866 resultados para INTERTROCHANTERIC HIP-FRACTURES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The carbonate outcrops of the anticline of Monte Conero (Italy) were studied in order to characterize the geometry of the fractures and to establish their influence on the petrophysical properties (hydraulic conductivity) and on the vulnerability to pollution. The outcrops form an analog for a fractured aquifer and belong to the Maiolica Fm. and the Scaglia Rossa Fm. The geometrical properties of fractures such as orientation, length, spacing and aperture were collected and statistically analyzed. Five types of mechanical fractures were observed: veins, joints, stylolites, breccias and faults. The types of fractures are arranged in different sets and geometric assemblages which form fracture networks. In addition, the fractures were analyzed at the microscale using thin sections. The fracture age-relationships resulted similar to those observed at the outcrop scale, indicating that at least three geological episodes have occurred in Monte Conero. A conceptual model for fault development was based on the observations of veins and stylolites. The fracture sets were modelled by the code FracSim3D to generate fracture network models. The permeability of a breccia zone was estimated at microscale by and point counting and binary image methods, whereas at the outcrop scale with Oda’s method. Microstructure analysis revealed that only faults and breccias are potential pathways for fluid flow since all veins observed are filled with calcite. According this, three scenarios were designed to asses the vulnerability to pollution of the analogue aquifer: the first scenario considers the Monte Conero without fractures, second scenario with all observed systematic fractures and the third scenario with open veins, joints and faults/breccias. The fractures influence the carbonate aquifer by increasing its porosity and hydraulic conductivity. The vulnerability to pollution depends also on the presence of karst zones, detric zones and the material of the vadose zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thrust fault-related folds in carbonate rocks are characterized by deformation accommodated by different structures, such as joints, faults, pressure solution seams, and deformation bands. Defining the development of fracture systems related to the folding process is significant both for theoretical and practical purposes. Fracture systems are useful constrains in order to understand the kinematical evolution of the fold. Furthermore, understanding the relationships between folding and fracturing provides a noteworthy contribution for reconstructing the geodynamic and the structural evolution of the studied area. Moreover, as fold-related fractures influence fluid flow through rocks, fracture systems are relevant for energy production (geothermal studies, methane and CO2 , storage and hydrocarbon exploration), environmental and social issues (pollutant distribution, aquifer characterization). The PhD project shows results of a study carried out in a multilayer carbonate anticline characterized by different mechanical properties. The aim of this study is to understand the factors which influence the fracture formation and to define their temporal sequence during the folding process. The studied are is located in the Cingoli anticline (Northern Apennines), which is characterized by a pelagic multilayer characterized by sequences with different mechanical stratigraphies. A multi-scale analysis has been made in several outcrops located in different structural positions. This project shows that the conceptual sketches proposed in literature and the strain distribution models outline well the geometrical orientation of most of the set of fractures observed in the Cingoli anticline. On the other hand, the present work suggests the relevance of the mechanical stratigraphy in particular controlling the type of fractures formed (e.g. pressure solution seams, joints or shear fractures) and their subsequent evolution. Through a multi-scale analysis, and on the basis of the temporal relationship between fracture sets and their orientation respect layering, I also suggest a conceptual model for fracture systems formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Open fractures of the leg represent a severe trauma. The combined approach, shared between plastic and orthopaedic surgeons, is considered to be important, although this multidisciplinary treatment is not routinely performed. Aim of this study was to verify whether the orthoplastic treatment is of any advantage over the traditional simply orthopedic treatment, through a multicentric inclusion of these unfrequent injuries into a prospective study. Material and methods: The following trauma centres were involved: Rizzoli Orthopaedic Institute/University of Bologna (leading centre) and Maggiore Hospital (Bologna, Italy), Frenchay Hospital (Bristol, United Kingdom), Jinnah Hospital (Lahore, Pakistan). All patients consecutively hospitalized in the mentioned centres between January 2012 and December 2013 due to tibial open fractures were included in the study and prospectively followed up to December 2014. Demographics and other clinical features were recorded, including the type of treatment (orthopaedic or orthoplastic). The considered outcome measures included duration of hospitalization, time for bone union and soft tissue closure, Enneking score at 3, 6 and 12 months, the incidence of osteomyelitis and other complications. Results: A total of 164 patients were included in the study. Out of them 68% were treated with an orthoplastic approach, whereas 32% received a purely orthopedic treatment. All considered outcome measures showed