997 resultados para Excited ions
Resumo:
Knowing that Fe is sensitive to swift heavy ion irradiations whereas Au and Al are not, the behavior of nanometric metallic multilayer systems, like [Fe(3 nm)/Au(x)](y) and [Fe(3 nm)/Al(x)](y) with x ranging between 1 and 10 mn, were studied within the inelastic thermal spike model. In addition to the usual cylindrical geometry of energy dissipation perpendicular to the ion projectile direction, the heat transport along the ion path was implemented in the electronic and atomic sub-systems. The simulations were performed using three different values of linear energy transfer corresponding to 3 MeV/u of Pb-208, Xe-132 and Kr-84 ions. For the Fe/Au system, evidence of appearance of a molten phase was found in the entire Au layer, provided the Au thickness is less than 7 nm and 3 nm for Pb and Xe ions, respectively. For the Fe/Al(x) system irradiated with Pb ions, the Al layers with a thickness less than 4 nm melt along the entire ion track. Surprisingly, the Fe layer does not melt if the Al thickness is larger than 2 nm, although the deposited energy surpasses the electronic stopping power threshold of track formation in Fe. For Kr ions melting does not occur in any of the multilayer systems.
Resumo:
The main ion beams acceleration facilities and research fields of the Institute of Modern Physics (IMP) are briefly introduced. Some of the experimental instruments, typical works and the obtained results on the materials research with swift heavy ions at the IMP-accelerators are presented.
Resumo:
Hypersensitive response of mammalian cells in cell killing to X- and gamma-rays has been reported at doses below 1 Gy. The purpose of this study was to examine the low dose sensitivity of human hepatoma SMMC-7721 cells irradiated with Co-60 gamma-rays and 50 MeV/u C-12 ions. Experiments using gamma-rays and charged particle irradiation were performed, particularly in the low dose range from 0 to 2 Gy. The survival effect of SMMC-7721 cells was measured by means of standard clonogenic assay in conjunction with a cell sorter. The result indicates SMMC-7721 cells showed hyper-radiosensitive response at low doses and increased radio-resistance at larger single doses for the carbon ions (LET = 45.2 keV/mu m) and the gamma-rays. However, the HRS/IRR effect caused by high-LET irradiation is different from that by low-LET radiation. This might possibly be due to the difference in the mode of energy deposition by particle beam and low-LET irradiation.
Resumo:
Human hepatoma and normal liver cells were irradiated with C-12(6+), ion beams (LET= 96.05 keV/mu m) and gamma-rays at Heavy Ion Research Facility in Lanzhou (HIRFL). The chromatid breaks and break types were detected using the premature chromosome condensation technique. Our experimental results showed that chromatid breaks seem to have a good relation with C-12(6+) absorbed dose and C-12(6+) are more effective to induce chromatid breaks as compared to they-rays. For C-12(6+) ion irradiation the major break was isochromatid break, while chromatid breaks were dominant for gamma-ray irradiation. We also observed that the Relative Biology Effectiveness (RBE) of C-12(6+) ion is about 2.5 times higher than that of gamma-rays.
Resumo:
The electron emission induced by highly charged ions Pb-207(q+) (24 <= q <= 36) interacting with Si(110) surface is reported. The result shows that the electron emission yield Y has a strong dependence on the projectile charge state q, incidence angle psi and impact energy E. In fitting the experimental data we found a nearly 1/tan psi dependence of Y. Theoretical analysis shows that these processes are closely related to the process of potential electron emission based on the classical over-the-barrier model.
Resumo:
The cross-section ratios of double-, triple-, quadruple-, and the total multi-electron processes to the single electron capture process sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC)) as well as the relative ratios among reaction channels in double-electron active, triple-electron active and quadruple- electron active are measured in C-13(6+) -Ne collision in the energy region of 4.15-11.08 keV/u by employing position-sensitive and time-of-flight coincident techniques. It is determined that the cross-section ratios sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC) are approximately the constants of 0.20 +/- 0.03, 0.16 +/- 0.04, 0.06 +/- 0.02 and 0.42 +/- 0.05. These values are obviously smaller than the predictions of the molecular Coulomb over-the-barrier model (MCBM) [J. Phys. B 23 (1990) 4293], the extended classical over-the-barrier model (ECBM) [J. Phys. B 19 (1986) 2925] and the semiempirical scaling laws (SL) [Phys. Rev. A 54 (1996) 4127]. However, the relative ratios among partial processes of DE, TE and QE are found to depend on collision energy, which suggests that the collision dynamics depends on the collision velocity. The limitation of velocity-independent character of ECBM, MCBM and SL is undoubtedly shown.
Resumo:
The present study was performed to obtain evidence of the radioprotective function of melatonin at different administration levels on carbon ion-induced mouse testicular damage. Outbred Kun-Ming strain mice were divided into six groups, each composed of eight animals: control group, melatonin alone group, irradiation group and three melatonin plus irradiation-treated groups. An acute study was carried out to determine alterations in DNA-single strand break, cell apoptosis, and oxidative stress parameters as well as histopathology in mouse testis 24 h after whole-body irradiation with a single dose of 4 Gy Tie results showed that pre-treatment and post-treatment with high-dose melatonin (10 mg/kg) both significantly alleviated carbon ion-induced acute testicular damage, a greater radioprotective effect being observed in the pre-treatment group. On the other hand, low-dose melatonin (1 mg/kg) had a limited radioprotective effect on irradiation-induced degeneration and DNA lesions in mouse testis. Taken together, the data suggest that prophylactic treatment with a higher dose of melatonin is probably advisable to protect against the effects of heavy-ion irradiation.
