962 resultados para Lower cost
Resumo:
Soil vapor extraction (SVE) is an efficient, well-known and widely applied soil remediation technology. However, under certain conditions it cannot achieve the defined cleanup goals, requiring further treatment, for example, through bioremediation (BR). The sequential application of these technologies is presented as a valid option but is not yet entirely studied. This work presents the study of the remediation of ethylbenzene (EB)-contaminated soils, with different soil water and natural organic matter (NOMC) contents, using sequential SVE and BR. The obtained results allow the conclusion that: (1) SVE was sufficient to reach the cleanup goals in 63% of the experiments (all the soils with NOMC below 4%), (2) higher NOMCs led to longer SVE remediation times, (3) BR showed to be a possible and cost-effective option when EB concentrations were lower than 335 mg kgsoil −1, and (4) concentrations of EB above 438 mg kgsoil −1 showed to be inhibitory for microbial activity.
Resumo:
Copyright © 2014 Entomological Society of America.
Resumo:
Mestrado em Engenharia Química
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
O objectivo desta tese é dimensionar um secador em leito fluidizado para secagem de cereais, nomeadamente, secagem de sementes de trigo. Inicialmente determinaram-se as condições de hidrodinâmica (velocidade de fluidização, TDH, condições mínimas de “slugging”, expansão do leito, dimensionamento do distribuidor e queda de pressão). Com as condições de hidrodinâmica definidas, foi possível estimar as dimensões físicas do secador. Neste ponto, foram realizados estudos relativamente à cinética da secagem e à própria secagem. Foi também estudado o transporte pneumático das sementes. Deste modo, determinaram-se as velocidades necessárias ao transporte pneumático e respectivas quedas de pressão. Por fim, foi realizada uma análise custos para que se soubesse o custo deste sistema de secagem. O estudo da secagem foi feito para uma temperatura de operação de 50ºC, tendo a ressalva que no limite se poderia trabalhar com 60ºC. A velocidade de operação é de 2,43 m/s, a altura do leito fixo é de 0,4 m, a qual sofre uma expansão durante a fluidização, assumindo o valor de 0,79 m. O valor do TDH obtido foi de 1,97 m, que somado à expansão do leito permite obter uma altura total da coluna de 2,76 m. A altura do leito fixo permite retirar o valor do diâmetro que é de 0,52 m. Verifica-se que a altura do leito expandido é inferior à altura mínima de “slugging” (1,20 m), no entanto, a velocidade de operação é superior à velocidade mínima de “slugging” (1,13 m/s). Como só uma das condições mínimas é cumprida, existe a possibilidade da ocorrência de “slugging”. Finalmente, foi necessário dimensionar o distribuidor, que com o diâmetro de orifício de 3 mm, valor inferior ao da partícula (3,48 mm), permite a distruibuição do fluido de secagem na coluna através dos seus 3061 orifícios. O inicio do estudo da secagem centrou-se na determinação do tempo de secagem. Além das duas temperaturas atrás referidas, foram igualmente consideradas duas humidades iniciais para os cereais (21,33% e 18,91%). Temperaturas superiores traduzem-se em tempos de secagem inferiores, paralelamente, teores de humidade inicial inferiores indicam tempos menores. Para a temperatura de 50ºC, os tempos de secagem assumiram os valores de 2,8 horas para a 21,33% de humidade e 2,7 horas para 18,91% de humidade. Foram também tidas em conta três alturas do ano para a captação do ar de secagem, Verão e Inverno representando os extremos, e a Meia- Estação. Para estes três casos, foi possível verificar que a humidade específica do ar não apresenta alterações significativas entre a entrada no secador e a corrente de saída do mesmo equipamento, do mesmo modo que a temperatura de saída pouco difere da de entrada. Este desvio de cerca de 1% para as humidades e para as temperaturas é explicado pela ausência de humidade externa nas sementes e na pouca quantidade de humidade interna. Desta forma, estes desvios de 1% permitem a utilização de uma razão de reciclagem