707 resultados para Quality of life questionnaire


Relevância:

100.00% 100.00%

Publicador:

Resumo:

How can we measure ‘quality of life’? The sustainable refurbishment goes beyond strictly energy aspects. Sustainability indicators are needed to facilitate data collection and to provide information which does not require too time-consuming calculations. Thus, you can offer an idea of the extent and quality of the rehabilitation before starting the project and, also, the obtained results can be evaluated in an agile way after the refurbishment. From a list of social indicators gathered from different methods, sustainability assessment tools and International and European standards, three social indicators are proposed: Users Satisfaction, Participation Agreement and Quality of Life. This paper shows the development of Quality of Life social indicator, the more closely related to the main objectives of Researchand Development Project “Sustainable Refurbishment”: improving energy efficiency and wellbeing of users in existing residential buildings. Finally, this social indicator is applied to a real case study in Málaga (Spain).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate whether for patients with incurable cancer comprehensive home care programmes are more effective than standard care in maintaining the patients’ quality of life and reducing their “readmission time” (percentage of days spent in hospital from start of care till death).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poster submitted to the 22nd International Conference Stress and Anxiety Research Society (STAR), Palma de Mallorca, July, 12-14, 2001.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To examine a single-optic accommodating intraocular lens (IOL) visual performance by correlating IOL implanted eyes’ defocus curve with the intraocular aberrometric profile and the impact on the quality of life (QOL). Methods: Prospective consecutive case series study including a total of 25 eyes of 14 patients with ages ranging between 52 and 79 years old. All cases underwent cataract surgery with implantation of the single-optic accommodating IOL Crystalens HD (Bausch & Lomb). Distance and near visual acuity outcomes, intraocular aberrations, the defocus curve and QOL (NEI VFQ-25) were evaluated 3 months after surgery. Results: A significant improvement in distance visual acuity was found postoperatively (p = 0.02). Mean postoperative LogMAR uncorrected near visual acuity was 0.44 ± 0.23 (20/30). 60% of eyes had a postoperative addition between 0 and 1.5 diopters (D). The defocus curve showed an area of maximum visual acuity for the levels of defocus corresponding to distance and intermediate vision (−1 to +0.5 D). Postoperative intermediate visual acuity correlated significantly some QOL indices (r ≥ 0.51, p ≤ 0.03; difficulty in going down steps or seeing how people react to things that patient says) as well as with J0 component of manifest cylinder. Postoperative distance-corrected near visual acuity correlated significantly with age (r = 0.65, p < 0.01). Conclusions: This accommodating IOL seems to be able to restore the distance visual function as well as to provide an improvement in intermediate and near vision with a significant impact on patient's QOL, although limited by age and astigmatism. Future studies with larger sample sizes should confirm all these trends.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.