966 resultados para Transient Calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a study on concrete fracture and the associated mesh sensitivity using the finite element (FE) method with a local concrete model in both tension (Mode I) and compression.To enable the incorporation of dynamic loading, the FE model is developed using a transient dynamic analysis code LS-DYNA Explicit.A series of investigations have been conducted on typical fracture scenarios to evaluate the model performances and calibration of relevant parameters.The K&C damage model was adopted because it is a comprehensive local concrete model which allows the user to change the crack band width, fracture energy and rate dependency of the material.Compressive localisation modelling in numerical modelling is also discussed in detail in relation to localisation.An impact test specimen is modelled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient and robust case sorting algorithm based on Extended Equal Area Criterion (EEAC) is proposed in this paper for power system transient stability assessment (TSA). The time-varying degree of an equivalent image system can be deduced by comparing the analysis results of Static EEAC (SEEAC) and Dynamic EEAC (DEEAC), the former of which neglects all time-varying factors while the latter partially considers the time-varying factors. Case sorting rules according to their transient stability severity are set combining the time-varying degree and fault messages. Then a case sorting algorithm is designed with the OR logic among multiple rules, based on which each case can be identified into one of the following five categories, namely stable, suspected stable, marginal, suspected unstable and unstable. The performance of this algorithm is verified by studying 1652 contingency cases from 9 real Chinese provincial power systems under various operating conditions. It is shown that desirable classification accuracy can be achieved for all the contingency cases at the cost of very little extra computational burden and only 9.81% of the whole cases need to carry out further detailed calculation in rigorous on-line TSA conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present photometric and spectroscopic observations of the interacting transient SN 2009ip taken during the 2013 and 2014 observing seasons. We characterize the photometric evolution as a steady and smooth decline in all bands, with a decline rate that is slower than expected for a solely Co-56-powered supernova at late phases. No further outbursts or eruptions were seen over a two year period from 2012 December until 2014 December. SN 2009ip remains brighter than its historic minimum from pre-discovery images. Spectroscopically, SN 2009ip continues to be dominated by strong, narrow (less than or similar to 2000 km s(-1)) emission lines of H, He, Ca, and Fe. While we make tenuous detections of [Fe II] lambda 7155 and [O I] lambda lambda 6300, 6364 lines at the end of 2013 June and the start of 2013 October, respectively, we see no strong broad nebular emission lines that could point to a core-collapse origin. In general, the lines appear relatively symmetric, with the exception of our final spectrum in 2014 May, when we observe the appearance of a redshifted shoulder of emission at +550 km s(-1). The lines are not blueshifted, and we see no significant near-or mid-infrared excess. From the spectroscopic and photometric evolution of SN 2009ip until 820 d after the start of the 2012a event, we still see no conclusive evidence for core-collapse, although whether any such signs could be masked by ongoing interaction is unclear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

<p>The paper presents the calibration of Fuji BAS-TR image plate (IP) response to high energy carbon ions of different charge states by employing an intense laser-driven ion source, which allowed access to carbon energies up to 270 MeV. The calibration method consists of employing a Thomson parabola spectrometer to separate and spectrally resolve different ion species, and a slotted CR-39 solid state detector overlayed onto an image plate for an absolute calibration of the IP signal. An empirical response function was obtained which can be reasonably extrapolated to higher ion energies. The experimental data also show that the IP response is independent of ion charge states.</p>

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pathogenesis of Alzheimer's disease (AD) is complex involving multiple contributing factors. The extent to which AD pathology impacts upon the metabolome is still not understood, nor is it known how disturbances change as the disease progresses. For the first time we have profiled longitudinally (6, 8, 10, 12 and 18 months) both the brain and plasma metabolome of APP/PS1 double transgenic and wild type (WT) mice. A total of 187 metabolites were quantified using a targeted metabolomics methodology. Multivariate statistical analysis produced models that distinguished APP/PS1 from WT mice at 8, 10 and 12 months.Metabolic pathway analysis found perturbed polyamine metabolism in both brain and blood plasma. There were other disturbances in essential amino acids,branched chain amino acids and also in the neurotransmitter serotonin.Pronounced imbalances in phospholipid and acylcarnitine homeostasis was evident in two age groups. AD-like pathology therefore impacts greatly on both the brain and blood metabolomes, although there appears to be a clear temporal sequence whereby changes to brain metabolites precede those in blood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Transient receptor potential (TRP) channels are widely, but not uniformly, distributed in tissues. To date the dominant focus of attention has been on TRP expression and functionality in neurons. However, their expression and activation in selected non-neuronal cells suggest TRPs have a potential role in coordinating cross-talk during the inflammatory process. Fibroblasts comprise the major cell type in the dental pulp and play an important role in pulpal inflammation. Objectives: The aim of this study was to investigate the expression and functionality of the TRP channels TRPA1, TRPM8, TRPV4 and TRPV1 in human dental pulp fibroblasts. Methods: Dental pulp fibroblasts were derived by explant culture of pulps removed from extracted healthy teeth. Fibroblasts were cultured in DMEM supplemented with 10% FCS, 100U/ml penicillin and 100g/ml streptomycin. Protein expression of TRP channels was investigated by SDS- polyacrylamide gel electrophoresis and Western blotting of cell lysates from fibroblast cells in culture. TRPA1, TRPM8, TRPV4 and TRPV1 expression was determined by specific antibodies, detected using appropriate anti-species antibodies and chemiluminescence. Functionality of TRP channels was determined by Ca2+ microfluorimetry. Cells were grown on cover slips and incubated with Fura 2AM prior to stimulation with icilin (TRPA1 agonist), menthol (TRPM8 agonist), 4 alpha-phorbol 12,13-didecanoate (4alphaPDD) (TRPV4 agonist) or capsaicin (TRPV1 agonist). Emitted fluorescence (F340/F380) was used to determine intracellular [Ca2+] levels. Results: Fibroblast expression of TRPA1, TRPM8, TRPV4 and TRPV1 was confirmed at the protein level by Western blotting. Increased intracellular [Ca2+] levels in response to icillin, methanol, 4alphaPDD and capsacin, indicated functional expression of TRPA1, TRPM8, TRPV4 and TRPV respectively. Conclusions: The presence and functionality of TRP channels on dental pulp fibroblasts suggests a potential role for these cells in the pulpal neurogenic inflammatory response. (Supported by a research grant from the Royal College of Surgeons of Edinburgh).