na ordem dos 100% sem que o comportamento da secagem se altere significativamente. O uso de 100% de reciclagem permite uma poupança energética de cerca de 98% no Inverno e na Meia-Estação e de cerca de 93% no Verão. Caso não fosse realizada reciclagem, seria necessário fornecer à corrente de ar cerca de 18,81 kW para elevar a sua temperatura de 20ºC para 50ºC (Meia-Estação), cerca de 24,67 kW para elevar a sua temperatura de 10ºC para 50ºC (Inverno) e na ordem dos 8,90 kW para elevar a sua temperatura dos 35ºC para 50ºC (Verão). No caso do transporte pneumático, existem duas linhas, uma horizontal e uma vertical, logo foi necessário estimar o valor da velocidade das partículas para estes dois casos. Na linha vertical, a velocidade da partícula é cerca de 25,03 m/s e cerca de 35,95 m/s na linha horizontal. O menor valor para a linha vertical prende-se com o facto de nesta zona ter que se vencer a força gravítica. Em ambos os circuitos a velocidade do fluido é cerca de 47,17 m/s. No interior da coluna, a velocidade do fluido tem o valor de 10,90 m/s e a velocidade das partículas é de 1,04 m/s. A queda de pressão total no sistema é cerca de 2408 Pa. A análise de custos ao sistema de secagem indicou que este sistema irá acarretar um custo total (fabrico mais transporte) de cerca de 153035€. Este sistema necessita de electricidade para funcionar, e esta irá acarretar um custo anual de cerca de 7951,4€. Embora este sistema de secagem apresente a possibilidade de se realizar uma razão de reciclagem na ordem dos 100% e também seja possível adaptar o mesmo para diferentes tipos de cereais, e até outros tipos de materiais, desde que possam ser fluidizados, o seu custo impede que a realização deste investimento não seja atractiva, especialmente tendo em consideração que se trata de uma instalação à escala piloto com uma capacidade de 45 kgs.
Resumo:
Para dar resposta aos grandes avanços tecnológicos e, consequentemente, à postura mais exigente dos clientes, a empresa Francisco Parracho – Electrónica Industrial, Lda., que tem actividade no ramo dos elevadores, decidiu introduzir no mercado um controlador dedicado de ecrãs Liquid Crystal Display / Thin Film Transistor (LCD / TFT). O objectivo é substituir um sistema suportado por um computador, caracterizado pelas suas elevadas dimensões e custos, mas incontornável até à data, nomeadamente para resoluções de ecrã elevadas. E assim nasceu este trabalho. Com uma selecção criteriosa de todos os componentes e, principalmente, sem funcionalidades inúteis, obteve-se um sistema embebido com dimensões e custos bem mais reduzidos face ao seu opositor. O ecrã apontado para este projecto é um Thin Film Transistor – Liquid Crystal Display (TFT-LCD) da Sharp de 10.4” de qualidade industrial, com uma resolução de 800 x 600 píxeis a 18 bits por píxel. Para tal, foi escolhido um micro-controlador da ATMEL, um AVR de 32 bits que, entre outras características, possui um controlador LCD que suporta resoluções até 2048 x 2048 píxeis, de 1 a 24 bits por píxel. Atendendo ao facto deste produto ser inserido na área dos elevadores, as funcionalidades, quer a nível do hardware quer a nível do software, foram projectadas para este âmbito. Contudo, o conceito aqui exposto é adjacente a quaisquer outras áreas onde este produto se possa aplicar, até porque o software está feito para se tornar bem flexível. Com a ajuda de um kit de desenvolvimento, foram validados os drivers dos controladores e periféricos base deste projecto. De seguida, aplicou-se esse software numa placa de circuito impresso, elaborada no âmbito deste trabalho, para que fossem cumpridos todos os requisitos requeridos pela empresa patrocinadora: - Apresentação de imagens no ecrã consoante o piso; - Possibilidade de ter um texto horizontalmente deslizante;Indicação animada do sentido do elevador; - Representação do piso com deslizamento vertical; - Descrição sumária do directório de pisos também com deslizamento vertical; - Relógio digital; - Leitura dos conteúdos pretendidos através de um cartão SD/MMC; - Possibilidade de actualização dos conteúdos via USB flash drive.