to be improved by the orthoplastic approach, compared to the orthopaedic one: time for soft tissue closure (2 versus 25 weeks), duration of hospital stay (22 versus 55 days), time for bone union (6 versus 8.5 months) , number of additional operations (0.6 versus 1.2) and functional recovery of the limb at 12 months (27 versus 19, Enneking’s score). All results were statistically significant. Conclusion: The combined orthoplastic approach to the treatment of open tibia fractures, in particular for high grade injuries (Gustilo 3B), is proven to improve the outcome of these severe injuries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’accoppiamento articolare in ceramica è sempre più utilizzato in chirurgia protesica dell’anca per le sue eccellenti proprietà tribologiche. Tuttavia la fragilità della ceramica è causa di fallimenti meccanici. Abbiamo quindi condotto una serie di studi al fine di individuare un metodo efficace di diagnosi precoce del fallimento della ceramica. Abbiamo analizzato delle componenti ceramiche espiantate e abbiamo trovato un pattern di usura pre-frattura che faceva supporre una dispersione di particelle di ceramica nello spazio articolare. Per la diagnosi precoce abbiamo validato una metodica basata sulla microanalisi del liquido sinoviale. Per validare la metodica abbiamo eseguito un agoaspirato in 12 protesi ben funzionanti (bianchi) e confrontato i risultati di 39 protesi con segni di rottura con quelli di 7 senza segni di rottura. Per individuare i pazienti a rischio rottura i dati demografici di 26 pazienti con ceramica rotta sono stati confrontati con 49 controlli comparabili in termini demografici, tipo di ceramica e tipo di protesi. Infine è stata condotta una revisione sistematica della letteratura sulla diagnosi della rottura della ceramica. Nell’aspirato la presenza di almeno 11 particelle ceramiche di dimensioni inferiori a 3 micron o di una maggiore di 3 micron per ogni campo di osservazione sono segno di rottura della ceramica. La metodica con agoaspirato ha 100% di sensibilità e 88 % di specificità nel predire rotture della ceramica. Nel gruppo delle ceramiche rotte è stato trovato un maggior numero di malposizionamenti della protesi rispetto ai controlli (p=0,001). Il rumore in protesi con ceramica dovrebbe sollevare il sospetto di fallimento ed indurre ad eseguire una TC e un agoaspirato. Dal confronto con la letteratura la nostra metodica risulta essere la più efficace.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'elaborato prende in esame i fattori che hanno portato allo sviluppo del rap e dell'hip-hop in Russia, prendendo in esame i principali esponenti del genere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays the number of hip joints arthroplasty operations continues to increase because the elderly population is growing. Moreover, the global life expectancy is increasing and people adopt a more active way of life. For this reasons, the demand of implant revision operations is becoming more frequent. The operation procedure includes the surgical removal of the old implant and its substitution with a new one. Every time a new implant is inserted, it generates an alteration in the internal femur strain distribution, jeopardizing the remodeling process with the possibility of bone tissue loss. This is of major concern, particularly in the proximal Gruen zones, which are considered critical for implant stability and longevity. Today, different implant designs exist in the market; however there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. The aim of the study is to investigate the stress shielding effect generated by different implant design parameters on proximal femur, evaluating which ranges of those parameters lead to the most physiological conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of the language used in Beyoncé's song "***Flawless" and its thematics, including feminism, womanism, and the world of hip-hop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un'analisi cronologica della situazione politica e sociale della comunità Afroamericana negli Stati Uniti e di come questa abbia influenzato la nascita e lo sviluppo dell'hip hop come manifestazione culturale

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The revision hip arthroplasty is a surgical procedure, consisting in the reconstruction of the hip joint through the replacement of the damaged hip prosthesis. Several factors may give raise to the failure of the artificial device: aseptic loosening, infection and dislocation represent the principal causes of failure worldwide. The main effect is the raise of bone defects in the region closest to the prosthesis that weaken the bone structure for the biological fixation of the new artificial hip. For this reason bone reconstruction is necessary before the surgical revision operation. This work is born by the necessity to test the effects of bone reconstruction due to particular bone defects in the acetabulum, after the hip prosthesis revision. In order to perform biomechanical in vitro tests on hip prosthesis implanted in human pelvis or hemipelvis a practical definition of a reference frame for these kind of bone specimens is required. The aim of the current study is to create a repeatable protocol to align hemipelvic samples in the testing machine, that relies on a reference system based on anatomical landmarks on the human pelvis. In chapter 1 a general overview of the human pelvic bone is presented: anatomy, bone structure, loads and the principal devices for hip joint replacement. The purpose of chapters 2 is to identify the most common causes of the revision hip arthroplasty, analysing data from the most reliable orthopaedic registries in the world. Chapter 3 presents