842 resultados para Electrode position
Resumo:
Improvement of the operational stability of amperometric sensors based on Prussian Blue (PB) modified glassy carbon electrodes is presented. The long term performance of the sensors was evaluated by injection of hydrogen peroxide (5 μM in potassium buffer) solutions in a flow-injection system during a period of 5-10 h. The following parameters were investigated and correlated with the performance of the sensor: the times for electrodeposition and electrochemical activation, temperature, storage time, pH, composition of the buffer solution and of volume sample injected. These analytical characteristics of the modified electrode can be emphasized: initial sensitivity of 0.3 A cm-2 M-1, detection limit of ca. 0.5 μM, precise results (r.s.d.< 1.5%) and possibility to carry out around 50 samples (50 μL) per hour.
Resumo:
Recently, piezoelectric cellular polypropylene (PP) was proposed as a new type of quasi-ferroelectric. The observed hysteresis of the charge density as a function of the electric field could be explained as field-dependent charging inside the gas-filled voids. Interestingly enough, the measurable poling behavior of the macroscopic dipoles formed by charges that are trapped at the internal void surfaces is phenomenologically completely identical to the cooperative poling behavior of microscopic molecular dipoles in ferroelectric polymers. Therefore, it can be assumed that charge separation (or charge redistribution) and subsequent trapping in cellular PP is a rather fast switching process. In order to examine the poling dynamics, we developed an experimental setup for pulsed poling. High-voltage pulses with a duration of 45 μs (FWHM) were applied in direct contact to two-side metallized cellular PP films. The pulsed poling yields piezoelectricity in the cellular PP. We study and discuss the dependence of the resulting piezoelectricity on the poling field. We also characterize the charge separation during application of higher electric poling fields of up to -10 kV in direct contact to the two-side metallized films for longer times.
Resumo:
The trapezius and serratus anterior muscles were studied in four modalities of rowing exercises executed with two grips, middle and closed, in comparison with the four different modalities of frontal-lateral cross, dumbbells exercise. It was used 24 male volunteers, 18 to 25 years old using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The results showed that TS acted in a higher significant way in all the modalities of rowing than in the supine lateral raise, inclined supine lateral raise and reverse supine lateral raise, dumbbells exercises, and demonstrated no standing frontal-lateral cross, dumbbells. The SI acted more significantly difference among all the execution modalities of rowing and the inclined supine lateral raise, dumbbells exercises than in all the rowing exercises; even though the activity levels do not make us suggest them as an excellent group of exercises for the development of this muscle.
Resumo:
Because the lack of textbooks based on electromyographic studies in the area of exercises for physical conditioning, the authors proposed to study the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles during the execution of four different modalities of rowing exercises with middle grip in 24 male volunteers, 18 to 25 years old. For the recordings, it was used a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the movements, a supine bench and a 120 cm-long bar made of low weight wood were used. The results showed that TS acted significantly in upright, sitting and inclined rowing, justifying its inclusion in physical conditioning programmes, while SI, in spite of acting preferentially in upright and sitting rowing, presented activity levels which do not justify its inclusion.
Resumo:
Because the lack of specialized textbooks on the select and indication of basic exercises for physical conditioning programmes, an electromyographic study of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with middle and closed grip in three different modalities, upright, sitting and bent over was performed. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a supine bench, a straight board and a 1,20 m-long bar made of light wood were used. The results showed that TS acted preferentially with closed grip sitting and bent over modalities, and presented no difference among the grips for upright rowing. SI acted preferentially with closed grip in all modalities, however, with activity levels that do not justify its indication for physical conditioning programmes.
Resumo:
The electromyographic activity of the shoulder muscles deltoid - anterior portion (DA) and pectoralis major - clavicular portion (PMC) was tested on 24 male volunteers using a 2 channel TEC A TE4 electromyograph and Hewlett Packard surface electrodes during the execution of four different modalities of frontal-lateral cross, dumbbells exercises. The results showed that all of the tested exercises developed high levels of action potential for both muscles. So, we jusfity the indication of all of them for physical fitness programmes for DA and PMC. Some suggestions to the use of the tested exercises are presented.
Resumo:
The muscles deltoid-anterior portion (DA) and pectoralis major-clavicular portion (PMC) were analysed to establish the muscular behavior and intensity patterns, as well to evaluate the connected participation of these muscles during supine and frontal elevation exercises. Twenty-four male volunteers were examined using a 2-channel TECA TE4 electromyograph and Hewlett Packard surface electrodes. Our results showed low levels of activity to PMC in frontal elevation exercises, whereas to DA the levels were very high. In the supine exercise, the action potential levels developed by the PMC were always lower than those presented by DA, however, with action simultaneity. Some suggestions to the use of the tested exercises are presented.