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-mass stars are highly interesting targets: we are able to detect planets in their habitable zones, and upcoming searches for biomarkers in exoplanet atmospheres will focus on low-mass star systems due to their ubiquity and proximity. We aim to develop an age-activity calibration for old low-mass stars, using wide binary systems consisting of an M or K dwarf and a white dwarf. The age of the system is determined by the WD cooling time plus its progenitor lifetime, yielding reliable ages in the regime &gt;1 Gyr. For an exploratory sample of 7 systems where we have already derived ages, we propose to perform Chandra ACIS-S observations to determine the X-ray luminosities of the M dwarfs and correlate their stellar activity with age. We ask for a total observing time of 110 ks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ria deAveiro is a very complex shallow water coastal lagoon located on the northwest of Portugal. Important issues would be left unanswered without a good understanding of hydrodynamic and transport processes occurring in the lagoon. Calibration and validation of hydrodynamic, salt and heat transport models for Ria de Aveiro lagoon are presented. The calibration of the hydrodynamic model was performed adjusting the bottom friction coefficient, through the comparison between measured and predicted time series of sea surface elevation for 22 stations. Harmonic analysis was performed in order to evaluate the model's accuracy. To validate the hydrodynamic model measured and predicted SSE values were compared for 11 stations, as well as main flow direction velocities for 10 stations. The salt and heat transport models were calibrated comparing measured and predicted time series of salinity and water temperature for 7 stations, and the RMS of the difference between the series was determined. These models were validated comparing the model results with an independent field data set. The hydrodynamic and the salt and heat transport models for Ria de Aveiro were successfully calibrated and validated. They reproduce accurately the barotropic flows and can therefore adequately represent the salt and heat transport and the heat transfer processes occurring in Ria deAveiro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ao longo das ltimas dcadas, a micromoldao (u-moldao) por injeo de termoplsticos ganhou um lugar de destaque no mercado de equipamentos eletrnicos e de uma ampla gama de componentes mecnicos. No entanto, quando o tamanho do componente diminui, os pressupostos geralmente aceites na moldao por injeo convencional deixam de ser vlidos para descrever o comportamento reolgico e termomecnico do polmero na microimpresso. Por isso, a compreenso do comportamento dinmico do polmero escala micro bem como da sua caraterizao, anlise e previso das propriedades mecnicas exige uma investigao mais alargada. O objetivo principal deste programa doutoral passa por uma melhor compreenso do fenmeno fsico intrnseco ao processo da -moldao por injeo. Para cumprir com o objetivo estabelecido, foi efetuado um estudo paramtrico do processo de -moldao por injeo, cujos resultados foram comparados com os resultados obtidos por simulao numrica. A caracterizao dinmica mecnica das -peas foi efetuada com o objetivo de recolher os dados necessrios para a previso do desempenho mecnico das mesmas, a longo prazo. Finalmente, depois da calibrao do modelo matemtico do polmero, foram realizadas anlises estruturais com o intuito de prever o desempenho mecnico das -peas no longo prazo. Verificou-se que o desempenho mecnico das -peas pode ser significativamente afetado pelas tenses residuais de origem mecnica e trmica. Estas ltimas, resultantes do processo de fabrico e das condies de processamento, por isso, devem ser consideradas na previso do desempenho mecnico e do tempo de servio das u-moldaes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a new instrument for the measurement of convective and radiative is proposed, based on the transient operation of a transpiration radiometer. Current transpiration radiometers rely on steady state temperature measurements in a porous element crossed by a know gas mass flow. As a consequence of the porous sensing elements intrinsically high thermal inertia, the instruments time constant is in the order of several seconds. The proposed instrument preserves established advantages of transpiration radiometers while incorporating additional features that broaden its applicability range. The most important developments are a significant reduction of the instruments response time and the possibility of separating and measuring the convective and radiative components of the heat flux. These objectives are achieved through the analysis of the instruments transient response, a pulsed gas flow being used to induce the transient behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertao de mest., Recursos Hdricos, Faculdade de Cincias e Tecnologia, Univ. do Algarve, 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As wind power generation undergoes rapid growth, new technical challenges emerge: dynamic stability and power quality. The influence of wind speed disturbances and a pitch control malfunction on the quality of the energy injected into the electric grid is studied for variable-speed wind turbines with different power-electronic converter topologies. Additionally, a new control strategy is proposed for the variable-speed operation of wind turbines with permanent magnet synchronous generators. The performance of disturbance attenuation and system robustness is ascertained. Simulation results are presented and conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.