an overview of the most used classifications for acetabular bone defects and fractures and the most common techniques for acetabular and bone reconstruction. After a critical review of the scientific literature about reference frames for human pelvis, in chapter 4, the definition of a new reference frame is proposed. Based on this reference frame, the alignment protocol for the human hemipelvis is presented as well as the statistical analysis that confirm the good repeatability of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the performance of a newly developed examination chair as compared with the clinical standard of assessing internal rotation (IR) of the flexed hip with a goniometer. METHODS: The examination chair allowed measurement of IR in a sitting position simultaneously in both hips, with hips and knees flexed 90 degrees, lower legs hanging unsupported and a standardized load of 5 kg applied to both ankles using a bilateral pulley system. Clinical assessment of IR was performed in supine position with hips and knees flexed 90 degrees using a goniometer. Within the framework of a population-based inception cohort study, we calculated inter-observer agreement in two samples of 84 and 64 consecutive, unselected young asymptomatic males using intra-class correlation coefficients (ICC) and determined the correlation between IR assessed with examination chair and clinical assessment. RESULTS: Inter-observer agreement was excellent for the examination chair (ICC right hip, 0.92, 95% confidence interval [CI] 0.89-0.95; ICC left hip, 0.90, 95% CI 0.86-0.94), and considerably higher than that seen with clinical assessment (ICC right hip, 0.65, 95% CI 0.49-0.77; ICC left hip, 0.69, 95% CI 0.54-0.80, P for difference in ICC between examination chair and clinical assessment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A classification of injuries is necessary in order to develop a common language for treatment indications and outcomes. Several classification systems have been proposed, the most frequently used is the Denis classification. The problem of this classification system is that it is based on an assumption, which is anatomically unidentifiable: the so-called middle column. For this reason, few years ago, a group of spine surgeons has developed a new classification system, which is based on the severity of the injury. The severity is defined by the pathomorphological findings, the prognosis in terms of healing and potential of neurological damage. This classification is based on three major groups: A = isolated anterior column injuries by axial compression, B = disruption of the posterior ligament complex by distraction posteriorly, and group C = corresponding to group B but with rotation. There is an increasing severity from A to C, and within each group, the severity usually increases within the subgroups from .1, .2, .3. All these pathomorphologies are supported by a mechanism of injury, which is responsible for the extent of the injury. The type of injury with its groups and subgroups is able to suggest the treatment modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this retrospective study was to clarify the occurrence and types of dental injuries in 389 patients who had been diagnosed with facial fractures, and to analyze whether the occurrence of dental injury correlates to gender, age, trauma mechanism and type of facial fracture. Dental injuries were observed in 62 patients (16%). The most common type of injury was a crown fracture (48%). Dental injuries were multiple in most patients (63%). Almost half (48%) of all injured teeth were severely injured. Most injured teeth (61%) were in the maxilla. The incisor region was the most prevalent site in both the mandible (45%) and the maxilla (56%). The occurrence of dental injury correlated significantly with trauma mechanism and fracture type: motor vehicle accidents and mandibular fracture were significant predictors for dental trauma. The notable rate of dental injury observed in the present study emphasizes the importance of a thorough examination of the oral cavity in all patients who have sustained facial fracture. Referral to a dental practice for further treatment and follow up as soon as possible after discharge from hospital is fundamental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To identify the rates and reasons for plate removal (PR) among patients treated for facial fractures. MATERIALS AND METHODS: A retrospective review of files of 238 patients. RESULTS: Forty-eight patients (20.2%) had plates removed. The reason for removal was objective in 33.3% and subjective in 29.2%. The most common subjective reason was cold sensitivity, and the most common objective reason was wound dehiscence/infection. Women had PR for subjective reasons more often than men (p=0.018). Removal was performed more often for subjective reasons after zygomatico-orbital fractures than after mandibular fractures (p=0.002). Plates inserted in the mandible from an intraoral approach were removed more frequently than extraorally inserted mandibular plates, intraorally inserted maxillary plates, and extraorally inserted plates in other locations (p<0.001). Orbital rim plates had a higher risk of being removed than maxillary or frontal bone plates (p=0.02). CONCLUSIONS: Subjective discomfort is a notable reason for PR among Finnish patients, suggesting that the cold climate has an influence on the need for removal. Patients receiving mandibular osteosynthesis with miniplates from an intraoral approach are at risk of hardware removal because of wound dehiscence/infection and loose/broken hardware, reminding us that more rigid fixation devices should not be forgotten despite the widespread use of miniplates.