertation to Obtain the Degree of Master in Biomedical Engineering
Resumo:
The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .
Resumo:
The therapeutic approach to severe pulmonary arterial hypertension (PAH), whether primary or secondary to connective tissue disorders, thromboembolic phenomena or congenital heart disease with Eisenmenger syndrome, has evolved in recent years following the introduction of selective pulmonary vasodilators, including prostacyclin analogs and endothelin receptor antagonists. AIM: To correlate three different endpoints (6-minute walk test, Tei index and peak tricuspid regurgitation velocity by Doppler echocardiographic study) during follow-up of PAH patients under selective vasodilator therapy. METHODS: Eleven patients (9 female, age 42 +/- 18 years) with severe PAH (> or = 65 mmHg), 64% with Eisenmenger syndrome, in NYHA class > or = II, were assessed during a follow-up of 11 +/- 8 months. Eight patients were already under therapy with iloprost or bosentan. RESULTS: There was no correlation between the three endpoints before and after therapy as assessed by Pearson's correlation coefficient. There was, however, an improvement in all of them after selective vasodilatory therapy. CONCLUSION: Therapeutic response can be accurately measured by the traditional endpoint (6-minute walk test) or by echocardiographic endpoints. However, the lack of correlation between them excludes their use as alternatives in patient follow-up.
Resumo:
This study aims to compare two methods of assessing the postural phase of gait initiation as to intrasession reliability, in healthy and post-stroke subjects. As a secondary aim, this study aims to analyse anticipatory postural adjustments during gait initiation based on the centre of pressure (CoP) displacements in post-stroke participants. The CoP signal was acquired during gait initiation in fifteen post-stroke subjects and twenty-three healthy controls. Postural phase was identified through a baseline-based method and a maximal displacement based method. In both healthy and post-stroke participants higher intra-class correlation coefficient and lower coefficient of variation values were obtained with the baseline-based method when compared to the maximal displacement based method. Post-stroke participants presented decreased CoP displacement backward and toward the first swing limb compared to controls when the baseline-based method was used. With the maximal displacement based method, there were differences between groups only regarding backward CoP displacement. Postural phase duration in medial-lateral direction was also increased in post-stroke participants when using the maximal displacement based method. The findings obtained indicate that the baseline-based method is more reliable detecting the onset of gait initiation in both groups, while the maximal displacement based method presents greater sensitivity for post-stroke participants.