Resumo:
Iron nitroprusside Fe(II)NP was incorporated into a carbon paste electrode and the electrochemical studies were performed with cyclic voltammetry. The cyclic voltammogram of Fe(II)NP exhibits two redox couple with formal potential (E0')1 = 0.24 e (E0')2 = 0.85 V vs SCE attributed to Fe(II)/Fe(II) and Fe (II)(CN)5NO/Fe(III)(CN)5NO, respectively. The redox couple with (E0')2 = 0.85 V presents an electrocatalytic response for sulfhydryl compounds. The electrocatalytic oxidation of sulfhydryl compounds by the mediator has been used for the determination of L-cysteine and N-acetylcysteine. The modified graphite paste electrode gives a linear range from 9.2 x 10-4-2.0 x 10-2;; 9.6 x 10-4-1.4 x 10-2mol L-1 for the determination of L-cysteine and N-acetylcysteine, respectively, with detection limit of 1.9 x 10-4 mol L-1;; 1.5 x 10 -4 mol L-1 and relative standard desviations ± 5% and 1.5 x 10-3 mol L-1 ± 4% (n=3). The amperometric sensitivities are 0.024 and 0.027 μA/μmol L-1 for L-cysteine and N-acetylcysteine, respectively. The application of this electrode was tested and a commercial pharmaceutical product (Fluimucil) has been determined.
Resumo:
A flow-injection system with a glassy carbon disk electrode modified with Prussian Blue film is proposed for the determination of persulfate in commercial samples of hair bleaching boosters by amperometry. The detection was obtained by chronoamperometric technique and the sample is injected into the electrochemical cell in a wall jet configuration. Potassium chloride at concentration of 0.1 mol L-1 acted as sample carrier at a flow rate of 4.0 mL min-1 and supporting-electrolyte. For 0.025 V (vs. Ag/AgCl) applied voltage, the proposed system handles ca. 160 samples per hour (1.0 10-4 - 1.0 10-3 mol L-1 of persulfate), consuming about 200 μL sample and 11 mg KCl per determination. Typical linear correlations between electrocatalytic current and persulfate concentration was ca. 0.9998. The detection limit is 9.0 10-5 mol L-1 and the calculated amperometric sensibility 3.6 103 μA L mol -1. Relative standard deviation (n =12) of a 1.0 10-4 mol L-1 sample is about 2.2%. The method was applied to persulfate determination in commercial hair-bleaching samples and results are in agreement with those obtained by titrimetry at 95% confidence level and good recoveries (95 - 112%) of spiked samples were found. © 2003 by MDPI.
Resumo:
The electrochemistry reduction for the removal of Reactive Blue 4 (RB4) dye from aqueous solution using reticulated glassy carbon electrode is investigated. At pH < 8.0 the anthraquinone group of the RB4 dye are reduced in one cathodic step to hidroquinone after a reversible two-electron process involving a precedent two protons reaction. A stable semiquinone is detected by spectrophotometric technique. At pH > 8.0 the reduction process involves two reversible 2-electron steps, whose species are generated by a protonation equilibrium of anthraquinone group. The results shows that 60% of color removal was obtained after 3 hours of RB4 dye electrolysis at acidic and neutral conditions and only 37% at alkaline conditions. Simultaneously 64% of total organic carbon was removed after electrolysis at pH 2.0.
Resumo:
The preparation and electrochemical characterization of a carbon paste electrode modified with N.N′-ethylenebis(salicylideneiminato) oxovanadium(IV) complex ([VO(Salen)]) as well as its behavior as electrocatalyst toward the oxidation of dipyrone were investigated. The electrochemical behavior of the modified electrode and the electrooxidation of dipyrone were explored using cyclic voltammetry. The voltammetric response of the modified electrode is based on two reactions. One electrochemical related to the oxidation of the metallic center of the [VO(Salen)] and the other involving the chemical redox process involving the oxidized form of the complex and the reduced form of dipyrone. The best voltammetric response was observed for a paste composition of 25% (m/m) [VO(Salen)], KCl solution pH from 5.5 to 8.0 as the electrolyte and potential scan rate of 10 mV s-1 in the presence of dipyrone. A linear voltammetric response for dipyrone was obtained in the concentration range from 9.9 × 106 to 2.8 × 10 -3 mol L-1, with a detection limit of 7.2 × 10 -6 mol L-1. Among of several compounds tested as potential interference, only ascorbic acid presented some interference. The proposed electrode is useful for the quality control and routine analysis of dipyrone in pharmaceutical formulations.