Resumo:
The study is to investigate the feasibility and advantages of heavy ion beams on radiotherapy. The cellular cycle and apoptosis, cell reproductive death and p53 expression evaluated with flow cytometry, clonogenic survival assays and Western blot analysis were examined in lung carcinoma cells after exposure to 89.63 MeV/u carbon ion and 6 MV X-ray irradiations, respectively. The results showed that the number colonyforming assay of A549 was higher than that of H1299 cells in two radiation groups; A549 cellular cycle was arrested in G(2)/M in 12 It and the percentage of apoptosis ascended at each time point of carbon ion radiation with doses, the expression of p53 upregulated with doses exposed to X-ray or carbon ion. The cell number in G(2)/M of H1299 and apoptosis were increasing at all time points with doses in C-12(6+) ion irradiation group. The results suggested that the effects of carbon ions or X rays irradiation on lung carcinoma cells were different, C-12(6+) ion irradiation could have more effect on upregulating the expression of p53 than X-ray, and the upregulated expression of p53 might produce the cellular cycle G(2)/M arrested, apoptosis increasing; and p53 gene might affect the lung cancer cells radiosensitivity.
Resumo:
Spectra for Delta n = 0 transitions of the type 2s(2)2p(k)-2s2p(k+1) or 2s2p(k)-2p(k+1) from highly ionized sulfur produced in beam-foil excitation are investigated and compared to similar spectra measured with other types of light sources. In the experiment, fifty lines have been identified, of which eleven lines are new and accurately measured. Analysis of spectra was based on comparisons with other experimental results and calculated values.
Resumo:
The aim of this work is to identify if there is sex specificity on C-12(6+) ion-induced oxidative damage in mouse lung at different time points. Kun-Ming mice were divided into two groups, each composed of six males and six females: control group and irradiation group with a single acute dose of 4 Gy. Animals were sacrificed at 2, 4 and 12 h respectively, there lungs were removed immediately, and the oxidative stress-related biomarkers were measured by Diagnostic Reagent Kits. The results showed that the relative activities of superoxide dismutase (4 h), catalase (2 h) and Se-dependent glutathione peroxidase (12 h) have significant changes (P < 0.05) between male groups and female groups, suggesting that the lungs of male mice are more sensitive to counteracting the oxidative challenge. Moreover, higher levels of malondiadehyde and lower contents of glutathione were also found in males, indicating that oxidative stress induced by C-12(6+) ion is pronounced in the lungs of males. We thought that these sex-responded differences may be attributed to the influence of sex hormones.
Resumo:
The extraction of Am3+ and Eu3+ from picric acid aqueous solution by N,N-1,2-ethanediyl-bis[2-(N,N-diphenyl-carbamoyl-methoxy)-benzamide] was investigated by a radioactive tracer technique. The composition of the extracted species has been determined as ML(Pic)(3) (M = Eu, Am). The effect of various parameters such as pH, organic diluents, different extractants, picric acid concentration and extractants concentration on the extraction of Am3+ and Eu3+ has been studied. The extraction equilibrium mechanism has been also evaluated and discussed.
Resumo:
There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e mu A of O7+, 505 e mu A of Xe20+ 306 e mu A of Xe27+, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.
Resumo:
气体探测器有成本低廉、制备简单、性能可靠和方便使用等特点。研制了一种5层板结构的延迟线平行板雪崩电离室(PPAC),用于兰州放射性束流线(RIBLL)上开展的实验。在57.6MeV/u的6He束流条件下测试了这种探测器对高能轻粒子的适用性,得到了位置分辨为1.8mm(FWHM),时间分辨为2.6ns,以及可靠的探测效率。
Resumo:
比较了N-乙酰半胱氨酸(NAC)及乙酰左旋肉毒碱(ALCAR)对12C6+离子照射小鼠的损伤效应,并探讨了其可能的作用机制。利用4Gy剂量的12C6+离子束对预先给予NAC(100mg/kg)和ALCAR(100mg/kg)保护的昆明小鼠进行单次全身照射。随后检测肝组织中总抗氧化能力(TAC)、DNA单链断裂和细胞凋亡率。结果显示,与照射对照组相比,提前给予NAC和ALCAR均极显著地增强了肝组织的抗氧化能力(P<0.001),减轻了12C6+离子导致的肝组织中DNA断裂(P<0.001)和细胞凋亡(P<0.001)。此外,还发现ALCAR组抗重离子辐照损伤的能力显著地高于NAC组(P<0.05)。实验结果提示了NAC和ALCAR可通过抵御组织内的氧化胁迫,阻止DNA链的断裂和细胞的凋亡,实现对C离子辐照损伤的保护效应。而且ALCAR比NAC可能更适合成为有潜力、有希望的抗C重离子辐射药物。
Resumo:
介绍了储存环高精度分子谱学研究的科学意义、国内外研究现状和利用HIRFL-CSR开展该项研究的优势,着重论证了HIRFL-CSR分子离子注入实验环的总体设计方案和技术方案。通过在HIRFL-CSR实验环上增建一条分子离子注入线,将实验环改造成能兼顾现有物理实验和大分子物理研究的综合性研究平台,为分子离子复合离解研究提供良好的技术支撑。特别是质量数大于70的分子离子,能显著提高其能量分辨。