903 resultados para Signal interference


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and sensitive method for determining atmospheric ammonia (NH3), using a hanging drop, is described. A colorimetric sensor is composed of two optical fibers and the source of monochromatic light implemented was a red light emitting diode (LED) (635 nm). Preliminary experiments were carried out in order to optimize the geometry of the sensor. These tests showed that the best signal absorbance was obtained using a 22 muL deionized water drop for sampling the gas and as addition of 4 muL of each of the reactants to form the blue dye (indophenol). Some important analytical parameters were also studied, including sampling time and flow rate. The analytical curve was constructed with a concentration range of 3-20 ppbv of gaseous NH3 standard. The detection limit reached was of ca 0.5 ppbv. It was observed that formaldehyde and diethylamine did not interfere. However, studies showed that hydrogen sulfide caused a negative interference of 20%, when present in the atmosphere in a concentration equal to that of NE3. The method considered here was shown to be easy to apply, making it possible to make a determination every 17 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a spectrophotometric method for the determination of hydrogen peroxide during photodegradation reactions. The method is based on the reaction of H2O2 with amonium metavanadate in acidic medium, which results in the formation of a red-orange color peroxovanadium cation, with maximum absorbance at 450 nm. The method was optimized using the multivariate analysis providing the minimum concentration of vanadate (6.2 mmol L-1) for the maximum absorbance signal. Under these conditions, the detection limit is 143 mu mol L-1. The reaction product showed to be very stable for samples of peroxide concentrations up to 3 mmol L-1 at room temperature during 180 h. For higher concentrations however, samples must be kept refrigerated (4 degrees C) or diluted. The method showed no interference of Cl- (0.2-1.3 mmol L-1), NO3- (0.3-1.0 mmol L-1), Fe3+, (0.2-1.2 mmol L-1) and 2,4-dichlorophenol (DCP) (0.2-1.0 mmol L-1). When compared to iodometric titration, the vanadate method showed a good agreament. The method was applied for the evaluation of peroxide consumption during photo-Fenton degradation of 2,4-dichlorophenol using blacklight irradiation. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a novel approach for the analysis of selected aldehydes (formaldehyde, acetaldehyde, propionaldehyde, and acrolein) and acetone in environmental samples using micellar electrokinetic chromatography (MEKC). The method is based on the reaction of carbonyl compounds with 3-methyl-2-benzothiazoline hydrazone (MBTH) that gives an azine intermediate with maximum absorbance at 216 nm. A systematic evaluation of sample dissolution medium was conducted as a means to enhancing sensitivity. In the best condition, samples were dissolved in 0.030 mol.L-1 tetraborate solution. This condition presented enhancement factors in the range of 35-54 for the aldehydes under investigation, computed as the improvement of the concentration limits of detection (LODs) with reference to the sample dissolved in pure water. The running buffer was 0.020 mol.L-1 tetraborate, pH 9.3, containing 0.050 mol-L-1 sodium dodecyly sulfate (SIDS). The overall methodology presented several advantages over established methods for aldehydes. Worthy mentioning that MBTH is available in high purity degree, dispensing laborious reagent purification procedures. A few method validation parameters were determined revealing good migration time repeatability (< 2.5% coefficient of variation, CV) and area repeatability (< 4% CV), excellent linearity (20-120 mug/L, r > 0.995) and adequate sensitivity for environmental applications. The LODs with respect to each single aldehyde were in the range of 0.54-4.0 mug.L-1 and 11 mug.L-1 for acetone. The methodology was applied to the determination of aldehydes indoors. Samples were collected in an impinger flask containing 0.05% MBTH solution, at a flow rate of 0.80 L.min(-1), during 2.5 h, at different times during the day. The most abundant carbonyls in the samples were acetone, followed by formaldehyde and acetaldehyde, with estimate peak concentrations of 452, 5.2 and 2.2 ppbv, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experiment was carried out to evaluate the effects of two moisture levels (18-20% and 13-15%) and three anhydrous ammonia levels (0.0; 1.5; 3.0% of NH3) on the quality of Brachiaria decumbens Stapf hay. The hay was bailed in April and weighed and treated under plastic cover during 30 days. The hay presented a similar chemical composition when bailed with high or low moisture. The percentages of NDF (80.59; 77.61; 