Resumo:
In this work, electrochemical oxidation of albendazole (ABZ) was carried out using a glassy carbon-rotating disk electrode. Development of electroanalytical methodology for ABZ quantification in pharmaceutical formulations was also proposed by using linear sweep voltammetric technique. Electrochemical oxidation is observed for ABZ at E 1/2 = 0.99:V vs. Ag/AgCl sat, when an anodic wave is observed. Kinetic parameters obtained for ABZ oxidation exhibited a standard heterogeneous rate constant for the electrodic process equal to (1.51 ± 0.07) ± 10 -5:cm:s -1, with a αn a value equal to 0.76. Limiting current dependence against ABZ concentration exhibited linearity on 5.0 ± 10 -5 to 1.0 ± 10 -2:mol:l -1 range, being obtained a detection limit of 2.4 ± 10 -5:mol:l -1. Proposed methodology was applied to ABZ quantification in pharmaceutical formulations. © 2005 Elsevier SAS. All rights reserved.
Resumo:
A mercury-sensitive chemically modified graphite paste electrode was constructed by incorporating modified silica gel into a conventional graphite paste electrode. The functional group attached to the (3-chloropropyl) silica gel surface was 2-mercaptoimidazole, giving a new product denoted by 3-(2-thioimidazolyl)propyl silica gel, which is able to complex mercury ions. Mercury was chemically adsorbed on the modified graphite paste electrode containing 3-(2-thioimidazolyl)propyl silica (TIPSG GPE) by immersion in a Hg(II) solution, and the resultant surface was characterized by cyclic and differential pulse anodic stripping voltammetry. One cathodic peak at 0.1 V and other anodic peak at 0.34 V were observed on scanning the potential from -0.1 to 0.8 V (0.01 M KNO3; ν = 2.0 mV s-1 νs. Ag/AgCl). The anodic peak at 0.34 V show an excellent sensitivity for Hg(II) ions in the presence of several foreign ions. A calibration graph covering the concentration range from 0.02 to 2 mg L-1 was obtained. The detection limit was estimated to be 5 μg L-1. The precision for six determinations of 0.05 and 0.26 mg L-1 Hg(II) was 3.0 and 2.5% (relative standard deviation), respectively. The method can be used to determine the concentration of mercury(II) in natural waters contaminated by this metal. 2005 © The Japan Society for Analytical Chemistry.
Resumo:
Purpose: The objective of this study was to evaluate the position of the mandibular lingula (ML) to provide data for inferior alveolar nerve block techniques in children. Methods: One hundred fifty-four panoramic radiographs of 7- to 10-year-old boys and girls were analyzed. Measurements were taken from the ML to the occlusal plane, and the percentile distances of the ML to ramal borders were determined. Results: The distance between the ML and the occlusal plane showed a gradual increase, but only in the male group was it statistically significant. MLs ratio position on the ramus remained constant in all analyzed groups. In the 7-year-old group, the ML was observed above the occlusal plane in 70% of girls and 55% of boys. That percentage reached 85% of all children by age 10. Conclusions: The mandibular lingula's ratio position remained constant. Inferior alveolar anesthesia should be administered at least 6 mm above the occlusal plane in 7- to 8-year-old children, while 10 mm could be indicated for 9- to 10-year-old children. The mandibular lingula should be considered a reliable reference for further studies of inferior alveolar nerve block techniques.
Resumo:
The present work reports the use of a screen-printed carbon electrode (SPCE) modified by poly-L-histidine film to determine chromium (VI). Stable films can be formed by direct addition of PH solution 1 % (w/v) on the electrode surface, followed by heating at 80°C during 5 min. Calibration curves can be constructed for Cr(VI) from 1.0 × 10-5 mol L-1 to 7.0 × 10-5 mol L-1 Cr (VI) in acetate buffer pH 4 using a preconcentration step of 60s at open circuit potential. A relative standard deviation of 3.2% was for five determination of 4.0 × 10 -5 mol L-1 Cr (VI). The method was successful applied to determination of Cr(VI) in wastewater samples from a leather dyeing industry. copyright The Electrochemical Society.