997 resultados para Transforming Protein


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Biochemistry at the Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain a PhD degree in Biochemistry at Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last fifty years mobility practices have changed dramatically, improving the way travel takes place, the time it takes but also on matters like road safety and prevention. High mortality caused by high accident levels has reached untenable levels. But the research into road mortality stayed limited to comparative statistical exercises which go no further than defining accident types. In terms of sharing information and mapping accidents, little progress has been mad, aside from the normal publication of figures, either through simplistic tables or web pages. With considerable technological advances on geographical information technologies, research and development stayed rather static with only a few good examples on dynamic mapping. The use of Global Positioning System (GPS) devices as normal equipments on automobile industry resulted in a more dynamic mobility patterns but also with higher degrees of uncertainty on road traffic. This paper describes a road accident georeferencing project for the Lisbon District involving fatalities and serious injuries during 2007. In the initial phase, individual information summaries were compiled giving information on accidents and its majour characteristics, collected by the security forces: the Public Safety Police Force (Polícia de Segurança Pública - PSP) and the National Guard (Guarda Nacional Republicana - GNR). The Google Earth platform was used to georeference the information in order to inform the public and the authorities of the accident locations, the nature of the location, and the causes and consequences of the accidents. This paper also gives future insights about augmented reality technologies, considered crucial to advances to road safety and prevention studies. At the end, this exercise could be considered a success because of numerous consequences, as for stakeholders who decide what to do but also for the public awareness to the problem of road mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Febs Journal (2009)276:1776-1786

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess vitamin A status and association between acute diarrhoea and plasma levels of vitamin A through cross-sectional comparison in children. Plasma vitamin A was measured by colorimetric method of Neeld & Pearson and RBP by radial immunodiffusion technique. Seventy eight children (aged 18-119 months), 26 with current history of diarrhoea and 52 children as controls (outpatient from the Santa Casa de Misericórdia Hospital in metropolitan area of São Paulo City, Brazil) were studied. Children with history of diarrhoea showed significant low levels (mean ± s.e.) as compared to controls, vitamin A (15.87 ± 1.4 µg/dl vs. 21.14 ± 1.15 µg/dl, p < 0.007) and RBP (1.70 ± 0.2 mg/dl vs. 2.52 ±0.11 mg/dl). Multivariate logistic regression adjusted by sex, age, nutritional status and mother education revealed association between diarrhoea and inadequate levels of vitamin A and RBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Doutoramento (Ph.D.) degree in Biochemistry at the Instituto de Tecnologia Qu mica e Biol ogica da Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the analysis of 10 batches of L.major-like and L.(V.) braziliensis antigens added or not of a proteases inhibitor evaluated by means of an IgG-ELISA on three consecutive days using positive standard sera from patients with diagnosis of American Leishmaniasis previously tested for the presence of IgG antibodies by means of ELISA. The statistical analysis showed that for L. (V.) braziliensis the PMSF-containing antigen did not show any difference among batches or days of testing; the L.(V.) braziliensis antigen without PMSF showed statistical significance for differences among batches and a two-way ANOVA showed significant differences between antigens. L.major-like antigen prepared with or without PMSF showed differences among batches; all 3 days of testing displayed differences for the PMSF antigen but only for days 1 and 2 for the antigen without inhibitor. A two-way ANOVA showed differences among batches of the antigens but not for antigens with and without the protein inhibitor. According to the statistical analysis the L.major-like antigen added or not of PMSF has shown that it is the choice antigen for mucocutaneous leishmaniasis serology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PLOS ONE, 4(8):ARTe6820

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Germfree (GF) and conventional (CV) mice were fed on diets containing 4.4, 13.2 or 26.4% of protein (weight/weight). CV mice fed on low protein diet did not gain weight during four weeks, whereas the protein deficient diet did not affect the growth of GF mice. After four weeks on these diets, the mice were inoculated with 5x103 trypomastigotes of Trypanosoma cruzi. The protein deficiency affected less the GF than the CV mice, according to the following parameters: weight gain, hemoglobin, plasma protein and albumin levels and water and protein contents of the carcass. Infection with T. cruzi produced a significant decrease in hemoglobin levels, red blood cell count, and water and protein contents in the carcass. This decrease was more pronounced in the GF mice. Histopathologically, there was no difference between the treatments in animals with the same microbiological status (GF or CV). However, the disease was more severe in the GF than in the CV mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Developmental Biology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Bioquímica,especialidade Bioquímica Física,pela Universidade Nova de Lisboa,Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.