Resumo:
In this paper we consider a differentiated Stackelberg model, when the leader firm engages in an R&D process that gives an endogenous cost-reducing innovation. The aim is to study the licensing of the cost-reduction by a two-part tariff. By using comparative static analysis, we conclude that the degree of the differentiation of the goods plays an important role in the results. We also do a direct comparison between our model and Cournot duopoly model.
Resumo:
Wireless Sensor Networks (WSNs) have been attracting increasing interests in the development of a new generation of embedded systems with great potential for many applications such as surveillance, environment monitoring, emergency medical response and home automation. However, the communication paradigms in Wireless Sensor Networks differ from the ones attributed to traditional wireless networks, triggering the need for new communication protocols and mechanisms. In this Technical Report, we present a survey on communication protocols for WSNs with a particular emphasis on the lower protocol layers. We give a particular focus to the MAC (Medium Access Control) sub-layer, since it has a prominent influence on some relevant requirements that must be satisfied by WSN protocols, such as energy consumption, time performance and scalability. We overview some relevant MAC protocol solutions and discuss how they tackle the trade-off between the referred requirements.
Resumo:
OBJECTIVE: To compare inpatient and outpatient care costs for pregnant/parturient women with diabetes and mild hyperglycemia. METHODS: A prospective observational quantitative study was conducted in the Perinatal Diabetes Center in the city of Botucatu, Southeastern Brazil, between 2007 and 2008. Direct and indirect costs and disease-specific costs (medications and tests) were estimated. Thirty diet-treated pregnant women with diabetes were followed up on an outpatient basis, and 20 who required insulin therapy were hospitalized. RESULTS: The cost of diabetes disease (prenatal and delivery care) was US$ 3,311.84 for inpatients and US$ 1,366.04 for outpatients. CONCLUSIONS: Direct and indirect costs as well as total prenatal care cost were higher for diabetic inpatients while delivery care costs and delivery-postpartum hospitalization were similar. Prenatal and delivery-postpartum care costs were higher for these patients compared to those paid by Brazilian National Health System.
Resumo:
While the earliest deadline first algorithm is known to be optimal as a uniprocessor scheduling policy, the implementation comes at a cost in terms of complexity. Fixed taskpriority algorithms on the other hand have lower complexity but higher likelihood of task sets being declared unschedulable, when compared to earliest deadline first (EDF). Various attempts have been undertaken to increase the chances of proving a task set schedulable with similar low complexity. In some cases, this was achieved by modifying applications to limit preemptions, at the cost of flexibility. In this work, we explore several variants of a concept to limit interference by locking down the ready queue at certain instances. The aim is to increase the prospects of schedulability of a given task system, without compromising on complexity or flexibility, when compared to the regular fixed task-priority algorithm. As a final contribution, a new preemption threshold assignment algorithm is provided which is less complex and more straightforward than the previous method available in the literature.
Resumo:
Replication is a proven concept for increasing the availability of distributed systems. However, actively replicating every software component in distributed embedded systems may not be a feasible approach. Not only the available resources are often limited, but also the imposed overhead could significantly degrade the system's performance. The paper proposes heuristics to dynamically determine which components to replicate based on their significance to the system as a whole, its consequent number of passive replicas, and where to place those replicas in the network. The results show that the proposed heuristics achieve a reasonably higher system's availability than static offline decisions when lower replication ratios are imposed due to resource or cost limitations. The paper introduces a novel approach to coordinate the activation of passive replicas in interdependent distributed environments. The proposed distributed coordination model reduces the complexity of the needed interactions among nodes and is faster to converge to a globally acceptable solution than a traditional centralised approach.