76.10%); hemicellulose (32.56; 29.48; 28.76%) and lignin (9.53; 8.21; 7.54% decreased and the percentages of crude protein (4.04; 11.35; 13.22%) and IVDMD (36.78; 49.72; 54.33%) increased as the NH3 level increased. The fractions ADF, cellulose, and ADIN did not change due to the ammoniation. The incidence of fungi decreased with application of NH3 being the better results obtained with the 1.5% treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the maximum residual signal auto-correlation also known as pitch amplitude (PA) values in patients with Parkinson's disease (PD) patients. Method. The signals of 21 Parkinson's patients were compared with 15 healthy individuals, divided according age and gender. Results: Statistical difference was seen between groups for PA, 0.39 for controls and 0.25 for PD. Normal value threshold was set as 0.3; (p <= 0.001). In the Parkinson's group 80.77%, and in the control group only 12.28%, had a PA < 0.3 demonstrating an association between these variables. The dispersion diagram for age and PA for PD individuals showed p=0.01 and r=0.54. There was no significant difference in relation to gender and PA between groups: Conclusion: the significant differences in pitch's amplitude between PD patients and healthy individuals demonstrate the methods specificity.-The results showed the need of prospective controlled studies,to improve the use and indications of residual signal auto-correlation to evaluate speech in PD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field trial measurements are used to validate the level crossing rate formula derived in an exact manner recently for the Nakagami-m signal. The formula reveals an excellent fit to measurements in situations other than those for which the Rice model is more appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grinding is a finishing process in machining operations, and the topology of the grinding tool is responsible for producing the desired result on the surface of the machined material The tool topology is modeled in the dressing process and precision is therefore extremely important This study presents a solution in the monitoring of the dressing process, using a digital signal processor (DSP) operating in real time to detect the optimal dressing moment To confirm the monitoring efficiency by DSP, the results were compared with those of a data acquisition system (DAQ) and offline processing The method employed here consisted of analyzing the acoustic emission and electrical power signal by applying the DPO and DPKS parameters The analysis of the results allowed us to conclude that the application of the DPO and DPKS parameters can be substituted by processing of the mean acoustic emission signal, thus reducing the computational effort

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, minimum and non-minimum delay perfect codes were proposed for any channel of dimension n. Their construction appears in the literature as a subset of cyclic division algebras over Q(zeta(3)) only for the dimension n = 2(s)n(1), where s is an element of {0,1}, n(1) is odd and the signal constellations are isomorphic to Z[zeta(3)](n) In this work, we propose an innovative methodology to extend the construction of minimum and non-minimum delay perfect codes as a subset of cyclic division algebras over Q(zeta(3)), where the signal constellations are isomorphic to the hexagonal A(2)(n)-rotated lattice, for any channel of any dimension n such that gcd(n,3) = 1. (C) 2012 The Franklin Institute. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to assess the effect of the use of high-heeled shoes on static balance in young adult women. Fifty-three women between 18 and 30 years of age and accustomed to wearing high-heeled shoes participated in the study. None of the participants had any orthopedic or neurologic alterations. Static balance was assessed using a force plate. Oscillations from the center of pressure in the mediolateral and anteroposterior directions were measured both when barefoot and when wearing high-heeled shoes [7 centimeters (cm) in height and 1 cm in diameter] under the conditions of eyes open and eyes closed. Two-way analysis of variance was employed for the statistical analysis, with the level of significance set at 5% (p < .05). The results revealed statistically significant differences between tests when barefoot and when wearing high-heeled shoes as well as with eyes open and eyes closed (p < .01). With the use of high-heeled shoes, there was a significant increase in mediolateral oscillation with eyes closed (p < .01). The present study demonstrates that the use of seven-cm high heels altered static balance in the healthy young women analyzed, increasing the oscillation of the center of pressure, regardless of visual restriction. (C) 2012 Elsevier B.V. All rights reserved.