Resumo:
The foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represent significant diagnostic challenges. SPECT/CT Image fusion can provide missing anatomical and bone structure information to functional imaging, which is particularly useful to increase diagnosis certainty of bone pathology. However, due to SPECT acquisition duration, patient’s involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We aimed at designing an ankle and foot immobilizing device and measuring its efficacy at improving image fusion. Methods: We enrolled 20 patients undergoing distal lower-limb SPECT/CT of the ankle and the foot with and without a foot holder. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomical landmarks also visible on bone scintigraphy. Analysis of variance was performed for statistical analysis. Results: The obtained absolute average difference without and with support was 5.1±5.2 mm (mean±SD) and 3.1±2.7 mm, respectively, which is significant (p<0.001). Conclusion: The introduction of the foot holder significantly decreases misalignment between SPECT and CT images, which may have clinical influence in the precise localization of foot and ankle pathology.
Resumo:
OBJECTIVE To analyze the association between negative self-rated health and indicators of health, wellbeing and sociodemographic variables in older adults. METHODS Cross-sectional study that used data from a population-based health survey with a probability cluster sample that was carried out in Campinas, SP, Southeastern Brazil,, in 2008 and 2009. The participants were older adults (≥ 60 years) and the dependent variable was self-rated health, categorized as: excellent, very good, good, bad and very bad. The adjusted prevalence ratios were estimated by means of Poisson multiple regression. RESULTS The highest prevalences of bad/very bad self-rated health were observed in the individuals who never attended school, in those with lower level of schooling, with monthly per capita family income lower than one minimum salary. Individuals who scored five or more in the physical health indicator also had bad self-rated health, as well as those who scored five or more in the Self-Reporting Questionnaire 20 and those who did not refer feeling happiness all the time. CONCLUSIONS The independent effects of material life conditions, physical and mental health and subjective wellbeing, observed in self-rated health, suggest that older adults can benefit by health policies supported by a global and integrative view of old age.
Resumo:
This paper presents a novel approach to WLAN propagation models for use in indoor localization. The major goal of this work is to eliminate the need for in situ data collection to generate the Fingerprinting map, instead, it is generated by using analytical propagation models such as: COST Multi-Wall, COST 231 average wall and Motley- Keenan. As Location Estimation Algorithms kNN (K-Nearest Neighbour) and WkNN (Weighted K-Nearest Neighbour) were used to determine the accuracy of the proposed technique. This work is based on analytical and measurement tools to determine which path loss propagation models are better for location estimation applications, based on Receive Signal Strength Indicator (RSSI).This study presents different proposals for choosing the most appropriate values for the models parameters, like obstacles attenuation and coefficients. Some adjustments to these models, particularly to Motley-Keenan, considering the thickness of walls, are proposed. The best found solution is based on the adjusted Motley-Keenan and COST models that allows to obtain the propagation loss estimation for several environments.Results obtained from two testing scenarios showed the reliability of the adjustments, providing smaller errors in the measured values values in comparison with the predicted values.
Resumo:
OBJECTIVE To analyze the cost-effectiveness of treatment regimens with cyclosporine or tacrolimus, five years after renal transplantation.METHODS This cost-effectiveness analysis was based on historical cohort data obtained between 2000 and 2004 and involved 2,022 patients treated with cyclosporine or tacrolimus, matched 1:1 for gender, age, and type and year of transplantation. Graft survival and the direct costs of medical care obtained from the National Health System (SUS) databases were used as outcome results.RESULTS Most of the patients were women, with a mean age of 36.6 years. The most frequent diagnosis of chronic renal failure was glomerulonephritis/nephritis (27.7%). In five years, the tacrolimus group had an average life expectancy gain of 3.96 years at an annual cost of R$78,360.57 compared with the cyclosporine group with a gain of 4.05 years and an annual cost of R$61,350.44.CONCLUSIONS After matching, the study indicated better survival of patients treated with regimens using tacrolimus. However, regimens containing cyclosporine were more cost-effective.